<
From version < 26.11 >
edited by Xiaoling
on 2022/06/07 15:11
To version < 28.3 >
edited by Xiaoling
on 2022/06/07 15:38
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -427,8 +427,6 @@
427 427  Always 0x03
428 428  )))
429 429  
430 -
431 -
432 432  User can also send 0x14 downlink command to poll the current calibration payload.
433 433  
434 434  [[image:image-20220607145603-4.png]]
... ... @@ -436,8 +436,6 @@
436 436  * Reply to the confirmation package: 14 01
437 437  * Reply to non-confirmed packet: 14 00
438 438  
439 -
440 -
441 441  == 2.8 Frequency Plans ==
442 442  
443 443  (((
... ... @@ -493,8 +493,6 @@
493 493  * Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that sub-band
494 494  * Use the Join successful sub-band if the server doesn’t include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
495 495  
496 -
497 -
498 498  === 2.8.3 CN470-510 (CN470) ===
499 499  
500 500  Used in China, Default use CHE=1
... ... @@ -561,6 +561,8 @@
561 561  * Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that sub-band
562 562  * Use the Join successful sub-band if the server doesn’t include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
563 563  
558 +
559 +
564 564  === 2.8.5 AS920-923 & AS923-925 (AS923) ===
565 565  
566 566  (% style="color:blue" %)**Default Uplink channel:**
... ... @@ -676,33 +676,26 @@
676 676  
677 677  == 2.10 ​Firmware Change Log ==
678 678  
675 +
679 679  **Firmware download link:**
680 680  
681 681  [[http:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/LSPH01/Firmware/>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/Firmware/]]
682 682  
683 683  
684 -**Firmware Upgrade Method:[[Firmware Upgrade Instruction>>doc:Main.Firmware Upgrade Instruction for STM32 base products.WebHome]]**
681 +**Firmware Upgrade Method: **[[Firmware Upgrade Instruction>>doc:Main.Firmware Upgrade Instruction for STM32 base products.WebHome]]
685 685  
686 -[[http:~~/~~/wiki.dragino.com/index.pHp?title=Firmware_Upgrade_Instruction_for_STM32_base_products#Introduction>>url:http://wiki.dragino.com/index.php?title=Firmware_Upgrade_Instruction_for_STM32_base_products#Introduction]]
687 687  
688 688  
685 += 3. Configure LSPH01 via AT Command or LoRaWAN Downlink =
689 689  
690 -
691 -
692 -
693 -1. Configure LSPH01 via AT Command or LoRaWAN Downlink
694 -
695 695  Use can configure LSPH01 via AT Command or LoRaWAN Downlink.
696 696  
697 -* AT Command Connection: See [[FAQ>>path:#AT_COMMAND]].
698 -* LoRaWAN Downlink instruction for different platforms:
689 +* AT Command Connection: See [[FAQ>>||anchor="H6.FAQ"]].
690 +* LoRaWAN Downlink instruction for different platforms: [[IoT LoRaWAN Server>>doc:Main.WebHome]]
699 699  
700 -[[http:~~/~~/wiki.dragino.com/index.pHp?title=Main_Page#Use_Note_for_Server>>url:http://wiki.dragino.com/index.php?title=Main_Page#Use_Note_for_Server]]
701 -
702 -
703 703  There are two kinds of commands to configure LSPH01, they are:
704 704  
705 -* **General Commands**.
694 +* (% style="color:#4f81bd" %)** General Commands**.
706 706  
707 707  These commands are to configure:
708 708  
... ... @@ -709,25 +709,25 @@
709 709  * General system settings like: uplink interval.
710 710  * LoRaWAN protocol & radio related command.
711 711  
712 -They are same for all Dragino Device which support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki:
701 +They are same for all Dragino Device which support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki:[[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
713 713  
714 -[[http:~~/~~/wiki.dragino.com/index.pHp?title=End_Device_Downlink_Command>>url:http://wiki.dragino.com/index.php?title=End_Device_Downlink_Command]]
715 715  
704 +* (% style="color:#4f81bd" %)** Commands special design for LSPH01**
716 716  
717 -* **Commands special design for LSPH01**
718 -
719 719  These commands only valid for LSPH01, as below:
720 720  
721 721  
722 -1.
