Last modified by Xiaoling on 2025/06/10 09:17

From version 54.2
edited by Xiaoling
on 2025/04/24 09:46
Change comment: There is no comment for this version
To version 52.2
edited by Xiaoling
on 2024/04/20 10:11
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -136,44 +136,32 @@
136 136  
137 137  User can enter these keys in the LoRaWAN Server portal. Below is TTN V3 screenshot:
138 138  
139 -**~1. Create application**
139 +Add APP EUI in the application.
140 140  
141 -[[image:https://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/WebHome/image-20250424091200-1.jpeg?rev=1.1||alt="image-20250424091200-1.jpeg"]]
142 142  
143 -[[image:https://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/WebHome/image-20250424091207-2.jpeg?rev=1.1||alt="image-20250424091207-2.jpeg"]]
142 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220522232916-3.png||_mstalt="430495"]]
144 144  
145 145  
146 -**2. Add devices to the created Application.**
145 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N-E5%20LoRaWAN%20Temperature_Humidity%20%26%20Illuminance%20Sensor%20User%20Manual/WebHome/image-20220522232932-4.png?rev=1.1||alt="image-20220522232932-4.png"]]
147 147  
148 -[[image:https://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/WebHome/image-20250424091404-3.jpeg?rev=1.1||alt="image-20250424091404-3.jpeg"]]
149 149  
150 -[[image:https://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/WebHome/image-20250424091412-4.jpeg?rev=1.1||alt="image-20250424091412-4.jpeg"]]
148 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N-E5%20LoRaWAN%20Temperature_Humidity%20%26%20Illuminance%20Sensor%20User%20Manual/WebHome/image-20220522232954-5.png?rev=1.1||alt="image-20220522232954-5.png"]]
151 151  
152 152  
153 -**3. Enter end device specifics manually.**
151 +(% style="color:red" %)**Note: LHT65N-PIR use same payload decoder as LHT65.**
154 154  
155 -[[image:https://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/WebHome/image-20250424091458-5.jpeg?rev=1.1||alt="image-20250424091458-5.jpeg"]]
156 156  
157 -[[image:https://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/WebHome/image-20250424091509-6.jpeg?rev=1.1||alt="image-20250424091509-6.jpeg"]]
154 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N-E5%20LoRaWAN%20Temperature_Humidity%20%26%20Illuminance%20Sensor%20User%20Manual/WebHome/image-20220522233026-6.png?rev=1.1||alt="image-20220522233026-6.png"]]
158 158  
159 159  
160 -=== 2.3.2 Step 2: Add decoder ===
157 +**Input APP EUI,  APP KEY and DEV EUI:**
161 161  
159 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N-E5%20LoRaWAN%20Temperature_Humidity%20%26%20Illuminance%20Sensor%20User%20Manual/WebHome/image-20220522233118-7.png?rev=1.1||alt="image-20220522233118-7.png"]]
162 162  
163 -In TTN, user can add a custom payload so it shows friendly reading.
164 164  
165 -Click this link to get the decoder: [[https:~~/~~/github.com/dragino/dragino-end-node-decoder/tree/main/>>url:https://github.com/dragino/dragino-end-node-decoder/tree/main/]]
162 +=== 2.3.2 Step 2: Activate LHT65N-PIR by pressing the ACT button for more than 5 seconds. ===
166 166  
167 -Below is TTN screen shot
168 168  
169 -[[image:https://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LWL04--LoRaWAN_Water_Leak_Sensor_User_Manual/WebHome/image-20240909162501-5.png?width=1084&height=516&rev=1.1||alt="image-20240909162501-5.png"]]
170 -
171 -[[image:https://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LWL04--LoRaWAN_Water_Leak_Sensor_User_Manual/WebHome/image-20240909162647-6.png?width=1086&height=494&rev=1.1||alt="image-20240909162647-6.png"]]
172 -
173 -
174 -=== 2.3.3 Step 3: Activate LHT65N-PIR by pressing the ACT button for more than 5 seconds. ===
175 -
176 -
177 177  Use ACT button to activate LHT65N-PIR and it will auto-join to the TTN V3 network. After join success, it will start to upload sensor data to TTN V3 and user can see in the panel.
178 178  
179 179  
... ... @@ -771,10 +771,8 @@
771 771  === 4.3.5 Set UOA (Uplink on Activity) ===
772 772  
773 773  
774 -Feature: Enable / Disable Uplink on Activity.
762 +Feature: Enable / Disable Uplink on Activity
775 775  
776 -After the UOA is enabled, the LHT65N-PIR sends an uplink when the count is triggered.
777 -
778 778  (% style="color:#4f81bd" %)**AT Command: **
779 779  
780 780  * (% style="color:#037691" %)**AT+UOA=0**(%%)  : Disable UoA
... ... @@ -803,6 +803,7 @@
803 803  * **AT+GETSENSORVALUE=0**      ~/~/ The serial port gets the reading of the current sensor
804 804  * **AT+GETSENSORVALUE=1**      ~/~/  The serial port gets the current sensor reading and uploads it.
805 805  
792 +
806 806  === (% data-sider-select-id="14f87315-b24f-4278-9b6c-0a8c2f35ad00" %)4.3.7 Set count number(%%) ===
807 807  
808 808  
... ... @@ -815,6 +815,7 @@
815 815  |(% style="width:162px" %)AT+SETCNT=0|(% style="width:222px" %)Set the count number to 0.|(% style="width:93px" %)OK
816 816  |(% style="width:162px" %)AT+SETCNT=100|(% style="width:222px" %)Set the count number to 100.|(% style="width:93px" %)OK
817 817  
805 +
818 818  = 5. Battery & Power Consumption =
819 819  
820 820  
... ... @@ -832,7 +832,7 @@
832 832  * Update with new features.
833 833  * Fix bugs.
834 834  
835 -Firmware and changelog can be downloaded from : **[[Firmware download link>>https://www.dropbox.com/scl/fo/ztlw35a9xbkomu71u31im/AAAJrw0bI6-cH8sPI8uQL2U/LoRaWAN%20End%20Node/LHT65N-PIR?rlkey=ojjcsw927eaow01dgooldq3nu&subfolder_nav_tracking=1&dl=0]]**
823 +Firmware and changelog can be downloaded from : **[[Firmware download link>>https://www.dropbox.com/sh/g99v0fxcltn9r1y/AAB_TCg_9QRfMlVYDReneEJCa/LHT65N?dl=0&subfolder_nav_tracking=1]]**
836 836  
837 837  Methods to Update Firmware:
838 838