From version < 37.7 >
edited by Xiaoling
on 2023/04/27 09:28
To version < 37.4 >
edited by Xiaoling
on 2023/04/27 08:58
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -145,21 +145,21 @@
145 145  [[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220522232916-3.png||_mstalt="430495"]]
146 146  
147 147  
148 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N-E5%20LoRaWAN%20Temperature_Humidity%20%26%20Illuminance%20Sensor%20User%20Manual/WebHome/image-20220522232932-4.png?rev=1.1||alt="image-20220522232932-4.png"]]
148 +[[image:image-20220522232932-4.png||_mstalt="430157"]]
149 149  
150 150  
151 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N-E5%20LoRaWAN%20Temperature_Humidity%20%26%20Illuminance%20Sensor%20User%20Manual/WebHome/image-20220522232954-5.png?rev=1.1||alt="image-20220522232954-5.png"]]
151 +[[image:image-20220522232954-5.png||_mstalt="431847"]]
152 152  
153 153  
154 154  (% style="color:red" %)**Note: LHT65N-PIR use same payload decoder as LHT65.**
155 155  
156 156  
157 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N-E5%20LoRaWAN%20Temperature_Humidity%20%26%20Illuminance%20Sensor%20User%20Manual/WebHome/image-20220522233026-6.png?rev=1.1||alt="image-20220522233026-6.png"]]
157 +[[image:image-20220522233026-6.png||_mstalt="429403"]]
158 158  
159 159  
160 160  **Input APP EUI,  APP KEY and DEV EUI:**
161 161  
162 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N-E5%20LoRaWAN%20Temperature_Humidity%20%26%20Illuminance%20Sensor%20User%20Manual/WebHome/image-20220522233118-7.png?rev=1.1||alt="image-20220522233118-7.png"]]
162 +[[image:image-20220522233118-7.png||_mstalt="430430"]]
163 163  
164 164  
165 165  === 2.3.2 Step 2: Activate LHT65N-PIR by pressing the ACT button for more than 5 seconds. ===
... ... @@ -168,7 +168,7 @@
168 168  Use ACT button to activate LHT65N-PIR and it will auto-join to the TTN V3 network. After join success, it will start to upload sensor data to TTN V3 and user can see in the panel.
169 169  
170 170  
171 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N-E5%20LoRaWAN%20Temperature_Humidity%20%26%20Illuminance%20Sensor%20User%20Manual/WebHome/image-20220522233300-8.png?rev=1.1||alt="image-20220522233300-8.png"]]
171 +[[image:image-20220522233300-8.png||_mstalt="428389" height="219" width="722"]]
172 172  
173 173  
174 174  == 2.4 Uplink Payload~-~-Device Status, (Fport~=5) ==
... ... @@ -262,19 +262,19 @@
262 262  |(% style="width:97px" %)(((
263 263  **Value**
264 264  )))|(% style="width:39px" %)(((
265 -[[BAT>>||anchor="H2.5.2BAT-BatteryInfo"]]
265 +[[BAT>>||anchor="H2.4.2BAT-BatteryInfo"]]
266 266  )))|(% style="width:100px" %)(((
267 267  (((
268 -[[Built-In Temperature>>||anchor="H2.5.3Built-inTemperature"]]
268 +[[Built-In Temperature>>||anchor="H2.4.3Built-inTemperature"]]
269 269  )))
270 270  )))|(% style="width:77px" %)(((
271 271  (((
272 -[[Built-in Humidity>>||anchor="H2.5.4Built-inHumidity"]]
272 +[[Built-in Humidity>>||anchor="H2.4.4Built-inHumidity"]]
273 273  )))
274 274  )))|(% style="width:47px" %)(((
275 275  Ext #
276 276  )))|(% style="width:51px" %)(((
277 -[[Ext value>>||anchor="H2.5.5Extvalue"]]
277 +[[Ext value>>||anchor="H2.5.5.2ExtValue"]]
278 278  )))
279 279  
280 280  * The First 6 bytes: has fix meanings for every LHT65N-PIR.
... ... @@ -298,19 +298,7 @@
298 298  
299 299  These two bytes of BAT include the battery state and the actually voltage
300 300  
301 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:477px" %)
302 -|=(% style="width: 69px; background-color:#D9E2F3;color:#0070C0" %)(((
303 -**Bit(bit)**
304 -)))|=(% style="width: 253px;background-color:#D9E2F3;color:#0070C0" %)[15:14]|=(% style="width: 155px;background-color:#D9E2F3;color:#0070C0" %)[13:0]
305 -|(% style="width:66px" %)(((
306 -**Value**
307 -)))|(% style="width:250px" %)(((
308 -BAT Status
309 -00(b): Ultra Low ( BAT <= 2.50v)
310 -01(b): Low (2.50v <=BAT <= 2.55v)
311 -10(b): OK (2.55v <= BAT <=2.65v)
312 -11(b): Good (BAT >= 2.65v)
313 -)))|(% style="width:152px" %)Actually BAT voltage
301 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220523152839-18.png||_mstalt="457613"]]
314 314  
315 315  
316 316  [[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220522235639-1.png||_mstalt="431392" height="139" width="727"]]
... ... @@ -350,12 +350,12 @@
350 350  
351 351  Bit0 of byte 8th shows if this uplink is generate by PIR activity.
352 352  
353 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:490px" %)
354 -|=(% style="width: 147px;background-color:#D9E2F3;color:#0070C0" %)(((
341 +(% border="1" cellspacing="4" style="background-color:#ffffcc; color:green; width:490px" %)
342 +|=(% style="width: 147px;" %)(((
355 355  **The 8^^th^^ byte**
356 -)))|=(% style="width: 108px;background-color:#D9E2F3;color:#0070C0" %)(((
344 +)))|=(% style="width: 108px;" %)(((
357 357  **Bit 1~~7**
358 -)))|=(% style="width: 228px;background-color:#D9E2F3;color:#0070C0" %)(((
346 +)))|=(% style="width: 228px;" %)(((
359 359  **Bit 0**
360 360  )))
361 361  |(% style="width:147px" %)(((
... ... @@ -370,7 +370,7 @@
370 370  )))
371 371  )))
372 372  
373 -(% style="color:red" %)**Note**:** Uplink by activity is disable by default.**
361 +**Note**: Uplink by activity is disable by default.
374 374  
375 375  
376 376  The 9^^th^^ ~~ 11^^st^^  byte: Movement Detect Count.
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved