Changes for page LHT65N-PIR Temperature/Humidity/PIR Motion Sensor User Manual
Last modified by Xiaoling on 2025/04/24 10:00
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. ting1 +XWiki.Bei - Content
-
... ... @@ -45,7 +45,6 @@ 45 45 * External PIR Sensor 46 46 * Tri-color LED to indicate working status 47 47 48 - 49 49 (% style="display:none" %) 50 50 51 51 == 1.3 Specification == ... ... @@ -71,7 +71,6 @@ 71 71 * Cable Length : 1 meter 72 72 * Stable detect distance : 0~~3 meter 73 73 74 - 75 75 = 2. Connect LHT65N-PIR to IoT Server = 76 76 77 77 == 2.1 How does LHT65N-PIR work? == ... ... @@ -98,21 +98,16 @@ 98 98 99 99 100 100 (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 101 -|=(% style="width: 167px;background-color:#D9E2F3;color:#0070C0" %)**Behavior on **ACT|=(% style="width: 117px;background-color:#D9E2F3;color:#0070C0" %)Function|=(% style="width: 225px;background-color:#D9E2F3;color:#0070C0" %)Action99 +|=(% style="width: 167px;background-color:#D9E2F3;color:#0070C0" %)**Behavior on ACT**|=(% style="width: 117px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 225px;background-color:#D9E2F3;color:#0070C0" %)**Action** 102 102 |(% style="background-color:#f2f2f2; width:167px" %)Pressing ACT between 1s < time < 3s|(% style="background-color:#f2f2f2; width:117px" %)Test uplink status|(% style="background-color:#f2f2f2; width:225px" %)((( 103 - 104 - 105 -If LHT65N-PIR is already Joined to rhe LoRaWAN network, LHT65N-PIR will send an uplink packet, if LHT65N-PIR has external sensor connected,Blue led will blink once. If LHT65N-PIR has not external sensor, Red led will blink once. 101 +If LHT65N-PIR is already Joined to rhe LoRaWAN network, LHT65N-PIR will send an uplink packet, if LHT65N-PIR has external sensor connected,(% style="color:blue" %)**Blue led** (%%)will blink once. If LHT65N-PIR has not external sensor, (% style="color:red" %)**Red led**(%%) will blink once. 106 106 ))) 107 107 |(% style="background-color:#f2f2f2; width:167px" %)Pressing ACT for more than 3s|(% style="background-color:#f2f2f2; width:117px" %)Active Device|(% style="background-color:#f2f2f2; width:225px" %)((( 108 - 109 - 110 -Green led will fast blink 5 times, LHT65N-PIR will enter working mode and start to JOIN LoRaWAN network. 111 -Green led will solidly turn on for 5 seconds after join in network. 104 +(% style="background-color:#f2f2f2; color:green" %)**Green led**(%%) will fast blink 5 times, LHT65N-PIR will enter working mode and start to JOIN LoRaWAN network. 105 +(% style="background-color:#f2f2f2; color:green" %)**Green led**(%%) will solidly turn on for 5 seconds after join in network. 112 112 ))) 113 -|(% style="background-color:#f2f2f2; width:167px" %)Fast press ACT 5 times.|(% style="background-color:#f2f2f2; width:117px" %)Deactivate Device|(% style="background-color:#f2f2f2; width:225px" %)Red led will solid on for 5 seconds. Means LHT65N-PIR is in Deep Sleep Mode. 107 +|(% style="background-color:#f2f2f2; width:167px" %)Fast press ACT 5 times.|(% style="background-color:#f2f2f2; width:117px" %)Deactivate Device|(% style="background-color:#f2f2f2; width:225px" %)(% style="color:red" %)**Red led**(%%) will solid on for 5 seconds. Means LHT65N-PIR is in Deep Sleep Mode. 114 114 115 - 116 116 == 2.3 Example to join LoRaWAN network == 117 117 118 118 ... ... @@ -168,10 +168,10 @@ 168 168 Use ACT button to activate LHT65N-PIR and it will auto-join to the TTN V3 network. After join success, it will start to upload sensor data to TTN V3 and user can see in the panel. 169 169 170 170 171 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N-E5%20LoRaWAN%20Temperature_Humidity%20%26%20Illuminance%20Sensor%20User%20Manual/WebHome/image-20220522233300-8.png?rev=1.1||alt="image-20220522233300-8.png" height="378" width="1248"]]164 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N-E5%20LoRaWAN%20Temperature_Humidity%20%26%20Illuminance%20Sensor%20User%20Manual/WebHome/image-20220522233300-8.png?rev=1.1||alt="image-20220522233300-8.png"]] 172 172 173 173 174 -== 2.4 Uplink Payload~-~-Device Status, (Fport~=5) (%style="display:none" %) (%%)==167 +== 2.4 Uplink Payload~-~-Device Status, (Fport~=5) == 175 175 176 176 177 177 Users can use the downlink command(**0x26 01**) to ask LHT65N-PIR to send device configure detail, include device configure status. LHT65N-PIR will uplink a payload via FPort=5 to server. ... ... @@ -185,7 +185,7 @@ 185 185 186 186 Example parse in TTNv3 187 187 188 -[[image:image-20230508151932-1.png ||height="213" width="1245"]]181 +[[image:image-20230508151932-1.png]] 189 189 190 190 191 191 (% style="color:blue" %)**Sensor Model**(%%): For LHT65N-PIR, this value is 0x1A ... ... @@ -285,7 +285,6 @@ 285 285 * The 8^^th^^ byte: Alarm Bit (if this uplink is from periodically or movement) 286 286 * The 9^^th^^ ~~ 11^^st^^ byte: Movement Detect Count. 