Changes for page LHT65N-PIR Temperature/Humidity/PIR Motion Sensor User Manual
Last modified by Xiaoling on 2025/04/24 10:00
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 -LHT65-PIR Temperature/Humidity/PIR Sensor User Manual 1 +LHT65-PIR Temperature/Humidity/PIR Motion Sensor User Manual - Content
-
... ... @@ -156,8 +156,73 @@ 156 156 [[image:image-20220522233300-8.png||_mstalt="428389" height="219" width="722"]] 157 157 158 158 159 -== 2.4 Uplink Payload (Fport~=2) ==159 +== 2.4 Uplink Payload~-~-Device Status, (Fport~=5) == 160 160 161 +Users can use the downlink command(**0x26 01**) to ask LHT65N-PIR to send device configure detail, include device configure status. LHT65N-PIR will uplink a payload via FPort=5 to server. 162 + 163 +The Payload format is as below. 164 + 165 +|(% colspan="6" %)**Device Status (FPORT=5)** 166 +|**Size (bytes)**|**1**|**2**|**1**|**1**|**2** 167 +|**Value**|Sensor Model|Firmware Version|Frequency Band|Sub-band|BAT 168 + 169 +Example parse in TTNv3 170 + 171 +[[image:1675144504430-490.png]] 172 + 173 +**Sensor Model**: For LHT65N-PIR, this value is 0x1A 174 + 175 +**Firmware Version**: 0x0100, Means: v1.0.0 version 176 + 177 +**Frequency Band**: 178 + 179 +*0x01: EU868 180 + 181 +*0x02: US915 182 + 183 +*0x03: IN865 184 + 185 +*0x04: AU915 186 + 187 +*0x05: KZ865 188 + 189 +*0x06: RU864 190 + 191 +*0x07: AS923 192 + 193 +*0x08: AS923-1 194 + 195 +*0x09: AS923-2 196 + 197 +*0x0a: AS923-3 198 + 199 +*0x0b: CN470 200 + 201 +*0x0c: EU433 202 + 203 +*0x0d: KR920 204 + 205 +*0x0e: MA869 206 + 207 +**Sub-Band**: 208 + 209 +AU915 and US915:value 0x00 ~~ 0x08 210 + 211 +CN470: value 0x0B ~~ 0x0C 212 + 213 +Other Bands: Always 0x00 214 + 215 +**Battery Info**: 216 + 217 +Check the battery voltage. 218 + 219 +Ex1: 0x0B45 = 2885mV 220 + 221 +Ex2: 0x0B49 = 2889mV 222 + 223 + 224 +== 2.5 Uplink Payload, Sensor Data ( Fport~=2) == 225 + 161 161 The uplink payload includes totally 11 bytes. Uplink packets use FPORT=2 and (% style="color:#4f81bd" %)**every 20 minutes**(%%) send one uplink by default. 162 162 163 163 After each uplink, the (% style="color:blue" %)**BLUE LED**(%%) will blink once. ... ... @@ -199,7 +199,7 @@ 199 199 * The 8^^th^^ byte: Alarm Bit (if this uplink is from periodically or movement) 200 200 * The 9^^th^^ ~~ 11^^st^^ byte: Movement Detect Count. 201 201 202 -=== 2. 4.1 Decoder in TTN V3 ===267 +=== 2.5.1 Decoder in TTN V3 === 203 203 204 204 205 205 When the uplink payload arrives TTNv3, it shows HEX format and not friendly to read. We can add LHT65N-PIR decoder in TTNv3 for friendly reading. ... ... @@ -210,15 +210,15 @@ 210 210 [[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220522234118-10.png||_mstalt="451464" height="353" width="729"]] 211 211 212 212 213 -=== 2. 4.2 BAT-Battery Info ===278 +=== 2.5.2 BAT-Battery Info === 214 214 215 215 216 216 These two bytes of BAT include the battery state and the actually voltage 217 217 218 -[[image:image-20220523152839-18.png||_mstalt="457613"]] 283 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220523152839-18.png||_mstalt="457613"]] 219 219 220 220 221 -[[image:image-20220522235639-1.png||_mstalt="431392" height="139" width="727"]] 286 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220522235639-1.png||_mstalt="431392" height="139" width="727"]] 222 222 223 223 224 224 Check the battery voltage for LHT65N-PIR. ... ... @@ -226,90 +226,94 @@ 226 226 * BAT status=(0xcba4>>14)&0xFF=11(B),very good 227 227 * Battery Voltage =0xCBF6&0x3FFF=0x0BA4=2980mV 228 228 229 -=== 2. 