Changes for page LHT65N-PIR Temperature/Humidity/PIR Motion Sensor User Manual
Last modified by Xiaoling on 2025/06/10 09:17
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 3 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,14 +1,9 @@ 1 1 (% style="text-align:center" %) 2 -[[image:image-20221206143242-2.png ||height="602" width="551"]]2 +[[image:LHT65N-PIR1.jpg||alt="image-20221206143242-2.png" height="484" width="485"]] 3 3 4 4 5 5 6 6 7 - 8 - 9 - 10 - 11 - 12 12 **Table of Contents:** 13 13 14 14 {{toc/}} ... ... @@ -18,9 +18,6 @@ 18 18 19 19 20 20 21 - 22 - 23 - 24 24 = 1. Introduction = 25 25 26 26 == 1.1 What is LHT65N-PIR Temperature,Humidity & PIR Sensor == ... ... @@ -135,7 +135,7 @@ 135 135 136 136 Each LHT65N-PIR is shipped with a sticker with its device EUI, APP Key and APP EUI as below: 137 137 138 -[[image:image-20230426083533-1.png]] 130 +[[image:image-20230426083533-1.png||height="286" width="616"]] 139 139 140 140 141 141 User can enter these keys in the LoRaWAN Server portal. Below is TTN V3 screenshot: ... ... @@ -186,7 +186,7 @@ 186 186 187 187 Example parse in TTNv3 188 188 189 -[[image: 1675144504430-490.png]]181 +[[image:image-20230508151932-1.png]] 190 190 191 191 **Sensor Model**: For LHT65N-PIR, this value is 0x1A 192 192 ... ... @@ -339,9 +339,9 @@ 339 339 340 340 === 2.5.5 Ext value === 341 341 342 -==== 2.5.5.1 Ext~=0x0 A, PIR Sensor ====334 +==== 2.5.5.1 Ext~=0x0E, PIR Sensor ==== 343 343 344 -[[image:image-20221224161634-2.png ||height="138" width="851"]]336 +[[image:ext=14.png||alt="image-20221224161634-2.png"]] 345 345 346 346 347 347 ==== 2.5.5.2 Ext Value ==== ... ... @@ -366,7 +366,6 @@ 366 366 )))|(% style="width:211px" %)((( 367 367 ((( 368 368 0: Normal Uplink 369 - 370 370 1: Uplink by activity detected 371 371 ))) 372 372 ))) ... ... @@ -418,10 +418,10 @@ 418 418 419 419 In a normal working state: 420 420 421 -* For each uplink, the BLUE LED or RED LED will blink once. 422 -BLUE LED when external sensor is connected. 423 -* RED LED when external sensor is not connected 424 -* For each success downlink, the PURPLE LED will blink once 412 +* For each uplink, the (% style="color:blue" %)**BLUE LED**(%%) or (% style="color:red" %)**RED LED**(%%) will blink once. 413 +(% style="color:blue" %)**BLUE LED**(%%) when external sensor is connected. 414 +* (% style="color:red" %)**RED LED**(%%) when external sensor is not connected 415 +* For each success downlink, the (% style="color:purple" %)**PURPLE LED**(%%) will blink once 425 425 426 426 == 2.8 installation == 427 427 ... ... @@ -437,9 +437,13 @@ 437 437 (% style="color:red" %)**Notice: PIR can only detect motion activity, not to use to detect static people case.** 438 438 439 439 * 1. PIR Motion Detector should not be installed near the Air conditioner places where with cold wind or hot wind flow, because PIR motion detector is sensitive with the temperature changes of the environment. Environment changes quickly will cause a false alarm. 431 + 440 440 * 2. PIR should not be installed facing the glass window, facing glass window will be interfered by the outside sunlight and moving objects (people or vehicle). The infrared energy can penetrate the glass window. 433 + 441 441 * 3. PIR should not be installed facing the moving objects or background changing objects, movement object will cause airflow change, it may cause false alarm. 435 + 442 442 * 4. Between the detection range of PIR Motion detector, there is should be less objects. Many objects may reduce the sensitive of detection range. 437 + 443 443 * 5. Do not install more than one (2 or above) Wireless PIR in the same detection space (like at the same room). 444 444 445 445 = 3. Sensors and Accessories = ... ... @@ -450,7 +450,7 @@ 450 450 [[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220619092222-1.png||_mstalt="429533" height="182" width="188"]][[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220619092313-2.png||_mstalt="430222" height="182" width="173"]] 451 451 452 452 453 -**1m long breakout cable for LHT65N- E5. Features:**448 +**1m long breakout cable for LHT65N-PIR. Features:** 454 454 455 455 * ((( 456 456 Use for AT Command ... ... @@ -470,6 +470,7 @@ 470 470 LHT65N-PIR supports below configure method: 471 471 472 472 * AT Command via UART Connection : See [[FAQ>>||anchor="H7.FAQ"]]. 468 + 473 473 * LoRaWAN Downlink. Instruction for different platforms: See [[IoT LoRaWAN Server>>url:http://wiki.dragino.com/xwiki/bin/view/Main/]] section. 474 474 475 475 == 4.2 General Commands == ... ... @@ -623,12 +623,11 @@ 623 623 [[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@1655802313617-381.png||_mstalt="293917"]] 624 624 625 625 626 -In PC, User needs to set serial tool(such as [[**putty**>>https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to (% style="color:green" %)**9600** (%%)to access to access serial console for LHT65N- E5. The AT commands are disable by default and need to enter password (default:(% style="color:green" %)**123456**(% style="color:red" %))(%%) to active it. Timeout to input AT Command is 5 min, after 5-minute, user need to input password again. User can use AT+DISAT command to disable AT command before timeout.622 +In PC, User needs to set serial tool(such as [[**putty**>>https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to (% style="color:green" %)**9600** (%%)to access to access serial console for LHT65N-PIR. The AT commands are disable by default and need to enter password (default:(% style="color:green" %)**123456**(% style="color:red" %))(%%) to active it. Timeout to input AT Command is 5 min, after 5-minute, user need to input password again. User can use AT+DISAT command to disable AT command before timeout. 627 627 628 628 [[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615154519-3.png||_mstalt="431925" height="672" width="807"]] 629 629 630 630 631 - 632 632 == 7.2 Where to use AT commands and Downlink commands == 633 633 634 634
- LHT65N-PIR1.jpg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ellie - Size
-
... ... @@ -1,0 +1,1 @@ 1 +47.3 KB - Content
- ext=14.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ellie - Size
-
... ... @@ -1,0 +1,1 @@ 1 +30.5 KB - Content
- image-20230508151932-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.kai - Size
-
... ... @@ -1,0 +1,1 @@ 1 +36.0 KB - Content