Changes for page LHT65N-PIR Temperature/Humidity/PIR Motion Sensor User Manual
Last modified by Xiaoling on 2025/06/10 09:17
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -43,10 +43,12 @@ 43 43 * Built-in 2400mAh battery for up to 5 years of use. 44 44 * Built-in Temperature & Humidity sensor 45 45 * External PIR Sensor 46 -* Tri-color LED to indicate working status (% style="display:none" %)46 +* Tri-color LED to indicate working status 47 47 48 48 49 49 50 +(% style="display:none" %) 51 + 50 50 == 1.3 Specification == 51 51 52 52 ... ... @@ -64,13 +64,11 @@ 64 64 * Long Term Drift: < 0.02 °C/yr 65 65 * Operating Range: 0 ~~ 96 %RH 66 66 67 -(% class="mark" style="color:#037691" %)**External PIR Sensor:**69 +(% style="color:#037691" %)**External PIR Sensor:** 68 68 69 -* (% class="mark" %)Base on BH1750 Illumination Sensor 70 -* (% class="mark" %)Cable Length : 50cm 71 -* (% class="mark" %)Resolution: 1 lx 72 -* (% class="mark" %)Range: 0-65535 lx 73 -* (% class="mark" %)Operating Range: -40 °C ~~ 85 °C 71 +* Base on RDB223 Sensor 72 +* Cable Length : 1 meter 73 +* Stable detect distance : 0~~3 meter 74 74 75 75 76 76 ... ... @@ -187,11 +187,11 @@ 187 187 [[image:image-20230508151932-1.png]] 188 188 189 189 190 -**Sensor Model**: For LHT65N-PIR, this value is 0x1A 190 +(% style="color:blue" %)**Sensor Model**(%%): For LHT65N-PIR, this value is 0x1A 191 191 192 -**Firmware Version**: 0x0100, Means: v1.0.0 version 192 +(% style="color:blue" %)**Firmware Version**(%%): 0x0100, Means: v1.0.0 version 193 193 194 -**Frequency Band**: 194 +(% style="color:blue" %)**Frequency Band**: 195 195 196 196 *0x01: EU868 197 197 ... ... @@ -221,15 +221,15 @@ 221 221 222 222 *0x0e: MA869 223 223 224 -**Sub-Band**: 224 +(% style="color:blue" %)**Sub-Band**: 225 225 226 -AU915 and US915:value 0x00 ~~ 0x08 226 +AU915 and US915: value 0x00 ~~ 0x08 227 227 228 228 CN470: value 0x0B ~~ 0x0C 229 229 230 230 Other Bands: Always 0x00 231 231 232 -**Battery Info**: 232 +(% style="color:blue" %)**Battery Info**: 233 233 234 234 Check the battery voltage. 235 235 ... ... @@ -246,21 +246,21 @@ 246 246 After each uplink, the (% style="color:blue" %)**BLUE LED**(%%) will blink once. 247 247 248 248 (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:390px" %) 249 -|=(% style="width: 60px;background-color:#D9E2F3" %)((( 249 +|=(% style="width: 60px;background-color:#D9E2F3;color:#0070C0" %)((( 250 250 **Size(bytes)** 251 -)))|=(% style="width: 30px;background-color:#D9E2F3" %)((( 251 +)))|=(% style="width: 30px;background-color:#D9E2F3;color:#0070C0" %)((( 252 252 **2** 253 -)))|=(% style="width: 100px;background-color:#D9E2F3" %)((( 253 +)))|=(% style="width: 100px;background-color:#D9E2F3;color:#0070C0" %)((( 254 254 **2** 255 -)))|=(% style="width: 100px;background-color:#D9E2F3" %)((( 255 +)))|=(% style="width: 100px;background-color:#D9E2F3;color:#0070C0" %)((( 256 256 **2** 257 -)))|=(% style="width: 50px;background-color:#D9E2F3" %)((( 257 +)))|=(% style="width: 50px;background-color:#D9E2F3;color:#0070C0" %)((( 258 258 **1** 259 -)))|=(% style="width: 50px;background-color:#D9E2F3" %)((( 259 +)))|=(% style="width: 50px;background-color:#D9E2F3;color:#0070C0" %)((( 260 260 **4** 261 261 ))) 262 262 |(% style="width:97px" %)((( 263 - **Value**263 +Value 264 264 )))|(% style="width:39px" %)((( 265 265 [[BAT>>||anchor="H2.5.2BAT-BatteryInfo"]] 266 266 )))|(% style="width:100px" %)((( ... ... @@ -305,7 +305,7 @@ 305 305 **Bit(bit)** 306 306 )))|=(% style="width: 253px;background-color:#D9E2F3;color:#0070C0" %)[15:14]|=(% style="width: 155px;background-color:#D9E2F3;color:#0070C0" %)[13:0] 307 307 |(% style="width:66px" %)((( 308 - **Value**308 +Value 309 309 )))|(% style="width:250px" %)((( 310 310 BAT Status 311 311 00(b): Ultra Low ( BAT <= 2.50v) ... ... @@ -326,6 +326,7 @@ 326 326 327 327 === 2.5.3 Built-in Temperature === 328 328 329 + 329 329 [[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220522235639-2.png||_mstalt="431756" height="138" width="722"]] 330 330 331 331 * Temperature: 0x0ABB/100=27.47℃ ... ... @@ -338,6 +338,7 @@ 338 338 339 339 === 2.5.4 Built-in Humidity === 340 340 342 + 341 341 [[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220522235639-4.png||_mstalt="432484" height="138" width="722"]] 342 342 343 343 * Humidity: 0x025C/10=60.4% ... ... @@ -360,11 +360,11 @@ 360 360 Bit0 of byte 8th shows if this uplink is generate by PIR activity. 361 361 362 362 (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:393px" %) 363 -|=(% style="width: 10 6px; background-color:rgb(217, 226, 243);rgb(0, 112, 192);" %)(((365 +|=(% style="width: 107px; background-color:#D9E2F3;color:#0070C0" %)((( 364 364 **The 8^^th^^ byte** 365 -)))|=(% style="width: 7 1px; background-color:rgb(217, 226, 243);rgb(0, 112, 192);" %)(((367 +)))|=(% style="width: 73px; background-color:#D9E2F3;color:#0070C0" %)((( 366 366 **Bit 1~~7** 367 -)))|=(% style="width: 21 1px; background-color:rgb(217, 226, 243);rgb(0, 112, 192);" %)(((369 +)))|=(% style="width: 213px; background-color:#D9E2F3;color:#0070C0" %)((( 368 368 **Bit 0** 369 369 ))) 370 370 |(% style="width:106px" %)((( ... ... @@ -415,7 +415,6 @@ 415 415 [[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20221224161957-6.png||height="306" width="852"]] 416 416 417 417 418 - 419 419 == 2.7 LED Indicator == 420 420 421 421