Last modified by Xiaoling on 2025/06/10 09:17

From version 27.1
edited by Ellie Zhang
on 2023/04/25 13:50
Change comment: Uploaded new attachment "add application1.png", version {1}
To version 15.1
edited by Edwin Chen
on 2023/04/09 09:02
Change comment: There is no comment for this version

Summary

Details

Page properties
Title
... ... @@ -1,1 +1,1 @@
1 -LHT65N-PIR Temperature/Humidity/PIR Motion Sensor User Manual
1 +LHT65-PIR Temperature/Humidity/PIR Sensor User Manual
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Ellie
1 +XWiki.Edwin
Content
... ... @@ -156,73 +156,8 @@
156 156  [[image:image-20220522233300-8.png||_mstalt="428389" height="219" width="722"]]
157 157  
158 158  
159 -== 2.4 Uplink Payload~-~-Device Status, (Fport~=5) ==
159 +== 2.4 Uplink Payload   ( Fport~=2) ==
160 160  
161 -Users can use the downlink command(**0x26 01**) to ask LHT65N-PIR to send device configure detail, include device configure status. LHT65N-PIR will uplink a payload via FPort=5 to server.
162 -
163 -The Payload format is as below.
164 -
165 -|(% colspan="6" %)**Device Status (FPORT=5)**
166 -|**Size (bytes)**|**1**|**2**|**1**|**1**|**2**
167 -|**Value**|Sensor Model|Firmware Version|Frequency Band|Sub-band|BAT
168 -
169 -Example parse in TTNv3
170 -
171 -[[image:1675144504430-490.png]]
172 -
173 -**Sensor Model**: For LHT65N-PIR, this value is 0x1A
174 -
175 -**Firmware Version**: 0x0100, Means: v1.0.0 version
176 -
177 -**Frequency Band**:
178 -
179 -*0x01: EU868
180 -
181 -*0x02: US915
182 -
183 -*0x03: IN865
184 -
185 -*0x04: AU915
186 -
187 -*0x05: KZ865
188 -
189 -*0x06: RU864
190 -
191 -*0x07: AS923
192 -
193 -*0x08: AS923-1
194 -
195 -*0x09: AS923-2
196 -
197 -*0x0a: AS923-3
198 -
199 -*0x0b: CN470
200 -
201 -*0x0c: EU433
202 -
203 -*0x0d: KR920
204 -
205 -*0x0e: MA869
206 -
207 -**Sub-Band**:
208 -
209 -AU915 and US915:value 0x00 ~~ 0x08
210 -
211 -CN470: value 0x0B ~~ 0x0C
212 -
213 -Other Bands: Always 0x00
214 -
215 -**Battery Info**:
216 -
217 -Check the battery voltage.
218 -
219 -Ex1: 0x0B45 = 2885mV
220 -
221 -Ex2: 0x0B49 = 2889mV
222 -
223 -
224 -== 2.5 Uplink Payload, Sensor Data  ( Fport~=2) ==
225 -
226 226  The uplink payload includes totally 11 bytes. Uplink packets use FPORT=2 and (% style="color:#4f81bd" %)**every 20 minutes**(%%) send one uplink by default.
227 227  
228 228  After each uplink, the (% style="color:blue" %)**BLUE LED**(%%) will blink once.
... ... @@ -264,7 +264,7 @@
264 264  * The 8^^th^^ byte: Alarm Bit (if this uplink is from periodically or movement)
265 265  * The 9^^th^^ ~~ 11^^st^^  byte: Movement Detect Count.
266 266  
267 -=== 2.5.1 Decoder in TTN V3 ===
202 +=== 2.4.1 Decoder in TTN V3 ===
268 268  
269 269  
270 270  When the uplink payload arrives TTNv3, it shows HEX format and not friendly to read. We can add LHT65N-PIR decoder in TTNv3 for friendly reading.
