55 55  * IP68 rate for the Sensor Probe
56 56  * 8500mAh Battery for long term use
57 57  
58 -
59 -
60 60  == 1.3 Probe Specification ==
61 61  
62 62  
... ... @@ -77,14 +77,10 @@
77 77  * IP68 Protection
78 78  * Length: 3.5 meters
79 79  
80 -
81 -
82 82  == 1.4 ​Applications ==
83 83  
84 84  * Smart Agriculture
85 85  
86 -
87 -
88 88  == 1.5 Pin mapping and power on ==
89 89  
90 90  [[image:1654580482666-473.png]]
... ... @@ -119,7 +119,7 @@
119 119  )))
120 120  
121 121  (((
122 -**Step 1**: Create a device in TTN with the OTAA keys from LSPH01.
116 +(% style="color:blue" %)**Step 1**(%%): Create a device in TTN with the OTAA keys from LSPH01.
123 123  )))
124 124  
125 125  (((
... ... @@ -156,7 +156,7 @@
156 156  [[image:1654581517630-991.png]]
157 157  
158 158  
159 -**Step 2**: Power on LSPH01
153 +(% style="color:blue" %)**Step 2**(%%): Power on LSPH01
160 160  
161 161  
162 162  Put a Jumper on JP2 to power on the device. ( The Switch must be in FLASH position).
... ... @@ -164,7 +164,7 @@
164 164  [[image:image-20220607135918-2.png]]
165 165  
166 166  
167 -**Step 3:** The LSPH01 will auto join to the TTN network. After join success, it will start to upload messages to TTN and you can see the messages in the panel.
161 +(% style="color:blue" %)**Step 3**(%%)**:** The LSPH01 will auto join to the TTN network. After join success, it will start to upload messages to TTN and you can see the messages in the panel.
168 168  
169 169  [[image:1654581590132-631.png]]
170 170  
... ... @@ -271,8 +271,6 @@
271 271  |0x02|Reply configures info|[[Configure Info Payload>>||anchor="H3.4GetFirmwareVersionInfo"]]
272 272  |0x03|Reply Calibration Info|[[Calibration Payload>>||anchor="H2.7Calibration"]]
273 273  
274 -
275 -
276 276  === 2.3.7 Decode payload in The Things Network ===
277 277  
278 278  While using TTN network, you can add the payload format to decode the payload.
... ... @@ -296,109 +296,117 @@
296 296  
297 297  
298 298  
291 +== 2.5 ​Show Data in DataCake IoT Server ==
299 299  
300 -1.
301 -11. ​Show Data in DataCake IoT Server
302 -
303 303  [[DATACAKE>>url:https://datacake.co/]] provides a human friendly interface to show the sensor data, once we have data in TTN, we can use [[DATACAKE>>url:https://datacake.co/]] to connect to TTN and see the data in DATACAKE. Below are the steps:
304 304  
305 305  
306 -**Step 1**: Be sure that your device is programmed and properly connected to the network at this time.
296 +(% style="color:blue" %)**Step 1**(%%)**: Be sure that your device is programmed and properly connected to the network at this time.**
307 307  
308 -**Step 2**: To configure the Application to forward data to DATACAKE you will need to add integration. To add the DATACAKE integration, perform the following steps:
298 +(% style="color:blue" %)**Step 2**(%%)**: To configure the Application to forward data to DATACAKE you will need to add integration. To add the DATACAKE integration, perform the following steps:**
309 309  
310 310  
311 -[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image012.png]]
301 +[[image:1654583683416-869.png]]
312 312  
313 313  
314 -[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image013.png]]
304 +[[image:1654583694084-878.png]]
315 315  
316 316  
317 -Step 3: Create an account or log in Datacake.
307 +(% style="color:blue" %)**Step 3**(%%)**: Create an account or log in Datacake.**
318 318  
319 -Step 4: Create LSPH01 product.
309 +(% style="color:blue" %)**Step 4**(%%)**: Create LSPH01 product.**
320 320  
321 -[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image014.png]]
311 +[[image:1654583711590-413.png]]
322 322  
323 323  
324 324  
325 -[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image015.png]]
315 +[[image:1654583732798-193.png]]
326 326  
327 327  
328 -[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image016.png]]
318 +[[image:1654583749683-259.png]]
329 329  
330 330  
331 -Step 5: add payload decode
321 +(% style="color:blue" %)**Step 5**(%%)**: add payload decode**
332 332  
333 333  Download Datacake decoder from: [[https:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/LSPH01/Decoder/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSNPK01/Decoder/]]
334 334  
335 335  
336 -[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image017.png]]
326 +[[image:1654583770974-935.png]]
337 337  
338 -[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image018.png]]
328 +[[image:1654583781517-146.png]]
339 339  
340 340  
341 -[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image019.png]]
331 +[[image:1654583791351-557.png]]
342 342  
343 343  
344 344  After added, the sensor data arrive TTN, it will also arrive and show in Mydevices.
