Changes for page LHT65N-PIR Temperature/Humidity/PIR Motion Sensor User Manual
Last modified by Xiaoling on 2025/06/10 09:17
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -145,21 +145,21 @@ 145 145 [[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220522232916-3.png||_mstalt="430495"]] 146 146 147 147 148 -[[image:image-20220522232932-4.png|| _mstalt="430157"]]148 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N-E5%20LoRaWAN%20Temperature_Humidity%20%26%20Illuminance%20Sensor%20User%20Manual/WebHome/image-20220522232932-4.png?rev=1.1||alt="image-20220522232932-4.png"]] 149 149 150 150 151 -[[image:image-20220522232954-5.png|| _mstalt="431847"]]151 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N-E5%20LoRaWAN%20Temperature_Humidity%20%26%20Illuminance%20Sensor%20User%20Manual/WebHome/image-20220522232954-5.png?rev=1.1||alt="image-20220522232954-5.png"]] 152 152 153 153 154 154 (% style="color:red" %)**Note: LHT65N-PIR use same payload decoder as LHT65.** 155 155 156 156 157 -[[image:image-20220522233026-6.png|| _mstalt="429403"]]157 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N-E5%20LoRaWAN%20Temperature_Humidity%20%26%20Illuminance%20Sensor%20User%20Manual/WebHome/image-20220522233026-6.png?rev=1.1||alt="image-20220522233026-6.png"]] 158 158 159 159 160 160 **Input APP EUI, APP KEY and DEV EUI:** 161 161 162 -[[image:image-20220522233118-7.png|| _mstalt="430430"]]162 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N-E5%20LoRaWAN%20Temperature_Humidity%20%26%20Illuminance%20Sensor%20User%20Manual/WebHome/image-20220522233118-7.png?rev=1.1||alt="image-20220522233118-7.png"]] 163 163 164 164 165 165 === 2.3.2 Step 2: Activate LHT65N-PIR by pressing the ACT button for more than 5 seconds. === ... ... @@ -168,7 +168,7 @@ 168 168 Use ACT button to activate LHT65N-PIR and it will auto-join to the TTN V3 network. After join success, it will start to upload sensor data to TTN V3 and user can see in the panel. 169 169 170 170 171 -[[image:image-20220522233300-8.png|| _mstalt="428389" height="219" width="722"]]171 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N-E5%20LoRaWAN%20Temperature_Humidity%20%26%20Illuminance%20Sensor%20User%20Manual/WebHome/image-20220522233300-8.png?rev=1.1||alt="image-20220522233300-8.png"]] 172 172 173 173 174 174 == 2.4 Uplink Payload~-~-Device Status, (Fport~=5) == ... ... @@ -262,19 +262,19 @@ 262 262 |(% style="width:97px" %)((( 263 263 **Value** 264 264 )))|(% style="width:39px" %)((( 265 -[[BAT>>||anchor="H2. 4.2BAT-BatteryInfo"]]265 +[[BAT>>||anchor="H2.5.2BAT-BatteryInfo"]] 266 266 )))|(% style="width:100px" %)((( 267 267 ((( 268 -[[Built-In Temperature>>||anchor="H2. 4.3Built-inTemperature"]]268 +[[Built-In Temperature>>||anchor="H2.5.3Built-inTemperature"]] 269 269 ))) 270 270 )))|(% style="width:77px" %)((( 271 271 ((( 272 -[[Built-in Humidity>>||anchor="H2. 4.4Built-inHumidity"]]272 +[[Built-in Humidity>>||anchor="H2.5.4Built-inHumidity"]] 273 273 ))) 274 274 )))|(% style="width:47px" %)((( 275 275 Ext # 276 276 )))|(% style="width:51px" %)((( 277 -[[Ext value>>||anchor="H2.5.5 .2ExtValue"]]277 +[[Ext value>>||anchor="H2.5.5Extvalue"]] 278 278 ))) 279 279 280 280 * The First 6 bytes: has fix meanings for every LHT65N-PIR. ... ... @@ -298,7 +298,19 @@ 298 298 299 299 These two bytes of BAT include the battery state and the actually voltage 300 300 301 -[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220523152839-18.png||_mstalt="457613"]] 301 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:477px" %) 302 +|=(% style="width: 69px; background-color:#D9E2F3;color:#0070C0" %)((( 303 +**Bit(bit)** 304 +)))|=(% style="width: 253px;background-color:#D9E2F3;color:#0070C0" %)[15:14]|=(% style="width: 155px;background-color:#D9E2F3;color:#0070C0" %)[13:0] 305 +|(% style="width:66px" %)((( 306 +**Value** 307 +)))|(% style="width:250px" %)((( 308 +BAT Status 309 +00(b): Ultra Low ( BAT <= 2.50v) 310 +01(b): Low (2.50v <=BAT <= 2.55v) 311 +10(b): OK (2.55v <= BAT <=2.65v) 312 +11(b): Good (BAT >= 2.65v) 313 +)))|(% style="width:152px" %)Actually BAT voltage 302 302 303 303 304 304 [[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220522235639-1.png||_mstalt="431392" height="139" width="727"]] ... ... @@ -338,19 +338,19 @@ 338 338 339 339 Bit0 of byte 8th shows if this uplink is generate by PIR activity. 