Changes for page LHT65N-PIR Temperature/Humidity/PIR Motion Sensor User Manual
Last modified by Xiaoling on 2025/04/24 10:00
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Xiaoling1 +XWiki.Edwin - Content
-
... ... @@ -45,6 +45,7 @@ 45 45 * External PIR Sensor 46 46 * Tri-color LED to indicate working status(% style="display:none" %) 47 47 48 + 48 48 == 1.3 Specification == 49 49 50 50 ... ... @@ -62,14 +62,13 @@ 62 62 * Long Term Drift: < 0.02 °C/yr 63 63 * Operating Range: 0 ~~ 96 %RH 64 64 65 -(% class="mark" style="color:#037691" %)**External PIR Sensor:**66 +(% style="color:#037691" %)**External PIR Sensor:** 66 66 67 -* (% class="mark" %)Base on BH1750 Illumination Sensor 68 -* (% class="mark" %)Cable Length : 50cm 69 -* (% class="mark" %)Resolution: 1 lx 70 -* (% class="mark" %)Range: 0-65535 lx 71 -* (% class="mark" %)Operating Range: -40 °C ~~ 85 °C 68 +* Base on RDB223 Sensor 69 +* Cable Length : 1 meter 70 +* Stable detect distance : 0~~3 meter 72 72 72 + 73 73 = 2. Connect LHT65N-PIR to IoT Server = 74 74 75 75 == 2.1 How does LHT65N-PIR work? == ... ... @@ -106,6 +106,7 @@ 106 106 ))) 107 107 |(% style="background-color:#f2f2f2; width:167px" %)Fast press ACT 5 times.|(% style="background-color:#f2f2f2; width:117px" %)Deactivate Device|(% style="background-color:#f2f2f2; width:225px" %)(% style="color:red" %)**Red led**(%%) will solid on for 5 seconds. Means LHT65N is in Deep Sleep Mode. 108 108 109 + 109 109 == 2.3 Example to join LoRaWAN network == 110 110 111 111 ... ... @@ -180,6 +180,7 @@ 180 180 181 181 [[image:image-20230508151932-1.png]] 182 182 184 + 183 183 **Sensor Model**: For LHT65N-PIR, this value is 0x1A 184 184 185 185 **Firmware Version**: 0x0100, Means: v1.0.0 version ... ... @@ -275,6 +275,7 @@ 275 275 * The 8^^th^^ byte: Alarm Bit (if this uplink is from periodically or movement) 276 276 * The 9^^th^^ ~~ 11^^st^^ byte: Movement Detect Count. 277 277 280 + 278 278 === 2.5.1 Decoder in TTN V3 === 279 279 280 280 ... ... @@ -313,6 +313,7 @@ 313 313 * BAT status=(0xcba4>>14)&0xFF=11(B),very good 314 314 * Battery Voltage =0xCBF6&0x3FFF=0x0BA4=2980mV 315 315 319 + 316 316 === 2.5.3 Built-in Temperature === 317 317 318 318 [[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220522235639-2.png||_mstalt="431756" height="138" width="722"]] ... ... @@ -323,6 +323,7 @@ 323 323 324 324 * Temperature: (0xF5C6-65536)/100=-26.18℃ 325 325 330 + 326 326 === 2.5.4 Built-in Humidity === 327 327 328 328 [[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220522235639-4.png||_mstalt="432484" height="138" width="722"]] ... ... @@ -329,10 +329,12 @@ 329 329 330 330 * Humidity: 0x025C/10=60.4% 331 331 337 + 332 332 === 2.5.5 Ext value === 333 333 334 334 ==== 2.5.5.1 Ext~=0x0E, PIR Sensor ==== 335 335 342 + 336 336 [[image:ext=14.png||alt="image-20221224161634-2.png"]] 337 337 338 338 ... ... @@ -409,11 +409,12 @@ 409 409 410 410 In a normal working state: 411 411 412 -* For each uplink, the **(% style="color:blue" %)BLUE LED**(%%) or (% style="color:red" %)**RED LED**(%%) will blink once.419 +* For each uplink, the (% style="color:blue" %)**BLUE LED**(%%) or (% style="color:red" %)**RED LED**(%%) will blink once. 413 413 (% style="color:blue" %)**BLUE LED**(%%) when external sensor is connected. 414 414 * (% style="color:red" %)**RED LED**(%%) when external sensor is not connected 415 415 * For each success downlink, the (% style="color:purple" %)**PURPLE LED**(%%) will blink once 416 416 424 + 417 417 == 2.8 installation == 418 418 419 419 ... ... @@ -425,14 +425,20 @@ 425 425 426 426 [[image:image-20230411135341-1.png||height="450" width="456"]] 427 427 436 + 428 428 (% style="color:red" %)**Notice: PIR can only detect motion activity, not to use to detect static people case.** 429 429 430 430 * 1. PIR Motion Detector should not be installed near the Air conditioner places where with cold wind or hot wind flow, because PIR motion detector is sensitive with the temperature changes of the environment. Environment changes quickly will cause a false alarm. 440 + 431 431 * 2. PIR should not be installed facing the glass window, facing glass window will be interfered by the outside sunlight and moving objects (people or vehicle). The infrared energy can penetrate the glass window. 442 + 432 432 * 3. PIR should not be installed facing the moving objects or background changing objects, movement object will cause airflow change, it may cause false alarm. 444 + 433 433 * 4. Between the detection range of PIR Motion detector, there is should be less objects. Many objects may reduce the sensitive of detection range. 446 + 434 434 * 5. Do not install more than one (2 or above) Wireless PIR in the same detection space (like at the same room). 435 435 449 + 436 436 = 3. Sensors and Accessories = 437 437 438 438 == 3.1 E2 Extension Cable == ... ... @@ -461,8 +461,10 @@ 461 461 LHT65N-PIR supports below configure method: 462 462 463 463 * AT Command via UART Connection : See [[FAQ>>||anchor="H7.FAQ"]]. 478 + 464 464 * LoRaWAN Downlink. Instruction for different platforms: See [[IoT LoRaWAN Server>>url:http://wiki.dragino.com/xwiki/bin/view/Main/]] section. 465 465 481 + 466 466 == 4.2 General Commands == 467 467 468 468 ... ... @@ -504,6 +504,7 @@ 504 504 505 505 * **Example 2**: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 506 506 523 + 507 507 === 4.3.2 Get Device Status === 508 508 509 509 ... ... @@ -558,6 +558,7 @@ 558 558 559 559 * There is no downlink command to set to Sleep mode. 560 560 578 + 561 561 === 4.3.5 Set UOA (Uplink on Activity) === 562 562 563 563 ... ... @@ -599,6 +599,7 @@ 599 599 * (Recommanded way) OTA firmware update via wireless: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/]] 600 600 * Update through UART TTL interface. **[[Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware]]**. 601 601 620 + 602 602 = 7. FAQ = 603 603 604 604 == 7.1 How to use AT Command? == ... ... @@ -724,6 +724,7 @@ 724 724 * (% style="color:#4f81bd" %)** **(% _mstmutation="1" style="color:red" %)**IN865**(%%): LoRaWAN IN865 band 725 725 * (% style="color:#4f81bd" %)** **(% _mstmutation="1" style="color:red" %)**CN470**(%%): LoRaWAN CN470 band 726 726 746 + 727 727 = 9. Packing Info = 728 728 729 729 ... ... @@ -736,11 +736,13 @@ 736 736 * Device Size: 10 x 10 x 3.5 mm 737 737 * Device Weight: 120.5g 738 738 759 + 739 739 = 10. Reference material = 740 740 741 741 742 742 * [[Datasheet, photos, decoder, firmware>>https://www.dropbox.com/sh/una19zsni308dme/AACOKp6J2RF5TMlKWT5zU3RTa?dl=0]] 743 743 765 + 744 744 = 11. FCC Warning = 745 745 746 746