Changes for page LHT65N-PIR Temperature/Humidity/PIR Motion Sensor User Manual
Last modified by Xiaoling on 2025/06/10 09:17
From version 37.10
edited by Xiaoling
on 2023/04/27 10:37
on 2023/04/27 10:37
Change comment:
There is no comment for this version
To version 40.1
edited by Ellie Zhang
on 2023/05/06 10:51
on 2023/05/06 10:51
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Xiaoling1 +XWiki.Ellie - Content
-
... ... @@ -1,5 +1,5 @@ 1 1 (% style="text-align:center" %) 2 -[[image:image-20221206143242-2.png ||height="602" width="551"]]2 +[[image:LHT65N-PIR1.jpg||alt="image-20221206143242-2.png" height="679" width="681"]] 3 3 4 4 5 5 ... ... @@ -8,7 +8,6 @@ 8 8 9 9 10 10 11 - 12 12 **Table of Contents:** 13 13 14 14 {{toc/}} ... ... @@ -53,6 +53,7 @@ 53 53 * External PIR Sensor 54 54 * Tri-color LED to indicate working status(% style="display:none" %) 55 55 55 + 56 56 == 1.3 Specification == 57 57 58 58 ... ... @@ -78,6 +78,7 @@ 78 78 * (% class="mark" %)Range: 0-65535 lx 79 79 * (% class="mark" %)Operating Range: -40 °C ~~ 85 °C 80 80 81 + 81 81 = 2. Connect LHT65N-PIR to IoT Server = 82 82 83 83 == 2.1 How does LHT65N-PIR work? == ... ... @@ -114,6 +114,7 @@ 114 114 ))) 115 115 |(% style="background-color:#f2f2f2; width:167px" %)Fast press ACT 5 times.|(% style="background-color:#f2f2f2; width:117px" %)Deactivate Device|(% style="background-color:#f2f2f2; width:225px" %)(% style="color:red" %)**Red led**(%%) will solid on for 5 seconds. Means LHT65N is in Deep Sleep Mode. 116 116 118 + 117 117 == 2.3 Example to join LoRaWAN network == 118 118 119 119 ... ... @@ -186,7 +186,7 @@ 186 186 187 187 Example parse in TTNv3 188 188 189 -[[image:1675144504430-490.png]] 191 +[[image:1FPORT=5.png||alt="1675144504430-490.png" height="265" width="1150"]] 190 190 191 191 **Sensor Model**: For LHT65N-PIR, this value is 0x1A 192 192 ... ... @@ -283,6 +283,7 @@ 283 283 * The 8^^th^^ byte: Alarm Bit (if this uplink is from periodically or movement) 284 284 * The 9^^th^^ ~~ 11^^st^^ byte: Movement Detect Count. 285 285 288 + 286 286 === 2.5.1 Decoder in TTN V3 === 287 287 288 288 ... ... @@ -321,6 +321,7 @@ 321 321 * BAT status=(0xcba4>>14)&0xFF=11(B),very good 322 322 * Battery Voltage =0xCBF6&0x3FFF=0x0BA4=2980mV 323 323 327 + 324 324 === 2.5.3 Built-in Temperature === 325 325 326 326 [[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220522235639-2.png||_mstalt="431756" height="138" width="722"]] ... ... @@ -331,6 +331,7 @@ 331 331 332 332 * Temperature: (0xF5C6-65536)/100=-26.18℃ 333 333 338 + 334 334 === 2.5.4 Built-in Humidity === 335 335 336 336 [[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220522235639-4.png||_mstalt="432484" height="138" width="722"]] ... ... @@ -337,6 +337,7 @@ 337 337 338 338 * Humidity: 0x025C/10=60.4% 339 339 345 + 340 340 === 2.5.5 Ext value === 341 341 342 342 ==== 2.5.5.1 Ext~=0x0A, PIR Sensor ==== ... ... @@ -418,11 +418,12 @@ 418 418 419 419 In a normal working state: 420 420 421 -* For each uplink, the BLUE LED or RED LED will blink once. 422 -BLUE LED when external sensor is connected. 423 -* RED LED when external sensor is not connected 427 +* For each uplink, the **BLUE LED** or **RED LED** will blink once. 428 +**BLUE LED** when external sensor is connected. 429 +* **RED LED** when external sensor is not connected 424 424 * For each success downlink, the PURPLE LED will blink once 425 425 432 + 426 426 == 2.8 installation == 427 427 428 428 ... ... @@ -442,6 +442,7 @@ 442 442 * 4. Between the detection range of PIR Motion detector, there is should be less objects. Many objects may reduce the sensitive of detection range. 443 443 * 5. Do not install more than one (2 or above) Wireless PIR in the same detection space (like at the same room). 