<
From version < 26.11 >
edited by Xiaoling
on 2022/06/07 15:11
To version < 28.6 >
edited by Xiaoling
on 2022/06/07 15:42
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -427,8 +427,6 @@
427 427  Always 0x03
428 428  )))
429 429  
430 -
431 -
432 432  User can also send 0x14 downlink command to poll the current calibration payload.
433 433  
434 434  [[image:image-20220607145603-4.png]]
... ... @@ -436,8 +436,6 @@
436 436  * Reply to the confirmation package: 14 01
437 437  * Reply to non-confirmed packet: 14 00
438 438  
439 -
440 -
441 441  == 2.8 Frequency Plans ==
442 442  
443 443  (((
... ... @@ -493,8 +493,6 @@
493 493  * Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that sub-band
494 494  * Use the Join successful sub-band if the server doesn’t include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
495 495  
496 -
497 -
498 498  === 2.8.3 CN470-510 (CN470) ===
499 499  
500 500  Used in China, Default use CHE=1
... ... @@ -561,6 +561,7 @@
561 561  * Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that sub-band
562 562  * Use the Join successful sub-band if the server doesn’t include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
563 563  
558 +
564 564  === 2.8.5 AS920-923 & AS923-925 (AS923) ===
565 565  
566 566  (% style="color:blue" %)**Default Uplink channel:**
... ... @@ -676,33 +676,26 @@
676 676  
677 677  == 2.10 ​Firmware Change Log ==
678 678  
674 +
679 679  **Firmware download link:**
680 680  
681 681  [[http:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/LSPH01/Firmware/>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/Firmware/]]
682 682  
683 683  
684 -**Firmware Upgrade Method:[[Firmware Upgrade Instruction>>doc:Main.Firmware Upgrade Instruction for STM32 base products.WebHome]]**
680 +**Firmware Upgrade Method: **[[Firmware Upgrade Instruction>>doc:Main.Firmware Upgrade Instruction for STM32 base products.WebHome]]
685 685  
686 -[[http:~~/~~/wiki.dragino.com/index.pHp?title=Firmware_Upgrade_Instruction_for_STM32_base_products#Introduction>>url:http://wiki.dragino.com/index.php?title=Firmware_Upgrade_Instruction_for_STM32_base_products#Introduction]]
687 687  
688 688  
684 += 3. Configure LSPH01 via AT Command or LoRaWAN Downlink =
689 689  
690 -
691 -
692 -
693 -1. Configure LSPH01 via AT Command or LoRaWAN Downlink
694 -
695 695  Use can configure LSPH01 via AT Command or LoRaWAN Downlink.
696 696  
697 -* AT Command Connection: See [[FAQ>>path:#AT_COMMAND]].
698 -* LoRaWAN Downlink instruction for different platforms:
688 +* AT Command Connection: See [[FAQ>>||anchor="H6.FAQ"]].
689 +* LoRaWAN Downlink instruction for different platforms: [[IoT LoRaWAN Server>>doc:Main.WebHome]]
699 699  
700 -[[http:~~/~~/wiki.dragino.com/index.pHp?title=Main_Page#Use_Note_for_Server>>url:http://wiki.dragino.com/index.php?title=Main_Page#Use_Note_for_Server]]
701 -
702 -
703 703  There are two kinds of commands to configure LSPH01, they are:
704 704  
705 -* **General Commands**.
693 +* (% style="color:#4f81bd" %)** General Commands**.
706 706  
707 707  These commands are to configure:
708 708  
... ... @@ -709,25 +709,25 @@
709 709  * General system settings like: uplink interval.
710 710  * LoRaWAN protocol & radio related command.
711 711  
712 -They are same for all Dragino Device which support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki:
700 +They are same for all Dragino Device which support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki:[[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
713 713  
714 -[[http:~~/~~/wiki.dragino.com/index.pHp?title=End_Device_Downlink_Command>>url:http://wiki.dragino.com/index.php?title=End_Device_Downlink_Command]]
715 715  
703 +* (% style="color:#4f81bd" %)** Commands special design for LSPH01**
716 716  
717 -* **Commands special design for LSPH01**
718 -
719 719  These commands only valid for LSPH01, as below:
720 720  
721 721  
722 -1.
723 -11. Set Transmit Interval Time
724 724  
709 +== 3.1 Set Transmit Interval Time ==
710 +
725 725  Feature: Change LoRaWAN End Node Transmit Interval.
