Changes for page LHT65N-PIR Temperature/Humidity/PIR Motion Sensor User Manual
Last modified by Xiaoling on 2025/06/10 09:17
From version 57.1
edited by Xiaoling
on 2025/06/09 17:59
on 2025/06/09 17:59
Change comment:
There is no comment for this version
To version 47.1
edited by Bei Jinggeng
on 2023/10/31 17:15
on 2023/10/31 17:15
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 6 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Xiaoling1 +XWiki.Bei - Content
-
... ... @@ -1,4 +1,5 @@ 1 -[[image:LHT65N-PIR1.jpg||alt="image-20221206143242-2.png" data-xwiki-image-style-alignment="center" height="484" width="485"]] 1 +(% style="text-align:center" %) 2 +[[image:LHT65N-PIR1.jpg||alt="image-20221206143242-2.png" height="484" width="485"]] 2 2 3 3 4 4 ... ... @@ -60,7 +60,7 @@ 60 60 61 61 * Resolution: 0.04 %RH 62 62 * Accuracy Tolerance : Typ ±3 %RH 63 -* Long Term Drift: < 0.2 5RH/yr64 +* Long Term Drift: < 0.02 °C/yr 64 64 * Operating Range: 0 ~~ 96 %RH 65 65 66 66 (% style="color:#037691" %)**External PIR Sensor:** ... ... @@ -95,15 +95,15 @@ 95 95 96 96 97 97 (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 98 -|=(% style="width: 167px;background-color:# 4F81BD;color:white" %)**Behavior on ACT**|=(% style="width: 117px;background-color:#4F81BD;color:white" %)**Function**|=(% style="width: 226px;background-color:#4F81BD;color:white" %)**Action**99 -| [[image:1749461670222-301.png||height="31"width="25"]] [[image:1749461680536-405.png||height="25"width="25"]]1~~3s|(% style="background-color:#f2f2f2; width:117px" %)Test uplink status|(% style="background-color:#f2f2f2; width:225px" %)(((100 -If LHT65N-PIR is already Joined to rhe LoRaWAN network, LHT65N-PIR will send an uplink packet, if LHT65N-PIR has external sensor connected,Blue led 99 +|=(% style="width: 167px;background-color:#D9E2F3;color:#0070C0" %)**Behavior on ACT**|=(% style="width: 117px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 225px;background-color:#D9E2F3;color:#0070C0" %)**Action** 100 +|(% style="background-color:#f2f2f2; width:167px" %)Pressing ACT between 1s < time < 3s|(% style="background-color:#f2f2f2; width:117px" %)Test uplink status|(% style="background-color:#f2f2f2; width:225px" %)((( 101 +If LHT65N-PIR is already Joined to rhe LoRaWAN network, LHT65N-PIR will send an uplink packet, if LHT65N-PIR has external sensor connected,(% style="color:blue" %)**Blue led** (%%)will blink once. If LHT65N-PIR has not external sensor, (% style="color:red" %)**Red led**(%%) will blink once. 101 101 ))) 102 -| [[image:1749461668318-290.png||height="31"width="25"]] [[image:1749461678661-687.png||height="25"width="25"]]>3s|(% style="background-color:#f2f2f2; width:117px" %)Active Device|(% style="background-color:#f2f2f2; width:225px" %)(((103 -Green led will fast blink 5 times, LHT65N-PIR will enter working mode and start to JOIN LoRaWAN network. 104 -Green led will solidly turn on for 5 seconds after join in network. 103 +|(% style="background-color:#f2f2f2; width:167px" %)Pressing ACT for more than 3s|(% style="background-color:#f2f2f2; width:117px" %)Active Device|(% style="background-color:#f2f2f2; width:225px" %)((( 104 +(% style="background-color:#f2f2f2; color:green" %)**Green led**(%%) will fast blink 5 times, LHT65N-PIR will enter working mode and start to JOIN LoRaWAN network. 105 +(% style="background-color:#f2f2f2; color:green" %)**Green led**(%%) will solidly turn on for 5 seconds after join in network. 105 105 ))) 106 -| [[image:1749461666511-624.png||height="31"width="25"]]x5|(% style="background-color:#f2f2f2; width:117px" %)Deactivate Device|(% style="background-color:#f2f2f2; width:225px" %)Red led will solid on for 5 seconds. Means LHT65N-PIR is in Deep Sleep Mode.107 +|(% style="background-color:#f2f2f2; width:167px" %)Fast press ACT 5 times.|(% style="background-color:#f2f2f2; width:117px" %)Deactivate Device|(% style="background-color:#f2f2f2; width:225px" %)(% style="color:red" %)**Red led**(%%) will solid on for 5 seconds. Means LHT65N-PIR is in Deep Sleep Mode. 107 107 108 108 == 2.3 Example to join LoRaWAN network == 109 109 ... ... @@ -131,51 +131,39 @@ 131 131 132 132 User can enter these keys in the LoRaWAN Server portal. Below is TTN V3 screenshot: 133 133 134 - **~1.Create application**135 +Add APP EUI in the application. 135 135 136 -[[image:https://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/WebHome/image-20250424091200-1.jpeg?rev=1.1||alt="image-20250424091200-1.jpeg"]] 137 137 138 -[[image: https://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/WebHome/image-20250424091207-2.jpeg?rev=1.1||alt="image-20250424091207-2.jpeg"]]138 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220522232916-3.png||_mstalt="430495"]] 139 139 140 140 141 - **2.AddevicestothecreatedApplication.**141 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N-E5%20LoRaWAN%20Temperature_Humidity%20%26%20Illuminance%20Sensor%20User%20Manual/WebHome/image-20220522232932-4.png?rev=1.1||alt="image-20220522232932-4.png"]] 142 142 143 -[[image:https://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/WebHome/image-20250424091404-3.jpeg?rev=1.1||alt="image-20250424091404-3.jpeg"]] 144 144 145 -[[image:http s://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/WebHome/image-20250424091412-4.jpeg?rev=1.1||alt="image-20250424091412-4.jpeg"]]144 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N-E5%20LoRaWAN%20Temperature_Humidity%20%26%20Illuminance%20Sensor%20User%20Manual/WebHome/image-20220522232954-5.png?rev=1.1||alt="image-20220522232954-5.png"]] 146 146 147 147 148 - **3.Enternddevice specificsmanually.**147 +(% style="color:red" %)**Note: LHT65N-PIR use same payload decoder as LHT65.** 149 149 150 -[[image:https://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/WebHome/image-20250424091458-5.jpeg?rev=1.1||alt="image-20250424091458-5.jpeg"]] 151 151 152 -[[image:http s://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/WebHome/image-20250424091509-6.jpeg?rev=1.1||alt="image-20250424091509-6.jpeg"]]150 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N-E5%20LoRaWAN%20Temperature_Humidity%20%26%20Illuminance%20Sensor%20User%20Manual/WebHome/image-20220522233026-6.png?rev=1.1||alt="image-20220522233026-6.png"]] 153 153 154 154 155 - === 2.3.2 Step2:Adddecoder===153 +**Input APP EUI, APP KEY and DEV EUI:** 156 156 155 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N-E5%20LoRaWAN%20Temperature_Humidity%20%26%20Illuminance%20Sensor%20User%20Manual/WebHome/image-20220522233118-7.png?rev=1.1||alt="image-20220522233118-7.png"]] 157 157 158 -In TTN, user can add a custom payload so it shows friendly reading. 