Changes for page LHT65N-PIR Temperature/Humidity/PIR Motion Sensor User Manual
Last modified by Xiaoling on 2025/06/10 09:17
From version 37.5
edited by Xiaoling
on 2023/04/27 09:00
on 2023/04/27 09:00
Change comment:
There is no comment for this version
To version 39.1
edited by Ellie Zhang
on 2023/05/06 10:35
on 2023/05/06 10:35
Change comment:
Uploaded new attachment "1FPORT=5.png", version {1}
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Xiaoling1 +XWiki.Ellie - Content
-
... ... @@ -25,6 +25,7 @@ 25 25 26 26 == 1.1 What is LHT65N-PIR Temperature,Humidity & PIR Sensor == 27 27 28 + 28 28 The Dragino (% style="color:blue" %)**LHT65N-PIR Temperature, Humidity & PIR sensor**(%%) is a Long Range LoRaWAN Sensor.It includes a (% style="color:blue" %)**built-in Temperature & Humidity sensor**(%%) and has an (% style="color:blue" %)**external PIR Probe**(%%)**.** LHT65N-PIR can detect environment Temperature & Humdity, it also detects (% style="color:blue" %)**People Activity**(%%) via PIR probe and them send these info to LoRaWAN IoT Server. 29 29 30 30 The LHT65N-PIR allows users to send data and reach extremely long ranges. It provides ultra-long range spread spectrum communication and high interference immunity whilst minimizing current consumption. It targets professional wireless sensor network applications such as irrigation systems, smart metering, smart cities, building automation, and so on. ... ... @@ -35,12 +35,12 @@ 35 35 36 36 LHT65N-PIR is fully compatible with (% style="color:blue" %)**LoRaWAN v1.0.3 Class A protocol**(%%), it can work with a standard LoRaWAN gateway. 37 37 38 - 39 39 **~*~***The actual battery life depends on how often to send data, please see battery analyzer chapter. 40 40 41 41 42 42 == 1.2 Features == 43 43 44 + 44 44 * LoRaWAN v1.0.3 Class A protocol 45 45 * Frequency Bands: CN470/EU433/KR920/US915/EU868/AS923/AU915 46 46 * AT Commands to change parameters ... ... @@ -52,6 +52,8 @@ 52 52 * External PIR Sensor 53 53 * Tri-color LED to indicate working status(% style="display:none" %) 54 54 56 + 57 + 55 55 == 1.3 Specification == 56 56 57 57 ... ... @@ -76,12 +76,14 @@ 76 76 * (% class="mark" %)Resolution: 1 lx 77 77 * (% class="mark" %)Range: 0-65535 lx 78 78 * (% class="mark" %)Operating Range: -40 °C ~~ 85 °C 79 -* 80 80 83 + 84 + 81 81 = 2. Connect LHT65N-PIR to IoT Server = 82 82 83 83 == 2.1 How does LHT65N-PIR work? == 84 84 89 + 85 85 LHT65N-PIR is configured as LoRaWAN OTAA Class A sensor by default. Each LHT65N-PIR is shipped with a worldwide unique set of OTAA keys. To use LHT65N-PIR in a LoRaWAN network, first, we need to put the OTAA keys in LoRaWAN Network Server and then activate LHT65N-PIR. 86 86 87 87 If LHT65N-PIR is within the coverage of this LoRaWAN network. LHT65N-PIR can join the LoRaWAN network automatically. After successfully joining, LHT65N-PIR will start to measure environment temperature, humidity & people activity, and start to transmit sensor data to the LoRaWAN server. The default period for each uplink is 20 minutes. ... ... @@ -89,6 +89,7 @@ 89 89 90 90 == 2.2 How to Activate LHT65N-PIR? == 91 91 97 + 92 92 The LHT65N-PIR has two working modes: 93 93 94 94 * (% style="color:blue" %)**Deep Sleep Mode**(%%): LHT65N-PIR doesn't have any LoRaWAN activation. This mode is used for storage and shipping to save battery life. ... ... @@ -101,7 +101,6 @@ 101 101 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N-E5%20LoRaWAN%20Temperature_Humidity%20%26%20Illuminance%20Sensor%20User%20Manual/WebHome/image-20220515123819-1.png?width=317&height=379&rev=1.1||alt="image-20220515123819-1.png" height="379" width="317"]] 102 102 103 103 104 - 105 105 (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 106 106 |=(% style="width: 167px;background-color:#D9E2F3;color:#0070C0" %)**Behavior on ACT**|=(% style="width: 117px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 225px;background-color:#D9E2F3;color:#0070C0" %)**Action** 107 107 |(% style="background-color:#f2f2f2; width:167px" %)Pressing ACT between 1s < time < 3s|(% style="background-color:#f2f2f2; width:117px" %)Test uplink status|(% style="background-color:#f2f2f2; width:225px" %)((( ... ... @@ -113,6 +113,8 @@ 113 113 ))) 114 114 |(% style="background-color:#f2f2f2; width:167px" %)Fast press ACT 5 times.