... ... @@ -275,7 +275,7 @@
275 275  [[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220522234118-10.png||_mstalt="451464" height="353" width="729"]]
276 276  
277 277  
278 -=== 2.5.2 BAT-Battery Info ===
213 +=== 2.4.2 BAT-Battery Info ===
279 279  
280 280  
281 281  These two bytes of BAT include the battery state and the actually voltage
... ... @@ -291,7 +291,7 @@
291 291  * BAT status=(0xcba4>>14)&0xFF=11(B),very good
292 292  * Battery Voltage =0xCBF6&0x3FFF=0x0BA4=2980mV
293 293  
294 -=== 2.5.3 Built-in Temperature ===
229 +=== 2.4.3 Built-in Temperature ===
295 295  
296 296  [[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220522235639-2.png||_mstalt="431756" height="138" width="722"]]
297 297  
... ... @@ -301,20 +301,20 @@
301 301  
302 302  * Temperature:  (0xF5C6-65536)/100=-26.18℃
303 303  
304 -=== 2.5.4 Built-in Humidity ===
239 +=== 2.4.4 Built-in Humidity ===
305 305  
306 306  [[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220522235639-4.png||_mstalt="432484" height="138" width="722"]]
307 307  
308 308  * Humidity:    0x025C/10=60.4%
309 309  
310 -=== 2.5.5 Ext value ===
245 +=== 2.4.5 Ext value ===
311 311  
312 -==== 2.5.5.1 Ext~=0x0A, PIR Sensor ====
247 +==== 2.4.5.1 Ext~=0x0A, PIR Sensor ====
313 313  
314 314  [[image:image-20221224161634-2.png||height="138" width="851"]]
315 315  
316 316  
317 -==== 2.5.5.2 Ext Value ====
252 +==== 2.4.5.2 Ext Value ====
318 318  
319 319  There are 4 bytes in Ext Value field.
320 320  
... ... @@ -348,7 +348,7 @@
348 348  0x00 E5 09 : Total detect 58633 activity since end node start.
349 349  
350 350  
351 -== 2.6 Show data on Datacake ==
286 +== 2.5 Show data on Datacake ==
352 352  
353 353  Datacake IoT platform provides a human-friendly interface to show the sensor data, once we have sensor data in TTN V3, we can use Datacake to connect to TTN V3 and see the data in Datacake. Below are the steps:
354 354  
... ... @@ -378,7 +378,7 @@
378 378  
379 379  
380 380  
381 -== 2.7 LED Indicator ==
316 +== 2.8 LED Indicator ==
382 382  
383 383  
384 384  The LHT65N-PIR has a triple color LED which for easy showing different stage .
... ... @@ -392,24 +392,14 @@
392 392  * RED LED when external sensor is not connected
393 393  * For each success downlink, the PURPLE LED will blink once
394 394  
395 -== 2.8 installation ==
330 +== 2.9 installation ==
396 396  
397 -~1. Don't install LHT65N-PIR outdoor or place where will get wet.
332 +~1. Don't install LHT65N-PIR outdoor or place where will get wet
398 398  
399 -2. Towards the PIR probe to the place where need to monitor activity. Below is the detect beam.
334 +2. Towards the PIR probe to the place where need to monitor activity.
400 400  
401 -Stable distance is 0~~3m. Some motion might not detected between 3~~5 m.
402 402  
403 -[[image:image-20230411135341-1.png||height="450" width="456"]]
404 404  
405 -**Notice: PIR can only detect motion activity, not to use to detect static people case.**
406 -
407 -* 1. PIR Motion Detector should not be installed near the Air conditioner places where with cold wind or hot wind flow, because PIR motion detector is sensitive with the temperature changes of the environment. Environment changes quickly will cause a false alarm.
408 -* 2. PIR should not be installed facing the glass window, facing glass window will be interfered by the outside sunlight and moving objects (people or vehicle). The infrared energy can penetrate the glass window.
409 -* 3. PIR should not be installed facing the moving objects or background changing objects, movement object will cause airflow change, it may cause false alarm.