4.3 Built-in Temperature ===294 +=== 2.5.3 Built-in Temperature === 230 230 296 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220522235639-2.png||_mstalt="431756" height="138" width="722"]] 231 231 232 -[[image:image-20220522235639-2.png||_mstalt="431756" height="138" width="722"]] 233 - 234 234 * Temperature: 0x0ABB/100=27.47℃ 235 235 236 -[[image:image-20220522235639-3.png||_mstalt="432120"]] 300 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220522235639-3.png||_mstalt="432120"]] 237 237 238 238 * Temperature: (0xF5C6-65536)/100=-26.18℃ 239 239 240 -=== 2. 4.4 Built-in Humidity ===304 +=== 2.5.4 Built-in Humidity === 241 241 306 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220522235639-4.png||_mstalt="432484" height="138" width="722"]] 242 242 243 -[[image:image-20220522235639-4.png||_mstalt="432484" height="138" width="722"]] 244 - 245 245 * Humidity: 0x025C/10=60.4% 246 246 247 -=== 2. 4.5 Ext value ===310 +=== 2.5.5 Ext value === 248 248 249 -==== 2. 4.5.1 Ext~=0x05, IlluminanceSensor ====312 +==== 2.5.5.1 Ext~=0x0A, PIR Sensor ==== 250 250 251 - 252 252 [[image:image-20221224161634-2.png||height="138" width="851"]] 253 253 254 254 255 - * Illumination=0x005E=94lux317 +==== 2.5.5.2 Ext Value ==== 256 256 257 -The last2bytesofdataaremeaningless319 +There are 4 bytes in Ext Value field. 258 258 259 - [[image:image-20221224161725-3.png]]321 +Bit0 of byte 8th shows if this uplink is generate by PIR activity. 260 260 261 -* When the sensor is not connected or not connected properly, will show "NULL" 323 +(% border="1" cellspacing="4" style="background-color:#ffffcc; color:green; width:490px" %) 324 +|=(% style="width: 147px;" %)((( 325 +**The 8^^th^^ byte** 326 +)))|=(% style="width: 108px;" %)((( 327 +**Bit 1~~7** 328 +)))|=(% style="width: 228px;" %)((( 329 +**Bit 0** 330 +))) 331 +|(% style="width:147px" %)((( 332 +**Value** 333 +)))|(% style="width:108px" %)((( 334 +Reserve 335 +)))|(% style="width:228px" %)((( 336 +((( 337 +0: Normal Uplink 262 262 263 - The last 2 bytes of data are meaningless 339 +1: Uplink by activity detected 340 +))) 341 +))) 264 264 343 +**Note**: Uplink by activity is disable by default. 265 265 266 -== 2.5 Show data on Datacake == 267 267 346 +The 9^^th^^ ~~ 11^^st^^ byte: Movement Detect Count. 268 268 269 -((( 270 -Datacake IoT platform provides a human-friendly interface to show the sensor data, once we have sensor data in TTN V3, we can use Datacake to connect to TTN V3 and see the data in Datacake. Below are the steps: 271 -))) 348 +0x00 E5 09 : Total detect 58633 activity since end node start. 272 272 273 -((( 274 - 275 -))) 276 276 277 -((( 351 +== 2.6 Show data on Datacake == 352 + 353 +Datacake IoT platform provides a human-friendly interface to show the sensor data, once we have sensor data in TTN V3, we can use Datacake to connect to TTN V3 and see the data in Datacake. Below are the steps: 354 + 278 278 (% style="color:blue" %)**Step 1**(%%): Be sure that your device is programmed and properly connected to the LoRaWAN network. 279 -))) 280 280 281 -((( 282 282 (% style="color:blue" %)**Step 2**(%%): Configure your Application to forward data to Datacake you will need to add integration. Go to TTN V3 Console ~-~-> Applications ~-~-> Integrations ~-~-> Add Integrations. 