|(% style="background-color:#f2f2f2; width:117px" %)Deactivate Device|(% style="background-color:#f2f2f2; width:225px" %)(% style="color:red" %)**Red led**(%%) will solid on for 5 seconds. Means LHT65N is in Deep Sleep Mode. 115 115 121 + 122 + 116 116 == 2.3 Example to join LoRaWAN network == 117 117 118 118 ... ... @@ -145,21 +145,21 @@ 145 145 [[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220522232916-3.png||_mstalt="430495"]] 146 146 147 147 148 -[[image:image-20220522232932-4.png|| _mstalt="430157"]]155 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N-E5%20LoRaWAN%20Temperature_Humidity%20%26%20Illuminance%20Sensor%20User%20Manual/WebHome/image-20220522232932-4.png?rev=1.1||alt="image-20220522232932-4.png"]] 149 149 150 150 151 -[[image:image-20220522232954-5.png|| _mstalt="431847"]]158 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N-E5%20LoRaWAN%20Temperature_Humidity%20%26%20Illuminance%20Sensor%20User%20Manual/WebHome/image-20220522232954-5.png?rev=1.1||alt="image-20220522232954-5.png"]] 152 152 153 153 154 154 (% style="color:red" %)**Note: LHT65N-PIR use same payload decoder as LHT65.** 155 155 156 156 157 -[[image:image-20220522233026-6.png|| _mstalt="429403"]]164 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N-E5%20LoRaWAN%20Temperature_Humidity%20%26%20Illuminance%20Sensor%20User%20Manual/WebHome/image-20220522233026-6.png?rev=1.1||alt="image-20220522233026-6.png"]] 158 158 159 159 160 160 **Input APP EUI, APP KEY and DEV EUI:** 161 161 162 -[[image:image-20220522233118-7.png|| _mstalt="430430"]]169 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N-E5%20LoRaWAN%20Temperature_Humidity%20%26%20Illuminance%20Sensor%20User%20Manual/WebHome/image-20220522233118-7.png?rev=1.1||alt="image-20220522233118-7.png"]] 163 163 164 164 165 165 === 2.3.2 Step 2: Activate LHT65N-PIR by pressing the ACT button for more than 5 seconds. === ... ... @@ -168,7 +168,7 @@ 168 168 Use ACT button to activate LHT65N-PIR and it will auto-join to the TTN V3 network. After join success, it will start to upload sensor data to TTN V3 and user can see in the panel. 169 169 170 170 171 -[[image:image-20220522233300-8.png|| _mstalt="428389" height="219" width="722"]]178 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N-E5%20LoRaWAN%20Temperature_Humidity%20%26%20Illuminance%20Sensor%20User%20Manual/WebHome/image-20220522233300-8.png?rev=1.1||alt="image-20220522233300-8.png"]] 172 172 173 173 174 174 == 2.4 Uplink Payload~-~-Device Status, (Fport~=5) == ... ... @@ -282,6 +282,8 @@ 282 282 * The 8^^th^^ byte: Alarm Bit (if this uplink is from periodically or movement) 283 283 * The 9^^th^^ ~~ 11^^st^^ byte: Movement Detect Count. 284 284 292 + 293 + 285 285 === 2.5.1 Decoder in TTN V3 === 286 286 287 287 ... ... @@ -298,9 +298,20 @@ 298 298 299 299 These two bytes of BAT include the battery state and the actually voltage 300 300 301 -[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220523152839-18.png||_mstalt="457613"]] 310 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:477px" %) 311 +|=(% style="width: 69px; background-color:#D9E2F3;color:#0070C0" %)((( 312 +**Bit(bit)** 313 +)))|=(% style="width: 253px;background-color:#D9E2F3;color:#0070C0" %)[15:14]|=(% style="width: 155px;background-color:#D9E2F3;color:#0070C0" %)[13:0] 314 +|(% style="width:66px" %)((( 315 +**Value** 316 +)))|(% style="width:250px" %)((( 317 +BAT Status 318 +00(b): Ultra Low ( BAT <= 2.50v) 319 +01(b): Low (2.50v <=BAT <= 2.55v) 320 +10(b): OK (2.55v <= BAT <=2.65v) 321 +11(b): Good (BAT >= 2.65v) 322 +)))|(% style="width:152px" %)Actually BAT voltage 302 302 303 - 304 304 [[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220522235639-1.png||_mstalt="431392" height="139" width="727"]] 305 305 306 306 ... ... @@ -309,6 +309,8 @@ 309 309 * BAT status=(0xcba4>>14)&0xFF=11(B),very good 310 310 * Battery Voltage =0xCBF6&0x3FFF=0x0BA4=2980mV 311 311 332 + 333 + 312 312 === 2.5.3 Built-in Temperature === 313 313 314 314 [[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220522235639-2.png||_mstalt="431756" height="138" width="722"]] ... ... @@ -319,6 +319,8 @@ 319 319 320 320 * Temperature: (0xF5C6-65536)/100=-26.18℃ 321 321 344 + 345 + 322 322 === 2.5.4 Built-in Humidity === 323 323 324 324 [[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220522235639-4.png||_mstalt="432484" height="138" width="722"]] ... ... @@ -325,6 +325,8 @@ 325 325 326 326 * Humidity: 0x025C/10=60.4% 327 327 352 + 353 + 328 328 === 2.5.5 Ext value === 329 329 330 330 ==== 2.5.5.1 Ext~=0x0A, PIR Sensor ==== ... ... @@ -334,23 +334,24 @@ 334 334 335 335 ==== 2.5.5.2 Ext Value ==== 336 336 363 + 337 337 There are 4 bytes in Ext Value field. 338 338 339 339 Bit0 of byte 8th shows if this uplink is generate by PIR activity. 340 340 341 -(% border="1" cellspacing="4" style="background-color:#fff fcc;color:green;width:490px" %)342 -|=(% style="width: 1 47px;" %)(((368 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:393px" %) 369 +|=(% style="width: 106px; background-color: rgb(217, 226, 243); color: rgb(0, 112, 192);" %)((( 343 343 **The 8^^th^^ byte** 344 -)))|=(% style="width: 1 08px;" %)(((371 +)))|=(% style="width: 71px; background-color: rgb(217, 226, 243); color: rgb(0, 112, 192);" %)((( 345 345 **Bit 1~~7** 346 -)))|=(% style="width: 2 28px;" %)(((373 +)))|=(% style="width: 211px; background-color: rgb(217, 226, 243); color: rgb(0, 112, 192);" %)((( 347 347 **Bit 0** 348 348 ))) 349 -|(% style="width:1 47px" %)(((376 +|(% style="width:106px" %)((( 350 350 **Value** 351 -)))|(% style="width:1 08px" %)(((378 +)))|(% style="width:71px" %)((( 352 352 Reserve 353 -)))|(% style="width:2 28px" %)(((380 +)))|(% style="width:211px" %)((( 354 354 ((( 355 355 0: Normal Uplink 356 356 ... ... @@ -358,9 +358,8 @@ 358 358 ))) 359 359 ))) 360 360 361 -**Note**: 388 +(% style="color:red" %)**Note**:** Uplink by activity is disable by default.** 362 362 363 - 364 364 The 9^^th^^ ~~ 11^^st^^ byte: Movement Detect Count. 365 365 366 366 0x00 E5 09 : Total detect 58633 activity since end node start. ... ... @@ -368,6 +368,7 @@ 368 368 369 369 == 2.6 Show data on Datacake == 370 370 397 + 371 371 Datacake IoT platform provides a human-friendly interface to show the sensor data, once we have sensor data in TTN V3, we can use Datacake to connect to TTN V3 and see the data in Datacake. Below are the steps: 372 372 373 373 (% style="color:blue" %)**Step 1**(%%): Be sure that your device is programmed and properly connected to the LoRaWAN network. ... ... @@ -405,13 +405,16 @@ 405 405 406 406 In a normal working state: 407 407 408 -* For each uplink, the BLUE LED or RED LED will blink once. 409 -BLUE LED when external sensor is connected. 410 -* RED LED when external sensor is not connected 435 +* For each uplink, the **BLUE LED** or **RED LED** will blink once. 436 +**BLUE LED** when external sensor is connected. 437 +* **RED LED** when external sensor is not connected 411 411 * For each success downlink, the PURPLE LED will blink once 412 412 440 + 441 + 413 413 == 2.8 installation == 414 414 444 + 415 415 ~1. Don't install LHT65N-PIR outdoor or place where will get wet. 416 416 417 417 2. Towards the PIR probe to the place where need to monitor activity. Below is the detect beam. ... ... @@ -420,7 +420,7 @@ 420 420 421 421 [[image:image-20230411135341-1.png||height="450" width="456"]] 422 422 423 -**Notice: PIR can only detect motion activity, not to use to detect static people case.** 453 +(% style="color:red" %)**Notice: PIR can only detect motion activity, not to use to detect static people case.** 424 424 425 425 * 1. PIR Motion Detector should not be installed near the Air conditioner places where with cold wind or hot wind flow, because PIR motion detector is sensitive with the temperature changes of the environment. Environment changes quickly will cause a false alarm. 426 426 * 2. PIR should not be installed facing the glass window, facing glass window will be interfered by the outside sunlight and moving objects (people or vehicle). The infrared energy can penetrate the glass window. ... ... @@ -428,6 +428,8 @@ 428 428 * 4. Between the detection range of PIR Motion detector, there is should be less objects. Many objects may reduce the sensitive of detection range. 429 429 * 5. Do not install more than one (2 or above) Wireless PIR in the same detection space (like at the same room). 430 430 461 + 462 + 431 431 = 3. Sensors and Accessories = 432 432 433 433 == 3.1 E2 Extension Cable == ... ... @@ -436,7 +436,7 @@ 436 436 [[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220619092222-1.png||_mstalt="429533" height="182" width="188"]][[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220619092313-2.png||_mstalt="430222" height="182" width="173"]] 437 437 438 438 439 -**1m long breakout cable for LHT65N- E5. Features:**471 +**1m long breakout cable for LHT65N-PIR. Features:** 440 440 441 441 * ((( 442 442 Use for AT Command ... ... @@ -455,9 +455,11 @@ 455 455 456 456 LHT65N-PIR supports below configure method: 457 457 458 -* AT Command via UART Connection : See [[FAQ>> path:#H7.FAQ]].490 +* AT Command via UART Connection : See [[FAQ>>||anchor="H7.FAQ"]]. 459 459 * LoRaWAN Downlink. Instruction for different platforms: See [[IoT LoRaWAN Server>>url:http://wiki.dragino.com/xwiki/bin/view/Main/]] section. 460 460 493 + 494 + 461 461 == 4.2 General Commands == 462 462 463 463 ... ... @@ -482,12 +482,13 @@ 482 482 483 483 Feature: Change LoRaWAN End Node Transmit Interval. 484 484 485 - 486 486 (% style="color:#4f81bd" %)**AT Command: AT+TDC** 487 487 488 -[[image:image-20220523150701-2.png||_mstalt="427453"]] 521 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:501px" %) 522 +|(% style="background-color:#d9e2f3; color:#0070c0; width:155px" %)**Command Example**|(% style="background-color:#d9e2f3; color:#0070c0; width:166px" %)**Function**|(% style="background-color:#d9e2f3; color:#0070c0; width:180px" %)**Response** 523 +|(% style="width:155px" %)AT+TDC?|(% style="width:162px" %)Show current transmit Interval|(% style="width:177px" %)30000 OK the interval is 30000ms = 30s 524 +|(% style="width:155px" %)AT+TDC=60000|(% style="width:162px" %)Set Transmit Interval|(% style="width:177px" %)OK Set transmit interval to 60000ms = 60 seconds 489 489 490 - 491 491 (% style="color:#4f81bd" %)**Downlink Payload: 0x01** 492 492 493 493 Format: Command Code (0x01) followed by 3 bytes time value. ... ... @@ -498,8 +498,11 @@ 498 498 499 499 * **Example 2**: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 500 500 536 + 537 + 501 501 === 4.3.2 Get Device Status === 502 502 540 + 503 503 Send a LoRaWAN downlink to ask device send Alarm settings. 504 504 505 505 * (% style="color:#4f81bd" %)**Downlink Payload**(%%)**: **0x26 01 ... ... @@ -512,27 +512,22 @@ 512 512 513 513 Feature: Set device password, max 9 digits 514 514 553 +(% style="color:#4f81bd" %)**AT Command: AT+PWORD** 515 515 516 -(% style="color:#4f81bd" %)**AT Command: AT+EXT** 555 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:372px" %) 556 +|(% style="background-color:#d9e2f3; color:#0070c0; width:155px" %)**Command Example**|(% style="background-color:#d9e2f3; color:#0070c0; width:128px" %)**Function**|(% style="background-color:#d9e2f3; color:#0070c0; width:89px" %)**Response** 557 +|(% style="width:155px" %)AT+PWORD=?|(% style="width:124px" %)Show password|(% style="width:86px" %)((( 558 +123456 517 517 518 -(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %) 519 -|Command Example|Function|Response 520 -|AT+EXT=?|Get or Set external sensor model|((( 521 -5 522 - 523 -OK 560 +OK 524 524 ))) 525 -|AT+ EXT=5|(%colspan="2" %)Setexternalsensormodeto5562 +|(% style="width:155px" %)AT+PWORD=999999|(% style="width:124px" %)Set password|(% style="width:86px" %)OK 526 526 527 -(% style="color:#4f81bd" %)**Downlink Command: 0xA2**564 +(% style="color:#4f81bd" %)**Downlink Command:** 528 528 566 +No downlink command for this feature. 529 529 530 -Total bytes: 2 bytes 531 531 532 -**Example:** 533 - 534 -* 0xA205: Set external sensor type to E5 535 - 536 536 === 4.3.4 Set to sleep mode === 537 537 538 538 ... ... @@ -539,25 +539,35 @@ 539 539 Feature: Set device to sleep mode 540 540 541 541 * **AT+Sleep=0** : Normal working mode, device will sleep and use lower power when there is no LoRa message 575 + 542 542 * **AT+Sleep=1** : Device is in deep sleep mode, no LoRa activation happen, used for storage or shipping. 543 543 544 544 (% style="color:#4f81bd" %)**AT Command: AT+SLEEP** 545 545 546 -[[image:image-20220523151218-7.png||_mstalt="430703"]] 580 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:513px" %) 581 +|(% style="background-color:#d9e2f3; color:#0070c0; width:155px" %)**Command Example**|(% style="background-color:#d9e2f3; color:#0070c0; width:140px" %)**Function**|(% style="background-color:#d9e2f3; color:#0070c0; width:218px" %)**Response** 582 +|(% style="width:155px" %)AT+SLEEP|(% style="width:139px" %)Set to sleep mode|(% style="width:213px" %)((( 583 +Clear all stored sensor data… 547 547 585 +OK 586 +))) 548 548 549 549 (% style="color:#4f81bd" %)**Downlink Command:** 550 550 551 551 * There is no downlink command to set to Sleep mode. 552 552 592 + 593 + 553 553 === 4.3.5 Set UOA (Uplink on Activity) === 554 554 596 + 555 555 Feature: Enable / Disable Uplink on Activity 556 556 557 557 * **AT+UOA=0** : Disable UoA 600 + 558 558 * **AT+UOA=1,2** : Enable UoA , Calm Down Time: 2 minutes. If device already send a uplink on activity, it will not send another uplink on activiy in 2 minutes, even detect activity. 559 559 560 -Notice: Calm Down time range is 1 ~~ 65535 minutes. If user set Calm Down time to low value, such as 1 minute, the sensor might send uplink very frequenctly and battery drain fast. 603 +(% style="color:red" %)**Notice: Calm Down time range is 1 ~~ 65535 minutes. If user set Calm Down time to low value, such as 1 minute, the sensor might send uplink very frequenctly and battery drain fast.** 561 561 562 562 (% style="color:#4f81bd" %)**AT Command: AT+UOA** 563 563 ... ... @@ -567,6 +567,7 @@ 567 567 568 568 = 5. Battery & Power Consumption = 569 569 613 + 570 570 LHT65N-PIR use **CR17450** battery pack. See below link for detail information about the battery info and how to replace. 571 571 572 572 [[**Battery Info & Power Consumption Analyze**>>url:http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20calculate%20the%20battery%20life%20of%20Dragino%20sensors%3F/]] . ... ... @@ -574,8 +574,9 @@ 574 574 575 575 = 6. OTA firmware update = 576 576 577 -User can change firmware S31x-LB to: 578 578 622 +User can change firmware LHT65N-PIR to: 623 + 579 579 * Change Frequency band/ region. 580 580 * Update with new features. 581 581 * Fix bugs. ... ... @@ -587,12 +587,14 @@ 587 587 * (Recommanded way) OTA firmware update via wireless: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/]] 588 588 * Update through UART TTL interface. **[[Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware]]**. 589 589 635 + 636 + 590 590 = 7. FAQ = 591 591 592 592 == 7.1 How to use AT Command? == 593 593 594 594 595 -LHT65N- E5supports AT Command set.User can use a USB to TTL adapter plus the Program Cable to connect to LHT65 for using AT command, as below.642 +LHT65N-PIR supports AT Command set.User can use a USB to TTL adapter plus the Program Cable to connect to LHT65 for using AT command, as below. 596 596 597 597 598 598 [[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615153355-1.png||_mstalt="430222"]] ... ... @@ -602,12 +602,11 @@ 602 602 [[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@1655802313617-381.png||_mstalt="293917"]] 603 603 604 604 605 -In PC, User needs to set serial tool(such as [[**putty**>>https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to (% style="color:green" %)**9600** (%%)to access to access serial console for LHT65N- E5. The AT commands are disable by default and need to enter password (default:(% style="color:green" %)**123456**(% style="color:red" %))(%%) to active it. Timeout to input AT Command is 5 min, after 5-minute, user need to input password again. User can use AT+DISAT command to disable AT command before timeout.652 +In PC, User needs to set serial tool(such as [[**putty**>>https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to (% style="color:green" %)**9600** (%%)to access to access serial console for LHT65N-PIR. The AT commands are disable by default and need to enter password (default:(% style="color:green" %)**123456**(% style="color:red" %))(%%) to active it. Timeout to input AT Command is 5 min, after 5-minute, user need to input password again. User can use AT+DISAT command to disable AT command before timeout. 606 606 607 607 [[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615154519-3.png||_mstalt="431925" height="672" width="807"]] 608 608 609 609 610 - 611 611 == 7.2 Where to use AT commands and Downlink commands == 612 612 613 613 ... ... @@ -649,6 +649,7 @@ 649 649 650 650 == 7.3 How to change the uplink interval? == 651 651 698 + 652 652 Please see this link: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/How%20to%20set%20the%20transmit%20time%20interval/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20set%20the%20transmit%20time%20interval/||_mstmutation="1" style="background-color: rgb(255, 255, 255);"]] 653 653 654 654 [[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615154519-3.png||_mstalt="431925" height="672" width="807"]] ... ... @@ -656,6 +656,7 @@ 656 656 657 657 == 7.4 How to use TTL-USB to connect PC to upgrade firmware? == 658 658 706 + 659 659 [[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615153355-1.png||_mstalt="430222"]] 660 660 661 661 (% style="color:blue" %)**Step1**(%%): Install TremoProgrammer first. ... ... @@ -711,6 +711,8 @@ 711 711 * (% style="color:#4f81bd" %)** **(% _mstmutation="1" style="color:red" %)**IN865**(%%): LoRaWAN IN865 band 712 712 * (% style="color:#4f81bd" %)** **(% _mstmutation="1" style="color:red" %)**CN470**(%%): LoRaWAN CN470 band 713 713 762 + 763 + 714 714 = 9. Packing Info = 715 715 716 716 ... ... @@ -723,11 +723,15 @@ 723 723 * Device Size: 10 x 10 x 3.5 mm 724 724 * Device Weight: 120.5g 725 725 776 + 777 + 726 726 = 10. Reference material = 727 727 728 728 729 729 * [[Datasheet, photos, decoder, firmware>>https://www.dropbox.com/sh/una19zsni308dme/AACOKp6J2RF5TMlKWT5zU3RTa?dl=0]] 730 730 783 + 784 + 731 731 = 11. FCC Warning = 732 732 733 733
- LHT65N-PIR1.jpg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ellie - Size
-
... ... @@ -1,0 +1,1 @@ 1 +47.3 KB - Content