Last modified by Xiaoling on 2025/06/10 09:17

From version 37.4
edited by Xiaoling
on 2023/04/27 08:58
Change comment: There is no comment for this version
To version 23.1
edited by Edwin Chen
on 2023/04/11 13:55
Change comment: Uploaded new attachment "image-20230411135341-1.png", version {1}

Summary

Details

Page properties
Title
... ... @@ -1,1 +1,1 @@
1 -LHT65N-PIR Temperature/Humidity/PIR Motion Sensor User Manual
1 +LHT65-PIR Temperature/Humidity/PIR Motion Sensor User Manual
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Xiaoling
1 +XWiki.Edwin
Content
... ... @@ -100,19 +100,9 @@
100 100  
101 101  [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N-E5%20LoRaWAN%20Temperature_Humidity%20%26%20Illuminance%20Sensor%20User%20Manual/WebHome/image-20220515123819-1.png?width=317&height=379&rev=1.1||alt="image-20220515123819-1.png" height="379" width="317"]]
102 102  
103 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N-E5%20LoRaWAN%20Temperature_Humidity%20%26%20Illuminance%20Sensor%20User%20Manual/WebHome/image-20220525110604-2.png?rev=1.1||alt="image-20220525110604-2.png"]]
103 103  
104 104  
105 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %)
106 -|=(% style="width: 167px;background-color:#D9E2F3;color:#0070C0" %)**Behavior on ACT**|=(% style="width: 117px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 225px;background-color:#D9E2F3;color:#0070C0" %)**Action**
107 -|(% style="background-color:#f2f2f2; width:167px" %)Pressing ACT between 1s < time < 3s|(% style="background-color:#f2f2f2; width:117px" %)Test uplink status|(% style="background-color:#f2f2f2; width:225px" %)(((
108 -If LHT65N is already Joined to rhe LoRaWAN network, LHT65N will send an uplink packet, if LHT65N has external sensor connected,(% style="color:blue" %)**Blue led** (%%)will blink once. If LHT65N has not external sensor, (% style="color:red" %)**Red led**(%%) will blink once.
109 -)))
110 -|(% style="background-color:#f2f2f2; width:167px" %)Pressing ACT for more than 3s|(% style="background-color:#f2f2f2; width:117px" %)Active Device|(% style="background-color:#f2f2f2; width:225px" %)(((
111 -(% style="background-color:#f2f2f2; color:green" %)**Green led**(%%) will fast blink 5 times, LHT65N will enter working mode and start to JOIN LoRaWAN network.
112 -(% style="background-color:#f2f2f2; color:green" %)**Green led**(%%) will solidly turn on for 5 seconds after join in network.
113 -)))
114 -|(% style="background-color:#f2f2f2; width:167px" %)Fast press ACT 5 times.|(% style="background-color:#f2f2f2; width:117px" %)Deactivate Device|(% style="background-color:#f2f2f2; width:225px" %)(% style="color:red" %)**Red led**(%%) will solid on for 5 seconds. Means LHT65N is in Deep Sleep Mode.
115 -
116 116  == 2.3 Example to join LoRaWAN network ==
117 117  
118 118  
... ... @@ -134,9 +134,8 @@
134 134  
135 135  Each LHT65N-PIR is shipped with a sticker with its device EUI, APP Key and APP EUI as below:
136 136  
137 -[[image:image-20230426083533-1.png]]
127 +[[image:image-20220617150003-1.jpeg||_mstalt="5426434"]]
138 138  
139 -
140 140  User can enter these keys in the LoRaWAN Server portal. Below is TTN V3 screenshot:
141 141  
142 142  Add APP EUI in the application.