283 -))) 284 284 285 - 286 - 287 -((( 288 288 Add Datacake: 289 -))) 290 290 361 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220523000825-7.png||_mstalt="429884" height="262" width="583"]] 291 291 292 -[[image:image-20220523000825-7.png||_mstalt="429884" height="262" width="583"]] 293 293 294 294 295 - 296 296 Select default key as Access Key: 297 297 298 298 299 -[[image:image-20220523000825-8.png||_mstalt="430248" height="453" width="406"]] 368 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220523000825-8.png||_mstalt="430248" height="453" width="406"]] 300 300 301 301 302 302 In Datacake console ([[https:~~/~~/datacake.co/>>url:https://datacake.co/]]) , add LHT65 device. 303 303 304 304 305 -[[image:image-20221224161935-5.png||height="523" width="409"]] 374 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20221224161935-5.png||height="523" width="409"]] 306 306 307 307 308 -[[image:image-20221224161957-6.png||height="306" width="852"]] 377 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20221224161957-6.png||height="306" width="852"]] 309 309 310 310 311 311 312 -== 2. 8LED Indicator ==381 +== 2.7 LED Indicator == 313 313 314 314 315 315 The LHT65N-PIR has a triple color LED which for easy showing different stage . ... ... @@ -323,18 +323,20 @@ 323 323 * RED LED when external sensor is not connected 324 324 * For each success downlink, the PURPLE LED will blink once 325 325 326 -== 2. 9installation ==395 +== 2.8 installation == 327 327 397 +~1. Don't install LHT65N-PIR outdoor or place where will get wet 328 328 329 - [[image:image-20220516231650-1.png||_mstalt="428597"height="436"width="428"]]399 +2. Towards the PIR probe to the place where need to monitor activity. 330 330 331 331 402 + 332 332 = 3. Sensors and Accessories = 333 333 334 334 == 3.1 E2 Extension Cable == 335 335 336 336 337 -[[image:image-20220619092222-1.png||_mstalt="429533" height="182" width="188"]][[image:image-20220619092313-2.png||_mstalt="430222" height="182" width="173"]] 408 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220619092222-1.png||_mstalt="429533" height="182" width="188"]][[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220619092313-2.png||_mstalt="430222" height="182" width="173"]] 338 338 339 339 340 340 **1m long breakout cable for LHT65N-E5. Features:** ... ... @@ -346,59 +346,41 @@ 346 346 Update firmware for LHT65N-PIR 347 347 ))) 348 348 349 -[[image:image-20220619092421-3.png||_mstalt="430547" height="371" width="529"]] 420 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220619092421-3.png||_mstalt="430547" height="371" width="529"]] 350 350 351 351 352 -= 4. Configure LHT65N-PIR via AT command or LoRaWAN downlink=423 += 4. Configure LHT65N-PIR = 353 353 425 +== 4.1 Configure Methods: == 354 354 355 -((( 356 -Use can configure LHT65N-E5 via AT Command or LoRaWAN Downlink. 357 -))) 358 358 359 -* ((( 360 -AT Command Connection: See [[FAQ>>||anchor="H6.FAQ"]]. 361 -))) 428 +LHT65N-PIR supports below configure method: 362 362 363 -* ((( 364 -LoRaWAN Downlink instruction for different platforms: [[IoT LoRaWAN Server>>doc:Main.WebHome]] 365 -))) 430 +* AT Command via UART Connection : See [[FAQ>>path:#H7.FAQ]]. 431 +* LoRaWAN Downlink. Instruction for different platforms: See [[IoT LoRaWAN Server>>url:http://wiki.dragino.com/xwiki/bin/view/Main/]] section. 