Last modified by Xiaoling on 2025/06/10 09:17

From version 50.1
edited by Edwin Chen
on 2024/01/28 20:01
Change comment: There is no comment for this version
To version 54.2
edited by Xiaoling
on 2025/04/24 09:46
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Edwin
1 +XWiki.Xiaoling
Content
... ... @@ -61,7 +61,7 @@
61 61  
62 62  * Resolution: 0.04 %RH
63 63  * Accuracy Tolerance : Typ ±3 %RH
64 -* Long Term Drift: < 0.02 °C/yr
64 +* Long Term Drift: < 0.25 RH/yr
65 65  * Operating Range: 0 ~~ 96 %RH
66 66  
67 67  (% style="color:#037691" %)**External PIR Sensor:**
... ... @@ -136,32 +136,44 @@
136 136  
137 137  User can enter these keys in the LoRaWAN Server portal. Below is TTN V3 screenshot:
138 138  
139 -Add APP EUI in the application.
139 +**~1. Create application**
140 140  
141 +[[image:https://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/WebHome/image-20250424091200-1.jpeg?rev=1.1||alt="image-20250424091200-1.jpeg"]]
141 141  
142 -[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220522232916-3.png||_mstalt="430495"]]
143 +[[image:https://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/WebHome/image-20250424091207-2.jpeg?rev=1.1||alt="image-20250424091207-2.jpeg"]]
143 143  
144 144  
145 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N-E5%20LoRaWAN%20Temperature_Humidity%20%26%20Illuminance%20Sensor%20User%20Manual/WebHome/image-20220522232932-4.png?rev=1.1||alt="image-20220522232932-4.png"]]
146 +**2. Add devices to the created Application.**
146 146  
148 +[[image:https://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/WebHome/image-20250424091404-3.jpeg?rev=1.1||alt="image-20250424091404-3.jpeg"]]
147 147  
148 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N-E5%20LoRaWAN%20Temperature_Humidity%20%26%20Illuminance%20Sensor%20User%20Manual/WebHome/image-20220522232954-5.png?rev=1.1||alt="image-20220522232954-5.png"]]
150 +[[image:https://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/WebHome/image-20250424091412-4.jpeg?rev=1.1||alt="image-20250424091412-4.jpeg"]]
149 149  
150 150  
151 -(% style="color:red" %)**Note: LHT65N-PIR use same payload decoder as LHT65.**
153 +**3. Enter end device specifics manually.**
152 152  
155 +[[image:https://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/WebHome/image-20250424091458-5.jpeg?rev=1.1||alt="image-20250424091458-5.jpeg"]]
153 153  
154 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N-E5%20LoRaWAN%20Temperature_Humidity%20%26%20Illuminance%20Sensor%20User%20Manual/WebHome/image-20220522233026-6.png?rev=1.1||alt="image-20220522233026-6.png"]]
157 +[[image:https://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/WebHome/image-20250424091509-6.jpeg?rev=1.1||alt="image-20250424091509-6.jpeg"]]
155 155  
156 156  
157 -**Input APP EUI,  APP KEY and DEV EUI:**
160 +=== 2.3.2 Step 2: Add decoder ===
158 158  
159 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N-E5%20LoRaWAN%20Temperature_Humidity%20%26%20Illuminance%20Sensor%20User%20Manual/WebHome/image-20220522233118-7.png?rev=1.1||alt="image-20220522233118-7.png"]]
160 160  
163 +In TTN, user can add a custom payload so it shows friendly reading.
161 161  
162 -=== 2.3.2 Step 2: Activate LHT65N-PIR by pressing the ACT button for more than 5 seconds. ===
165 +Click this link to get the decoder: [[https:~~/~~/github.com/dragino/dragino-end-node-decoder/tree/main/>>url:https://github.com/dragino/dragino-end-node-decoder/tree/main/]]
163 163  
167 +Below is TTN screen shot
164 164  
169 +[[image:https://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LWL04--LoRaWAN_Water_Leak_Sensor_User_Manual/WebHome/image-20240909162501-5.png?width=1084&height=516&rev=1.1||alt="image-20240909162501-5.png"]]
170 +
171 +[[image:https://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LWL04--LoRaWAN_Water_Leak_Sensor_User_Manual/WebHome/image-20240909162647-6.png?width=1086&height=494&rev=1.1||alt="image-20240909162647-6.png"]]
172 +
173 +
174 +=== 2.3.3 Step 3: Activate LHT65N-PIR by pressing the ACT button for more than 5 seconds. ===
175 +
176 +
165 165  Use ACT button to activate LHT65N-PIR and it will auto-join to the TTN V3 network. After join success, it will start to upload sensor data to TTN V3 and user can see in the panel.