... ... @@ -151,37 +151,31 @@
151 151  [[image:image-20220522232954-5.png||_mstalt="431847"]]
152 152  
153 153  
143 +
154 154  (% style="color:red" %)**Note: LHT65N-PIR use same payload decoder as LHT65.**
155 155  
156 156  
157 -[[image:image-20220522233026-6.png||_mstalt="429403"]]
147 +Input APP EUI,  APP KEY and DEV EUI:
158 158  
159 159  
160 -**Input APP EUI,  APP KEY and DEV EUI:**
161 -
162 162  [[image:image-20220522233118-7.png||_mstalt="430430"]]
163 163  
164 164  
165 165  === 2.3.2 Step 2: Activate LHT65N-PIR by pressing the ACT button for more than 5 seconds. ===
166 166  
167 -
168 168  Use ACT button to activate LHT65N-PIR and it will auto-join to the TTN V3 network. After join success, it will start to upload sensor data to TTN V3 and user can see in the panel.
169 -
170 -
171 171  [[image:image-20220522233300-8.png||_mstalt="428389" height="219" width="722"]]
172 172  
173 173  
174 174  == 2.4 Uplink Payload~-~-Device Status, (Fport~=5) ==
175 175  
176 -
177 177  Users can use the downlink command(**0x26 01**) to ask LHT65N-PIR to send device configure detail, include device configure status. LHT65N-PIR will uplink a payload via FPort=5 to server.
178 178  
179 179  The Payload format is as below.
180 180  
181 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %)
182 -|(% colspan="6" style="background-color:#d9e2f3; color:#0070c0" %)**Device Status (FPORT=5)**
183 -|(% style="background-color:#f2f2f2; width:103px" %)**Size (bytes)**|(% style="background-color:#f2f2f2; width:72px" %)**1**|(% style="background-color:#f2f2f2" %)**2**|(% style="background-color:#f2f2f2; width:91px" %)**1**|(% style="background-color:#f2f2f2; width:86px" %)**1**|(% style="background-color:#f2f2f2; width:44px" %)**2**
184 -|(% style="background-color:#f2f2f2; width:103px" %)**Value**|(% style="background-color:#f2f2f2; width:72px" %)Sensor Model|(% style="background-color:#f2f2f2" %)Firmware Version|(% style="background-color:#f2f2f2; width:91px" %)Frequency Band|(% style="background-color:#f2f2f2; width:86px" %)Sub-band|(% style="background-color:#f2f2f2; width:44px" %)BAT
165 +|(% colspan="6" %)**Device Status (FPORT=5)**
166 +|**Size (bytes)**|**1**|**2**|**1**|**1**|**2**
167 +|**Value**|Sensor Model|Firmware Version|Frequency Band|Sub-band|BAT
185 185  
186 186  Example parse in TTNv3
187 187  
... ... @@ -240,23 +240,22 @@
240 240  
241 241  == 2.5 Uplink Payload, Sensor Data  ( Fport~=2) ==
242 242  
243 -
244 244  The uplink payload includes totally 11 bytes. Uplink packets use FPORT=2 and (% style="color:#4f81bd" %)**every 20 minutes**(%%) send one uplink by default.
245 245  
246 246  After each uplink, the (% style="color:blue" %)**BLUE LED**(%%) will blink once.
247 247  
248 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:390px" %)
249 -|=(% style="width: 60px;background-color:#D9E2F3" %)(((
230 +(% border="1" cellspacing="4" style="background-color:#ffffcc; color:green; width:390px" %)
231 +|=(% style="width: 60px;" %)(((
250 250  **Size(bytes)**
251 -)))|=(% style="width: 30px;background-color:#D9E2F3" %)(((
233 +)))|=(% style="width: 30px;" %)(((
252 252  **2**
253 -)))|=(% style="width: 100px;background-color:#D9E2F3" %)(((
235 +)))|=(% style="width: 100px;" %)(((
254 254  **2**
255 -)))|=(% style="width: 100px;background-color:#D9E2F3" %)(((
237 +)))|=(% style="width: 100px;" %)(((
256 256  **2**
257 -)))|=(% style="width: 50px;background-color:#D9E2F3" %)(((
239 +)))|=(% style="width: 50px;" %)(((
258 258  **1**
259 -)))|=(% style="width: 50px;background-color:#D9E2F3" %)(((
241 +)))|=(% style="width: 50px;" %)(((
260 260  **4**
261 261  )))
262 262  |(% style="width:97px" %)(((
... ... @@ -272,9 +272,9 @@
272 272  [[Built-in Humidity>>||anchor="H2.4.4Built-inHumidity"]]
273 273  )))
274 274  )))|(% style="width:47px" %)(((
275 -Ext #
257 +[[Ext>>||anchor="H2.4.5Ext23"]] #
276 276  )))|(% style="width:51px" %)(((
277 -[[Ext value>>||anchor="H2.5.5.2ExtValue"]]
259 +[[Ext value>>||anchor="H2.4.6Extvalue"]]
278 278  )))
279 279  
280 280  * The First 6 bytes: has fix meanings for every LHT65N-PIR.
... ... @@ -416,10 +416,7 @@
416 416  
417 417  2. Towards the PIR probe to the place where need to monitor activity. Below is the detect beam.
418 418  
419 -Stable distance is 0~~3m. Some motion might not detected between 3~~5 m.
420 420  
421 -[[image:image-20230411135341-1.png||height="450" width="456"]]
422 -
423 423  **Notice: PIR can only detect motion activity, not to use to detect static people case.**
424 424  
425 425  * 1. PIR Motion Detector should not be installed near the Air conditioner places where with cold wind or hot wind flow, because PIR motion detector is sensitive with the temperature changes of the environment. Environment changes quickly will cause a false alarm.
... ... @@ -428,6 +428,9 @@
428 428  * 4. Between the detection range of PIR Motion detector, there is should be less objects.  Many objects may reduce the sensitive of detection range.
429 429  * 5. Do not install more than one (2 or above) Wireless PIR in the same detection space (like at the same room).
430 430  
410 +
411 +
412 +
431 431  = 3. Sensors and Accessories =
432 432  
433 433  == 3.1 E2 Extension Cable ==
... ... @@ -574,19 +574,9 @@
574 574  
575 575  = 6. OTA firmware update =
576 576  
577 -User can change firmware S31x-LB to:
559 +Please see this link for how to do OTA firmware update: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/]]
578 578  
579 -* Change Frequency band/ region.
580 -* Update with new features.
581 -* Fix bugs.
582 582  
583 -Firmware and changelog can be downloaded from : **[[Firmware download link>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/]]**
584 -
585 -Methods to Update Firmware:
586 -
587 -* (Recommanded way) OTA firmware update via wireless: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/]]
588 -* Update through UART TTL interface. **[[Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware]]**.
589 -
590 590  = 7. FAQ =
591 591  
592 592  == 7.1 How to use AT Command? ==
... ... @@ -647,7 +647,7 @@
647 647  [[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615092939-4.png||_mstalt="434460" height="448" width="894"]]
648 648  
649 649  
650 -== 7.3 How to change the uplink interval? ==
622 +== 6.3 How to change the uplink interval? ==
651 651  
652 652  Please see this link: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/How%20to%20set%20the%20transmit%20time%20interval/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20set%20the%20transmit%20time%20interval/||_mstmutation="1" style="background-color: rgb(255, 255, 255);"]]
653 653  
1FPORT=5.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ellie
Size
... ... @@ -1,1 +1,0 @@
1 -34.8 KB
Content
ACT.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ellie
Size
... ... @@ -1,1 +1,0 @@
1 -49.3 KB
Content
AT+SLEEP.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ellie
Size
... ... @@ -1,1 +1,0 @@
1 -5.8 KB
Content
AT+TDC.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ellie
Size
... ... @@ -1,1 +1,0 @@
1 -12.3 KB
Content
FPORT=5.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ellie
Size
... ... @@ -1,1 +1,0 @@
1 -29.4 KB
Content
LHT65N-E5.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ellie
Size
... ... @@ -1,1 +1,0 @@
1 -215.2 KB
Content
add application1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ellie
Size
... ... @@ -1,1 +1,0 @@
1 -44.5 KB
Content
add application2.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ellie
Size
... ... @@ -1,1 +1,0 @@
1 -53.7 KB
Content
image-20230426083533-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -190.0 KB
Content
input APP EUI.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ellie
Size
... ... @@ -1,1 +1,0 @@
1 -57.6 KB
Content
shipped.jpeg
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ellie
Size
... ... @@ -1,1 +1,0 @@
1 -16.5 KB
Content