From version < 47.2 >
edited by Xiaoling
on 2023/11/01 09:24
To version < 46.4 >
edited by Xiaoling
on 2023/08/16 10:40
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -100,19 +100,15 @@
100 100  
101 101  
102 102  (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %)
103 -|=(% style="width: 167px;background-color:#D9E2F3;color:#0070C0" %)**Behavior on **ACT|=(% style="width: 117px;background-color:#D9E2F3;color:#0070C0" %)Function|=(% style="width: 225px;background-color:#D9E2F3;color:#0070C0" %)Action
103 +|=(% style="width: 167px;background-color:#D9E2F3;color:#0070C0" %)**Behavior on ACT**|=(% style="width: 117px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 225px;background-color:#D9E2F3;color:#0070C0" %)**Action**
104 104  |(% style="background-color:#f2f2f2; width:167px" %)Pressing ACT between 1s < time < 3s|(% style="background-color:#f2f2f2; width:117px" %)Test uplink status|(% style="background-color:#f2f2f2; width:225px" %)(((
105 -
106 -
107 -If LHT65N-PIR is already Joined to rhe LoRaWAN network, LHT65N-PIR will send an uplink packet, if LHT65N-PIR has external sensor connected,Blue led will blink once. If LHT65N-PIR has not external sensor, Red led will blink once.
105 +If LHT65N-PIR is already Joined to rhe LoRaWAN network, LHT65N-PIR will send an uplink packet, if LHT65N-PIR has external sensor connected,(% style="color:blue" %)**Blue led** (%%)will blink once. If LHT65N-PIR has not external sensor, (% style="color:red" %)**Red led**(%%) will blink once.
108 108  )))
109 109  |(% style="background-color:#f2f2f2; width:167px" %)Pressing ACT for more than 3s|(% style="background-color:#f2f2f2; width:117px" %)Active Device|(% style="background-color:#f2f2f2; width:225px" %)(((
110 -
111 -
112 -Green led will fast blink 5 times, LHT65N-PIR will enter working mode and start to JOIN LoRaWAN network.
113 -Green led will solidly turn on for 5 seconds after join in network.
108 +(% style="background-color:#f2f2f2; color:green" %)**Green led**(%%) will fast blink 5 times, LHT65N-PIR will enter working mode and start to JOIN LoRaWAN network.
109 +(% style="background-color:#f2f2f2; color:green" %)**Green led**(%%) will solidly turn on for 5 seconds after join in network.
114 114  )))
115 -|(% style="background-color:#f2f2f2; width:167px" %)Fast press ACT 5 times.|(% style="background-color:#f2f2f2; width:117px" %)Deactivate Device|(% style="background-color:#f2f2f2; width:225px" %)Red led will solid on for 5 seconds. Means LHT65N-PIR is in Deep Sleep Mode.
111 +|(% style="background-color:#f2f2f2; width:167px" %)Fast press ACT 5 times.|(% style="background-color:#f2f2f2; width:117px" %)Deactivate Device|(% style="background-color:#f2f2f2; width:225px" %)(% style="color:red" %)**Red led**(%%) will solid on for 5 seconds. Means LHT65N-PIR is in Deep Sleep Mode.
116 116  
117 117  
118 118  
... ... @@ -171,10 +171,10 @@
171 171  Use ACT button to activate LHT65N-PIR and it will auto-join to the TTN V3 network. After join success, it will start to upload sensor data to TTN V3 and user can see in the panel.
172 172  
173 173  
174 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N-E5%20LoRaWAN%20Temperature_Humidity%20%26%20Illuminance%20Sensor%20User%20Manual/WebHome/image-20220522233300-8.png?rev=1.1||alt="image-20220522233300-8.png" height="378" width="1248"]]
170 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N-E5%20LoRaWAN%20Temperature_Humidity%20%26%20Illuminance%20Sensor%20User%20Manual/WebHome/image-20220522233300-8.png?rev=1.1||alt="image-20220522233300-8.png"]]
175 175  
176 176  
177 -== 2.4 Uplink Payload~-~-Device Status, (Fport~=5)(% style="display:none" %) (%%) ==
173 +== 2.4 Uplink Payload~-~-Device Status, (Fport~=5) ==
178 178  
179 179  
180 180  Users can use the downlink command(**0x26 01**) to ask LHT65N-PIR to send device configure detail, include device configure status. LHT65N-PIR will uplink a payload via FPort=5 to server.