366 366 367 -((( 368 -There are two kinds of commands to configure LHT65N-E5, they are: 369 -))) 433 +== 4.2 General Commands == 370 370 371 -* ((( 372 -(% style="color:#4f81bd" %)**General Commands**. 373 -))) 374 374 375 -((( 376 376 These commands are to configure: 377 -))) 378 378 379 -1. ((( 380 -General system settings like: uplink interval. 381 -))) 382 -1. ((( 383 -LoRaWAN protocol & radio-related commands. 384 -))) 438 +* General system settings like: uplink interval. 439 +* LoRaWAN protocol & radio related command. 385 385 386 -((( 387 -They are the same for all Dragino Devices which supports DLWS-005 LoRaWAN Stack(Note~*~*). These commands can be found on the wiki: [[End Device Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] 388 -))) 441 +They are same for all Dragino Devices which support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki: 389 389 390 -* ((( 391 -(% style="color:#4f81bd" %)**Commands special design for LHT65N-E5** 392 -))) 443 +[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]] 393 393 394 -((( 395 -These commands are only valid for LHT65N-E5, as below: 396 -))) 397 397 446 +== 4.3 Commands special design for LHT65N-PIR == 398 398 399 -== 4.1 Set Transmit Interval Time == 400 400 449 +These commands only valid for LHT65N-PIR, as below: 401 401 451 + 452 +=== 4.3.1 Set Transmit Interval Time === 453 + 454 + 402 402 Feature: Change LoRaWAN End Node Transmit Interval. 403 403 404 404 ... ... @@ -407,7 +407,7 @@ 407 407 [[image:image-20220523150701-2.png||_mstalt="427453"]] 408 408 409 409 410 -(% style="color:#4f81bd" %)**Downlink Command: 0x01**463 +(% style="color:#4f81bd" %)**Downlink Payload: 0x01** 411 411 412 412 Format: Command Code (0x01) followed by 3 bytes time value. 413 413 ... ... @@ -417,9 +417,18 @@ 417 417 418 418 * **Example 2**: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 419 419 420 -== 4.2 CurrentlyonlysupportsE5==473 +=== 4.3.2 Get Device Status === 421 421 475 +Send a LoRaWAN downlink to ask device send Alarm settings. 422 422 477 +* (% style="color:#4f81bd" %)**Downlink Payload**(%%)**: **0x26 01 478 + 479 +Sensor will upload Device Status via FPORT=5. See payload section for detail. 480 + 481 + 482 +=== 4.3.3 Set Password === 483 + 484 + 423 423 Feature: Set device password, max 9 digits 424 424 425 425 ... ... @@ -443,7 +443,7 @@ 443 443 444 444 * 0xA205: Set external sensor type to E5 445 445 446 -== 4.3 Set to sleep mode == 508 +=== 4.3.4 Set to sleep mode === 447 447 448 448 449 449 Feature: Set device to sleep mode ... ... @@ -460,206 +460,60 @@ 460 460 461 461 * There is no downlink command to set to Sleep mode. 462 462 463 -= 5.Battery&Howtoreplace=525 +=== 4.3.5 Set UOA (Uplink on Activity) === 464 464 465 - ==5.1BatteryType==527 +Feature: Enable / Disable Uplink on Activity 466 466 529 +* **AT+UOA=0** : Disable UoA 530 +* **AT+UOA=1,2** : Enable UoA , Calm Down Time: 2 minutes. If device already send a uplink on activity, it will not send another uplink on activiy in 2 minutes, even detect activity. 467 467 468 -((( 469 -LHT65N-E5 is equipped with a 2400mAH Li-MnO2 (CR17505) battery . The battery is an un-rechargeable battery with low discharge rate targeting for up to 8~~10 years use. This type of battery is commonly used in IoT devices for long-term running, such as water meters. 