159 159 160 - Clickthislinkto getthedecoder: [[https:~~/~~/github.com/dragino/dragino-end-node-decoder/tree/main/>>url:https://github.com/dragino/dragino-end-node-decoder/tree/main/]]158 +=== 2.3.2 Step 2: Activate LHT65N-PIR by pressing the ACT button for more than 5 seconds. === 161 161 162 -Below is TTN screen shot 163 163 164 -[[image:https://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LWL04--LoRaWAN_Water_Leak_Sensor_User_Manual/WebHome/image-20240909162501-5.png?width=1084&height=516&rev=1.1||alt="image-20240909162501-5.png"]] 165 - 166 -[[image:https://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LWL04--LoRaWAN_Water_Leak_Sensor_User_Manual/WebHome/image-20240909162647-6.png?width=1086&height=494&rev=1.1||alt="image-20240909162647-6.png"]] 167 - 168 - 169 -=== 2.3.3 Step 3: Activate LHT65N-PIR by pressing the ACT button for more than 5 seconds. === 170 - 171 - 172 172 Use ACT button to activate LHT65N-PIR and it will auto-join to the TTN V3 network. After join success, it will start to upload sensor data to TTN V3 and user can see in the panel. 173 173 174 -[[image:image-20250424095841-1.jpeg]] 175 175 164 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N-E5%20LoRaWAN%20Temperature_Humidity%20%26%20Illuminance%20Sensor%20User%20Manual/WebHome/image-20220522233300-8.png?rev=1.1||alt="image-20220522233300-8.png"]] 176 176 177 177 178 -== 2.4 Uplink Payload~-~-Device Status, (Fport~=5) (%style="display:none" %) (%%)==167 +== 2.4 Uplink Payload~-~-Device Status, (Fport~=5) == 179 179 180 180 181 181 Users can use the downlink command(**0x26 01**) to ask LHT65N-PIR to send device configure detail, include device configure status. LHT65N-PIR will uplink a payload via FPort=5 to server. ... ... @@ -183,13 +183,13 @@ 183 183 The Payload format is as below. 184 184 185 185 (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 186 -|(% colspan="6" style="background-color:# 4f81bd; color:white" %)**Device Status (FPORT=5)**175 +|(% colspan="6" style="background-color:#d9e2f3; color:#0070c0" %)**Device Status (FPORT=5)** 187 187 |(% style="background-color:#f2f2f2; width:103px" %)**Size (bytes)**|(% style="background-color:#f2f2f2; width:72px" %)**1**|(% style="background-color:#f2f2f2" %)**2**|(% style="background-color:#f2f2f2; width:91px" %)**1**|(% style="background-color:#f2f2f2; width:86px" %)**1**|(% style="background-color:#f2f2f2; width:44px" %)**2** 188 -|(% style="background-color:#f2f2f2; width:103px" %)Value|(% style="background-color:#f2f2f2; width:72px" %)Sensor Model|(% style="background-color:#f2f2f2" %)Firmware Version|(% style="background-color:#f2f2f2; width:91px" %)Frequency Band|(% style="background-color:#f2f2f2; width:86px" %)Sub-band|(% style="background-color:#f2f2f2; width:44px" %)BAT 177 +|(% style="background-color:#f2f2f2; width:103px" %)**Value**|(% style="background-color:#f2f2f2; width:72px" %)Sensor Model|(% style="background-color:#f2f2f2" %)Firmware Version|(% style="background-color:#f2f2f2; width:91px" %)Frequency Band|(% style="background-color:#f2f2f2; width:86px" %)Sub-band|(% style="background-color:#f2f2f2; width:44px" %)BAT 189 189 190 190 Example parse in TTNv3 191 191 192 -[[image:image-20230508151932-1.png ||height="213" width="1245"]]181 +[[image:image-20230508151932-1.png]] 193 193 194 194 195 195 (% style="color:blue" %)**Sensor Model**(%%): For LHT65N-PIR, this value is 0x1A ... ... @@ -253,17 +253,17 @@ 253 253 After each uplink, the (% style="color:blue" %)**BLUE LED**(%%) will blink once. 254 254 255 255 (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:390px" %) 256 -|=(% style="width: 60px;background-color:# 4F81BD;color:white" %)(((245 +|=(% style="width: 60px;background-color:#D9E2F3;color:#0070C0" %)((( 