Summary

Details

Page properties
Content
... ... @@ -145,21 +145,21 @@
145 145  [[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220522232916-3.png||_mstalt="430495"]]
146 146  
147 147  
148 -[[image:image-20220522232932-4.png||_mstalt="430157"]]
148 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N-E5%20LoRaWAN%20Temperature_Humidity%20%26%20Illuminance%20Sensor%20User%20Manual/WebHome/image-20220522232932-4.png?rev=1.1||alt="image-20220522232932-4.png"]]
149 149  
150 150  
151 -[[image:image-20220522232954-5.png||_mstalt="431847"]]
151 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N-E5%20LoRaWAN%20Temperature_Humidity%20%26%20Illuminance%20Sensor%20User%20Manual/WebHome/image-20220522232954-5.png?rev=1.1||alt="image-20220522232954-5.png"]]
152 152  
153 153  
154 154  (% style="color:red" %)**Note: LHT65N-PIR use same payload decoder as LHT65.**
155 155  
156 156  
157 -[[image:image-20220522233026-6.png||_mstalt="429403"]]
157 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N-E5%20LoRaWAN%20Temperature_Humidity%20%26%20Illuminance%20Sensor%20User%20Manual/WebHome/image-20220522233026-6.png?rev=1.1||alt="image-20220522233026-6.png"]]
158 158  
159 159  
160 160  **Input APP EUI,  APP KEY and DEV EUI:**
161 161  
162 -[[image:image-20220522233118-7.png||_mstalt="430430"]]
162 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N-E5%20LoRaWAN%20Temperature_Humidity%20%26%20Illuminance%20Sensor%20User%20Manual/WebHome/image-20220522233118-7.png?rev=1.1||alt="image-20220522233118-7.png"]]
163 163  
164 164  
165 165  === 2.3.2 Step 2: Activate LHT65N-PIR by pressing the ACT button for more than 5 seconds. ===
... ... @@ -168,7 +168,7 @@
168 168  Use ACT button to activate LHT65N-PIR and it will auto-join to the TTN V3 network. After join success, it will start to upload sensor data to TTN V3 and user can see in the panel.
169 169  
170 170  
171 -[[image:image-20220522233300-8.png||_mstalt="428389" height="219" width="722"]]
171 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N-E5%20LoRaWAN%20Temperature_Humidity%20%26%20Illuminance%20Sensor%20User%20Manual/WebHome/image-20220522233300-8.png?rev=1.1||alt="image-20220522233300-8.png"]]
172 172  
173 173  
174 174  == 2.4 Uplink Payload~-~-Device Status, (Fport~=5) ==
... ... @@ -313,7 +313,6 @@
313 313  )))|(% style="width:152px" %)Actually BAT voltage
314 314  
315 315  
316 -
317 317  [[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220522235639-1.png||_mstalt="431392" height="139" width="727"]]
318 318  
319 319  
... ... @@ -351,19 +351,19 @@
351 351  
352 352  Bit0 of byte 8th shows if this uplink is generate by PIR activity.
353 353  
354 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:490px" %)
355 -|=(% style="width: 147px;background-color:#D9E2F3;color:#0070C0" %)(((
353 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:393px" %)
354 +|=(% style="width: 106px; background-color: rgb(217, 226, 243); color: rgb(0, 112, 192);" %)(((
356 356  **The 8^^th^^ byte**
357 -)))|=(% style="width: 108px;background-color:#D9E2F3;color:#0070C0" %)(((
356 +)))|=(% style="width: 71px; background-color: rgb(217, 226, 243); color: rgb(0, 112, 192);" %)(((
358 358  **Bit 1~~7**
359 -)))|=(% style="width: 228px;background-color:#D9E2F3;color:#0070C0" %)(((
358 +)))|=(% style="width: 211px; background-color: rgb(217, 226, 243); color: rgb(0, 112, 192);" %)(((
360 360  **Bit 0**
361 361  )))
362 -|(% style="width:147px" %)(((
361 +|(% style="width:106px" %)(((
363 363  **Value**
364 -)))|(% style="width:108px" %)(((
363 +)))|(% style="width:71px" %)(((
365 365  Reserve
366 -)))|(% style="width:228px" %)(((
365 +)))|(% style="width:211px" %)(((
367 367  (((
368 368  0: Normal Uplink
369 369  
... ... @@ -371,7 +371,7 @@
371 371  )))
372 372  )))
373 373  
374 -**Note**: Uplink by activity is disable by default.
373 +(% style="color:red" %)**Note**:** Uplink by activity is disable by default.**
375 375  
376 376  
377 377  The 9^^th^^ ~~ 11^^st^^  byte: Movement Detect Count.
... ... @@ -468,7 +468,7 @@
468 468  
469 469  LHT65N-PIR supports below configure method:
470 470  
471 -* AT Command via UART Connection : See [[FAQ>>path:#H7.FAQ]].
470 +* AT Command via UART Connection : See [[FAQ>>||anchor="H7.FAQ"]].
472 472  * LoRaWAN Downlink.  Instruction for different platforms: See [[IoT LoRaWAN Server>>url:http://wiki.dragino.com/xwiki/bin/view/Main/]] section.
473 473  
474 474  == 4.2 General Commands ==
... ... @@ -498,9 +498,11 @@
498 498  
499 499  (% style="color:#4f81bd" %)**AT Command: AT+TDC**
500 500  
501 -[[image:image-20220523150701-2.png||_mstalt="427453"]]
500 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:501px" %)
501 +|(% style="background-color:#d9e2f3; color:#0070c0; width:155px" %)**Command Example**|(% style="background-color:#d9e2f3; color:#0070c0; width:166px" %)**Function**|(% style="background-color:#d9e2f3; color:#0070c0; width:180px" %)**Response**
502 +|(% style="width:155px" %)AT+TDC?|(% style="width:162px" %)Show current transmit Interval|(% style="width:177px" %)30000 OK the interval is 30000ms = 30s
503 +|(% style="width:155px" %)AT+TDC=60000|(% style="width:162px" %)Set Transmit Interval|(% style="width:177px" %)OK Set transmit interval to 60000ms = 60 seconds
502 502  
503 -
504 504  (% style="color:#4f81bd" %)**Downlink Payload: 0x01**
505 505  
506 506  Format: Command Code (0x01) followed by 3 bytes time value.
... ... @@ -526,26 +526,24 @@
526 526  Feature: Set device password, max 9 digits
527 527  
528 528  
529 -(% style="color:#4f81bd" %)**AT Command: AT+EXT**
530 +(% style="color:#4f81bd" %)**AT Command: AT+PWORD**
530 530  
531 -(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %)
532 -|Command Example|Function|Response
533 -|AT+EXT=?|Get or Set external sensor model|(((
534 -5
535 535  
536 -OK
533 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:372px" %)
534 +|(% style="background-color:#d9e2f3; color:#0070c0; width:155px" %)**Command Example**|(% style="background-color:#d9e2f3; color:#0070c0; width:128px" %)**Function**|(% style="background-color:#d9e2f3; color:#0070c0; width:89px" %)**Response**
535 +|(% style="width:155px" %)AT+PWORD=?|(% style="width:124px" %)Show password|(% style="width:86px" %)(((
536 +123456
537 +
538 +OK
537 537  )))
538 -|AT+EXT=5|(% colspan="2" %)Set external sensor mode to 5
540 +|(% style="width:155px" %)AT+PWORD=999999|(% style="width:124px" %)Set password|(% style="width:86px" %)OK
539 539  
540 -(% style="color:#4f81bd" %)**Downlink Command:0xA2**
542 +(% style="color:#4f81bd" %)**Downlink Command:**
541 541  
544 +No downlink command for this feature.
542 542  
543 -Total bytes: 2 bytes
544 544  
545 -**Example:**
546 546  
547 -* 0xA205: Set external sensor type to E5
548 -
549 549  === 4.3.4 Set to sleep mode ===
550 550  
551 551  
... ... @@ -552,6 +552,7 @@
552 552  Feature: Set device to sleep mode
553 553  
554 554  * **AT+Sleep=0**  : Normal working mode, device will sleep and use lower power when there is no LoRa message
554 +
555 555  * **AT+Sleep=1** :  Device is in deep sleep mode, no LoRa activation happen, used for storage or shipping.
556 556  
557 557  (% style="color:#4f81bd" %)**AT Command: AT+SLEEP**