470 -))) 532 +Notice: Calm Down time range is 1 ~~ 65535 minutes. If user set Calm Down time to low value, such as 1 minute, the sensor might send uplink very frequenctly and battery drain fast. 471 471 472 -((( 473 -The discharge curve is not linear so can't simply use percentage to show the battery level. Below is the battery performance. 534 +(% style="color:#4f81bd" %)**AT Command: AT+UOA** 474 474 475 475 476 -[[image:image-20220515075034-1.png||_mstalt="428961" height="208" width="644"]] 477 -))) 537 +(% style="color:#4f81bd" %)**Downlink Command: **(% class="mark" %)**xxxxxxx** 478 478 479 -The minimum Working Voltage for the LHT65N-E5 is ~~ 2.5v. When battery is lower than 2.6v, it is time to change the battery. 480 - 481 481 482 -= =5.2ReplaceBattery ==540 += 5. Battery & Power Consumption = 483 483 542 +LHT65N-PIR use **CR17450** battery pack. See below link for detail information about the battery info and how to replace. 484 484 485 - LHT65N-E5 hastwo screwsontheback, Unscrewthem,and changingthe batteryinsideisok.Thebatteryis a generalCR17450(3.0v). Any brand should bek.544 +[[**Battery Info & Power Consumption Analyze**>>url:http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20calculate%20the%20battery%20life%20of%20Dragino%20sensors%3F/]] . 486 486 487 -[[image:image-20220515075440-2.png||_mstalt="429546" height="338" width="272"]][[image:image-20220515075625-3.png||_mstalt="431574" height="193" width="257"]] 488 488 547 += 6. OTA firmware update = 489 489 490 - ==5.3BatteryLifeAnalyze==549 +Please see this link for how to do OTA firmware update: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/]] 491 491 492 492 493 -((( 494 -Dragino battery-powered products are all run in Low Power mode. User can check the guideline from this link to calculate the estimated battery life: 495 -[[https:~~/~~/www.dragino.com/downloads/downloads/LoRa_End_Node/Battery_Analyze/DRAGINO_Battery_Life_Guide.pdf>>https://www.dragino.com/downloads/downloads/LoRa_End_Node/Battery_Analyze/DRAGINO_Battery_Life_Guide.pdf]] 496 -))) 552 += 7. FAQ = 497 497 554 +== 7.1 How to use AT Command? == 498 498 499 -((( 500 -A full detail test report for LHT65N-E5 on different frequency can be found at : [[https:~~/~~/www.dropbox.com/sh/r2i3zlhsyrpavla/AAB1sZw3mdT0K7XjpHCITt13a?dl=0>>https://www.dropbox.com/sh/r2i3zlhsyrpavla/AAB1sZw3mdT0K7XjpHCITt13a?dl=0]] 501 -))) 502 502 503 - 504 -= 6. FAQ = 505 - 506 -== 6.1 How to use AT Command? == 507 - 508 - 509 509 LHT65N-E5 supports AT Command set.User can use a USB to TTL adapter plus the Program Cable to connect to LHT65 for using AT command, as below. 510 510 511 511 512 -[[image:image-20220615153355-1.png||_mstalt="430222"]] 560 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615153355-1.png||_mstalt="430222"]] 513 513 514 514 515 515 516 -[[image:1655802313617-381.png||_mstalt="293917"]] 564 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@1655802313617-381.png||_mstalt="293917"]] 517 517 518 518 519 - 520 -((( 521 521 In PC, User needs to set serial tool(such as [[**putty**>>https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to (% style="color:green" %)**9600** (%%)to access to access serial console for LHT65N-E5. The AT commands are disable by default and need to enter password (default:(% style="color:green" %)**123456**(% style="color:red" %))(%%) to active it. Timeout to input AT Command is 5 min, after 5-minute, user need to input password again. User can use AT+DISAT command to disable AT command before timeout. 