340 340 341 -(% border="1" cellspacing="4" style="background-color:#fff fcc;color:green;width:490px" %)342 -|=(% style="width: 1 47px;" %)(((353 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:393px" %) 354 +|=(% style="width: 106px; background-color: rgb(217, 226, 243); color: rgb(0, 112, 192);" %)((( 343 343 **The 8^^th^^ byte** 344 -)))|=(% style="width: 1 08px;" %)(((356 +)))|=(% style="width: 71px; background-color: rgb(217, 226, 243); color: rgb(0, 112, 192);" %)((( 345 345 **Bit 1~~7** 346 -)))|=(% style="width: 2 28px;" %)(((358 +)))|=(% style="width: 211px; background-color: rgb(217, 226, 243); color: rgb(0, 112, 192);" %)((( 347 347 **Bit 0** 348 348 ))) 349 -|(% style="width:1 47px" %)(((361 +|(% style="width:106px" %)((( 350 350 **Value** 351 -)))|(% style="width:1 08px" %)(((363 +)))|(% style="width:71px" %)((( 352 352 Reserve 353 -)))|(% style="width:2 28px" %)(((365 +)))|(% style="width:211px" %)((( 354 354 ((( 355 355 0: Normal Uplink 356 356 ... ... @@ -358,7 +358,7 @@ 358 358 ))) 359 359 ))) 360 360 361 -**Note**: Uplink by activity is disable by default. 373 +(% style="color:red" %)**Note**:** Uplink by activity is disable by default.** 362 362 363 363 364 364 The 9^^th^^ ~~ 11^^st^^ byte: Movement Detect Count. ... ... @@ -455,7 +455,7 @@ 455 455 456 456 LHT65N-PIR supports below configure method: 457 457 458 -* AT Command via UART Connection : See [[FAQ>> path:#H7.FAQ]].470 +* AT Command via UART Connection : See [[FAQ>>||anchor="H7.FAQ"]]. 459 459 * LoRaWAN Downlink. Instruction for different platforms: See [[IoT LoRaWAN Server>>url:http://wiki.dragino.com/xwiki/bin/view/Main/]] section. 460 460 461 461 == 4.2 General Commands == ... ... @@ -485,9 +485,11 @@ 485 485 486 486 (% style="color:#4f81bd" %)**AT Command: AT+TDC** 487 487 488 -[[image:image-20220523150701-2.png||_mstalt="427453"]] 500 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:501px" %) 501 +|(% style="background-color:#d9e2f3; color:#0070c0; width:155px" %)**Command Example**|(% style="background-color:#d9e2f3; color:#0070c0; width:166px" %)**Function**|(% style="background-color:#d9e2f3; color:#0070c0; width:180px" %)**Response** 502 +|(% style="width:155px" %)AT+TDC?|(% style="width:162px" %)Show current transmit Interval|(% style="width:177px" %)30000 OK the interval is 30000ms = 30s 503 +|(% style="width:155px" %)AT+TDC=60000|(% style="width:162px" %)Set Transmit Interval|(% style="width:177px" %)OK Set transmit interval to 60000ms = 60 seconds 489 489 490 - 491 491 (% style="color:#4f81bd" %)**Downlink Payload: 0x01** 492 492 493 493 Format: Command Code (0x01) followed by 3 bytes time value. ... ... @@ -513,26 +513,24 @@ 513 513 Feature: Set device password, max 9 digits 514 514 515 515 516 -(% style="color:#4f81bd" %)**AT Command: AT+ EXT**530 +(% style="color:#4f81bd" %)**AT Command: AT+PWORD** 517 517 518 -(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %) 519 -|Command Example|Function|Response 520 -|AT+EXT=?|Get or Set external sensor model|((( 521 -5 522 522 523 -OK 533 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:372px" %) 534 +|(% style="background-color:#d9e2f3; color:#0070c0; width:155px" %)**Command Example**|(% style="background-color:#d9e2f3; color:#0070c0; width:128px" %)**Function**|(% style="background-color:#d9e2f3; color:#0070c0; width:89px" %)**Response** 535 +|(% style="width:155px" %)AT+PWORD=?|(% style="width:124px" %)Show password|(% style="width:86px" %)((( 536 +123456 537 + 538 +OK 524 524 ))) 525 -|AT+ EXT=5|(%colspan="2" %)Setexternalsensormodeto5540 +|(% style="width:155px" %)AT+PWORD=999999|(% style="width:124px" %)Set password|(% style="width:86px" %)OK 526 526 527 -(% style="color:#4f81bd" %)**Downlink Command: 0xA2**542 +(% style="color:#4f81bd" %)**Downlink Command:** 528 528 544 +No downlink command for this feature. 529 529 530 -Total bytes: 2 bytes 531 531 532 -**Example:** 533 533 534 -* 0xA205: Set external sensor type to E5 535 - 536 536 === 4.3.4 Set to sleep mode === 537 537 538 538 ... ... @@ -539,6 +539,7 @@ 539 539 Feature: Set device to sleep mode 540 540 541 541 * **AT+Sleep=0** : Normal working mode, device will sleep and use lower power when there is no LoRa message 554 + 542 542 * **AT+Sleep=1** : Device is in deep sleep mode, no LoRa activation happen, used for storage or shipping. 543 543 544 544 (% style="color:#4f81bd" %)**AT Command: AT+SLEEP**