257 257 **Size(bytes)** 258 -)))|=(% style="width: 30px;background-color:# 4F81BD;color:white" %)(((247 +)))|=(% style="width: 30px;background-color:#D9E2F3;color:#0070C0" %)((( 259 259 **2** 260 -)))|=(% style="width: 100px;background-color:# 4F81BD;color:white" %)(((249 +)))|=(% style="width: 100px;background-color:#D9E2F3;color:#0070C0" %)((( 261 261 **2** 262 -)))|=(% style="width: 100px;background-color:# 4F81BD;color:white" %)(((251 +)))|=(% style="width: 100px;background-color:#D9E2F3;color:#0070C0" %)((( 263 263 **2** 264 -)))|=(% style="width: 50px;background-color:# 4F81BD;color:white" %)(((253 +)))|=(% style="width: 50px;background-color:#D9E2F3;color:#0070C0" %)((( 265 265 **1** 266 -)))|=(% style="width: 50px;background-color:# 4F81BD;color:white" %)(((255 +)))|=(% style="width: 50px;background-color:#D9E2F3;color:#0070C0" %)((( 267 267 **4** 268 268 ))) 269 269 |(% style="width:97px" %)((( ... ... @@ -306,9 +306,9 @@ 306 306 These two bytes of BAT include the battery state and the actually voltage 307 307 308 308 (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:477px" %) 309 -|=(% style="width: 69px; background-color:# 4F81BD;color:white" %)(((298 +|=(% style="width: 69px; background-color:#D9E2F3;color:#0070C0" %)((( 310 310 **Bit(bit)** 311 -)))|=(% style="width: 253px;background-color:# 4F81BD;color:white" %)[15:14]|=(% style="width: 155px;background-color:#4F81BD;color:white" %)[13:0]300 +)))|=(% style="width: 253px;background-color:#D9E2F3;color:#0070C0" %)[15:14]|=(% style="width: 155px;background-color:#D9E2F3;color:#0070C0" %)[13:0] 312 312 |(% style="width:66px" %)((( 313 313 Value 314 314 )))|(% style="width:250px" %)((( ... ... @@ -350,7 +350,7 @@ 350 350 ==== 2.5.5.1 Ext~=0x0E, PIR Sensor ==== 351 351 352 352 353 -[[image:ext=14.png||alt="image-20221224161634-2.png" height="166" width="1252"]]342 +[[image:ext=14.png||alt="image-20221224161634-2.png"]] 354 354 355 355 356 356 ==== 2.5.5.2 Ext Value ==== ... ... @@ -361,15 +361,15 @@ 361 361 Bit0 of byte 8th shows if this uplink is generate by PIR activity. 362 362 363 363 (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:393px" %) 364 -|=(% style="width: 107px; background-color:# 4F81BD;color:white" %)(((353 +|=(% style="width: 107px; background-color:#D9E2F3;color:#0070C0" %)((( 365 365 **The 8^^th^^ byte** 366 -)))|=(% style="width: 73px; background-color:# 4F81BD;color:white" %)(((355 +)))|=(% style="width: 73px; background-color:#D9E2F3;color:#0070C0" %)((( 367 367 **Bit 1~~7** 368 -)))|=(% style="width: 213px; background-color:# 4F81BD;color:white" %)(((357 +)))|=(% style="width: 213px; background-color:#D9E2F3;color:#0070C0" %)((( 369 369 **Bit 0** 370 370 ))) 371 371 |(% style="width:106px" %)((( 372 -Value 361 +**Value** 373 373 )))|(% style="width:71px" %)((( 374 374 Reserve 375 375 )))|(% style="width:211px" %)((( ... ... @@ -386,6 +386,7 @@ 386 386 0x00 E5 09 : Total detect 58633 activity since end node start. 387 387 388 388 378 + 389 389 == 2.6 Show data on Datacake == 390 390 391 391 ... ... @@ -415,7 +415,6 @@ 415 415 416 416 [[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20221224161957-6.png||height="306" width="852"]] 417 417 418 - 419 419 == 2.7 Alarm Mode & Feature "Multi sampling, one uplink" == 420 420 421 421 ... ... @@ -611,8 +611,10 @@ 611 611 612 612 In a normal working state: 613 613 614 -* For each uplink, the (% style="color:red" %)**RED LED**(%%) will blink once. 615 -* For each success downlink, the (% style="color:purple" %)**PURPLE LED**(%%) will blink once. 603 +* For each uplink, the (% style="color:blue" %)**BLUE LED**(%%) or (% style="color:red" %)**RED LED**(%%) will blink once. 604 +(% style="color:blue" %)**BLUE LED**(%%) when external sensor is connected. 