Changes for page LHT65N-PIR Temperature/Humidity/PIR Motion Sensor User Manual
Last modified by Xiaoling on 2025/06/10 09:17
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -61,7 +61,7 @@ 61 61 62 62 * Resolution: 0.04 %RH 63 63 * Accuracy Tolerance : Typ ±3 %RH 64 -* Long Term Drift: < 0. 02°C/yr64 +* Long Term Drift: < 0.25 RH/yr 65 65 * Operating Range: 0 ~~ 96 %RH 66 66 67 67 (% style="color:#037691" %)**External PIR Sensor:** ... ... @@ -136,32 +136,44 @@ 136 136 137 137 User can enter these keys in the LoRaWAN Server portal. Below is TTN V3 screenshot: 138 138 139 - AddAPP EUI inthe application.139 +**~1. Create application** 140 140 141 +[[image:https://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/WebHome/image-20250424091200-1.jpeg?rev=1.1||alt="image-20250424091200-1.jpeg"]] 141 141 142 -[[image: Main.User.LHT65N-E5LoRaWAN_Humidity& IlluminanceSensorUserManual.WebHome@image-20220522232916-3.png||_mstalt="430495"]]143 +[[image:https://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/WebHome/image-20250424091207-2.jpeg?rev=1.1||alt="image-20250424091207-2.jpeg"]] 143 143 144 144 145 - [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N-E5%20LoRaWAN%20Temperature_Humidity%20%26%20Illuminance%20Sensor%20User%20Manual/WebHome/image-20220522232932-4.png?rev=1.1||alt="image-20220522232932-4.png"]]146 +**2. Add devices to the created Application.** 146 146 148 +[[image:https://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/WebHome/image-20250424091404-3.jpeg?rev=1.1||alt="image-20250424091404-3.jpeg"]] 147 147 148 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N -E5%20LoRaWAN%20Temperature_Humidity%20%26%20Illuminance%20Sensor%20User%20Manual/WebHome/image-20220522232954-5.png?rev=1.1||alt="image-20220522232954-5.png"]]150 +[[image:https://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/WebHome/image-20250424091412-4.jpeg?rev=1.1||alt="image-20250424091412-4.jpeg"]] 149 149 150 150 151 - (%style="color:red"%)**Note: LHT65N-PIR use samepayload decoder asLHT65.**153 +**3. Enter end device specifics manually.** 152 152 155 +[[image:https://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/WebHome/image-20250424091458-5.jpeg?rev=1.1||alt="image-20250424091458-5.jpeg"]] 153 153 154 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N -E5%20LoRaWAN%20Temperature_Humidity%20%26%20Illuminance%20Sensor%20User%20Manual/WebHome/image-20220522233026-6.png?rev=1.1||alt="image-20220522233026-6.png"]]157 +[[image:https://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/WebHome/image-20250424091509-6.jpeg?rev=1.1||alt="image-20250424091509-6.jpeg"]] 155 155 156 156 157 - **InputAPPEUI,APPKEY andDEV EUI:**160 +=== 2.3.2 Step 2: Add decoder === 158 158 159 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N-E5%20LoRaWAN%20Temperature_Humidity%20%26%20Illuminance%20Sensor%20User%20Manual/WebHome/image-20220522233118-7.png?rev=1.1||alt="image-20220522233118-7.png"]] 160 160 163 +In TTN, user can add a custom payload so it shows friendly reading. 161 161 162 - ===2.3.2Step2:Activate LHT65N-PIRby pressingheACT buttonformorethan5 seconds. ===165 +Click this link to get the decoder: [[https:~~/~~/github.com/dragino/dragino-end-node-decoder/tree/main/>>url:https://github.com/dragino/dragino-end-node-decoder/tree/main/]] 163 163 167 +Below is TTN screen shot 164 164 169 +[[image:https://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LWL04--LoRaWAN_Water_Leak_Sensor_User_Manual/WebHome/image-20240909162501-5.png?width=1084&height=516&rev=1.1||alt="image-20240909162501-5.png"]] 170 + 171 +[[image:https://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LWL04--LoRaWAN_Water_Leak_Sensor_User_Manual/WebHome/image-20240909162647-6.png?width=1086&height=494&rev=1.1||alt="image-20240909162647-6.png"]] 172 + 173 + 174 +=== 2.3.3 Step 3: Activate LHT65N-PIR by pressing the ACT button for more than 5 seconds. === 175 + 176 + 165 165 Use ACT button to activate LHT65N-PIR and it will auto-join to the TTN V3 network. After join success, it will start to upload sensor data to TTN V3 and user can see in the panel. 