723 -11. Set Transmit Interval Time
724 724  
710 +== 3.1 Set Transmit Interval Time ==
711 +
725 725  Feature: Change LoRaWAN End Node Transmit Interval.
726 726  
727 -**AT Command: AT+TDC**
714 +(% style="color:#037691" %)**AT Command: AT+TDC**
728 728  
729 -|**Command Example**|**Function**|**Response**
730 -|AT+TDC=?|Show current transmit Interval|(((
716 +
717 +(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:710px" %)
718 +|(% style="width:154px" %)**Command Example**|(% style="width:223px" %)**Function**|(% style="width:330px" %)**Response**
719 +|(% style="width:154px" %)AT+TDC=?|(% style="width:223px" %)Show current transmit Interval|(% style="width:330px" %)(((
731 731  30000
732 732  
733 733  OK
... ... @@ -734,13 +734,13 @@
734 734  
735 735  the interval is 30000ms = 30s
736 736  )))
737 -|AT+TDC=60000|Set Transmit Interval|(((
726 +|(% style="width:154px" %)AT+TDC=60000|(% style="width:223px" %)Set Transmit Interval|(% style="width:330px" %)(((
738 738  OK
739 739  
740 740  Set transmit interval to 60000ms = 60 seconds
741 741  )))
742 742  
743 -**Downlink Command: 0x01**
732 +(% style="color:#037691" %)**Downlink Command: 0x01**
744 744  
745 745  Format: Command Code (0x01) followed by 3 bytes time value.
746 746  
... ... @@ -749,32 +749,18 @@
749 749  * Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds
750 750  * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds
751 751  
752 -1.
753 -11. Set Interrupt Mode
754 754  
742 +== 3.2 Set Interrupt Mode ==
743 +
755 755  Feature, Set Interrupt mode for GPIO_EXIT.
756 756  
757 -**AT Command: AT+INTMOD**
746 +(% style="color:#037691" %)**AT Command: AT+INTMOD**
758 758  
759 -|**Command Example**|**Function**|**Response**
760 -|AT+INTMOD=?|Show current interrupt mode|(((
761 -0
748 +[[image:image-20220607153759-6.png]]
762 762  
763 -OK
764 764  
765 -the mode is 0 = No interruption
766 -)))
767 -|AT+INTMOD=2|(((
768 -Set Transmit Interval
751 +(% style="color:#037691" %)**Downlink Command: 0x06**
769 769  
770 -1. (Disable Interrupt),
771 -1. (Trigger by rising and falling edge),
772 -1. (Trigger by falling edge)
773 -1. (Trigger by rising edge)
774 -)))|OK
775 -
776 -**Downlink Command: 0x06**
777 -
778 778  Format: Command Code (0x06) followed by 3 bytes.
779 779  
780 780  This means that the interrupt mode of the end node is set to 0x000003=3 (rising edge trigger), and the type code is 06.
... ... @@ -782,20 +782,20 @@
782 782  * Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode
783 783  * Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger
784 784  
785 -1.
786 -11. Calibrate Sensor
787 787  
761 +== 3.3 Calibrate Sensor ==
762 +
788 788  Detail See [[Calibration Guide>>path:#Calibration]] for the user of 0x13 and 0x14 downlink commands
789 789  
790 790  
791 791  
792 -1.
793 -11. Get Firmware Version Info
794 794  
768 +== 3.4 Get Firmware Version Info ==
769 +
795 795  Feature: use downlink to get firmware version.
796 796  
797 797  
798 -**Downlink Command: 0x26**
773 +(% style="color:#037691" %)**Downlink Command: 0x26**
799 799  
800 800  
801 801  |**Downlink Control Type**|**FPort**|**Type Code**|**Downlink payload size(bytes)**
image-20220607153237-5.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +12.9 KB
Content
image-20220607153759-6.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +17.2 KB
Content
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0