605 +* (% style="color:red" %)**RED LED**(%%) when external sensor is not connected 606 +* For each success downlink, the (% style="color:purple" %)**PURPLE LED**(%%) will blink once 616 616 617 617 == 2.9 installation == 618 618 ... ... @@ -682,7 +682,7 @@ 682 682 [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]] 683 683 684 684 685 -== (% data-sider-select-id="b105c0ce-c4b4-457e-b159-018a39209e92" %)4.3 Commands special design for LHT65N-PIR(%%)==676 +== 4.3 Commands special design for LHT65N-PIR == 686 686 687 687 688 688 These commands only valid for LHT65N-PIR, as below: ... ... @@ -695,8 +695,8 @@ 695 695 696 696 (% style="color:#4f81bd" %)**AT Command: ** 697 697 698 -(% border="1" cellspacing=" 3" style="background-color:#f2f2f2; width:501px" %)699 -|(% style="background-color:# 4f81bd; color:white; width:155px" %)**Command Example**|(% style="background-color:#4f81bd; color:white; width:166px" %)**Function**|(% style="background-color:#4f81bd; color:white; width:180px" %)**Response**689 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:501px" %) 690 +|(% style="background-color:#d9e2f3; color:#0070c0; width:155px" %)**Command Example**|(% style="background-color:#d9e2f3; color:#0070c0; width:166px" %)**Function**|(% style="background-color:#d9e2f3; color:#0070c0; width:180px" %)**Response** 700 700 |(% style="width:155px" %)AT+TDC=?|(% style="width:162px" %)Show current transmit Interval|(% style="width:177px" %)30000 OK the interval is 30000ms = 30s 701 701 |(% style="width:155px" %)AT+TDC=60000|(% style="width:162px" %)Set Transmit Interval|(% style="width:177px" %)OK Set transmit interval to 60000ms = 60 seconds 702 702 ... ... @@ -727,8 +727,8 @@ 727 727 728 728 (% style="color:#4f81bd" %)**AT Command: ** 729 729 730 -(% border="1" cellspacing=" 3" style="background-color:#f2f2f2; width:372px" %)731 -|(% style="background-color:# 4f81bd; color:white; width:155px" %)**Command Example**|(% style="background-color:#4f81bd; color:white; width:128px" %)**Function**|(% style="background-color:#4f81bd; color:white; width:89px" %)**Response**721 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:372px" %) 722 +|(% style="background-color:#d9e2f3; color:#0070c0; width:155px" %)**Command Example**|(% style="background-color:#d9e2f3; color:#0070c0; width:128px" %)**Function**|(% style="background-color:#d9e2f3; color:#0070c0; width:89px" %)**Response** 732 732 |(% style="width:155px" %)AT+PWORD=?|(% style="width:124px" %)Show password|(% style="width:86px" %)((( 733 733 123456 734 734 ... ... @@ -752,8 +752,8 @@ 752 752 753 753 (% style="color:#4f81bd" %)**AT Command: ** 754 754 755 -(% border="1" cellspacing=" 3" style="background-color:#f2f2f2; width:513px" %)756 -|(% style="background-color:# 4f81bd; color:white; width:155px" %)**Command Example**|(% style="background-color:#4f81bd; color:white; width:140px" %)**Function**|(% style="background-color:#4f81bd; color:white; width:218px" %)**Response**746 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:513px" %) 747 +|(% style="background-color:#d9e2f3; color:#0070c0; width:155px" %)**Command