Changes for page LHT65N-PIR Temperature/Humidity/PIR Motion Sensor User Manual
Last modified by Xiaoling on 2025/06/10 09:17
From version 53.1
edited by Mengting Qiu
on 2024/10/17 09:31
on 2024/10/17 09:31
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. ting1 +XWiki.Xiaoling - Content
-
... ... @@ -674,7 +674,7 @@ 674 674 [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]] 675 675 676 676 677 -== (% data-sider-select-id="b105c0ce-c4b4-457e-b159-018a39209e92" %)4.3 Commands special design for LHT65N-PIR(%%)==677 +== 4.3 Commands special design for LHT65N-PIR == 678 678 679 679 680 680 These commands only valid for LHT65N-PIR, as below: ... ... @@ -759,10 +759,8 @@ 759 759 === 4.3.5 Set UOA (Uplink on Activity) === 760 760 761 761 762 -Feature: Enable / Disable Uplink on Activity .762 +Feature: Enable / Disable Uplink on Activity 763 763 764 -After the UOA is enabled, the LHT65N-PIR sends an uplink when the count is triggered. 765 - 766 766 (% style="color:#4f81bd" %)**AT Command: ** 767 767 768 768 * (% style="color:#037691" %)**AT+UOA=0**(%%) : Disable UoA ... ... @@ -781,7 +781,7 @@ 781 781 * (% style="color:#037691" %)**A1 00 **(%%)** ==> **AT+UOA=0** ** 782 782 * (% style="color:#037691" %)**A1 01 00 02 **(%%)** ==> **AT+UOA=1,2 783 783 784 -=== (% data-sider-select-id="50a6265d-b76f-4699-846b-b82bee3a7ab0" %)4.3.6 Get data(%%)===782 +=== 4.3.6 Get data === 785 785 786 786 787 787 Feature: Get the current sensor data ... ... @@ -791,18 +791,6 @@ 791 791 * **AT+GETSENSORVALUE=0** ~/~/ The serial port gets the reading of the current sensor 792 792 * **AT+GETSENSORVALUE=1** ~/~/ The serial port gets the current sensor reading and uploads it. 793 793 794 -=== (% data-sider-select-id="14f87315-b24f-4278-9b6c-0a8c2f35ad00" %)4.3.7 Set count number(%%) === 795 - 796 - 797 -Feature: Manually set the count number 798 - 799 -(% style="color:#4f81bd" %)**AT Command: AT+SETCNT** 800 - 801 -(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:481px" %) 802 -|=(% style="width: 162px;background-color:#4F81BD;color:white" %)**Command Example**|=(% style="width: 224px;background-color:#4F81BD;color:white" %)**Function**|=(% style="width: 95px;background-color:#4F81BD;color:white" %)**Response** 803 -|(% style="width:162px" %)AT+SETCNT=0|(% style="width:222px" %)Set the count number to 0.|(% style="width:93px" %)OK 804 -|(% style="width:162px" %)AT+SETCNT=100|(% style="width:222px" %)Set the count number to 100.|(% style="width:93px" %)OK 805 - 806 806 = 5. Battery & Power Consumption = 807 807 808 808