From version < 14.9 >
edited by Xiaoling
on 2022/06/07 14:33
To version < 14.3 >
edited by Xiaoling
on 2022/06/07 14:16
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -5,9 +5,7 @@
5 5  
6 6  
7 7  
8 -**Contents:**
9 9  
10 -{{toc/}}
11 11  
12 12  
13 13  
... ... @@ -17,9 +17,6 @@
17 17  
18 18  
19 19  
20 -
21 -
22 -
23 23  = 1. Introduction =
24 24  
25 25  == 1.1 ​What is LoRaWAN Soil pH Sensor ==
... ... @@ -55,8 +55,6 @@
55 55  * IP68 rate for the Sensor Probe
56 56  * 8500mAh Battery for long term use
57 57  
58 -
59 -
60 60  == 1.3 Probe Specification ==
61 61  
62 62  
... ... @@ -180,14 +180,18 @@
180 180  
181 181  **(bytes)**
182 182  )))|**2**|**2**|**2**|**2**|**1**|**1**|**1**
183 -|**Value**|[[BAT>>||anchor="H2.3.1BatteryInfo"]]|(((
184 -[[Temperature>>||anchor="H2.3.2DS18B20Temperaturesensor"]]
176 +|**Value**|[[BAT>>path:#bat]]|(((
177 +[[Temperature>>path:#DS18B20]]
185 185  
186 -[[(Optional)>>||anchor="H2.3.2DS18B20Temperaturesensor"]]
187 -)))|[[Soil pH>>||anchor="H2.3.3SoilpH"]]|[[Soil Temperature>>||anchor="H2.3.4SoilTemperature"]]|(((
188 -[[Digital Interrupt (Optional)>>||anchor="H2.3.5InterruptPin"]]
179 +[[( Optional )>>path:#DS18B20]]
180 +)))|[[Soil pH>>path:#Soil_Nitrogen]]|[[Soil Temperature>>path:#Soil_Phosphorus]]|(((
181 +[[Digital Interrupt>>path:#Int_pin]]
182 +
183 +[[(Optional)>>path:#Int_pin]]
189 189  )))|Reserve|(((
190 -[[Message Type>>||anchor="H2.3.6MessageType"]]
185 +[[Message>>path:#Message_Type]]
186 +
187 +[[Type>>path:#Message_Type]]
191 191  )))
192 192  
193 193  [[image:1654581735133-458.png]]
... ... @@ -288,12 +288,13 @@
288 288  
289 289  == 2.4 Uplink Interval ==
290 290  
291 -The LSPH01 by default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link: [[Change Uplink Interval>>doc:Main.End Device AT Commands and Downlink Command.WebHome||anchor="H4.1ChangeUplinkInterval"]]
288 +The LSPH01 by default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link:
292 292  
290 +[[http:~~/~~/wiki.dragino.com/index.pHp?title=End_Device_AT_Commands_and_Downlink_Commands#Change_Uplink_Interval>>url:http://wiki.dragino.com/index.php?title=End_Device_AT_Commands_and_Downlink_Commands#Change_Uplink_Interval]]
293 293  
294 294  
295 295  
296 -1.
294 +1.
297 297  11. ​Show Data in DataCake IoT Server
298 298  
299 299  [[DATACAKE>>url:https://datacake.co/]] provides a human friendly interface to show the sensor data, once we have data in TTN, we can use [[DATACAKE>>url:https://datacake.co/]] to connect to TTN and see the data in DATACAKE. Below are the steps:
... ... @@ -353,8 +353,8 @@
353 353  If the LSPH01 has more than 7 days not use or just clean the pH probe. User should put the probe inside pure water for more than 24 hours for activation. If no put in water, user need to put inside soil for more than 24 hours to ensure the measurement accuracy. 
354 354  
355 355  
356 -1.
357 -11.
354 +1.
355 +11.
358 358  111. Measurement
359 359  
360 360  **Measurement the soil surface**
... ... @@ -382,8 +382,8 @@
382 382  Insert the probe inside, method like measure the surface.
383 383  
384 384  
385 -1.
386 -11.
383 +1.
384 +11.
387 387  111. Maintain Probe
388 388  1111. pH probe electrode is fragile and no strong. User must avoid strong force or hitting it.
389 389  1111. After long time use (3~~ 6  months). The probe electrode needs to be clean; user can use high grade sandpaper to polish it or put in 5% hydrochloric acid for several minutes. After the metal probe looks like new, user can use pure water to wash it.
... ... @@ -392,7 +392,7 @@
392 392  1111. Avoid the probes to touch oily matter. Which will cause issue in accuracy.
393 393  1111. The probe is IP68 can be put in water.
394 394  
395 -1.
393 +1.
396 396  11. Calibration
397 397  
398 398  User can do calibration for the probe. It is limited to use below pH buffer solution to calibrate: 4.00, 6.86, 9.18. When calibration, user need to clean the electrode and put the probe in the pH buffer solution to wait the value stable ( a new clean electrode might need max 24 hours to be stable).
... ... @@ -463,13 +463,13 @@
463 463  * Reply to the confirmation package: 14 01
464 464  * Reply to non-confirmed packet: 14 00
465 465  
466 -1.
464 +1.
467 467  11. Frequency Plans
468 468  
469 469  The LSPH01 uses OTAA mode and below frequency plans by default. If user want to use it with different frequency plan, please refer the AT command sets.
470 470  
471 -1.
472 -11.
469 +1.
470 +11.
473 473  111. EU863-870 (EU868)
474 474  
475 475  Uplink:
... ... @@ -500,8 +500,8 @@
500 500  869.525 - SF9BW125 (RX2 downlink only)
501 501  
502 502  
503 -1.
504 -11.
501 +1.
502 +11.
505 505  111. US902-928(US915)
506 506  
507 507  Used in USA, Canada and South America. Frequency band as per definition in LoRaWAN 1.0.3 Regional document.
... ... @@ -515,8 +515,8 @@
515 515  * Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that sub-band
516 516  * Use the Join successful sub-band if the server doesn’t include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
517 517  
518 -1.
519 -11.
516 +1.
517 +11.
520 520  111. CN470-510 (CN470)
521 521  
522 522  Used in China, Default use CHE=1
... ... @@ -561,8 +561,8 @@
561 561  505.3 - SF12BW125 (RX2 downlink only)
562 562  
563 563  
564 -1.
565 -11.
562 +1.
563 +11.
566 566  111. AU915-928(AU915)
567 567  
568 568  Frequency band as per definition in LoRaWAN 1.0.3 Regional document.
... ... @@ -576,8 +576,8 @@
576 576  * Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that sub-band
577 577  * Use the Join successful sub-band if the server doesn’t include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
578 578  
579 -1.
580 -11.
577 +1.
578 +11.
581 581  111. AS920-923 & AS923-925 (AS923)
582 582  
583 583  **Default Uplink channel:**
... ... @@ -629,8 +629,8 @@
629 629  923.2 - SF10BW125 (RX2)
630 630  
631 631  
632 -1.
633 -11.
630 +1.
631 +11.
634 634  111. KR920-923 (KR920)
635 635  
636 636  Default channel:
... ... @@ -666,8 +666,8 @@
666 666  921.9 - SF12BW125 (RX2 downlink only; SF12BW125 might be changed to SF9BW125)
667 667  
668 668  
669 -1.
670 -11.
667 +1.
668 +11.
671 671  111. IN865-867 (IN865)
672 672  
673 673  Uplink:
... ... @@ -686,7 +686,7 @@
686 686  866.550 - SF10BW125 (RX2)
687 687  
688 688  
689 -1.
687 +1.
690 690  11. LED Indicator
691 691  
692 692  The LSPH01 has an internal LED which is to show the status of different state.
... ... @@ -695,7 +695,7 @@
695 695  * The sensor is detected when the device is turned on, and it will flash 4 times quickly when it is detected.
696 696  * Blink once when device transmit a packet.
697 697  
698 -1.
696 +1.
699 699  11. ​Firmware Change Log
700 700  
701 701  **Firmware download link:**
... ... @@ -741,7 +741,7 @@
741 741  These commands only valid for LSPH01, as below:
742 742  
743 743  
744 -1.
742 +1.
745 745  11. Set Transmit Interval Time
746 746  
747 747  Feature: Change LoRaWAN End Node Transmit Interval.
... ... @@ -771,7 +771,7 @@
771 771  * Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds
772 772  * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds
773 773  
774 -1.
772 +1.
775 775  11. Set Interrupt Mode
776 776  
777 777  Feature, Set Interrupt mode for GPIO_EXIT.
... ... @@ -804,7 +804,7 @@
804 804  * Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode
805 805  * Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger
806 806  
807 -1.
805 +1.
808 808  11. Calibrate Sensor
809 809  
810 810  Detail See [[Calibration Guide>>path:#Calibration]] for the user of 0x13 and 0x14 downlink commands
... ... @@ -811,7 +811,7 @@
811 811  
812 812  
813 813  
814 -1.
812 +1.
815 815  11. Get Firmware Version Info
816 816  
817 817  Feature: use downlink to get firmware version.
... ... @@ -920,7 +920,7 @@
920 920  LSPH01:  2.45v ~~ 3.6v
921 921  
922 922  
923 -1.
921 +1.
924 924  11. Replace Battery
925 925  
926 926  Any battery with range 2.45 ~~ 3.6v can be a replacement. We recommend to use Li-SOCl2 Battery.
... ... @@ -929,7 +929,7 @@
929 929  
930 930  
931 931  
932 -1.
930 +1.
933 933  11. Power Consumption Analyze
934 934  
935 935  Dragino Battery powered product are all runs in Low Power mode. We have an update battery calculator which base on the measurement of the real device. User can use this calculator to check the battery life and calculate the battery life if want to use different transmit interval.
... ... @@ -969,14 +969,14 @@
969 969  
970 970  
971 971  1.
972 -11.
970 +11.
973 973  111. ​Battery Note
974 974  
975 975  The Li-SICO battery is designed for small current / long period application. It is not good to use a high current, short period transmit method. The recommended minimum period for use of this battery is 5 minutes. If you use a shorter period time to transmit LoRa, then the battery life may be decreased.
976 976  
977 977  
978 -1.
979 -11.
976 +1.
977 +11.
980 980  111. ​Replace the battery
981 981  
982 982  You can change the battery in the LSPH01.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there won’t be voltage drop between battery and main board.
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0