Example**|(% style="background-color:#d9e2f3; color:#0070c0; width:140px" %)**Function**|(% style="background-color:#d9e2f3; color:#0070c0; width:218px" %)**Response** 757 757 |(% style="width:155px" %)AT+SLEEP|(% style="width:139px" %)Set to sleep mode|(% style="width:213px" %)((( 758 758 Clear all stored sensor data… 759 759 ... ... @@ -767,10 +767,8 @@ 767 767 === 4.3.5 Set UOA (Uplink on Activity) === 768 768 769 769 770 -Feature: Enable / Disable Uplink on Activity .761 +Feature: Enable / Disable Uplink on Activity 771 771 772 -After the UOA is enabled, the LHT65N-PIR sends an uplink when the count is triggered. 773 - 774 774 (% style="color:#4f81bd" %)**AT Command: ** 775 775 776 776 * (% style="color:#037691" %)**AT+UOA=0**(%%) : Disable UoA ... ... @@ -786,31 +786,9 @@ 786 786 787 787 When followed by 3 bytes, the first byte is 01, and the second and third bytes are Calm Down Time. 788 788 789 -* (% style="color:#037691" %)**A1 00 **(%%)** ==> **AT+UOA=0****790 -* (% style="color:#037691" %)**A1 01 00 02 **(%%)** ==> **AT+UOA=1,2778 +* (% style="color:#037691" %)**A1 00 **(%%)** ==> AT+UOA=0 ** 779 +* (% style="color:#037691" %)**A1 01 00 02 **(%%)** ==> AT+UOA=1,2** 791 791 792 -=== (% data-sider-select-id="50a6265d-b76f-4699-846b-b82bee3a7ab0" %)4.3.6 Get data(%%) === 793 - 794 - 795 -Feature: Get the current sensor data 796 - 797 -(% style="color:#4f81bd" %)**AT Command:** 798 - 799 -* **AT+GETSENSORVALUE=0** ~/~/ The serial port gets the reading of the current sensor 800 -* **AT+GETSENSORVALUE=1** ~/~/ The serial port gets the current sensor reading and uploads it. 801 - 802 -=== (% data-sider-select-id="14f87315-b24f-4278-9b6c-0a8c2f35ad00" %)4.3.7 Set count number(%%) === 803 - 804 - 805 -Feature: Manually set the count number 806 - 807 -(% style="color:#4f81bd" %)**AT Command: AT+SETCNT** 808 - 809 -(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:481px" %) 810 -|=(% style="width: 162px;background-color:#4F81BD;color:white" %)**Command Example**|=(% style="width: 224px;background-color:#4F81BD;color:white" %)**Function**|=(% style="width: 95px;background-color:#4F81BD;color:white" %)**Response** 811 -|(% style="width:162px" %)AT+SETCNT=0|(% style="width:222px" %)Set the count number to 0.|(% style="width:93px" %)OK 812 -|(% style="width:162px" %)AT+SETCNT=100|(% style="width:222px" %)Set the count number to 100.|(% style="width:93px" %)OK 813 - 814 814 = 5. Battery & Power Consumption = 815 815 816 816 ... ... @@ -828,7 +828,7 @@ 828 828 * Update with new features. 829 829 * Fix bugs. 830 830 831 -Firmware and changelog can be downloaded from : **[[Firmware download link>>http s://www.dropbox.com/scl/fo/ztlw35a9xbkomu71u31im/AAAJrw0bI6-cH8sPI8uQL2U/LoRaWAN%20End%20Node/LHT65N-PIR?rlkey=ojjcsw927eaow01dgooldq3nu&subfolder_nav_tracking=1&dl=0]]**798 +Firmware and changelog can be downloaded from : **[[Firmware download link>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/]]** 832 832 833 833 Methods to Update Firmware: 834 834 ... ... @@ -839,8 +839,16 @@ 839 839 840 840 == 7.1 How to use AT Command? == 841 841 842 -Refer this link for [[UART Hardware Connection>>url:http://wiki.dragino.com/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/#H6.1HowtoconnecttoLHT65NUARTinterface3F]]. 843 843 810 +LHT65N-PIR supports AT Command set.User can use a USB to TTL adapter plus the Program Cable to connect to LHT65 for using AT command, as below. 