Last modified by Xiaoling on 2025/06/10 09:17

From version 44.3
edited by Xiaoling
on 2023/05/16 17:18
Change comment: There is no comment for this version
To version 37.10
edited by Xiaoling
on 2023/04/27 10:37
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,9 +1,14 @@
1 1  (% style="text-align:center" %)
2 -[[image:LHT65N-PIR1.jpg||alt="image-20221206143242-2.png" height="484" width="485"]]
2 +[[image:image-20221206143242-2.png||height="602" width="551"]]
3 3  
4 4  
5 5  
6 6  
7 +
8 +
9 +
10 +
11 +
7 7  **Table of Contents:**
8 8  
9 9  {{toc/}}
... ... @@ -13,6 +13,9 @@
13 13  
14 14  
15 15  
21 +
22 +
23 +
16 16  = 1. Introduction =
17 17  
18 18  == 1.1 What is LHT65N-PIR Temperature,Humidity & PIR Sensor ==
... ... @@ -127,7 +127,7 @@
127 127  
128 128  Each LHT65N-PIR is shipped with a sticker with its device EUI, APP Key and APP EUI as below:
129 129  
130 -[[image:image-20230426083533-1.png||height="286" width="616"]]
138 +[[image:image-20230426083533-1.png]]
131 131  
132 132  
133 133  User can enter these keys in the LoRaWAN Server portal. Below is TTN V3 screenshot:
... ... @@ -178,7 +178,7 @@
178 178  
179 179  Example parse in TTNv3
180 180  
181 -[[image:image-20230508151932-1.png]]
189 +[[image:1675144504430-490.png]]
182 182  
183 183  **Sensor Model**: For LHT65N-PIR, this value is 0x1A
184 184  
... ... @@ -331,9 +331,9 @@
331 331  
332 332  === 2.5.5 Ext value ===
333 333  
334 -==== 2.5.5.1 Ext~=0x0E, PIR Sensor ====
342 +==== 2.5.5.1 Ext~=0x0A, PIR Sensor ====
335 335  
336 -[[image:ext=14.png||alt="image-20221224161634-2.png"]]
344 +[[image:image-20221224161634-2.png||height="138" width="851"]]
337 337  
338 338  
339 339  ==== 2.5.5.2 Ext Value ====
... ... @@ -358,6 +358,7 @@
358 358  )))|(% style="width:211px" %)(((
359 359  (((
360 360  0: Normal Uplink
369 +
361 361  1: Uplink by activity detected
362 362  )))
363 363  )))
... ... @@ -409,10 +409,10 @@
409 409  
410 410  In a normal working state:
411 411  
412 -* For each uplink, the **(% style="color:blue" %)BLUE LED**(%%) or (% style="color:red" %)**RED LED**(%%) will blink once.
413 -(% style="color:blue" %)**BLUE LED**(%%) when external sensor is connected.
414 -* (% style="color:red" %)**RED LED**(%%) when external sensor is not connected
415 -* For each success downlink, the (% style="color:purple" %)**PURPLE LED** will blink once
421 +* For each uplink, the BLUE LED or RED LED will blink once.
422 +BLUE LED when external sensor is connected.
423 +* RED LED when external sensor is not connected
424 +* For each success downlink, the PURPLE LED will blink once
416 416  
417 417  == 2.8 installation ==
418 418  
... ... @@ -441,7 +441,7 @@
441 441  [[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220619092222-1.png||_mstalt="429533" height="182" width="188"]][[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220619092313-2.png||_mstalt="430222" height="182" width="173"]]
442 442  
443 443  
444 -**1m long breakout cable for LHT65N-PIR. Features:**
453 +**1m long breakout cable for LHT65N-E5. Features:**
445 445  
446 446  * (((
447 447  Use for AT Command
... ... @@ -614,11 +614,12 @@
614 614  [[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@1655802313617-381.png||_mstalt="293917"]]
615 615  
616 616  
617 -In PC, User needs to set serial tool(such as [[**putty**>>https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to (% style="color:green" %)**9600** (%%)to access to access serial console for LHT65N-PIR. The AT commands are disable by default and need to enter password (default:(% style="color:green" %)**123456**(% style="color:red" %))(%%) to active it. Timeout to input AT Command is 5 min, after 5-minute, user need to input password again. User can use AT+DISAT command to disable AT command before timeout.
626 +In PC, User needs to set serial tool(such as [[**putty**>>https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to (% style="color:green" %)**9600** (%%)to access to access serial console for LHT65N-E5. The AT commands are disable by default and need to enter password (default:(% style="color:green" %)**123456**(% style="color:red" %))(%%) to active it. Timeout to input AT Command is 5 min, after 5-minute, user need to input password again. User can use AT+DISAT command to disable AT command before timeout.
618 618  
619 619  [[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615154519-3.png||_mstalt="431925" height="672" width="807"]]
620 620  
621 621  
631 +
622 622  == 7.2 Where to use AT commands and Downlink commands ==
623 623  
624 624  
LHT65N-PIR1.jpg
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ellie
Size
... ... @@ -1,1 +1,0 @@
1 -47.3 KB
Content
ext=14.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ellie
Size
... ... @@ -1,1 +1,0 @@
1 -30.5 KB
Content
image-20230508151932-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.kai
Size
... ... @@ -1,1 +1,0 @@
1 -36.0 KB
Content