From version < 26.14 >
edited by Xiaoling
on 2022/06/07 15:13
To version < 28.1 >
edited by Xiaoling
on 2022/06/07 15:38
>
Change comment: Uploaded new attachment "image-20220607153759-6.png", version {1}

Summary

Details

Page properties
Content
... ... @@ -427,8 +427,6 @@
427 427  Always 0x03
428 428  )))
429 429  
430 -
431 -
432 432  User can also send 0x14 downlink command to poll the current calibration payload.
433 433  
434 434  [[image:image-20220607145603-4.png]]
... ... @@ -436,8 +436,6 @@
436 436  * Reply to the confirmation package: 14 01
437 437  * Reply to non-confirmed packet: 14 00
438 438  
439 -
440 -
441 441  == 2.8 Frequency Plans ==
442 442  
443 443  (((
... ... @@ -493,8 +493,6 @@
493 493  * Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that sub-band
494 494  * Use the Join successful sub-band if the server doesn’t include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
495 495  
496 -
497 -
498 498  === 2.8.3 CN470-510 (CN470) ===
499 499  
500 500  Used in China, Default use CHE=1
... ... @@ -676,10 +676,9 @@
676 676  * The sensor is detected when the device is turned on, and it will flash 4 times quickly when it is detected.
677 677  * Blink once when device transmit a packet.
678 678  
679 -
680 -
681 681  == 2.10 ​Firmware Change Log ==
682 682  
675 +
683 683  **Firmware download link:**
684 684  
685 685  [[http:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/LSPH01/Firmware/>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/Firmware/]]
... ... @@ -689,22 +689,16 @@
689 689  
690 690  
691 691  
685 += 3. Configure LSPH01 via AT Command or LoRaWAN Downlink =
692 692  
693 -
694 -
695 -1. Configure LSPH01 via AT Command or LoRaWAN Downlink
696 -
697 697  Use can configure LSPH01 via AT Command or LoRaWAN Downlink.
698 698  
699 -* AT Command Connection: See [[FAQ>>path:#AT_COMMAND]].
700 -* LoRaWAN Downlink instruction for different platforms:
689 +* AT Command Connection: See [[FAQ>>||anchor="H6.FAQ"]].
690 +* LoRaWAN Downlink instruction for different platforms: [[IoT LoRaWAN Server>>doc:Main.WebHome]]
701 701  
702 -[[http:~~/~~/wiki.dragino.com/index.pHp?title=Main_Page#Use_Note_for_Server>>url:http://wiki.dragino.com/index.php?title=Main_Page#Use_Note_for_Server]]
703 -
704 -
705 705  There are two kinds of commands to configure LSPH01, they are:
706 706  
707 -* **General Commands**.
694 +* (% style="color:#4f81bd" %)** General Commands**.
708 708  
709 709  These commands are to configure:
710 710  
... ... @@ -711,25 +711,25 @@
711 711  * General system settings like: uplink interval.
712 712  * LoRaWAN protocol & radio related command.
713 713  
714 -They are same for all Dragino Device which support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki:
701 +They are same for all Dragino Device which support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki:[[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
715 715  
716 -[[http:~~/~~/wiki.dragino.com/index.pHp?title=End_Device_Downlink_Command>>url:http://wiki.dragino.com/index.php?title=End_Device_Downlink_Command]]
717 717  
704 +* (% style="color:#4f81bd" %)** Commands special design for LSPH01**
718 718  
719 -* **Commands special design for LSPH01**
720 -
721 721  These commands only valid for LSPH01, as below:
722 722  
723 723  
724 -1.
725 -11. Set Transmit Interval Time
726 726  
710 +== 3.1 Set Transmit Interval Time ==
711 +
727 727  Feature: Change LoRaWAN End Node Transmit Interval.
728 728  