166 166 167 167 ... ... @@ -176,7 +176,7 @@ 176 176 The Payload format is as below. 177 177 178 178 (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 179 -|(% colspan="6" style="background-color:#4 F81BD;color:white" %)**Device Status (FPORT=5)**191 +|(% colspan="6" style="background-color:#4f81bd; color:white" %)**Device Status (FPORT=5)** 180 180 |(% style="background-color:#f2f2f2; width:103px" %)**Size (bytes)**|(% style="background-color:#f2f2f2; width:72px" %)**1**|(% style="background-color:#f2f2f2" %)**2**|(% style="background-color:#f2f2f2; width:91px" %)**1**|(% style="background-color:#f2f2f2; width:86px" %)**1**|(% style="background-color:#f2f2f2; width:44px" %)**2** 181 181 |(% style="background-color:#f2f2f2; width:103px" %)Value|(% style="background-color:#f2f2f2; width:72px" %)Sensor Model|(% style="background-color:#f2f2f2" %)Firmware Version|(% style="background-color:#f2f2f2; width:91px" %)Frequency Band|(% style="background-color:#f2f2f2; width:86px" %)Sub-band|(% style="background-color:#f2f2f2; width:44px" %)BAT 182 182 ... ... @@ -362,7 +362,7 @@ 362 362 **Bit 0** 363 363 ))) 364 364 |(% style="width:106px" %)((( 365 - **Value**377 +Value 366 366 )))|(% style="width:71px" %)((( 367 367 Reserve 368 368 )))|(% style="width:211px" %)((( ... ... @@ -603,10 +603,8 @@ 603 603 604 604 In a normal working state: 605 605 606 -* For each uplink, the (% style="color:blue" %)**BLUE LED**(%%) or (% style="color:red" %)**RED LED**(%%) will blink once. 607 -(% style="color:blue" %)**BLUE LED**(%%) when external sensor is connected. 608 -* (% style="color:red" %)**RED LED**(%%) when external sensor is not connected 609 -* For each success downlink, the (% style="color:purple" %)**PURPLE LED**(%%) will blink once 618 +* For each uplink, the (% style="color:red" %)**RED LED**(%%) will blink once. 619 +* For each success downlink, the (% style="color:purple" %)**PURPLE LED**(%%) will blink once. 610 610 611 611 == 2.9 installation == 612 612 ... ... @@ -676,7 +676,7 @@ 676 676 [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]] 677 677 678 678 679 -== 4.3 Commands special design for LHT65N-PIR == 689 +== (% data-sider-select-id="b105c0ce-c4b4-457e-b159-018a39209e92" %)4.3 Commands special design for LHT65N-PIR(%%) == 680 680 681 681 682 682 These commands only valid for LHT65N-PIR, as below: ... ... @@ -690,7 +690,7 @@ 690 690 (% style="color:#4f81bd" %)**AT Command: ** 691 691 692 692 (% border="1" cellspacing="3" style="background-color:#f2f2f2; width:501px" %) 693 -|(% style="background-color:#4 F81BD;color:white; width:155px" %)**Command Example**|(% style="background-color:#4F81BD;color:white; width:166px" %)**Function**|(% style="background-color:#4F81BD;color:white; width:180px" %)**Response**703 +|(% style="background-color:#4f81bd; color:white; width:155px" %)**Command Example**|(% style="background-color:#4f81bd; color:white; width:166px" %)**Function**|(% style="background-color:#4f81bd; color:white; width:180px" %)**Response** 694 694 |(% style="width:155px" %)AT+TDC=?|(% style="width:162px" %)Show current transmit Interval|(% style="width:177px" %)30000 OK the interval is 30000ms = 30s 695 695 |(% style="width:155px" %)AT+TDC=60000|(% style="width:162px" %)Set Transmit Interval|(% style="width:177px" %)OK Set transmit interval to 60000ms = 60 seconds 696 696 ... ... @@ -722,7 +722,7 @@ 722 722 (% style="color:#4f81bd" %)**AT Command: ** 723 723 724 724 (% border="1" cellspacing="3" style="background-color:#f2f2f2; width:372px" %) 725 -|(% style="background-color:#4 F81BD;color:white; width:155px" %)**Command Example**|(% style="background-color:#4F81BD;color:white; width:128px" %)**Function**|(% style="background-color:#4F81BD;color:white; width:89px" %)**Response**735 +|(% style="background-color:#4f81bd; color:white; width:155px" %)**Command Example**|(% style="background-color:#4f81bd; color:white; width:128px" %)**Function**|(% style="background-color:#4f81bd; color:white; width:89px" %)**Response** 726 726 |(% style="width:155px" %)AT+PWORD=?