Changes for page LHT65N-PIR Temperature/Humidity/PIR Motion Sensor User Manual
Last modified by Xiaoling on 2025/06/10 09:17
From version 51.1
edited by Mengting Qiu
on 2024/03/28 10:23
on 2024/03/28 10:23
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. ting1 +XWiki.Xiaoling - Content
-
... ... @@ -61,7 +61,7 @@ 61 61 62 62 * Resolution: 0.04 %RH 63 63 * Accuracy Tolerance : Typ ±3 %RH 64 -* Long Term Drift: < 0. 02°C/yr64 +* Long Term Drift: < 0.25 RH/yr 65 65 * Operating Range: 0 ~~ 96 %RH 66 66 67 67 (% style="color:#037691" %)**External PIR Sensor:** ... ... @@ -136,32 +136,44 @@ 136 136 137 137 User can enter these keys in the LoRaWAN Server portal. Below is TTN V3 screenshot: 138 138 139 - AddAPP EUI inthe application.139 +**~1. Create application** 140 140 141 +[[image:https://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/WebHome/image-20250424091200-1.jpeg?rev=1.1||alt="image-20250424091200-1.jpeg"]] 141 141 142 -[[image: Main.User.LHT65N-E5LoRaWAN_Humidity& IlluminanceSensorUserManual.WebHome@image-20220522232916-3.png||_mstalt="430495"]]143 +[[image:https://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/WebHome/image-20250424091207-2.jpeg?rev=1.1||alt="image-20250424091207-2.jpeg"]] 143 143 144 144 145 - [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N-E5%20LoRaWAN%20Temperature_Humidity%20%26%20Illuminance%20Sensor%20User%20Manual/WebHome/image-20220522232932-4.png?rev=1.1||alt="image-20220522232932-4.png"]]146 +**2. Add devices to the created Application.** 146 146 148 +[[image:https://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/WebHome/image-20250424091404-3.jpeg?rev=1.1||alt="image-20250424091404-3.jpeg"]] 147 147 148 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N -E5%20LoRaWAN%20Temperature_Humidity%20%26%20Illuminance%20Sensor%20User%20Manual/WebHome/image-20220522232954-5.png?rev=1.1||alt="image-20220522232954-5.png"]]150 +[[image:https://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/WebHome/image-20250424091412-4.jpeg?rev=1.1||alt="image-20250424091412-4.jpeg"]] 149 149 150 150 151 - (%style="color:red"%)**Note: LHT65N-PIR use samepayload decoder asLHT65.**153 +**3. Enter end device specifics manually.** 152 152 155 +[[image:https://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/WebHome/image-20250424091458-5.jpeg?rev=1.1||alt="image-20250424091458-5.jpeg"]] 153 153 154 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N -E5%20LoRaWAN%20Temperature_Humidity%20%26%20Illuminance%20Sensor%20User%20Manual/WebHome/image-20220522233026-6.png?rev=1.1||alt="image-20220522233026-6.png"]]157 +[[image:https://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/WebHome/image-20250424091509-6.jpeg?rev=1.1||alt="image-20250424091509-6.jpeg"]] 155 155 156 156 157 - **InputAPPEUI,APPKEY andDEV EUI:**160 +=== 2.3.2 Step 2: Add decoder === 158 158 159 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N-E5%20LoRaWAN%20Temperature_Humidity%20%26%20Illuminance%20Sensor%20User%20Manual/WebHome/image-20220522233118-7.png?rev=1.1||alt="image-20220522233118-7.png"]] 160 160 163 +In TTN, user can add a custom payload so it shows friendly reading. 