Changes for page LHT65N-PIR Temperature/Humidity/PIR Motion Sensor User Manual
Last modified by Xiaoling on 2025/06/10 09:17
From version 52.1
edited by Bei Jinggeng
on 2024/04/16 13:42
on 2024/04/16 13:42
Change comment:
There is no comment for this version
To version 51.1
edited by Mengting Qiu
on 2024/03/28 10:23
on 2024/03/28 10:23
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Bei1 +XWiki.ting - Content
-
... ... @@ -61,7 +61,7 @@ 61 61 62 62 * Resolution: 0.04 %RH 63 63 * Accuracy Tolerance : Typ ±3 %RH 64 -* Long Term Drift: < 0.2 5RH/yr64 +* Long Term Drift: < 0.02 °C/yr 65 65 * Operating Range: 0 ~~ 96 %RH 66 66 67 67 (% style="color:#037691" %)**External PIR Sensor:** ... ... @@ -674,7 +674,7 @@ 674 674 [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]] 675 675 676 676 677 -== (% data-sider-select-id="b105c0ce-c4b4-457e-b159-018a39209e92" %)4.3 Commands special design for LHT65N-PIR(%%)==677 +== 4.3 Commands special design for LHT65N-PIR == 678 678 679 679 680 680 These commands only valid for LHT65N-PIR, as below: ... ... @@ -779,7 +779,7 @@ 779 779 * (% style="color:#037691" %)**A1 00 **(%%)** ==> **AT+UOA=0** ** 780 780 * (% style="color:#037691" %)**A1 01 00 02 **(%%)** ==> **AT+UOA=1,2 781 781 782 -=== (% data-sider-select-id="50a6265d-b76f-4699-846b-b82bee3a7ab0" %)4.3.6 Get data(%%)===782 +=== 4.3.6 Get data === 783 783 784 784 785 785 Feature: Get the current sensor data ... ... @@ -789,24 +789,6 @@ 789 789 * **AT+GETSENSORVALUE=0** ~/~/ The serial port gets the reading of the current sensor 790 790 * **AT+GETSENSORVALUE=1** ~/~/ The serial port gets the current sensor reading and uploads it. 791 791 792 -(% class="wikigeneratedid" %) 793 -=== === 794 - 795 -=== (% data-sider-select-id="14f87315-b24f-4278-9b6c-0a8c2f35ad00" %)4.3.7 Set count number(%%) === 796 - 797 - 798 -Feature: Manually set the count number 799 - 800 - 801 -(% style="color:#4f81bd" %)**AT Command: AT+SETCNT** 802 - 803 -(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:481px" %) 804 -|=(% style="width: 162px;background-color:#4F81BD;color:white" %)**Command Example**|=(% style="width: 224px;background-color:#4F81BD;color:white" %)**Function**|=(% style="width: 95px;background-color:#4F81BD;color:white" %)**Response** 805 -|(% style="width:162px" %)AT+SETCNT=0|(% style="width:222px" %)Set the count number to 0.|(% style="width:93px" %)OK 806 -|(% style="width:162px" %)AT+SETCNT=100|(% style="width:222px" %)Set the count number to 100.|(% style="width:93px" %)OK 807 - 808 - 809 - 810 810 = 5. Battery & Power Consumption = 811 811 812 812