|(% style="width:124px" %)Show password|(% style="width:86px" %)((( 727 727 123456 728 728 ... ... @@ -747,7 +747,7 @@ 747 747 (% style="color:#4f81bd" %)**AT Command: ** 748 748 749 749 (% border="1" cellspacing="3" style="background-color:#f2f2f2; width:513px" %) 750 -|(% style="background-color:#4 F81BD;color:white; width:155px" %)**Command Example**|(% style="background-color:#4F81BD;color:white; width:140px" %)**Function**|(% style="background-color:#4F81BD;color:white; width:218px" %)**Response**760 +|(% style="background-color:#4f81bd; color:white; width:155px" %)**Command Example**|(% style="background-color:#4f81bd; color:white; width:140px" %)**Function**|(% style="background-color:#4f81bd; color:white; width:218px" %)**Response** 751 751 |(% style="width:155px" %)AT+SLEEP|(% style="width:139px" %)Set to sleep mode|(% style="width:213px" %)((( 752 752 Clear all stored sensor data… 753 753 ... ... @@ -761,8 +761,10 @@ 761 761 === 4.3.5 Set UOA (Uplink on Activity) === 762 762 763 763 764 -Feature: Enable / Disable Uplink on Activity 774 +Feature: Enable / Disable Uplink on Activity. 765 765 776 +After the UOA is enabled, the LHT65N-PIR sends an uplink when the count is triggered. 777 + 766 766 (% style="color:#4f81bd" %)**AT Command: ** 767 767 768 768 * (% style="color:#037691" %)**AT+UOA=0**(%%) : Disable UoA ... ... @@ -778,10 +778,10 @@ 778 778 779 779 When followed by 3 bytes, the first byte is 01, and the second and third bytes are Calm Down Time. 780 780 781 -* (% style="color:#037691" %)**A1 00 **(%%)** ==> 782 -* (% style="color:#037691" %)**A1 01 00 02 **(%%)** ==> **793 +* (% style="color:#037691" %)**A1 00 **(%%)** ==> **AT+UOA=0** ** 794 +* (% style="color:#037691" %)**A1 01 00 02 **(%%)** ==> **AT+UOA=1,2 783 783 784 -=== 4.3.6 Get data === 796 +=== (% data-sider-select-id="50a6265d-b76f-4699-846b-b82bee3a7ab0" %)4.3.6 Get data(%%) === 785 785 786 786 787 787 Feature: Get the current sensor data ... ... @@ -788,11 +788,21 @@ 788 788 789 789 (% style="color:#4f81bd" %)**AT Command:** 790 790 791 - **AT+GETSENSORVALUE=0** ~/~/ The serial port gets the reading of the current sensor 803 +* **AT+GETSENSORVALUE=0** ~/~/ The serial port gets the reading of the current sensor 804 +* **AT+GETSENSORVALUE=1** ~/~/ The serial port gets the current sensor reading and uploads it. 792 792 793 - **AT+GETSENSORVALUE=1** ~/~/Theserialportgetsthecurrentsensorreading and uploads it.806 +=== (% data-sider-select-id="14f87315-b24f-4278-9b6c-0a8c2f35ad00" %)4.3.7 Set count number(%%) === 794 794 795 795 809 +Feature: Manually set the count number 810 + 811 +(% style="color:#4f81bd" %)**AT Command: AT+SETCNT** 812 + 813 +(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:481px" %) 814 +|=(% style="width: 162px;background-color:#4F81BD;color:white" %)**Command Example**|=(% style="width: 224px;background-color:#4F81BD;color:white" %)**Function**|=(% style="width: 95px;background-color:#4F81BD;color:white" %)**Response** 815 +|(% style="width:162px" %)AT+SETCNT=0|(% style="width:222px" %)Set the count number to 0.|(% style="width:93px" %)OK 816 +|(% style="width:162px" %)AT+SETCNT=100|(% style="width:222px" %)Set the count number to 100.|(% style="width:93px" %)OK 817 + 796 796 = 5. Battery & Power Consumption = 797 797 798 798 ... ... @@ -810,7 +810,7 @@ 810 810 * Update with new features. 