Changes for page LHT65N-PIR Temperature/Humidity/PIR Motion Sensor User Manual
Last modified by Xiaoling on 2025/04/24 10:00
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Bei1 +XWiki.Xiaoling - Content
-
... ... @@ -187,35 +187,34 @@ 187 187 188 188 (% style="color:blue" %)**Frequency Band**: 189 189 190 -0x01: EU868 190 +*0x01: EU868 191 191 192 -0x02: US915 192 +*0x02: US915 193 193 194 -0x03: IN865 194 +*0x03: IN865 195 195 196 -0x04: AU915 196 +*0x04: AU915 197 197 198 -0x05: KZ865 198 +*0x05: KZ865 199 199 200 -0x06: RU864 200 +*0x06: RU864 201 201 202 -0x07: AS923 202 +*0x07: AS923 203 203 204 -0x08: AS923-1 204 +*0x08: AS923-1 205 205 206 -0x09: AS923-2 206 +*0x09: AS923-2 207 207 208 -0x0a: AS923-3 208 +*0x0a: AS923-3 209 209 210 -0x0b: CN470 210 +*0x0b: CN470 211 211 212 -0x0c: EU433 212 +*0x0c: EU433 213 213 214 -0x0d: KR920 214 +*0x0d: KR920 215 215 216 -0x0e: MA869 216 +*0x0e: MA869 217 217 218 - 219 219 (% style="color:blue" %)**Sub-Band**: 220 220 221 221 AU915 and US915: value 0x00 ~~ 0x08 ... ... @@ -224,7 +224,6 @@ 224 224 225 225 Other Bands: Always 0x00 226 226 227 - 228 228 (% style="color:blue" %)**Battery Info**: 229 229 230 230 Check the battery voltage. ... ... @@ -375,7 +375,6 @@ 375 375 0x00 E5 09 : Total detect 58633 activity since end node start. 376 376 377 377 378 - 379 379 == 2.6 Show data on Datacake == 380 380 381 381 ... ... @@ -405,195 +405,10 @@ 405 405 406 406 [[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20221224161957-6.png||height="306" width="852"]] 407 407 408 -== 2.7 Alarm Mode & Feature "Multi sampling, one uplink" == 409 409 406 +== 2.7 LED Indicator == 410 410 411 -((( 412 -when the device is in alarm mode, it checks the built-in sensor temperature for a short time. if the temperature exceeds the preconfigured range, it sends an uplink immediately. 413 -))) 414 414 415 -((( 416 -(% style="color:red" %)**Note: alarm mode adds a little power consumption, and we recommend extending the normal read time when this feature is enabled.** 417 - 418 - 419 -=== 2.7.1 ALARM MODE ( Since v1.3.1 firmware) === 420 - 421 - 422 -**Internal GXHT30 temperature alarm(Acquisition time: fixed at one minute)** 423 - 424 -((( 425 -(% class="box infomessage" %) 426 -((( 427 -**AT+WMOD=3**: Enable/disable alarm mode. (0: Disabled, 1: Enabled Temperature Alarm for onboard temperature sensor) 428 - 429 -**AT+CITEMP=1**: The interval between checking the alarm temperature. (In minutes) 430 - 431 -**AT+ARTEMP**: Gets or sets the alarm range of the internal temperature sensor 432 - 433 -(% _mstmutation="1" %)**AT+ARTEMP=? **(%%): Gets the alarm range of the internal temperature sensor(% style="display:none" %) 434 - 435 -**AT+ARTEMP=45,105**: Set the internal temperature sensor alarm range from 45 to 105. 436 - 437 -**AT+LEDALARM=1** : Enable LED visual Alarm. 438 -))) 439 -))) 440 - 441 -(% style="color:#4f81bd" %)**Downlink Command:** 442 - 443 -AT+WMOD=1: A501 , AT+WMOD=0 : A600 444 - 445 -AT+CITEMP=1 : A60001 446 - 447 -AT+ARTEMP=1,60 : A70001003C 448 - 449 -AT+ARTEMP=-16,60 : A7FFF0003C 450 - 451 -AT+LEDALARM=1 : 3601 452 - 453 - 454 -(% style="color:#4f81bd" %)**Downlink Command: AAXXXXXXXXXXXXXX** 455 - 456 -Total bytes: 8 bytes 457 - 458 -**Example: **AA0100010001003C 459 - 460 -WMOD=01 461 - 462 -CITEMP=0001 463 - 464 -TEMPlow=0001 465 - 466 -TEMPhigh=003C 467 - 468 - 469 -**DS18B20 and TMP117 Threshold Alarm** 470 - 471 -**~ AT+WMOD=1,60,-10,20** 472 - 473 -(% style="color:#4f81bd" %)**Downlink Command:** 474 - 475 -**Example: **A5013CFC180014 476 - 477 -MOD=01 478 - 479 -CITEMP=3C(S) 480 - 481 -TEMPlow=FC18 482 - 483 -TEMPhigh=0014 484 - 485 - 486 -**Fluctuation