... ... @@ -188,7 +188,7 @@
188 188  
189 189  Example parse in TTNv3
190 190  
191 -[[image:image-20230508151932-1.png||height="213" width="1245"]]
187 +[[image:image-20230508151932-1.png]]
192 192  
193 193  
194 194  (% style="color:blue" %)**Sensor Model**(%%): For LHT65N-PIR, this value is 0x1A
... ... @@ -357,7 +357,7 @@
357 357  ==== 2.5.5.1 Ext~=0x0E, PIR Sensor ====
358 358  
359 359  
360 -[[image:ext=14.png||alt="image-20221224161634-2.png" height="166" width="1252"]]
356 +[[image:ext=14.png||alt="image-20221224161634-2.png"]]
361 361  
362 362  
363 363  ==== 2.5.5.2 Ext Value ====
... ... @@ -422,195 +422,10 @@
422 422  
423 423  [[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20221224161957-6.png||height="306" width="852"]]
424 424  
425 -== 2.7 Alarm Mode & Feature "Multi sampling, one uplink" ==
426 426  
422 +== 2.7 LED Indicator ==
427 427  
428 -(((
429 -when the device is in alarm mode, it checks the built-in sensor temperature for a short time. if the temperature exceeds the preconfigured range, it sends an uplink immediately.
430 -)))
431 431  
432 -(((
433 -(% style="color:red" %)**Note: alarm mode adds a little power consumption, and we recommend extending the normal read time when this feature is enabled.**
434 -
435 -
436 -=== 2.7.1 ALARM MODE ( Since v1.3.1 firmware) ===
437 -
438 -
439 -**Internal GXHT30 temperature alarm(Acquisition time: fixed at one minute)**
440 -
441 -(((
442 -(% class="box infomessage" %)
443 -(((
444 -**AT+WMOD=3**:  Enable/disable alarm mode. (0: Disabled, 1: Enabled Temperature Alarm for onboard temperature sensor)
445 -
446 -**AT+CITEMP=1**:  The interval between checking the alarm temperature. (In minutes)
447 -
448 -**AT+ARTEMP**:  Gets or sets the alarm range of the internal temperature sensor
449 -
450 -(% _mstmutation="1" %)**AT+ARTEMP=? **(%%):  Gets the alarm range of the internal temperature sensor(% style="display:none" %)
451 -
452 -**AT+ARTEMP=45,105**:  Set the internal temperature sensor alarm range from 45 to 105.
453 -
454 -**AT+LEDALARM=1** :       Enable LED visual Alarm.
455 -)))
456 -)))
457 -
458 -(% style="color:#4f81bd" %)**Downlink Command:**
459 -
460 -AT+WMOD=1:  A501  , AT+WMOD=0 :  A600
461 -
462 -AT+CITEMP=1 : A60001
463 -
464 -AT+ARTEMP=1,60  :  A70001003C
465 -
466 -AT+ARTEMP=-16,60 :  A7FFF0003C
467 -
468 -AT+LEDALARM=1  :  3601
469 -
470 -
471 -(% style="color:#4f81bd" %)**Downlink Command: AAXXXXXXXXXXXXXX**
472 -
473 -Total bytes: 8 bytes
474 -
475 -**Example: **AA0100010001003C
476 -
477 -WMOD=01
478 -
479 -CITEMP=0001
480 -
481 -TEMPlow=0001
482 -
483 -TEMPhigh=003C
484 -
485 -
486 -**DS18B20 and TMP117 Threshold Alarm**
487 -
488 -**~ AT+WMOD=1,60,-10,20**
489 -
490 -(% style="color:#4f81bd" %)**Downlink Command:**
491 -
492 -**Example: **A5013CFC180014
493 -
494 -MOD=01
495 -
496 -CITEMP=3C(S)
497 -
498 -TEMPlow=FC18
499 -
500 -TEMPhigh=0014
501 -
502 -
503 -**Fluctuation alarm for DS18B20 and TMP117(Acquisition time: minimum 1s)**
504 -
505 -**AT+WMOD=2,60,5** 
506 -
507 -(% style="color:#4f81bd" %)**Downlink Command:**
508 -
509 -**Example: **A5023C05
510 -
511 -MOD=02
512 -
513 -CITEMP=3C(S)
514 -
515 -temperature fluctuation=05
516 -
517 -
518 -**Sampling multiple times and uplink together**
519 -
520 -**AT+WMOD=3,1,60,20,-16,32,1**   
521 -
522 -Explain:
523 -
524 -* (% style="color:#037691" %)**parameter1: **(%%)Set Working Mode to **Mode 3**
525 -* (% style="color:#037691" %)**parameter2:**(%%) Set the temperature sampling mode to** 1**(1:DS18B20;2:TMP117;3:** **Internal GXHT30).