811 + 812 + 813 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615153355-1.png||_mstalt="430222"]] 814 + 815 + 816 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@1655802313617-381.png||_mstalt="293917"]] 817 + 818 + 844 844 In PC, User needs to set serial tool(such as [[**putty**>>https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to (% style="color:green" %)**9600** (%%)to access to access serial console for LHT65N-PIR. The AT commands are disable by default and need to enter password (default:(% style="color:green" %)**123456**(% style="color:red" %))(%%) to active it. Timeout to input AT Command is 5 min, after 5-minute, user need to input password again. User can use AT+DISAT command to disable AT command before timeout. 845 845 846 846 [[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615154519-3.png||_mstalt="431925" height="672" width="807"]] ... ... @@ -893,11 +893,47 @@ 893 893 [[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615154519-3.png||_mstalt="431925" height="672" width="807"]] 894 894 895 895 896 -== 7.4 How to upgrade firmware? == 871 +== 7.4 How to use TTL-USB to connect PC to upgrade firmware? == 897 897 898 -Please check [[update instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/#H6.5Howtoupgradefirmware3F]]. 899 899 874 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615153355-1.png||_mstalt="430222"]] 900 900 876 + 877 +(% style="color:blue" %)**Step1**(%%): Install TremoProgrammer first. 878 + 879 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615170542-5.png||_mstalt="430638"]] 880 + 881 + 882 +(% _mstmutation="1" style="color:blue" %)**Step2**(%%):wiring method.(% style="display:none" %) 883 + 884 +First connect the four lines;(% style="display:none" %) 885 + 886 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220621170938-1.png||_mstalt="431340" height="413" width="419"]],(% style="display:none" %) 887 + 888 + 889 +Then use DuPont cable to short circuit port3 and port1, and then release them, so that the device enters bootlaod mode. 890 + 891 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220621170938-2.png||_mstalt="431704"]] 892 + 893 + 894 +(% style="color:blue" %)**Step3:**(%%)Select the device port to be connected, baud rate and bin file to be downloaded. 895 + 896 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615171334-6.png||_mstalt="431028"]] 897 + 898 + 899 +Click the (% style="color:blue" %)**start**(%%) button to start the firmware upgrade. 900 + 901 + 902 +When this interface appears, it indicates that the download has been completed. 903 + 904 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220620160723-8.png||_mstalt="430703"]] 905 + 906 + 907 +Finally, unplug the DuPont cable on port4, and then use the DuPont cable to short circuit port3 and port1 to reset the device. 908 + 909 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615154519-3.png||_mstalt="431925" height="672" width="807"]] 910 + 911 + 901 901 = 8. Order Info = 902 902 903 903
- 1749461666511-624.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -1.4 KB - Content
- 1749461668318-290.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -1.4 KB - Content
- 1749461670222-301.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -1.4 KB - Content
- 1749461678661-687.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -1.4 KB - Content
- 1749461680536-405.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -1.4 KB - Content
- image-20250424095841-1.jpeg
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -40.5 KB - Content