522 -))) 523 523 524 -[[image:image-20220615154519-3.png||_mstalt="431925" height="672" width="807"]] 569 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615154519-3.png||_mstalt="431925" height="672" width="807"]] 525 525 526 -AT Command List is as below: 527 527 528 -AT+<CMD>? : Help on <CMD> 529 529 530 - AT+<CMD>:Run<CMD>573 +== 7.2 Where to use AT commands and Downlink commands == 531 531 532 -AT+<CMD>=<value> : Set the value 533 533 534 -AT+<CMD>=? : Get the value 535 - 536 -AT+DEBUG: Set more info output 537 - 538 -ATZ: Trig a reset of the MCU 539 - 540 -AT+FDR: Reset Parameters to Factory Default, Keys Reserve 541 - 542 -AT+DEUI: Get or Set the Device EUI 543 - 544 -AT+DADDR: Get or Set the Device Address 545 - 546 -AT+APPKEY: Get or Set the Application Key 547 - 548 -AT+NWKSKEY: Get or Set the Network Session Key 549 - 550 -AT+APPSKEY: Get or Set the Application Session Key 551 - 552 -AT+APPEUI: Get or Set the Application EUI 553 - 554 -AT+ADR: Get or Set the Adaptive Data Rate setting. (0: off, 1: on) 555 - 556 -AT+TXP: Get or Set the Transmit Power (0-5, MAX:0, MIN:5, according to LoRaWAN Spec) 557 - 558 -AT+DR: Get or Set the Data Rate. (0-7 corresponding to DR_X) 559 - 560 -AT+DCS: Get or Set the ETSI Duty Cycle setting - 0=disable, 1=enable - Only for testing 561 - 562 -AT+PNM: Get or Set the public network mode. (0: off, 1: on) 563 - 564 -AT+RX2FQ: Get or Set the Rx2 window frequency 565 - 566 -AT+RX2DR: Get or Set the Rx2 window data rate (0-7 corresponding to DR_X) 567 - 568 -AT+RX1DL: Get or Set the delay between the end of the Tx and the Rx Window 1 in ms 569 - 570 -AT+RX2DL: Get or Set the delay between the end of the Tx and the Rx Window 2 in ms 571 - 572 -AT+JN1DL: Get or Set the Join Accept Delay between the end of the Tx and the Join Rx Window 1 in ms 573 - 574 -AT+JN2DL: Get or Set the Join Accept Delay between the end of the Tx and the Join Rx Window 2 in ms 575 - 576 -AT+NJM: Get or Set the Network Join Mode. (0: ABP, 1: OTAA) 577 - 578 -AT+NWKID: Get or Set the Network ID 579 - 580 -AT+FCU: Get or Set the Frame Counter Uplink 581 - 582 -AT+FCD: Get or Set the Frame Counter Downlink 583 - 584 -AT+CLASS: Get or Set the Device Class 585 - 586 -AT+JOIN: Join network 587 - 588 -AT+NJS: Get the join status 589 - 590 -AT+SENDB: Send hexadecimal data along with the application port 591 - 592 -AT+SEND: Send text data along with the application port 593 - 594 -AT+RECVB: Print last received data in binary format (with hexadecimal values) 595 - 596 -AT+RECV: Print last received data in raw format 597 - 598 -AT+VER: Get current image version and Frequency Band 599 - 600 -AT+CFM: Get or Set the confirmation mode (0-1) 601 - 602 -AT+CFS: Get confirmation status of the last AT+SEND (0-1) 603 - 604 -AT+SNR: Get the SNR of the last received packet 605 - 606 -AT+RSSI: Get the RSSI of the last received packet 607 - 608 -AT+TDC: Get or set the application data transmission interval in ms 609 - 610 -AT+PORT: Get or set the application port 611 - 612 -AT+DISAT: Disable AT commands 613 - 614 -AT+PWORD: Set password, max 9 digits 615 - 616 -AT+CHS: Get or Set Frequency (Unit: Hz) for Single Channel Mode 617 - 618 -AT+CHE: Get or Set eight channels mode,Only for US915,AU915,CN470 619 - 620 -AT+PDTA: Print the sector data from start page to stop page 621 - 622 -AT+PLDTA: Print the last few sets of data 623 - 624 -AT+CLRDTA: Clear the storage, record position back to 1st 625 - 626 -AT+SLEEP: Set sleep mode 627 - 628 -AT+EXT: Get or Set external sensor model 629 - 630 -AT+BAT: Get the current battery voltage in mV 631 - 632 -AT+CFG: Print all configurations 633 - 634 -AT+WMOD: Get or Set Work Mode 635 - 636 -AT+ARTEMP: Get or set the internal Temperature sensor alarm range 637 - 638 -AT+CITEMP: Get or set the internal Temperature sensor collection interval in min 639 - 640 -AT+SETCNT: Set the count at present 641 - 642 -AT+RJTDC: Get or set the ReJoin data transmission interval in min 643 - 644 -AT+RPL: Get or set response level 645 - 646 -AT+TIMESTAMP: Get or Set UNIX timestamp in second 647 - 648 -AT+LEAPSEC: Get or Set Leap Second 649 - 650 -AT+SYNCMOD: Get or Set time synchronization method 651 - 652 -AT+SYNCTDC: Get or set time synchronization interval in day 653 - 654 -AT+PID: Get or set the PID 655 - 656 - 657 -== 6.2 Where to use AT commands and Downlink commands == 658 - 659 - 660 660 **AT commands:** 661 661 662 -[[image:image-20220620153708-1.png||_mstalt="429806" height="603" width="723"]] 578 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220620153708-1.png||_mstalt="429806" height="603" width="723"]] 663 663 664 664 665 665 **Downlink commands:** ... ... @@ -668,13 +668,13 @@ 668 668 669 669 (% style="color:blue" %)**TTN:** 670 670 671 -[[image:image-20220615092124-2.png||_mstalt="429221" height="649" width="688"]] 587 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615092124-2.png||_mstalt="429221" height="649" width="688"]] 672 672 673 673 674 674 675 675 (% style="color:blue" %)**Helium:** 676 676 677 -[[image:image-20220615092551-3.png||_mstalt="430794" height="423" width="835"]] 593 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615092551-3.png||_mstalt="430794" height="423" width="835"]] 678 678 679 679 680 680 ... ... @@ -681,56 +681,49 @@ 681 681 (% style="color:blue" %)**Chirpstack: The downlink window will not be displayed until the network is accessed** 682 682 683 683 684 -[[image:image-20220615094850-6.png||_mstalt="433082"]] 600 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615094850-6.png||_mstalt="433082"]] 685 685 686 686 687 -[[image:image-20220615094904-7.png||_mstalt="433485" height="281" width="911"]] 603 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615094904-7.png||_mstalt="433485" height="281" width="911"]] 688 688 689 689 690 690 691 691 (% style="color:blue" %)**Aws:** 692 692 693 -[[image:image-20220615092939-4.png||_mstalt="434460" height="448" width="894"]] 609 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615092939-4.png||_mstalt="434460" height="448" width="894"]] 694 694 695 695 696 696 == 6.3 How to change the uplink interval? == 697 697 698 - 699 699 Please see this link: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/How%20to%20set%20the%20transmit%20time%20interval/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20set%20the%20transmit%20time%20interval/||_mstmutation="1" style="background-color: rgb(255, 255, 255);"]] 700 700 616 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615154519-3.png||_mstalt="431925" height="672" width="807"]] 701 701 702 702 703 - [[image:image-20220615154519-3.png||_mstalt="431925"height="672"width="807"]]619 +== 7.4 How to use TTL-USB to connect PC to upgrade firmware? == 704 704 621 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615153355-1.png||_mstalt="430222"]] 705 705 706 -== 6.4 How to use TTL-USB to connect PC to upgrade firmware? == 707 - 708 - 709 -[[image:image-20220615153355-1.png||_mstalt="430222"]] 710 - 711 - 712 712 (% style="color:blue" %)**Step1**(%%): Install TremoProgrammer first. 