526 -* (% style="color:#037691" %)**parameter3: **(%%)Sampling Interval is **60**s.
527 -* (% style="color:#037691" %)**parameter4: **(%%)When there is **20** sampling dats, Device will send these data via one uplink. (max value is 60, means max 60 sampling in one uplink)
528 -* (% style="color:#037691" %)**parameter5 & parameter6: **(%%)Temperature alarm range is **-16** to **32**°C,
529 -* (% style="color:#037691" %)**parameter7:**(%%) 1 to enable temperature alarm, **0** to disable the temperature alarm. If alarm is enabled, a data will be sent immediately  if temperate exceeds the Alarm range.
530 -
531 -(% style="color:#4f81bd" %)**Downlink Command:**
532 -
533 -**Example: **A50301003C14FFF0002001
534 -
535 -MOD=03
536 -
537 -TEMP=DS18B20
538 -
539 -CITEMP=003C(S)
540 -
541 -Total number of acquisitions=14
542 -
543 -TEMPlow=FFF0
544 -
545 -TEMPhigh=0020
546 -
547 -ARTEMP=01
548 -
549 -
550 -**Uplink payload( Fport=3)**
551 -
552 -**Example: CBEA**01**0992**//0A41//**09C4**
553 -
554 -BatV=CBEA
555 -
556 -TEMP=DS18B20
557 -
558 -Temp1=0992  ~/~/ 24.50℃
559 -
560 -Temp2=0A41  ~/~/ 26.25℃
561 -
562 -Temp3=09C4  ~/~/ 25.00℃
563 -
564 -(% style="color:red" %)**Note: This uplink will automatically select the appropriate DR according to the data length**
565 -
566 -(% style="color:red" %)** In this mode, the temperature resolution of ds18b20 is 0.25℃ to save power consumption**
567 -)))
568 -
569 -
570 -=== 2.7.2 ALARM MODE ( Before v1.3.1 firmware) ===
571 -
572 -
573 -(% class="box infomessage" %)
574 -(((
575 -(((
576 -**AT+WMOD=1**:  Enable/disable alarm mode. (0: Disabled, 1: Enabled Temperature Alarm for onboard temperature sensor)
577 -)))
578 -
579 -(((
580 -**AT+CITEMP=1**:  The interval between checking the alarm temperature. (In minutes)
581 -)))
582 -
583 -(((
584 -**AT+ARTEMP**:  Gets or sets the alarm range of the internal temperature sensor
585 -)))
586 -
587 -(((
588 -(% _mstmutation="1" %)**AT+ARTEMP=? **(%%):  Gets the alarm range of the internal temperature sensor(% style="display:none" %)
589 -)))
590 -
591 -(((
592 -**AT+ARTEMP=45,105**:  Set the internal temperature sensor alarm range from 45 to 105.
593 -)))
594 -)))
595 -
596 -(% style="color:#4f81bd" %)**Downlink Command: AAXXXXXXXXXXXXXX**
597 -
598 -Total bytes: 8 bytes
599 -
600 -**Example:**AA0100010001003C
601 -
602 -WMOD=01
603 -
604 -CITEMP=0001
605 -
606 -TEMPlow=0001
607 -
608 -TEMPhigh=003C
609 -
610 -
611 -== 2.8 LED Indicator ==
612 -
613 -
614 614  The LHT65N-PIR has a triple color LED which for easy showing different stage .
615 615  
616 616  While user press ACT button, the LED will work as per LED status with ACT button.
... ... @@ -624,7 +624,7 @@
624 624  
625 625  
626 626  
627 -== 2.9 installation ==
438 +== 2.8 installation ==
628 628  
629 629  
630 630  ~1. Don't install LHT65N-PIR outdoor or place where will get wet.
... ... @@ -982,6 +982,3 @@
982 982  (1) This device may not cause harmful interference;
983 983  
984 984  (2) this device must accept any interference received, including interference that may cause undesired operation.
985 -
986 -
987 -
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0