410 -* 4. Between the detection range of PIR Motion detector, there is should be less objects.  Many objects may reduce the sensitive of detection range.
411 -* 5. Do not install more than one (2 or above) Wireless PIR in the same detection space (like at the same room).
412 -
413 413  = 3. Sensors and Accessories =
414 414  
415 415  == 3.1 E2 Extension Cable ==
... ... @@ -430,38 +430,56 @@
430 430  [[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220619092421-3.png||_mstalt="430547" height="371" width="529"]]
431 431  
432 432  
433 -= 4. Configure LHT65N-PIR =
358 += 4. Configure LHT65N-PIR via AT command or LoRaWAN downlink =
434 434  
435 -== 4.1 Configure Methods: ==
436 436  
361 +(((
362 +Use can configure LHT65N-E5 via AT Command or LoRaWAN Downlink.
363 +)))
437 437  
438 -LHT65N-PIR supports below configure method:
365 +* (((
366 +AT Command Connection: See [[FAQ>>||anchor="H6.FAQ"]].
367 +)))
439 439  
440 -* AT Command via UART Connection : See [[FAQ>>path:#H7.FAQ]].
441 -* LoRaWAN Downlink.  Instruction for different platforms: See [[IoT LoRaWAN Server>>url:http://wiki.dragino.com/xwiki/bin/view/Main/]] section.
369 +* (((
370 +LoRaWAN Downlink instruction for different platforms: [[IoT LoRaWAN Server>>doc:Main.WebHome]]
371 +)))
442 442  
443 -== 4.2 General Commands ==
373 +(((
374 +There are two kinds of commands to configure LHT65N-E5, they are:
375 +)))
444 444  
377 +* (((
378 +(% style="color:#4f81bd" %)**General Commands**.
379 +)))
445 445  
381 +(((
446 446  These commands are to configure:
383 +)))
447 447  
448 -* General system settings like: uplink interval.
449 -* LoRaWAN protocol & radio related command.
385 +1. (((
386 +General system settings like: uplink interval.
387 +)))
388 +1. (((
389 +LoRaWAN protocol & radio-related commands.
390 +)))
450 450  
451 -They are same for all Dragino Devices which support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki:
392 +(((
393 +They are the same for all Dragino Devices which supports DLWS-005 LoRaWAN Stack(Note~*~*). These commands can be found on the wiki: [[End Device Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
394 +)))
452 452  
453 -[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]]
396 +* (((
397 +(% style="color:#4f81bd" %)**Commands special design for LHT65N-E5**
398 +)))
454 454  
400 +(((
401 +These commands are only valid for LHT65N-E5, as below:
402 +)))
455 455  
456 -== 4.3 Commands special design for LHT65N-PIR ==
457 457  
405 +== 4.1 Set Transmit Interval Time ==
458 458  
459 -These commands only valid for LHT65N-PIR, as below:
460 460  
461 -
462 -=== 4.3.1 Set Transmit Interval Time ===
463 -
464 -
465 465  Feature: Change LoRaWAN End Node Transmit Interval.
466 466  
467 467  
... ... @@ -470,7 +470,7 @@
470 470  [[image:image-20220523150701-2.png||_mstalt="427453"]]
471 471  
472 472  
473 -(% style="color:#4f81bd" %)**Downlink Payload: 0x01**
416 +(% style="color:#4f81bd" %)**Downlink Command: 0x01**
474 474  
475 475  Format: Command Code (0x01) followed by 3 bytes time value.
476 476  
... ... @@ -480,18 +480,9 @@
480 480  
481 481  * **Example 2**: Downlink Payload: 0100003C  ~/~/ Set Transmit Interval (TDC) = 60 seconds
482 482  
483 -=== 4.3.2 Get Device Status ===
426 +== 4.2 Currently only supports E5 ==
484 484  
485 -Send a LoRaWAN downlink to ask device send Alarm settings.