811 811 * Fix bugs. 812 812 813 -Firmware and changelog can be downloaded from : **[[Firmware download link>> url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/]]**835 +Firmware and changelog can be downloaded from : **[[Firmware download link>>https://www.dropbox.com/scl/fo/ztlw35a9xbkomu71u31im/AAAJrw0bI6-cH8sPI8uQL2U/LoRaWAN%20End%20Node/LHT65N-PIR?rlkey=ojjcsw927eaow01dgooldq3nu&subfolder_nav_tracking=1&dl=0]]** 814 814 815 815 Methods to Update Firmware: 816 816 ... ... @@ -821,16 +821,8 @@ 821 821 822 822 == 7.1 How to use AT Command? == 823 823 846 +Refer this link for [[UART Hardware Connection>>url:http://wiki.dragino.com/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/#H6.1HowtoconnecttoLHT65NUARTinterface3F]]. 824 824 825 -LHT65N-PIR supports AT Command set.User can use a USB to TTL adapter plus the Program Cable to connect to LHT65 for using AT command, as below. 826 - 827 - 828 -[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615153355-1.png||_mstalt="430222"]] 829 - 830 - 831 -[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@1655802313617-381.png||_mstalt="293917"]] 832 - 833 - 834 834 In PC, User needs to set serial tool(such as [[**putty**>>https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to (% style="color:green" %)**9600** (%%)to access to access serial console for LHT65N-PIR. The AT commands are disable by default and need to enter password (default:(% style="color:green" %)**123456**(% style="color:red" %))(%%) to active it. Timeout to input AT Command is 5 min, after 5-minute, user need to input password again. User can use AT+DISAT command to disable AT command before timeout. 835 835 836 836 [[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615154519-3.png||_mstalt="431925" height="672" width="807"]] ... ... @@ -883,47 +883,11 @@ 883 883 [[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615154519-3.png||_mstalt="431925" height="672" width="807"]] 884 884 885 885 886 -== 7.4 How to u se TTL-USB to connect PC to upgrade firmware? ==900 +== 7.4 How to upgrade firmware? == 887 887 902 +Please check [[update instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/#H6.5Howtoupgradefirmware3F]]. 888 888 889 -[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615153355-1.png||_mstalt="430222"]] 890 890 891 - 892 -(% style="color:blue" %)**Step1**(%%): Install TremoProgrammer first. 893 - 894 -[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615170542-5.png||_mstalt="430638"]] 895 - 896 - 897 -(% _mstmutation="1" style="color:blue" %)**Step2**(%%):wiring method.(% style="display:none" %) 898 - 899 -First connect the four lines;(% style="display:none" %) 900 - 901 -[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220621170938-1.png||_mstalt="431340" height="413" width="419"]],(% style="display:none" %) 902 - 903 - 904 -Then use DuPont cable to short circuit port3 and port1, and then release them, so that the device enters bootlaod mode. 905 - 906 -[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220621170938-2.png||_mstalt="431704"]] 907 - 908 - 909 -(% style="color:blue" %)**Step3:**(%%)Select the device port to be connected, baud rate and bin file to be downloaded. 910 - 911 -[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615171334-6.png||_mstalt="431028"]] 912 - 913 - 914 -Click the (% style="color:blue" %)**start**(%%) button to start the firmware upgrade. 915 - 916 - 917 -When this interface appears, it indicates that the download has been completed. 918 - 919 -[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220620160723-8.png||_mstalt="430703"]] 920 - 921 - 922 -Finally, unplug the DuPont cable on port4, and then use the DuPont cable to short circuit port3 and port1 to reset the device. 923 - 924 -[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615154519-3.png||_mstalt="431925" height="672" width="807"]] 925 - 926 - 927 927 = 8. Order Info = 928 928 929 929 ... ... @@ -960,6 +960,3 @@ 960 960 (1) This device may not cause harmful interference; 961 961 962 962 (2) this device must accept any interference received, including interference that may cause undesired operation. 963 - 964 - 965 -