Changes for page LHT65N-PIR Temperature/Humidity/PIR Motion Sensor User Manual
Last modified by Xiaoling on 2025/06/10 09:17
From version 49.1
edited by Mengting Qiu
on 2024/01/17 14:59
on 2024/01/17 14:59
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. ting1 +XWiki.Xiaoling - Content
-
... ... @@ -61,7 +61,7 @@ 61 61 62 62 * Resolution: 0.04 %RH 63 63 * Accuracy Tolerance : Typ ±3 %RH 64 -* Long Term Drift: < 0. 02°C/yr64 +* Long Term Drift: < 0.25 RH/yr 65 65 * Operating Range: 0 ~~ 96 %RH 66 66 67 67 (% style="color:#037691" %)**External PIR Sensor:** ... ... @@ -603,10 +603,8 @@ 603 603 604 604 In a normal working state: 605 605 606 -* For each uplink, the (% style="color:blue" %)**BLUE LED**(%%) or (% style="color:red" %)**RED LED**(%%) will blink once. 607 -(% style="color:blue" %)**BLUE LED**(%%) when external sensor is connected. 608 -* (% style="color:red" %)**RED LED**(%%) when external sensor is not connected 609 -* For each success downlink, the (% style="color:purple" %)**PURPLE LED**(%%) will blink once 606 +* For each uplink, the (% style="color:red" %)**RED LED**(%%) will blink once. 607 +* For each success downlink, the (% style="color:purple" %)**PURPLE LED**(%%) will blink once. 610 610 611 611 == 2.9 installation == 612 612 ... ... @@ -676,7 +676,7 @@ 676 676 [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]] 677 677 678 678 679 -== 4.3 Commands special design for LHT65N-PIR == 677 +== (% data-sider-select-id="b105c0ce-c4b4-457e-b159-018a39209e92" %)4.3 Commands special design for LHT65N-PIR(%%) == 680 680 681 681 682 682 These commands only valid for LHT65N-PIR, as below: ... ... @@ -781,7 +781,7 @@ 781 781 * (% style="color:#037691" %)**A1 00 **(%%)** ==> **AT+UOA=0** ** 782 782 * (% style="color:#037691" %)**A1 01 00 02 **(%%)** ==> **AT+UOA=1,2 783 783 784 -=== 4.3.6 Get data === 782 +=== (% data-sider-select-id="50a6265d-b76f-4699-846b-b82bee3a7ab0" %)4.3.6 Get data(%%) === 785 785 786 786 787 787 Feature: Get the current sensor data ... ... @@ -791,6 +791,20 @@ 791 791 * **AT+GETSENSORVALUE=0** ~/~/ The serial port gets the reading of the current sensor 792 792 * **AT+GETSENSORVALUE=1** ~/~/ The serial port gets the current sensor reading and uploads it. 793 793 792 + 793 +=== (% data-sider-select-id="14f87315-b24f-4278-9b6c-0a8c2f35ad00" %)4.3.7 Set count number(%%) === 794 + 795 + 796 +Feature: Manually set the count number 797 + 798 +(% style="color:#4f81bd" %)**AT Command: AT+SETCNT** 799 + 800 +(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:481px" %) 801 +|=(% style="width: 162px;background-color:#4F81BD;color:white" %)**Command Example**|=(% style="width: 224px;background-color:#4F81BD;color:white" %)**Function**|=(% style="width: 95px;background-color:#4F81BD;color:white" %)**Response** 802 +|(% style="width:162px" %)AT+SETCNT=0|(% style="width:222px" %)Set the count number to 0.|(% style="width:93px" %)OK 803 +|(% style="width:162px" %)AT+SETCNT=100|(% style="width:222px" %)Set the count number to 100.|(% style="width:93px" %)OK 804 + 805 + 794 794 = 5. Battery & Power Consumption = 795 795 796 796 ... ... @@ -819,16 +819,8 @@ 819 819 820 820 == 7.1 How to use AT Command? == 821 821 834 +Refer this link for [[UART Hardware Connection>>url:http://wiki.dragino.com/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/#H6.1HowtoconnecttoLHT65NUARTinterface3F]]. 822 822 823 -LHT65N-PIR supports AT Command set.User can use a USB to TTL adapter plus the Program Cable to connect to LHT65 for using AT command, as below. 824 - 825 - 826 -[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615153355-1.png||_mstalt="430222"]] 827 - 828 - 829 -[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@1655802313617-381.png||_mstalt="293917"]] 830 - 831 - 832 832 In PC, User needs to set serial tool(such as [[**putty**>>https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to (% style="color:green" %)**9600** (%%)to access to access serial console for LHT65N-PIR. The AT commands are disable by default and need to enter password (default:(% style="color:green" %)**123456**(% style="color:red" %))(%%) to active it. Timeout to input AT Command is 5 min, after 5-minute, user need to input password again. User can use AT+DISAT command to disable AT command before timeout. 833 833 834 834 [[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615154519-3.png||_mstalt="431925" height="672" width="807"]] ... ... @@ -881,47 +881,11 @@ 881 881 [[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615154519-3.png||_mstalt="431925" height="672" width="807"]] 882 882 883 883 884 -== 7.4 How to u se TTL-USB to connect PC to upgrade firmware? ==888 +== 7.4 How to upgrade firmware? == 885 885 890 +Please check [[update instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/#H6.5Howtoupgradefirmware3F]]. 886 886 887 -[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615153355-1.png||_mstalt="430222"]] 888 888 889 - 890 -(% style="color:blue" %)**Step1**(%%): Install TremoProgrammer first. 891 - 892 -[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615170542-5.png||_mstalt="430638"]] 893 - 894 - 895 -(% _mstmutation="1" style="color:blue" %)**Step2**(%%):wiring method.(% style="display:none" %) 896 - 897 -First connect the four lines;(% style="display:none" %) 898 - 899 -[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220621170938-1.png||_mstalt="431340" height="413" width="419"]],(% style="display:none" %) 900 - 901 - 902 -Then use DuPont cable to short circuit port3 and port1, and then release them, so that the device enters bootlaod mode. 903 - 904 -[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220621170938-2.png||_mstalt="431704"]] 905 - 906 - 907 -(% style="color:blue" %)**Step3:**(%%)Select the device port to be connected, baud rate and bin file to be downloaded. 908 - 909 -[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615171334-6.png||_mstalt="431028"]] 910 - 911 - 912 -Click the (% style="color:blue" %)**start**(%%) button to start the firmware upgrade. 913 - 914 - 915 -When this interface appears, it indicates that the download has been completed. 916 - 917 -[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220620160723-8.png||_mstalt="430703"]] 918 - 919 - 920 -Finally, unplug the DuPont cable on port4, and then use the DuPont cable to short circuit port3 and port1 to reset the device. 921 - 922 -[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615154519-3.png||_mstalt="431925" height="672" width="807"]] 923 - 924 - 925 925 = 8. Order Info = 926 926 927 927 ... ... @@ -958,5 +958,3 @@ 958 958 (1) This device may not cause harmful interference; 959 959 960 960 (2) this device must accept any interference received, including interference that may cause undesired operation. 961 - 962 -