166 166  
167 167  
... ... @@ -603,10 +603,8 @@
603 603  
604 604  In a normal working state:
605 605  
606 -* For each uplink, the (% style="color:blue" %)**BLUE LED**(%%) or (% style="color:red" %)**RED LED**(%%) will blink once.
607 -(% style="color:blue" %)**BLUE LED**(%%) when external sensor is connected.
608 -* (% style="color:red" %)**RED LED**(%%) when external sensor is not connected
609 -* For each success downlink, the (% style="color:purple" %)**PURPLE LED**(%%) will blink once
618 +* For each uplink, the (% style="color:red" %)**RED LED**(%%) will blink once.
619 +* For each success downlink, the (% style="color:purple" %)**PURPLE LED**(%%) will blink once.
610 610  
611 611  == 2.9 installation ==
612 612  
... ... @@ -676,7 +676,7 @@
676 676  [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]]
677 677  
678 678  
679 -== 4.3 Commands special design for LHT65N-PIR ==
689 +== (% data-sider-select-id="b105c0ce-c4b4-457e-b159-018a39209e92" %)4.3 Commands special design for LHT65N-PIR(%%) ==
680 680  
681 681  
682 682  These commands only valid for LHT65N-PIR, as below:
... ... @@ -761,8 +761,10 @@
761 761  === 4.3.5 Set UOA (Uplink on Activity) ===
762 762  
763 763  
764 -Feature: Enable / Disable Uplink on Activity
774 +Feature: Enable / Disable Uplink on Activity.
765 765  
776 +After the UOA is enabled, the LHT65N-PIR sends an uplink when the count is triggered.
777 +
766 766  (% style="color:#4f81bd" %)**AT Command: **
767 767  
768 768  * (% style="color:#037691" %)**AT+UOA=0**(%%)  : Disable UoA
... ... @@ -781,7 +781,7 @@
781 781  * (% style="color:#037691" %)**A1 00    **(%%)** ==>    **AT+UOA=0**     **
782 782  * (% style="color:#037691" %)**A1 01 00 02  **(%%)** ==>    **AT+UOA=1,2
783 783  
784 -=== 4.3.6 Get data ===
796 +=== (% data-sider-select-id="50a6265d-b76f-4699-846b-b82bee3a7ab0" %)4.3.6 Get data(%%) ===
785 785  
786 786  
787 787  Feature: Get the current sensor data
... ... @@ -791,6 +791,18 @@
791 791  * **AT+GETSENSORVALUE=0**      ~/~/ The serial port gets the reading of the current sensor
792 792  * **AT+GETSENSORVALUE=1**      ~/~/  The serial port gets the current sensor reading and uploads it.
793 793  
806 +=== (% data-sider-select-id="14f87315-b24f-4278-9b6c-0a8c2f35ad00" %)4.3.7 Set count number(%%) ===
807 +
808 +
809 +Feature: Manually set the count number
810 +
811 +(% style="color:#4f81bd" %)**AT Command: AT+SETCNT**
812 +
813 +(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:481px" %)
814 +|=(% style="width: 162px;background-color:#4F81BD;color:white" %)**Command Example**|=(% style="width: 224px;background-color:#4F81BD;color:white" %)**Function**|=(% style="width: 95px;background-color:#4F81BD;color:white" %)**Response**
815 +|(% style="width:162px" %)AT+SETCNT=0|(% style="width:222px" %)Set the count number to 0.|(% style="width:93px" %)OK
816 +|(% style="width:162px" %)AT+SETCNT=100|(% style="width:222px" %)Set the count number to 100.|(% style="width:93px" %)OK
817 +
794 794  = 5. Battery & Power Consumption =
795 795  
796 796  
... ... @@ -808,7 +808,7 @@
808 808  * Update with new features.
809 809  * Fix bugs.
810 810  
811 -Firmware and changelog can be downloaded from : **[[Firmware download link>>https://www.dropbox.com/sh/g99v0fxcltn9r1y/AAB_TCg_9QRfMlVYDReneEJCa/LHT65N?dl=0&subfolder_nav_tracking=1]]**
835 +Firmware and changelog can be downloaded from : **[[Firmware download link>>https://www.dropbox.com/scl/fo/ztlw35a9xbkomu71u31im/AAAJrw0bI6-cH8sPI8uQL2U/LoRaWAN%20End%20Node/LHT65N-PIR?rlkey=ojjcsw927eaow01dgooldq3nu&subfolder_nav_tracking=1&dl=0]]**
812 812  
813 813  Methods to Update Firmware:
814 814