Last modified by Xiaoling on 2025/06/10 09:17

From version 50.1
edited by Edwin Chen
on 2024/01/28 20:01
Change comment: There is no comment for this version
To version 52.1
edited by Bei Jinggeng
on 2024/04/16 13:42
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Edwin
1 +XWiki.Bei
Content
... ... @@ -61,7 +61,7 @@
61 61  
62 62  * Resolution: 0.04 %RH
63 63  * Accuracy Tolerance : Typ ±3 %RH
64 -* Long Term Drift: < 0.02 °C/yr
64 +* Long Term Drift: < 0.25 RH/yr
65 65  * Operating Range: 0 ~~ 96 %RH
66 66  
67 67  (% style="color:#037691" %)**External PIR Sensor:**
... ... @@ -603,10 +603,8 @@
603 603  
604 604  In a normal working state:
605 605  
606 -* For each uplink, the (% style="color:blue" %)**BLUE LED**(%%) or (% style="color:red" %)**RED LED**(%%) will blink once.
607 -(% style="color:blue" %)**BLUE LED**(%%) when external sensor is connected.
608 -* (% style="color:red" %)**RED LED**(%%) when external sensor is not connected
609 -* For each success downlink, the (% style="color:purple" %)**PURPLE LED**(%%) will blink once
606 +* For each uplink, the (% style="color:red" %)**RED LED**(%%) will blink once.
607 +* For each success downlink, the (% style="color:purple" %)**PURPLE LED**(%%) will blink once.
610 610  
611 611  == 2.9 installation ==
612 612  
... ... @@ -676,7 +676,7 @@
676 676  [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]]
677 677  
678 678  
679 -== 4.3 Commands special design for LHT65N-PIR ==
677 +== (% data-sider-select-id="b105c0ce-c4b4-457e-b159-018a39209e92" %)4.3 Commands special design for LHT65N-PIR(%%) ==
680 680  
681 681  
682 682  These commands only valid for LHT65N-PIR, as below:
... ... @@ -781,7 +781,7 @@
781 781  * (% style="color:#037691" %)**A1 00    **(%%)** ==>    **AT+UOA=0**     **
782 782  * (% style="color:#037691" %)**A1 01 00 02  **(%%)** ==>    **AT+UOA=1,2
783 783  
784 -=== 4.3.6 Get data ===
782 +=== (% data-sider-select-id="50a6265d-b76f-4699-846b-b82bee3a7ab0" %)4.3.6 Get data(%%) ===
785 785  
786 786  
787 787  Feature: Get the current sensor data
... ... @@ -791,6 +791,24 @@
791 791  * **AT+GETSENSORVALUE=0**      ~/~/ The serial port gets the reading of the current sensor
792 792  * **AT+GETSENSORVALUE=1**      ~/~/  The serial port gets the current sensor reading and uploads it.
793 793  
792 +(% class="wikigeneratedid" %)
793 +=== ===
794 +
795 +=== (% data-sider-select-id="14f87315-b24f-4278-9b6c-0a8c2f35ad00" %)4.3.7 Set count number(%%) ===
796 +
797 +
798 +Feature: Manually set the count number
799 +
800 +
801 +(% style="color:#4f81bd" %)**AT Command: AT+SETCNT**
802 +
803 +(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:481px" %)
804 +|=(% style="width: 162px;background-color:#4F81BD;color:white" %)**Command Example**|=(% style="width: 224px;background-color:#4F81BD;color:white" %)**Function**|=(% style="width: 95px;background-color:#4F81BD;color:white" %)**Response**
805 +|(% style="width:162px" %)AT+SETCNT=0|(% style="width:222px" %)Set the count number to 0.|(% style="width:93px" %)OK
806 +|(% style="width:162px" %)AT+SETCNT=100|(% style="width:222px" %)Set the count number to 100.|(% style="width:93px" %)OK
807 +
808 +
809 +
794 794  = 5. Battery & Power Consumption =
795 795  
796 796