729 -**AT Command: AT+TDC**
714 +(% style="color:#037691" %)**AT Command: AT+TDC**
730 730  
731 -|**Command Example**|**Function**|**Response**
732 -|AT+TDC=?|Show current transmit Interval|(((
716 +
717 +(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:710px" %)
718 +|(% style="width:154px" %)**Command Example**|(% style="width:223px" %)**Function**|(% style="width:330px" %)**Response**
719 +|(% style="width:154px" %)AT+TDC=?|(% style="width:223px" %)Show current transmit Interval|(% style="width:330px" %)(((
733 733  30000
734 734  
735 735  OK
... ... @@ -736,13 +736,13 @@
736 736  
737 737  the interval is 30000ms = 30s
738 738  )))
739 -|AT+TDC=60000|Set Transmit Interval|(((
726 +|(% style="width:154px" %)AT+TDC=60000|(% style="width:223px" %)Set Transmit Interval|(% style="width:330px" %)(((
740 740  OK
741 741  
742 742  Set transmit interval to 60000ms = 60 seconds
743 743  )))
744 744  
745 -**Downlink Command: 0x01**
732 +(% style="color:#037691" %)**Downlink Command: 0x01**
746 746  
747 747  Format: Command Code (0x01) followed by 3 bytes time value.
748 748  
... ... @@ -751,15 +751,16 @@
751 751  * Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds
752 752  * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds
753 753  
754 -1.
755 -11. Set Interrupt Mode
756 756  
742 +== 3.2 Set Interrupt Mode ==
743 +
757 757  Feature, Set Interrupt mode for GPIO_EXIT.
758 758  
759 -**AT Command: AT+INTMOD**
746 +(% style="color:#037691" %)**AT Command: AT+INTMOD**
760 760  
761 -|**Command Example**|**Function**|**Response**
762 -|AT+INTMOD=?|Show current interrupt mode|(((
748 +(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:709px" %)
749 +|=(% style="width: 163px;" %)**Command Example**|=(% style="width: 304px;" %)**Function**|=(% style="width: 239px;" %)**Response**
750 +|(% style="width:163px" %)AT+INTMOD=?|(% style="width:304px" %)Show current interrupt mode|(% style="width:239px" %)(((
763 763  0
764 764  
765 765  OK
... ... @@ -766,7 +766,7 @@
766 766  
767 767  the mode is 0 = No interruption
768 768  )))
769 -|AT+INTMOD=2|(((
757 +|(% style="width:163px" %)AT+INTMOD=2|(% style="width:304px" %)(((
770 770  Set Transmit Interval
771 771  
772 772  1. (Disable Interrupt),
... ... @@ -773,9 +773,9 @@
773 773  1. (Trigger by rising and falling edge),
774 774  1. (Trigger by falling edge)
775 775  1. (Trigger by rising edge)
776 -)))|OK
764 +)))|(% style="width:239px" %)OK
777 777  
778 -**Downlink Command: 0x06**
766 +(% style="color:#037691" %)**Downlink Command: 0x06**
779 779  
780 780  Format: Command Code (0x06) followed by 3 bytes.
781 781  
... ... @@ -784,9 +784,9 @@
784 784  * Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode
785 785  * Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger
786 786  
787 -1.
788 -11. Calibrate Sensor
789 789  
776 +== 3.3 Calibrate Sensor ==
777 +
790 790  Detail See [[Calibration Guide>>path:#Calibration]] for the user of 0x13 and 0x14 downlink commands
791 791  
792 792  
... ... @@ -797,7 +797,7 @@
797 797  Feature: use downlink to get firmware version.
798 798  
799 799  
800 -**Downlink Command: 0x26**
788 +(% style="color:#037691" %)**Downlink Command: 0x26**
801 801  
802 802  
803 803  |**Downlink Control Type**|**FPort**|**Type Code**|**Downlink payload size(bytes)**
image-20220607153237-5.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +12.9 KB
Content
image-20220607153759-6.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +17.2 KB
Content