345 345  
346 346  
347 -[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image020.png]]
337 +[[image:1654583805491-713.png]]
348 348  
349 349  
350 350  
351 351  
352 352  
353 -1.
354 -11. Installation and Maintain
355 -111. Before measurement
343 +== 2.6 Installation and Maintain ==
356 356  
345 +=== 2.6.1 Before measurement ===
346 +
347 +(((
357 357  If the LSPH01 has more than 7 days not use or just clean the pH probe. User should put the probe inside pure water for more than 24 hours for activation. If no put in water, user need to put inside soil for more than 24 hours to ensure the measurement accuracy. 
349 +)))
358 358  
359 359  
360 -1.
361 -11.
362 -111. Measurement
363 363  
364 -**Measurement the soil surface**
353 +=== 2.6.2 Measurement ===
365 365  
366 366  
367 -[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image021.png]] Choose the proper measuring position. Split the surface soil according to the measured deep.
356 +(% style="color:#4f81bd" %)**Measurement the soil surface:**
368 368  
358 +[[image:1654584128046-287.png]]
369 369  
360 +Choose the proper measuring position. Split the surface soil according to the measured deep.
361 +
370 370  Put pure water, or rainwater to make the soil of measurement point to moist mud. Remove rocks or hard things.
371 371  
372 -
373 373  Slowly insert the probe to the measure point. Don’t use large force which will break the probe. Make sure not shake when inserting.
374 374  
375 -
376 376  Put soil over the probe after insert. And start to measure.
377 377  
378 378  
379 -**Measurement inside soil**
369 +(% style="color:#4f81bd" %)**Measurement inside soil:**
380 380  
371 +Dig a hole with diameter > 20CM.
381 381  
373 +Insert the probe inside, method like measure the surface.
382 382  
383 -Dig a hole with diameter > 20CM.
384 384  
385 385  
386 -Insert the probe inside, method like measure the surface.
377 +=== 2.6.3 Maintain Probe ===
387 387  
379 +1. (((
380 +pH probe electrode is fragile and no strong. User must avoid strong force or hitting it.
381 +)))
382 +1. (((
383 +After long time use (3~~ 6  months). The probe electrode needs to be clean; user can use high grade sandpaper to polish it or put in 5% hydrochloric acid for several minutes. After the metal probe looks like new, user can use pure water to wash it.
384 +)))
385 +1. (((
386 +Probe reference electrode is also no strong, need to avoid strong force or hitting.
387 +)))
388 +1. (((
389 +User should keep reference electrode wet while not use.
390 +)))
391 +1. (((
392 +Avoid the probes to touch oily matter. Which will cause issue in accuracy.
393 +)))
394 +1. (((
395 +The probe is IP68 can be put in water.
396 +)))
388 388  
389 -1.
390 -11.
391 -111. Maintain Probe
392 -1111. pH probe electrode is fragile and no strong. User must avoid strong force or hitting it.
393 -1111. After long time use (3~~ 6  months). The probe electrode needs to be clean; user can use high grade sandpaper to polish it or put in 5% hydrochloric acid for several minutes. After the metal probe looks like new, user can use pure water to wash it.
394 -1111. Probe reference electrode is also no strong, need to avoid strong force or hitting.
395 -1111. User should keep reference electrode wet while not use.
396 -1111. Avoid the probes to touch oily matter. Which will cause issue in accuracy.
397 -1111. The probe is IP68 can be put in water.
398 398  
399 -1.
400 -11. Calibration
401 401  
400 +== 2.7 Calibration ==
401 +
402 402  User can do calibration for the probe. It is limited to use below pH buffer solution to calibrate: 4.00, 6.86, 9.18. When calibration, user need to clean the electrode and put the probe in the pH buffer solution to wait the value stable ( a new clean electrode might need max 24 hours to be stable).
403 403  
404 404  
1654583711590-413.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +246.2 KB
Content
1654583732798-193.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +199.6 KB
Content
1654583749683-259.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +129.1 KB
Content
1654583770974-935.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +37.7 KB
Content
1654583781517-146.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +64.0 KB
Content
1654583791351-557.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +11.3 KB
Content
1654583805491-713.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +127.1 KB
Content
1654584128046-287.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +345.3 KB
Content
image-20220607144936-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +23.6 KB
Content
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0