alarm for DS18B20 and TMP117(Acquisition time: minimum 1s)** 487 - 488 -**AT+WMOD=2,60,5** 489 - 490 -(% style="color:#4f81bd" %)**Downlink Command:** 491 - 492 -**Example: **A5023C05 493 - 494 -MOD=02 495 - 496 -CITEMP=3C(S) 497 - 498 -temperature fluctuation=05 499 - 500 - 501 -**Sampling multiple times and uplink together** 502 - 503 -**AT+WMOD=3,1,60,20,-16,32,1** 504 - 505 -Explain: 506 - 507 -* (% style="color:#037691" %)**parameter1: **(%%)Set Working Mode to **Mode 3** 508 -* (% style="color:#037691" %)**parameter2:**(%%) Set the temperature sampling mode to** 1**(1:DS18B20;2:TMP117;3:** **Internal GXHT30). 509 -* (% style="color:#037691" %)**parameter3: **(%%)Sampling Interval is **60**s. 510 -* (% style="color:#037691" %)**parameter4: **(%%)When there is **20** sampling dats, Device will send these data via one uplink. (max value is 60, means max 60 sampling in one uplink) 511 -* (% style="color:#037691" %)**parameter5 & parameter6: **(%%)Temperature alarm range is **-16** to **32**°C, 512 -* (% style="color:#037691" %)**parameter7:**(%%) 1 to enable temperature alarm, **0** to disable the temperature alarm. If alarm is enabled, a data will be sent immediately if temperate exceeds the Alarm range. 513 - 514 -(% style="color:#4f81bd" %)**Downlink Command:** 515 - 516 -**Example: **A50301003C14FFF0002001 517 - 518 -MOD=03 519 - 520 -TEMP=DS18B20 521 - 522 -CITEMP=003C(S) 523 - 524 -Total number of acquisitions=14 525 - 526 -TEMPlow=FFF0 527 - 528 -TEMPhigh=0020 529 - 530 -ARTEMP=01 531 - 532 - 533 -**Uplink payload( Fport=3)** 534 - 535 -**Example: CBEA**01**0992**//0A41//**09C4** 536 - 537 -BatV=CBEA 538 - 539 -TEMP=DS18B20 540 - 541 -Temp1=0992 ~/~/ 24.50℃ 542 - 543 -Temp2=0A41 ~/~/ 26.25℃ 544 - 545 -Temp3=09C4 ~/~/ 25.00℃ 546 - 547 -(% style="color:red" %)**Note: This uplink will automatically select the appropriate DR according to the data length** 548 - 549 -(% style="color:red" %)** In this mode, the temperature resolution of ds18b20 is 0.25℃ to save power consumption** 550 -))) 551 - 552 - 553 -=== 2.7.2 ALARM MODE ( Before v1.3.1 firmware) === 554 - 555 - 556 -(% class="box infomessage" %) 557 -((( 558 -((( 559 -**AT+WMOD=1**: Enable/disable alarm mode. (0: Disabled, 1: Enabled Temperature Alarm for onboard temperature sensor) 560 -))) 561 - 562 -((( 563 -**AT+CITEMP=1**: The interval between checking the alarm temperature. (In minutes) 564 -))) 565 - 566 -((( 567 -**AT+ARTEMP**: Gets or sets the alarm range of the internal temperature sensor 568 -))) 569 - 570 -((( 571 -(% _mstmutation="1" %)**AT+ARTEMP=? **(%%): Gets the alarm range of the internal temperature sensor(% style="display:none" %) 572 -))) 573 - 574 -((( 575 -**AT+ARTEMP=45,105**: Set the internal temperature sensor alarm range from 45 to 105. 576 -))) 577 -))) 578 - 579 -(% style="color:#4f81bd" %)**Downlink Command: AAXXXXXXXXXXXXXX** 580 - 581 -Total bytes: 8 bytes 582 - 583 -**Example:**AA0100010001003C 584 - 585 -WMOD=01 586 - 587 -CITEMP=0001 588 - 589 -TEMPlow=0001 590 - 591 -TEMPhigh=003C 592 - 593 - 594 -== 2.8 LED Indicator == 595 - 596 - 597 597 The LHT65N-PIR has a triple color LED which for easy showing different stage . 598 598 599 599 While user press ACT button, the LED will work as per LED status with ACT button. ... ... @@ -605,7 +605,7 @@ 605 605 * (% style="color:red" %)**RED LED**(%%) when external sensor is not connected 606 606 * For each success downlink, the (% style="color:purple" %)**PURPLE LED**(%%) will blink once 607 607 608 -== 2. 9installation ==420 +== 2.8 installation == 609 609 610 610 611 611 ~1. Don't install LHT65N-PIR outdoor or place where will get wet. ... ... @@ -684,11 +684,11 @@ 684 684 685 685 Feature: Change LoRaWAN End Node Transmit Interval. 686 686 687 -(% style="color:#4f81bd" %)**AT Command: ** 499 +(% style="color:#4f81bd" %)**AT Command: AT+TDC** 688 688 689 689 (% border="1" cellspacing="5" style="background-color:#f2f2f2; width:501px" %) 690 690 |(% style="background-color:#d9e2f3; color:#0070c0; width:155px" %)**Command Example**|(% style="background-color:#d9e2f3; color:#0070c0; width:166px" %)**Function**|(% style="background-color:#d9e2f3; color:#0070c0; width:180px" %)**Response** 691 -|(% style="width:155px" %)AT+TDC =?|(% style="width:162px" %)Show current transmit Interval|(% style="width:177px" %)30000 OK the interval is 30000ms = 30s503 +|(% style="width:155px" %)AT+TDC?|(% style="width:162px" %)Show current transmit Interval|(% style="width:177px" %)30000 OK the interval is 30000ms = 30s 692 692 |(% style="width:155px" %)AT+TDC=60000|(% style="width:162px" %)Set Transmit Interval|(% style="width:177px" %)OK Set transmit interval to 60000ms = 60 seconds 693 693 694 694 (% style="color:#4f81bd" %)**Downlink Payload: 0x01** ... ... @@ -716,7 +716,7 @@ 716 716 717 717 Feature: Set device password, max 9 digits 718 718 719 -(% style="color:#4f81bd" %)**AT Command: ** 531 +(% style="color:#4f81bd" %)**AT Command: AT+PWORD** 720 720 721 721 (% border="1" cellspacing="5" style="background-color:#f2f2f2; width:372px" %) 722 722 |(% style="background-color:#d9e2f3; color:#0070c0; width:155px" %)**Command Example**|(% style="background-color:#d9e2f3; color:#0070c0; width:128px" %)**Function**|(% style="background-color:#d9e2f3; color:#0070c0; width:89px" %)**Response** ... ... @@ -775,9 +775,12 @@ 775 775 776 776 When followed by 3 bytes, the first byte is 01, and the second and third bytes are Calm Down Time. 777 777 778 -* (% style="color:#037691" %)**A1 00 **(%%)**==> AT+UOA=0 **779 -* (% style="color:#037691" %)**A1 01 00 02 **(%%)**==> AT+UOA=1,2**590 +* (% style="color:#037691" %)**A1 00 (%%) ==> AT+UOA=0 ** 591 +* (% style="color:#037691" %)**A1 01 00 02 (%%) ==> AT+UOA=1,2** 780 780 593 + 594 + 595 + 781 781 = 5. Battery & Power Consumption = 782 782 783 783 ... ... @@ -813,6 +813,7 @@ 813 813 [[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615153355-1.png||_mstalt="430222"]] 814 814 815 815 631 + 816 816 [[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@1655802313617-381.png||_mstalt="293917"]] 817 817 818 818 ... ... @@ -873,12 +873,10 @@ 873 873 874 874 [[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615153355-1.png||_mstalt="430222"]] 875 875 876 - 877 877 (% style="color:blue" %)**Step1**(%%): Install TremoProgrammer first. 878 878 879 879 [[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615170542-5.png||_mstalt="430638"]] 880 880 881 - 882 882 (% _mstmutation="1" style="color:blue" %)**Step2**(%%):wiring method.(% style="display:none" %) 883 883 884 884 First connect the four lines;(% style="display:none" %) ... ... @@ -891,6 +891,7 @@ 891 891 [[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220621170938-2.png||_mstalt="431704"]] 892 892 893 893 708 + 894 894 (% style="color:blue" %)**Step3:**(%%)Select the device port to be connected, baud rate and bin file to be downloaded. 895 895 896 896 [[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615171334-6.png||_mstalt="431028"]] ... ... @@ -906,6 +906,8 @@ 906 906 907 907 Finally, unplug the DuPont cable on port4, and then use the DuPont cable to short circuit port3 and port1 to reset the device. 908 908 724 + 725 + 909 909 [[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615154519-3.png||_mstalt="431925" height="672" width="807"]] 910 910 911 911