161 161 162 - ===2.3.2Step2:Activate LHT65N-PIRby pressingheACT buttonformorethan5 seconds. ===165 +Click this link to get the decoder: [[https:~~/~~/github.com/dragino/dragino-end-node-decoder/tree/main/>>url:https://github.com/dragino/dragino-end-node-decoder/tree/main/]] 163 163 167 +Below is TTN screen shot 164 164 169 +[[image:https://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LWL04--LoRaWAN_Water_Leak_Sensor_User_Manual/WebHome/image-20240909162501-5.png?width=1084&height=516&rev=1.1||alt="image-20240909162501-5.png"]] 170 + 171 +[[image:https://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LWL04--LoRaWAN_Water_Leak_Sensor_User_Manual/WebHome/image-20240909162647-6.png?width=1086&height=494&rev=1.1||alt="image-20240909162647-6.png"]] 172 + 173 + 174 +=== 2.3.3 Step 3: Activate LHT65N-PIR by pressing the ACT button for more than 5 seconds. === 175 + 176 + 165 165 Use ACT button to activate LHT65N-PIR and it will auto-join to the TTN V3 network. After join success, it will start to upload sensor data to TTN V3 and user can see in the panel. 166 166 167 167 ... ... @@ -674,7 +674,7 @@ 674 674 [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]] 675 675 676 676 677 -== 4.3 Commands special design for LHT65N-PIR == 689 +== (% data-sider-select-id="b105c0ce-c4b4-457e-b159-018a39209e92" %)4.3 Commands special design for LHT65N-PIR(%%) == 678 678 679 679 680 680 These commands only valid for LHT65N-PIR, as below: ... ... @@ -759,8 +759,10 @@ 759 759 === 4.3.5 Set UOA (Uplink on Activity) === 760 760 761 761 762 -Feature: Enable / Disable Uplink on Activity 774 +Feature: Enable / Disable Uplink on Activity. 763 763 776 +After the UOA is enabled, the LHT65N-PIR sends an uplink when the count is triggered. 777 + 764 764 (% style="color:#4f81bd" %)**AT Command: ** 765 765 766 766 * (% style="color:#037691" %)**AT+UOA=0**(%%) : Disable UoA ... ... @@ -779,7 +779,7 @@ 779 779 * (% style="color:#037691" %)**A1 00 **(%%)** ==> **AT+UOA=0** ** 780 780 * (% style="color:#037691" %)**A1 01 00 02 **(%%)** ==> **AT+UOA=1,2 781 781 782 -=== 4.3.6 Get data === 796 +=== (% data-sider-select-id="50a6265d-b76f-4699-846b-b82bee3a7ab0" %)4.3.6 Get data(%%) === 783 783 784 784 785 785 Feature: Get the current sensor data ... ... @@ -789,6 +789,18 @@ 789 789 * **AT+GETSENSORVALUE=0** ~/~/ The serial port gets the reading of the current sensor 790 790 * **AT+GETSENSORVALUE=1** ~/~/ The serial port gets the current sensor reading and uploads it. 791 791 806 +=== (% data-sider-select-id="14f87315-b24f-4278-9b6c-0a8c2f35ad00" %)4.3.7 Set count number(%%) === 807 + 808 + 809 +Feature: Manually set the count number 810 + 811 +(% style="color:#4f81bd" %)**AT Command: AT+SETCNT** 812 + 813 +(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:481px" %) 814 +|=(% style="width: 162px;background-color:#4F81BD;color:white" %)**Command Example**|=(% style="width: 224px;background-color:#4F81BD;color:white" %)**Function**|=(% style="width: 95px;background-color:#4F81BD;color:white" %)**Response** 815 +|(% style="width:162px" %)AT+SETCNT=0|(% style="width:222px" %)Set the count number to 0.|(% style="width:93px" %)OK 816 +|(% style="width:162px" %)AT+SETCNT=100|(% style="width:222px" %)Set the count number to 100.|(% style="width:93px" %)OK 817 + 792 792 = 5. Battery & Power Consumption = 793 793 794 794 ... ... @@ -806,7 +806,7 @@ 806 806 * Update with new features. 807 807 * Fix bugs. 808 808 809 -Firmware and changelog can be downloaded from : **[[Firmware download link>>https://www.dropbox.com/s h/g99v0fxcltn9r1y/AAB_TCg_9QRfMlVYDReneEJCa/LHT65N?dl=0&subfolder_nav_tracking=1]]**835 +Firmware and changelog can be downloaded from : **[[Firmware download link>>https://www.dropbox.com/scl/fo/ztlw35a9xbkomu71u31im/AAAJrw0bI6-cH8sPI8uQL2U/LoRaWAN%20End%20Node/LHT65N-PIR?rlkey=ojjcsw927eaow01dgooldq3nu&subfolder_nav_tracking=1&dl=0]]** 810 810 811 811 Methods to Update Firmware: 812 812