Changes for page LHT65N-PIR Temperature/Humidity/PIR Motion Sensor User Manual
Last modified by Xiaoling on 2025/04/24 10:00
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -45,8 +45,6 @@ 45 45 * External PIR Sensor 46 46 * Tri-color LED to indicate working status(% style="display:none" %) 47 47 48 - 49 - 50 50 == 1.3 Specification == 51 51 52 52 ... ... @@ -72,8 +72,6 @@ 72 72 * (% class="mark" %)Range: 0-65535 lx 73 73 * (% class="mark" %)Operating Range: -40 °C ~~ 85 °C 74 74 75 - 76 - 77 77 = 2. Connect LHT65N-PIR to IoT Server = 78 78 79 79 == 2.1 How does LHT65N-PIR work? == ... ... @@ -110,8 +110,6 @@ 110 110 ))) 111 111 |(% style="background-color:#f2f2f2; width:167px" %)Fast press ACT 5 times.|(% style="background-color:#f2f2f2; width:117px" %)Deactivate Device|(% style="background-color:#f2f2f2; width:225px" %)(% style="color:red" %)**Red led**(%%) will solid on for 5 seconds. Means LHT65N is in Deep Sleep Mode. 112 112 113 - 114 - 115 115 == 2.3 Example to join LoRaWAN network == 116 116 117 117 ... ... @@ -186,7 +186,6 @@ 186 186 187 187 [[image:image-20230508151932-1.png]] 188 188 189 - 190 190 **Sensor Model**: For LHT65N-PIR, this value is 0x1A 191 191 192 192 **Firmware Version**: 0x0100, Means: v1.0.0 version ... ... @@ -282,8 +282,6 @@ 282 282 * The 8^^th^^ byte: Alarm Bit (if this uplink is from periodically or movement) 283 283 * The 9^^th^^ ~~ 11^^st^^ byte: Movement Detect Count. 284 284 285 - 286 - 287 287 === 2.5.1 Decoder in TTN V3 === 288 288 289 289 ... ... @@ -322,8 +322,6 @@ 322 322 * BAT status=(0xcba4>>14)&0xFF=11(B),very good 323 323 * Battery Voltage =0xCBF6&0x3FFF=0x0BA4=2980mV 324 324 325 - 326 - 327 327 === 2.5.3 Built-in Temperature === 328 328 329 329 [[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220522235639-2.png||_mstalt="431756" height="138" width="722"]] ... ... @@ -334,8 +334,6 @@ 334 334 335 335 * Temperature: (0xF5C6-65536)/100=-26.18℃ 336 336 337 - 338 - 339 339 === 2.5.4 Built-in Humidity === 340 340 341 341 [[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220522235639-4.png||_mstalt="432484" height="138" width="722"]] ... ... @@ -342,13 +342,10 @@ 342 342 343 343 * Humidity: 0x025C/10=60.4% 344 344 345 - 346 - 347 347 === 2.5.5 Ext value === 348 348 349 349 ==== 2.5.5.1 Ext~=0x0E, PIR Sensor ==== 350 350 351 - 352 352 [[image:ext=14.png||alt="image-20221224161634-2.png"]] 353 353 354 354 ... ... @@ -425,13 +425,11 @@ 425 425 426 426 In a normal working state: 427 427 428 -* For each uplink, the (% style="color:blue" %) **BLUE LED**(%%) or (% style="color:red" %)**RED LED**(%%) will blink once.412 +* For each uplink, the **(% style="color:blue" %)BLUE LED**(%%) or (% style="color:red" %)**RED LED**(%%) will blink once. 429 429 (% style="color:blue" %)**BLUE LED**(%%) when external sensor is connected. 430 430 * (% style="color:red" %)**RED LED**(%%) when external sensor is not connected 431 431 * For each success downlink, the (% style="color:purple" %)**PURPLE LED**(%%) will blink once 432 432 433 - 434 - 435 435 == 2.8 installation == 436 436 437 437 ... ... @@ -443,7 +443,6 @@ 443 443 444 444 [[image:image-20230411135341-1.png||height="450" width="456"]] 445 445 446 - 447 447 (% style="color:red" %)**Notice: PIR can only detect motion activity, not to use to detect static people case.** 448 448 449 449 * 1. PIR Motion Detector should not be installed near the Air conditioner places where with cold wind or hot wind flow, because PIR motion detector is sensitive with the temperature changes of the environment. Environment changes quickly will cause a false alarm. ... ... @@ -456,8 +456,6 @@ 456 456 457 457 * 5. Do not install more than one (2 or above) Wireless PIR in the same detection space (like at the same room). 458 458 459 - 460 - 461 461 = 3. Sensors and Accessories = 462 462 463 463 == 3.1 E2 Extension Cable == ... ... @@ -489,8 +489,6 @@ 489 489 490 490 * LoRaWAN Downlink. Instruction for different platforms: See [[IoT LoRaWAN Server>>url:http://wiki.dragino.com/xwiki/bin/view/Main/]] section. 491 491 492 - 493 - 494 494 == 4.2 General Commands == 495 495 496 496 ... ... @@ -532,8 +532,6 @@ 532 532 533 533 * **Example 2**: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 534 534 535 - 536 - 537 537 === 4.3.2 Get Device Status === 538 538 539 539 ... ... @@ -588,8 +588,6 @@ 588 588 589 589 * There is no downlink command to set to Sleep mode. 590 590 591 - 592 - 593 593 === 4.3.5 Set UOA (Uplink on Activity) === 594 594 595 595 ... ... @@ -631,8 +631,6 @@ 631 631 * (Recommanded way) OTA firmware update via wireless: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/]] 632 632 * Update through UART TTL interface. **[[Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware]]**. 633 633 634 - 635 - 636 636 = 7. FAQ = 637 637 638 638 == 7.1 How to use AT Command? == ... ... @@ -758,8 +758,6 @@ 758 758 * (% style="color:#4f81bd" %)** **(% _mstmutation="1" style="color:red" %)**IN865**(%%): LoRaWAN IN865 band 759 759 * (% style="color:#4f81bd" %)** **(% _mstmutation="1" style="color:red" %)**CN470**(%%): LoRaWAN CN470 band 760 760 761 - 762 - 763 763 = 9. Packing Info = 764 764 765 765 ... ... @@ -772,15 +772,11 @@ 772 772 * Device Size: 10 x 10 x 3.5 mm 773 773 * Device Weight: 120.5g 774 774 775 - 776 - 777 777 = 10. Reference material = 778 778 779 779 780 780 * [[Datasheet, photos, decoder, firmware>>https://www.dropbox.com/sh/una19zsni308dme/AACOKp6J2RF5TMlKWT5zU3RTa?dl=0]] 781 781 782 - 783 - 784 784 = 11. FCC Warning = 785 785 786 786