713 713 714 -[[image:image-20220615170542-5.png||_mstalt="430638"]] 625 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615170542-5.png||_mstalt="430638"]] 715 715 716 - 717 - 718 718 (% _mstmutation="1" style="color:blue" %)**Step2**(%%):wiring method.(% style="display:none" %) 719 719 720 720 First connect the four lines;(% style="display:none" %) 721 721 722 -[[image:image-20220621170938-1.png||_mstalt="431340" height="413" width="419"]],(% style="display:none" %) 631 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220621170938-1.png||_mstalt="431340" height="413" width="419"]],(% style="display:none" %) 723 723 724 724 725 725 Then use DuPont cable to short circuit port3 and port1, and then release them, so that the device enters bootlaod mode. 726 726 727 -[[image:image-20220621170938-2.png||_mstalt="431704"]] 636 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220621170938-2.png||_mstalt="431704"]] 728 728 729 729 730 730 731 731 (% style="color:blue" %)**Step3:**(%%)Select the device port to be connected, baud rate and bin file to be downloaded. 732 732 733 -[[image:image-20220615171334-6.png||_mstalt="431028"]] 642 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615171334-6.png||_mstalt="431028"]] 734 734 735 735 736 736 Click the (% style="color:blue" %)**start**(%%) button to start the firmware upgrade. ... ... @@ -738,7 +738,7 @@ 738 738 739 739 When this interface appears, it indicates that the download has been completed. 740 740 741 -[[image:image-20220620160723-8.png||_mstalt="430703"]] 650 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220620160723-8.png||_mstalt="430703"]] 742 742 743 743 744 744 Finally, unplug the DuPont cable on port4, and then use the DuPont cable to short circuit port3 and port1 to reset the device. ... ... @@ -745,10 +745,10 @@ 745 745 746 746 747 747 748 -[[image:image-20220615154519-3.png||_mstalt="431925" height="672" width="807"]] 657 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615154519-3.png||_mstalt="431925" height="672" width="807"]] 749 749 750 750 751 -= 7. Order Info =660 += 8. Order Info = 752 752 753 753 754 754 Part Number: (% style="color:#4f81bd" %)** LHT65N-PIR-XX** ... ... @@ -764,7 +764,7 @@ 764 764 * (% style="color:#4f81bd" %)** **(% _mstmutation="1" style="color:red" %)**IN865**(%%): LoRaWAN IN865 band 765 765 * (% style="color:#4f81bd" %)** **(% _mstmutation="1" style="color:red" %)**CN470**(%%): LoRaWAN CN470 band 766 766 767 -= 8. Packing Info =676 += 9. Packing Info = 768 768 769 769 770 770 **Package Includes**: ... ... @@ -776,12 +776,12 @@ 776 776 * Device Size: 10 x 10 x 3.5 mm 777 777 * Device Weight: 120.5g 778 778 779 -= 9. Reference material =688 += 10. Reference material = 780 780 781 781 782 782 * [[Datasheet, photos, decoder, firmware>>https://www.dropbox.com/sh/una19zsni308dme/AACOKp6J2RF5TMlKWT5zU3RTa?dl=0]] 783 783 784 -= 1 0. FCC Warning =693 += 11. FCC Warning = 785 785 786 786 787 787 This device complies with part 15 of the FCC Rules.Operation is subject to the following two conditions: