Changes for page LHT65N-PIR Temperature/Humidity/PIR Motion Sensor User Manual
Last modified by Xiaoling on 2025/06/10 09:17
From version 45.1
edited by Edwin Chen
on 2023/05/24 16:01
on 2023/05/24 16:01
Change comment:
There is no comment for this version
To version 40.1
edited by Ellie Zhang
on 2023/05/06 10:51
on 2023/05/06 10:51
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 2 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki.E dwin1 +XWiki.Ellie - Content
-
... ... @@ -1,9 +1,13 @@ 1 1 (% style="text-align:center" %) 2 -[[image:LHT65N-PIR1.jpg||alt="image-20221206143242-2.png" height=" 484" width="485"]]2 +[[image:LHT65N-PIR1.jpg||alt="image-20221206143242-2.png" height="679" width="681"]] 3 3 4 4 5 5 6 6 7 + 8 + 9 + 10 + 7 7 **Table of Contents:** 8 8 9 9 {{toc/}} ... ... @@ -13,6 +13,9 @@ 13 13 14 14 15 15 20 + 21 + 22 + 16 16 = 1. Introduction = 17 17 18 18 == 1.1 What is LHT65N-PIR Temperature,Humidity & PIR Sensor == ... ... @@ -63,11 +63,13 @@ 63 63 * Long Term Drift: < 0.02 °C/yr 64 64 * Operating Range: 0 ~~ 96 %RH 65 65 66 -(% style="color:#037691" %)**External PIR Sensor:** 73 +(% class="mark" style="color:#037691" %)**External PIR Sensor:** 67 67 68 -* Base on RDB223 Sensor 69 -* Cable Length : 1 meter 70 -* Stable detect distance : 0~~3 meter 75 +* (% class="mark" %)Base on BH1750 Illumination Sensor 76 +* (% class="mark" %)Cable Length : 50cm 77 +* (% class="mark" %)Resolution: 1 lx 78 +* (% class="mark" %)Range: 0-65535 lx 79 +* (% class="mark" %)Operating Range: -40 °C ~~ 85 °C 71 71 72 72 73 73 = 2. Connect LHT65N-PIR to IoT Server = ... ... @@ -128,7 +128,7 @@ 128 128 129 129 Each LHT65N-PIR is shipped with a sticker with its device EUI, APP Key and APP EUI as below: 130 130 131 -[[image:image-20230426083533-1.png ||height="286" width="616"]]140 +[[image:image-20230426083533-1.png]] 132 132 133 133 134 134 User can enter these keys in the LoRaWAN Server portal. Below is TTN V3 screenshot: ... ... @@ -179,9 +179,8 @@ 179 179 180 180 Example parse in TTNv3 181 181 182 -[[image: image-20230508151932-1.png]]191 +[[image:1FPORT=5.png||alt="1675144504430-490.png" height="265" width="1150"]] 183 183 184 - 185 185 **Sensor Model**: For LHT65N-PIR, this value is 0x1A 186 186 187 187 **Firmware Version**: 0x0100, Means: v1.0.0 version ... ... @@ -337,12 +337,11 @@ 337 337 338 338 === 2.5.5 Ext value === 339 339 340 -==== 2.5.5.1 Ext~=0x0 E, PIR Sensor ====348 +==== 2.5.5.1 Ext~=0x0A, PIR Sensor ==== 341 341 350 +[[image:image-20221224161634-2.png||height="138" width="851"]] 342 342 343 -[[image:ext=14.png||alt="image-20221224161634-2.png"]] 344 344 345 - 346 346 ==== 2.5.5.2 Ext Value ==== 347 347 348 348 ... ... @@ -365,6 +365,7 @@ 365 365 )))|(% style="width:211px" %)((( 366 366 ((( 367 367 0: Normal Uplink 375 + 368 368 1: Uplink by activity detected 369 369 ))) 370 370 ))) ... ... @@ -416,10 +416,10 @@ 416 416 417 417 In a normal working state: 418 418 419 -* For each uplink, the (% style="color:blue" %)**BLUE LED**(%%)or(% style="color:red" %)**RED LED**(%%)will blink once.420 - (% style="color:blue" %)**BLUE LED**(%%)when external sensor is connected.421 -* (% style="color:red" %)**RED LED**(%%)when external sensor is not connected422 -* For each success downlink, the (% style="color:purple" %)**PURPLE LED**(%%)will blink once427 +* For each uplink, the **BLUE LED** or **RED LED** will blink once. 428 +**BLUE LED** when external sensor is connected. 429 +* **RED LED** when external sensor is not connected 430 +* For each success downlink, the PURPLE LED will blink once 423 423 424 424 425 425 == 2.8 installation == ... ... @@ -433,17 +433,12 @@ 433 433 434 434 [[image:image-20230411135341-1.png||height="450" width="456"]] 435 435 436 - 437 437 (% style="color:red" %)**Notice: PIR can only detect motion activity, not to use to detect static people case.** 438 438 439 439 * 1. PIR Motion Detector should not be installed near the Air conditioner places where with cold wind or hot wind flow, because PIR motion detector is sensitive with the temperature changes of the environment. Environment changes quickly will cause a false alarm. 440 - 441 441 * 2. PIR should not be installed facing the glass window, facing glass window will be interfered by the outside sunlight and moving objects (people or vehicle). The infrared energy can penetrate the glass window. 442 - 443 443 * 3. PIR should not be installed facing the moving objects or background changing objects, movement object will cause airflow change, it may cause false alarm. 444 - 445 445 * 4. Between the detection range of PIR Motion detector, there is should be less objects. Many objects may reduce the sensitive of detection range. 446 - 447 447 * 5. Do not install more than one (2 or above) Wireless PIR in the same detection space (like at the same room). 448 448 449 449 ... ... @@ -475,7 +475,6 @@ 475 475 LHT65N-PIR supports below configure method: 476 476 477 477 * AT Command via UART Connection : See [[FAQ>>||anchor="H7.FAQ"]]. 478 - 479 479 * LoRaWAN Downlink. Instruction for different platforms: See [[IoT LoRaWAN Server>>url:http://wiki.dragino.com/xwiki/bin/view/Main/]] section. 480 480 481 481
- ext=14.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ellie - Size
-
... ... @@ -1,1 +1,0 @@ 1 -30.5 KB - Content
- image-20230508151932-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.kai - Size
-
... ... @@ -1,1 +1,0 @@ 1 -36.0 KB - Content