726 726  
727 -**AT Command: AT+TDC**
713 +(% style="color:#037691" %)**AT Command: AT+TDC**
728 728  
729 -|**Command Example**|**Function**|**Response**
730 -|AT+TDC=?|Show current transmit Interval|(((
715 +
716 +(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:710px" %)
717 +|(% style="width:154px" %)**Command Example**|(% style="width:223px" %)**Function**|(% style="width:330px" %)**Response**
718 +|(% style="width:154px" %)AT+TDC=?|(% style="width:223px" %)Show current transmit Interval|(% style="width:330px" %)(((
731 731  30000
732 732  
733 733  OK
... ... @@ -734,13 +734,13 @@
734 734  
735 735  the interval is 30000ms = 30s
736 736  )))
737 -|AT+TDC=60000|Set Transmit Interval|(((
725 +|(% style="width:154px" %)AT+TDC=60000|(% style="width:223px" %)Set Transmit Interval|(% style="width:330px" %)(((
738 738  OK
739 739  
740 740  Set transmit interval to 60000ms = 60 seconds
741 741  )))
742 742  
743 -**Downlink Command: 0x01**
731 +(% style="color:#037691" %)**Downlink Command: 0x01**
744 744  
745 745  Format: Command Code (0x01) followed by 3 bytes time value.
746 746  
... ... @@ -749,31 +749,18 @@
749 749  * Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds
750 750  * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds
751 751  
752 -1.
753 -11. Set Interrupt Mode
754 754  
755 -Feature, Set Interrupt mode for GPIO_EXIT.
756 756  
757 -**AT Command: AT+INTMOD**
742 +== 3.2 Set Interrupt Mode ==
758 758  
759 -|**Command Example**|**Function**|**Response**
760 -|AT+INTMOD=?|Show current interrupt mode|(((
761 -0
744 +Feature, Set Interrupt mode for GPIO_EXIT.
762 762  
763 -OK
746 +(% style="color:#037691" %)**AT Command: AT+INTMOD**
764 764  
765 -the mode is 0 = No interruption
766 -)))
767 -|AT+INTMOD=2|(((
768 -Set Transmit Interval
748 +[[image:image-20220607153759-6.png]]
769 769  
770 -1. (Disable Interrupt),
771 -1. (Trigger by rising and falling edge),
772 -1. (Trigger by falling edge)
773 -1. (Trigger by rising edge)
774 -)))|OK
775 775  
776 -**Downlink Command: 0x06**
751 +(% style="color:#037691" %)**Downlink Command: 0x06**
777 777  
778 778  Format: Command Code (0x06) followed by 3 bytes.
779 779  
... ... @@ -782,20 +782,21 @@
782 782  * Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode
783 783  * Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger
784 784  
785 -1.
786 -11. Calibrate Sensor
787 787  
788 -Detail See [[Calibration Guide>>path:#Calibration]] for the user of 0x13 and 0x14 downlink commands
789 789  
762 +== 3.3 Calibrate Sensor ==
790 790  
764 +Detail See [[Calibration Guide>>||anchor="2.7Calibration"]] for the user of 0x13 and 0x14 downlink commands
791 791  
792 -1.
793 -11. Get Firmware Version Info
794 794  
767 +
768 +
769 +== 3.4 Get Firmware Version Info ==
770 +
795 795  Feature: use downlink to get firmware version.
796 796  
797 797  
798 -**Downlink Command: 0x26**
774 +(% style="color:#037691" %)**Downlink Command: 0x26**
799 799  
800 800  
801 801  |**Downlink Control Type**|**FPort**|**Type Code**|**Downlink payload size(bytes)**
... ... @@ -898,7 +898,7 @@
898 898  LSPH01:  2.45v ~~ 3.6v
899 899  
900 900  
901 -1.
877 +1.
902 902  11. Replace Battery
903 903  
904 904  Any battery with range 2.45 ~~ 3.6v can be a replacement. We recommend to use Li-SOCl2 Battery.
... ... @@ -907,7 +907,7 @@
907 907  
908 908  
909 909  
910 -1.
886 +1.
911 911  11. Power Consumption Analyze
912 912  
913 913  Dragino Battery powered product are all runs in Low Power mode. We have an update battery calculator which base on the measurement of the real device. User can use this calculator to check the battery life and calculate the battery life if want to use different transmit interval.
... ... @@ -947,14 +947,14 @@
947 947  
948 948  
949 949  1.
950 -11.
926 +11.
951 951  111. ​Battery Note
952 952  
953 953  The Li-SICO battery is designed for small current / long period application. It is not good to use a high current, short period transmit method. The recommended minimum period for use of this battery is 5 minutes. If you use a shorter period time to transmit LoRa, then the battery life may be decreased.
954 954  
955 955  
956 -1.
957 -11.
932 +1.
933 +11.
958 958  111. ​Replace the battery
959 959  
960 960  You can change the battery in the LSPH01.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there won’t be voltage drop between battery and main board.
image-20220607153237-5.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +12.9 KB
Content
image-20220607153759-6.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +17.2 KB
Content
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0