Changes for page LHT65N-PIR Temperature/Humidity/PIR Motion Sensor User Manual
Last modified by Xiaoling on 2025/06/10 09:17
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Xiaoling1 +XWiki.Saxer - Content
-
... ... @@ -43,8 +43,10 @@ 43 43 * Built-in 2400mAh battery for up to 5 years of use. 44 44 * Built-in Temperature & Humidity sensor 45 45 * External PIR Sensor 46 -* Tri-color LED to indicate working status (% style="display:none" %)46 +* Tri-color LED to indicate working status 47 47 48 +(% style="display:none" %) 49 + 48 48 == 1.3 Specification == 49 49 50 50 ... ... @@ -62,13 +62,11 @@ 62 62 * Long Term Drift: < 0.02 °C/yr 63 63 * Operating Range: 0 ~~ 96 %RH 64 64 65 -(% class="mark" style="color:#037691" %)**External PIR Sensor:**67 +(% style="color:#037691" %)**External PIR Sensor:** 66 66 67 -* (% class="mark" %)Base on BH1750 Illumination Sensor 68 -* (% class="mark" %)Cable Length : 50cm 69 -* (% class="mark" %)Resolution: 1 lx 70 -* (% class="mark" %)Range: 0-65535 lx 71 -* (% class="mark" %)Operating Range: -40 °C ~~ 85 °C 69 +* Base on RDB223 Sensor 70 +* Cable Length : 1 meter 71 +* Stable detect distance : 0~~3 meter 72 72 73 73 = 2. Connect LHT65N-PIR to IoT Server = 74 74 ... ... @@ -98,13 +98,13 @@ 98 98 (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 99 99 |=(% style="width: 167px;background-color:#D9E2F3;color:#0070C0" %)**Behavior on ACT**|=(% style="width: 117px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 225px;background-color:#D9E2F3;color:#0070C0" %)**Action** 100 100 |(% style="background-color:#f2f2f2; width:167px" %)Pressing ACT between 1s < time < 3s|(% style="background-color:#f2f2f2; width:117px" %)Test uplink status|(% style="background-color:#f2f2f2; width:225px" %)((( 101 -If LHT65N is already Joined to rhe LoRaWAN network, LHT65N will send an uplink packet, if LHT65N has external sensor connected,(% style="color:blue" %)**Blue led** (%%)will blink once. If LHT65N has not external sensor, (% style="color:red" %)**Red led**(%%) will blink once. 101 +If LHT65N-PIR is already Joined to rhe LoRaWAN network, LHT65N-PIR will send an uplink packet, if LHT65N-PIR has external sensor connected,(% style="color:blue" %)**Blue led** (%%)will blink once. If LHT65N-PIR has not external sensor, (% style="color:red" %)**Red led**(%%) will blink once. 102 102 ))) 103 103 |(% style="background-color:#f2f2f2; width:167px" %)Pressing ACT for more than 3s|(% style="background-color:#f2f2f2; width:117px" %)Active Device|(% style="background-color:#f2f2f2; width:225px" %)((( 104 -(% style="background-color:#f2f2f2; color:green" %)**Green led**(%%) will fast blink 5 times, LHT65N will enter working mode and start to JOIN LoRaWAN network. 104 +(% style="background-color:#f2f2f2; color:green" %)**Green led**(%%) will fast blink 5 times, LHT65N-PIR will enter working mode and start to JOIN LoRaWAN network. 105 105 (% style="background-color:#f2f2f2; color:green" %)**Green led**(%%) will solidly turn on for 5 seconds after join in network. 106 106 ))) 107 -|(% style="background-color:#f2f2f2; width:167px" %)Fast press ACT 5 times.|(% style="background-color:#f2f2f2; width:117px" %)Deactivate Device|(% style="background-color:#f2f2f2; width:225px" %)(% style="color:red" %)**Red led**(%%) will solid on for 5 seconds. Means LHT65N is in Deep Sleep Mode. 107 +|(% style="background-color:#f2f2f2; width:167px" %)Fast press ACT 5 times.|(% style="background-color:#f2f2f2; width:117px" %)Deactivate Device|(% style="background-color:#f2f2f2; width:225px" %)(% style="color:red" %)**Red led**(%%) will solid on for 5 seconds. Means LHT65N-PIR is in Deep Sleep Mode. 108 108 109 109 == 2.3 Example to join LoRaWAN network == 110 110 ... ... @@ -180,12 +180,13 @@ 180 180 181 181 [[image:image-20230508151932-1.png]] 182 182 183 -**Sensor Model**: For LHT65N-PIR, this value is 0x1A 184 184 185 - **FirmwareVersion**:0x0100,Means:v1.0.0 version184 +(% style="color:blue" %)**Sensor Model**(%%): For LHT65N-PIR, this value is 0x1A 186 186 187 -**Fre quencyBand**:186 +(% style="color:blue" %)**Firmware Version**(%%): 0x0100, Means: v1.0.0 version 188 188 188 +(% style="color:blue" %)**Frequency Band**: 189 + 189 189 *0x01: EU868 190 190 191 191 *0x02: US915 ... ... @@ -214,15 +214,15 @@ 214 214 215 215 *0x0e: MA869 216 216 217 -**Sub-Band**: 218 +(% style="color:blue" %)**Sub-Band**: 218 218 219 -AU915 and US915:value 0x00 ~~ 0x08 220 +AU915 and US915: value 0x00 ~~ 0x08 220 220 221 221 CN470: value 0x0B ~~ 0x0C 222 222 223 223 Other Bands: Always 0x00 224 224 225 -**Battery Info**: 226 +(% style="color:blue" %)**Battery Info**: 226 226 227 227 Check the battery voltage. 228 228 ... ... @@ -239,21 +239,21 @@ 239 239 After each uplink, the (% style="color:blue" %)**BLUE LED**(%%) will blink once. 240 240 241 241 (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:390px" %) 242 -|=(% style="width: 60px;background-color:#D9E2F3" %)((( 243 +|=(% style="width: 60px;background-color:#D9E2F3;color:#0070C0" %)((( 243 243 **Size(bytes)** 244 -)))|=(% style="width: 30px;background-color:#D9E2F3" %)((( 245 +)))|=(% style="width: 30px;background-color:#D9E2F3;color:#0070C0" %)((( 245 245 **2** 246 -)))|=(% style="width: 100px;background-color:#D9E2F3" %)((( 247 +)))|=(% style="width: 100px;background-color:#D9E2F3;color:#0070C0" %)((( 247 247 **2** 248 -)))|=(% style="width: 100px;background-color:#D9E2F3" %)((( 249 +)))|=(% style="width: 100px;background-color:#D9E2F3;color:#0070C0" %)((( 249 249 **2** 250 -)))|=(% style="width: 50px;background-color:#D9E2F3" %)((( 251 +)))|=(% style="width: 50px;background-color:#D9E2F3;color:#0070C0" %)((( 251 251 **1** 252 -)))|=(% style="width: 50px;background-color:#D9E2F3" %)((( 253 +)))|=(% style="width: 50px;background-color:#D9E2F3;color:#0070C0" %)((( 253 253 **4** 254 254 ))) 255 255 |(% style="width:97px" %)((( 256 - **Value**257 +Value 257 257 )))|(% style="width:39px" %)((( 258 258 [[BAT>>||anchor="H2.5.2BAT-BatteryInfo"]] 259 259 )))|(% style="width:100px" %)((( ... ... @@ -296,7 +296,7 @@ 296 296 **Bit(bit)** 297 297 )))|=(% style="width: 253px;background-color:#D9E2F3;color:#0070C0" %)[15:14]|=(% style="width: 155px;background-color:#D9E2F3;color:#0070C0" %)[13:0] 298 298 |(% style="width:66px" %)((( 299 - **Value**300 +Value 300 300 )))|(% style="width:250px" %)((( 301 301 BAT Status 302 302 00(b): Ultra Low ( BAT <= 2.50v) ... ... @@ -315,6 +315,7 @@ 315 315 316 316 === 2.5.3 Built-in Temperature === 317 317 319 + 318 318 [[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220522235639-2.png||_mstalt="431756" height="138" width="722"]] 319 319 320 320 * Temperature: 0x0ABB/100=27.47℃ ... ... @@ -325,6 +325,7 @@ 325 325 326 326 === 2.5.4 Built-in Humidity === 327 327 330 + 328 328 [[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220522235639-4.png||_mstalt="432484" height="138" width="722"]] 329 329 330 330 * Humidity: 0x025C/10=60.4% ... ... @@ -333,6 +333,7 @@ 333 333 334 334 ==== 2.5.5.1 Ext~=0x0E, PIR Sensor ==== 335 335 339 + 336 336 [[image:ext=14.png||alt="image-20221224161634-2.png"]] 337 337 338 338 ... ... @@ -344,11 +344,11 @@ 344 344 Bit0 of byte 8th shows if this uplink is generate by PIR activity. 345 345 346 346 (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:393px" %) 347 -|=(% style="width: 10 6px; background-color:rgb(217, 226, 243);rgb(0, 112, 192);" %)(((351 +|=(% style="width: 107px; background-color:#D9E2F3;color:#0070C0" %)((( 348 348 **The 8^^th^^ byte** 349 -)))|=(% style="width: 7 1px; background-color:rgb(217, 226, 243);rgb(0, 112, 192);" %)(((353 +)))|=(% style="width: 73px; background-color:#D9E2F3;color:#0070C0" %)((( 350 350 **Bit 1~~7** 351 -)))|=(% style="width: 21 1px; background-color:rgb(217, 226, 243);rgb(0, 112, 192);" %)(((355 +)))|=(% style="width: 213px; background-color:#D9E2F3;color:#0070C0" %)((( 352 352 **Bit 0** 353 353 ))) 354 354 |(% style="width:106px" %)((( ... ... @@ -399,7 +399,6 @@ 399 399 [[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20221224161957-6.png||height="306" width="852"]] 400 400 401 401 402 - 403 403 == 2.7 LED Indicator == 404 404 405 405 ... ... @@ -409,10 +409,10 @@ 409 409 410 410 In a normal working state: 411 411 412 -* For each uplink, the **(% style="color:blue" %)BLUE LED**(%%) or (% style="color:red" %)**RED LED**(%%) will blink once.415 +* For each uplink, the (% style="color:blue" %)**BLUE LED**(%%) or (% style="color:red" %)**RED LED**(%%) will blink once. 413 413 (% style="color:blue" %)**BLUE LED**(%%) when external sensor is connected. 414 414 * (% style="color:red" %)**RED LED**(%%) when external sensor is not connected 415 -* For each success downlink, the (% style="color:purple" %)**PURPLE LED** will blink once 418 +* For each success downlink, the (% style="color:purple" %)**PURPLE LED**(%%) will blink once 416 416 417 417 == 2.8 installation == 418 418 ... ... @@ -425,12 +425,17 @@ 425 425 426 426 [[image:image-20230411135341-1.png||height="450" width="456"]] 427 427 431 + 428 428 (% style="color:red" %)**Notice: PIR can only detect motion activity, not to use to detect static people case.** 429 429 430 430 * 1. PIR Motion Detector should not be installed near the Air conditioner places where with cold wind or hot wind flow, because PIR motion detector is sensitive with the temperature changes of the environment. Environment changes quickly will cause a false alarm. 435 + 431 431 * 2. PIR should not be installed facing the glass window, facing glass window will be interfered by the outside sunlight and moving objects (people or vehicle). The infrared energy can penetrate the glass window. 437 + 432 432 * 3. PIR should not be installed facing the moving objects or background changing objects, movement object will cause airflow change, it may cause false alarm. 439 + 433 433 * 4. Between the detection range of PIR Motion detector, there is should be less objects. Many objects may reduce the sensitive of detection range. 441 + 434 434 * 5. Do not install more than one (2 or above) Wireless PIR in the same detection space (like at the same room). 435 435 436 436 = 3. Sensors and Accessories = ... ... @@ -461,6 +461,7 @@ 461 461 LHT65N-PIR supports below configure method: 462 462 463 463 * AT Command via UART Connection : See [[FAQ>>||anchor="H7.FAQ"]]. 472 + 464 464 * LoRaWAN Downlink. Instruction for different platforms: See [[IoT LoRaWAN Server>>url:http://wiki.dragino.com/xwiki/bin/view/Main/]] section. 465 465 466 466 == 4.2 General Commands == ... ... @@ -563,6 +563,8 @@ 563 563 564 564 Feature: Enable / Disable Uplink on Activity 565 565 575 +(% style="color:#4f81bd" %)**AT Command: ** 576 + 566 566 * **AT+UOA=0** : Disable UoA 567 567 568 568 * **AT+UOA=1,2** : Enable UoA , Calm Down Time: 2 minutes. If device already send a uplink on activity, it will not send another uplink on activiy in 2 minutes, even detect activity. ... ... @@ -569,12 +569,17 @@ 569 569 570 570 (% style="color:red" %)**Notice: Calm Down time range is 1 ~~ 65535 minutes. If user set Calm Down time to low value, such as 1 minute, the sensor might send uplink very frequenctly and battery drain fast.** 571 571 572 -(% style="color:#4f81bd" %)**AT Command: AT+UOA** 573 573 584 +(% style="color:#4f81bd" %)**Downlink Command:** 574 574 575 - (% style="color:#4f81bd"%)**DownlinkCommand:**(%class="mark"%)**xxxxxxx**586 +Format: Command Code (0xA1) followed by 1 byte or 3 bytes. 576 576 588 +When followed by 3 bytes, the first byte is 01, and the second and third bytes are Calm Down Time. 577 577 590 +* **A1 00 ==> AT+UOA=0 ** 591 +* **A1 01 00 02 ==> AT+UOA=1,2** 592 + 593 + 578 578 = 5. Battery & Power Consumption = 579 579 580 580 ... ... @@ -731,11 +731,7 @@ 731 731 732 732 * LHT65N-PIR Temperature/Humidity/PIR Sensor x 1 733 733 734 -**Dimension and weight**: 735 735 736 -* Device Size: 10 x 10 x 3.5 mm 737 -* Device Weight: 120.5g 738 - 739 739 = 10. Reference material = 740 740 741 741