444 444 452 + 445 445 = 3. Sensors and Accessories = 446 446 447 447 == 3.1 E2 Extension Cable == ... ... @@ -450,7 +450,7 @@ 450 450 [[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220619092222-1.png||_mstalt="429533" height="182" width="188"]][[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220619092313-2.png||_mstalt="430222" height="182" width="173"]] 451 451 452 452 453 -**1m long breakout cable for LHT65N- E5. Features:**461 +**1m long breakout cable for LHT65N-PIR. Features:** 454 454 455 455 * ((( 456 456 Use for AT Command ... ... @@ -472,6 +472,7 @@ 472 472 * AT Command via UART Connection : See [[FAQ>>||anchor="H7.FAQ"]]. 473 473 * LoRaWAN Downlink. Instruction for different platforms: See [[IoT LoRaWAN Server>>url:http://wiki.dragino.com/xwiki/bin/view/Main/]] section. 474 474 483 + 475 475 == 4.2 General Commands == 476 476 477 477 ... ... @@ -513,6 +513,7 @@ 513 513 514 514 * **Example 2**: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 515 515 525 + 516 516 === 4.3.2 Get Device Status === 517 517 518 518 ... ... @@ -567,6 +567,7 @@ 567 567 568 568 * There is no downlink command to set to Sleep mode. 569 569 580 + 570 570 === 4.3.5 Set UOA (Uplink on Activity) === 571 571 572 572 ... ... @@ -608,6 +608,7 @@ 608 608 * (Recommanded way) OTA firmware update via wireless: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/]] 609 609 * Update through UART TTL interface. **[[Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware]]**. 610 610 622 + 611 611 = 7. FAQ = 612 612 613 613 == 7.1 How to use AT Command? == ... ... @@ -623,12 +623,11 @@ 623 623 [[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@1655802313617-381.png||_mstalt="293917"]] 624 624 625 625 626 -In PC, User needs to set serial tool(such as [[**putty**>>https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to (% style="color:green" %)**9600** (%%)to access to access serial console for LHT65N- E5. The AT commands are disable by default and need to enter password (default:(% style="color:green" %)**123456**(% style="color:red" %))(%%) to active it. Timeout to input AT Command is 5 min, after 5-minute, user need to input password again. User can use AT+DISAT command to disable AT command before timeout.638 +In PC, User needs to set serial tool(such as [[**putty**>>https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to (% style="color:green" %)**9600** (%%)to access to access serial console for LHT65N-PIR. The AT commands are disable by default and need to enter password (default:(% style="color:green" %)**123456**(% style="color:red" %))(%%) to active it. Timeout to input AT Command is 5 min, after 5-minute, user need to input password again. User can use AT+DISAT command to disable AT command before timeout. 627 627 628 628 [[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615154519-3.png||_mstalt="431925" height="672" width="807"]] 629 629 630 630 631 - 632 632 == 7.2 Where to use AT commands and Downlink commands == 633 633 634 634 ... ... @@ -734,6 +734,7 @@ 734 734 * (% style="color:#4f81bd" %)** **(% _mstmutation="1" style="color:red" %)**IN865**(%%): LoRaWAN IN865 band 735 735 * (% style="color:#4f81bd" %)** **(% _mstmutation="1" style="color:red" %)**CN470**(%%): LoRaWAN CN470 band 736 736 748 + 737 737 = 9. Packing Info = 738 738 739 739 ... ... @@ -746,11 +746,13 @@ 746 746 * Device Size: 10 x 10 x 3.5 mm 747 747 * Device Weight: 120.5g 748 748 761 + 749 749 = 10. Reference material = 750 750 751 751 752 752 * [[Datasheet, photos, decoder, firmware>>https://www.dropbox.com/sh/una19zsni308dme/AACOKp6J2RF5TMlKWT5zU3RTa?dl=0]] 753 753 767 + 754 754 = 11. FCC Warning = 755 755 756 756
- LHT65N-PIR1.jpg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ellie - Size
-
... ... @@ -1,0 +1,1 @@ 1 +47.3 KB - Content