Changes for page LHT65N-PIR Temperature/Humidity/PIR Motion Sensor User Manual
Last modified by Xiaoling on 2025/04/24 10:00
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -131,7 +131,7 @@ 131 131 Add APP EUI in the application. 132 132 133 133 134 -[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220522232916-3.png||_mstalt="430495" alt="image-20220522232916-3.png"]]134 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220522232916-3.png||_mstalt="430495"]] 135 135 136 136 137 137 [[image:image-20220522232932-4.png||_mstalt="430157"]] ... ... @@ -195,9 +195,9 @@ 195 195 ))) 196 196 197 197 * The First 6 bytes: has fix meanings for every LHT65N-PIR. 198 -* The 7th byte (EXT #): defines the external sensor model. It can be (% class="mark" %)0x05or 0x09(%%)for LHT65N-PIR199 -* The 7^^th^^ byte: Alarm Bit (if this uplink is from periodically or movement)200 -* The 8^^th^^ ~~ 11st byte: Movement Detect Count.198 +* The 7th byte (EXT #): defines the external sensor model. It can be 0x0A for LHT65N-PIR 199 +* The 8^^th^^ byte: Alarm Bit (if this uplink is from periodically or movement) 200 +* The 9^^th^^ ~~ 11^^st^^ byte: Movement Detect Count. 201 201 202 202 === 2.4.1 Decoder in TTN V3 === 203 203 ... ... @@ -207,7 +207,7 @@ 207 207 Below is the position to put the decoder and LHT65N-PIR decoder can be download from here: [[https:~~/~~/github.com/dragino/dragino-end-node-decoder>>https://github.com/dragino/dragino-end-node-decoder]] 208 208 209 209 210 -[[image:image-20220522234118-10.png||_mstalt="451464" height="353" width="729"]] 210 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220522234118-10.png||_mstalt="451464" height="353" width="729"]] 211 211 212 212 213 213 === 2.4.2 BAT-Battery Info === ... ... @@ -215,10 +215,10 @@ 215 215 216 216 These two bytes of BAT include the battery state and the actually voltage 217 217 218 -[[image:image-20220523152839-18.png||_mstalt="457613"]] 218 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220523152839-18.png||_mstalt="457613"]] 219 219 220 220 221 -[[image:image-20220522235639-1.png||_mstalt="431392" height="139" width="727"]] 221 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220522235639-1.png||_mstalt="431392" height="139" width="727"]] 222 222 223 223 224 224 Check the battery voltage for LHT65N-PIR. ... ... @@ -228,67 +228,73 @@ 228 228 229 229 === 2.4.3 Built-in Temperature === 230 230 231 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220522235639-2.png||_mstalt="431756" height="138" width="722"]] 231 231 232 -[[image:image-20220522235639-2.png||_mstalt="431756" height="138" width="722"]] 233 - 234 234 * Temperature: 0x0ABB/100=27.47℃ 235 235 236 -[[image:image-20220522235639-3.png||_mstalt="432120"]] 235 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220522235639-3.png||_mstalt="432120"]] 237 237 238 238 * Temperature: (0xF5C6-65536)/100=-26.18℃ 239 239 239 + 240 240 === 2.4.4 Built-in Humidity === 241 241 242 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220522235639-4.png||_mstalt="432484" height="138" width="722"]] 242 242 243 -[[image:image-20220522235639-4.png||_mstalt="432484" height="138" width="722"]] 244 - 245 245 * Humidity: 0x025C/10=60.4% 246 246 246 + 247 247 === 2.4.5 Ext value === 248 248 249 -==== 2.4.5.1 Ext~=0x0 5, IlluminanceSensor ====249 +==== 2.4.5.1 Ext~=0x0A, PIR Sensor ==== 250 250 251 - 252 252 [[image:image-20221224161634-2.png||height="138" width="851"]] 253 253 254 254 255 - * Illumination=0x005E=94 lux254 +==== 2.4.5.2 Ext Value ==== 256 256 257 -The last2bytesofdataaremeaningless256 +There are 4 bytes in Ext Value field. 258 258 259 - [[image:image-20221224161725-3.png]]258 +Bit0 of byte 8th shows if this uplink is generate by PIR activity. 260 260 261 -* When the sensor is not connected or not connected properly, will show "NULL" 260 +(% border="1" cellspacing="4" style="background-color:#ffffcc; color:green; width:490px" %) 261 +|=(% style="width: 147px;" %)((( 262 +**The 8^^th^^ bytes** 263 +)))|=(% style="width: 108px;" %)((( 264 +**Bit 1~~7** 265 +)))|=(% style="width: 228px;" %)((( 266 +**Bit 0** 267 +))) 268 +|(% style="width:147px" %)((( 269 +**Value** 270 +)))|(% style="width:108px" %)((( 271 +Reserve 272 +)))|(% style="width:228px" %)((( 273 +((( 274 +0: Normal Uplink 262 262 263 - The last 2 bytes of data are meaningless 276 +1: Uplink by activity detected 277 +))) 278 +))) 264 264 280 +**Note**: Uplink by activity is disable by default. 265 265 266 -== 2.5 Show data on Datacake == 267 267 283 +The 9^^th^^ ~~ 11^^st^^ byte: Movement Detect Count. 268 268 269 -((( 270 -Datacake IoT platform provides a human-friendly interface to show the sensor data, once we have sensor data in TTN V3, we can use Datacake to connect to TTN V3 and see the data in Datacake. Below are the steps: 271 -))) 285 +0x00 E5 09 : Total detect 58633 activity since end node start. 272 272 273 -((( 274 - 275 -))) 276 276 277 -((( 288 +== 2.5 Show data on Datacake == 289 + 290 +Datacake IoT platform provides a human-friendly interface to show the sensor data, once we have sensor data in TTN V3, we can use Datacake to connect to TTN V3 and see the data in Datacake. Below are the steps: 291 + 278 278 (% style="color:blue" %)**Step 1**(%%): Be sure that your device is programmed and properly connected to the LoRaWAN network. 279 -))) 280 280 281 -((( 282 282 (% style="color:blue" %)**Step 2**(%%): Configure your Application to forward data to Datacake you will need to add integration. Go to TTN V3 Console ~-~-> Applications ~-~-> Integrations ~-~-> Add Integrations. 283 -))) 284 284 285 - 286 - 287 -((( 288 288 Add Datacake: 289 -))) 290 290 291 - 292 292 [[image:image-20220523000825-7.png||_mstalt="429884" height="262" width="583"]] 293 293 294 294 ... ... @@ -460,7 +460,6 @@ 460 460 461 461 * There is no downlink command to set to Sleep mode. 462 462 463 - 464 464 = 5. Battery & How to replace = 465 465 466 466 == 5.1 Battery Type ==