287 287 288 - 289 289 === 2.5.1 Decoder in TTN V3 === 290 290 291 291 ... ... @@ -324,7 +324,6 @@ 324 324 * BAT status=(0xcba4>>14)&0xFF=11(B),very good 325 325 * Battery Voltage =0xCBF6&0x3FFF=0x0BA4=2980mV 326 326 327 - 328 328 === 2.5.3 Built-in Temperature === 329 329 330 330 ... ... @@ -336,7 +336,6 @@ 336 336 337 337 * Temperature: (0xF5C6-65536)/100=-26.18℃ 338 338 339 - 340 340 === 2.5.4 Built-in Humidity === 341 341 342 342 ... ... @@ -344,13 +344,12 @@ 344 344 345 345 * Humidity: 0x025C/10=60.4% 346 346 347 - 348 348 === 2.5.5 Ext value === 349 349 350 350 ==== 2.5.5.1 Ext~=0x0E, PIR Sensor ==== 351 351 352 352 353 -[[image:ext=14.png||alt="image-20221224161634-2.png" height="166" width="1252"]]342 +[[image:ext=14.png||alt="image-20221224161634-2.png"]] 354 354 355 355 356 356 ==== 2.5.5.2 Ext Value ==== ... ... @@ -386,6 +386,7 @@ 386 386 0x00 E5 09 : Total detect 58633 activity since end node start. 387 387 388 388 378 + 389 389 == 2.6 Show data on Datacake == 390 390 391 391 ... ... @@ -615,7 +615,6 @@ 615 615 * (% style="color:red" %)**RED LED**(%%) when external sensor is not connected 616 616 * For each success downlink, the (% style="color:purple" %)**PURPLE LED**(%%) will blink once 617 617 618 - 619 619 == 2.9 installation == 620 620 621 621 ... ... @@ -640,7 +640,6 @@ 640 640 641 641 * 5. Do not install more than one (2 or above) Wireless PIR in the same detection space (like at the same room). 642 642 643 - 644 644 = 3. Sensors and Accessories = 645 645 646 646 == 3.1 E2 Extension Cable == ... ... @@ -672,7 +672,6 @@ 672 672 673 673 * LoRaWAN Downlink. Instruction for different platforms: See [[IoT LoRaWAN Server>>url:http://wiki.dragino.com/xwiki/bin/view/Main/]] section. 674 674 675 - 676 676 == 4.2 General Commands == 677 677 678 678 ... ... @@ -714,7 +714,6 @@ 714 714 715 715 * **Example 2**: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 716 716 717 - 718 718 === 4.3.2 Get Device Status === 719 719 720 720 ... ... @@ -769,7 +769,6 @@ 769 769 770 770 * There is no downlink command to set to Sleep mode. 771 771 772 - 773 773 === 4.3.5 Set UOA (Uplink on Activity) === 774 774 775 775 ... ... @@ -793,19 +793,6 @@ 793 793 * (% style="color:#037691" %)**A1 00 **(%%)** ==> AT+UOA=0 ** 794 794 * (% style="color:#037691" %)**A1 01 00 02 **(%%)** ==> AT+UOA=1,2** 795 795 796 - 797 -=== 4.3.6 Get data === 798 - 799 - 800 -Feature: Get the current sensor data 801 - 802 -(% style="color:#4f81bd" %)**AT Command:** 803 - 804 - **AT+GETSENSORVALUE=0** ~/~/ The serial port gets the reading of the current sensor 805 - 806 - **AT+GETSENSORVALUE=1** ~/~/ The serial port gets the current sensor reading and uploads it. 807 - 808 - 809 809 = 5. Battery & Power Consumption = 810 810 811 811 ... ... @@ -830,7 +830,6 @@ 830 830 * (Recommanded way) OTA firmware update via wireless: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/]] 831 831 * Update through UART TTL interface. **[[Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware]]**. 832 832 833 - 834 834 = 7. FAQ = 835 835 836 836 == 7.1 How to use AT Command? == ... ... @@ -954,7 +954,6 @@ 954 954 * (% style="color:#4f81bd" %)** **(% _mstmutation="1" style="color:red" %)**IN865**(%%): LoRaWAN IN865 band 955 955 * (% style="color:#4f81bd" %)** **(% _mstmutation="1" style="color:red" %)**CN470**(%%): LoRaWAN CN470 band 956 956 957 - 958 958 = 9. Packing Info = 959 959 960 960 ... ... @@ -962,13 +962,11 @@ 962 962 963 963 * LHT65N-PIR Temperature/Humidity/PIR Sensor x 1 964 964 965 - 966 966 = 10. Reference material = 967 967 968 968 969 969 * [[Datasheet, photos, decoder, firmware>>https://www.dropbox.com/sh/una19zsni308dme/AACOKp6J2RF5TMlKWT5zU3RTa?dl=0]] 970 970 971 - 972 972 = 11. FCC Warning = 973 973 974 974 ... ... @@ -977,6 +977,3 @@ 977 977 (1) This device may not cause harmful interference; 978 978 979 979 (2) this device must accept any interference received, including interference that may cause undesired operation. 980 - 981 - 982 -