486 486  
487 -* (% style="color:#4f81bd" %)**Downlink Payload**(%%)**:  **0x26 01
488 -
489 -Sensor will upload Device Status via FPORT=5. See payload section for detail.
490 -
491 -
492 -=== 4.3.3 Set Password ===
493 -
494 -
495 495  Feature: Set device password, max 9 digits
496 496  
497 497  
... ... @@ -515,7 +515,7 @@
515 515  
516 516  * 0xA205: Set external sensor type to E5
517 517  
518 -=== 4.3.4 Set to sleep mode ===
452 +== 4.3 Set to sleep mode ==
519 519  
520 520  
521 521  Feature: Set device to sleep mode
... ... @@ -532,70 +532,178 @@
532 532  
533 533  * There is no downlink command to set to Sleep mode.
534 534  
535 -=== 4.3.5 Set UOA (Uplink on Activity) ===
536 536  
537 -Feature: Enable / Disable Uplink on Activity
470 += 5. Battery & Power Consumption =
538 538  
539 -* **AT+UOA=0**  : Disable UoA
540 -* **AT+UOA=1,2** :  Enable UoA , Calm Down Time: 2 minutes. If device already send a uplink on activity, it will not send another uplink on activiy in 2 minutes, even detect activity.
472 +LHT65N-PIR use **CR17450** battery pack. See below link for detail information about the battery info and how to replace.
541 541  
542 -Notice: Calm Down time range is 1 ~~ 65535 minutes. If user set Calm Down time to low value, such as 1 minute, the sensor might send uplink very frequenctly and battery drain fast.
474 +[[**Battery Info & Power Consumption Analyze**>>url:http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20calculate%20the%20battery%20life%20of%20Dragino%20sensors%3F/]] .
543 543  
544 -(% style="color:#4f81bd" %)**AT Command: AT+UOA**
545 545  
477 += 6. OTA firmware update =
546 546  
547 -(% style="color:#4f81bd" %)**Downlink Command:  **(% class="mark" %)**xxxxxxx**
479 +Please see this link for how to do OTA firmware update[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/]]
548 548  
549 549  
550 -= 5. Battery & Power Consumption =
482 += 6. FAQ =
551 551  
552 -LHT65N-PIR use **CR17450** battery pack. See below link for detail information about the battery info and how to replace.
484 +== 6.1 How to use AT Command? ==
553 553  
554 -[[**Battery Info & Power Consumption Analyze**>>url:http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20calculate%20the%20battery%20life%20of%20Dragino%20sensors%3F/]] .
555 555  
487 +LHT65N-E5 supports AT Command set.User can use a USB to TTL adapter plus the Program Cable to connect to LHT65 for using AT command, as below.
556 556  
557 -= 6. OTA firmware update =
558 558  
559 -User can change firmware S31x-LB to:
490 +[[image:image-20220615153355-1.png||_mstalt="430222"]]
560 560  
561 -* Change Frequency band/ region.
562 -* Update with new features.
563 -* Fix bugs.
564 564  
565 -Firmware and changelog can be downloaded from : **[[Firmware download link>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/]]**
566 566  
567 -Methods to Update Firmware:
494 +[[image:1655802313617-381.png||_mstalt="293917"]]
568 568  
569 -* (Recommanded way) OTA firmware update via wireless: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/]]
570 -* Update through UART TTL interface. **[[Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware]]**.
571 571  
572 -= 7. FAQ =
573 573  
574 -== 7.1 How to use AT Command? ==
498 +(((
499 +In PC, User needs to set serial tool(such as [[**putty**>>https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to (% style="color:green" %)**9600** (%%)to access to access serial console for LHT65N-E5. The AT commands are disable by default and need to enter password (default:(% style="color:green" %)**123456**(% style="color:red" %))(%%) to active it. Timeout to input AT Command is 5 min, after 5-minute, user need to input password again. User can use AT+DISAT command to disable AT command before timeout.
500 +)))
575 575  
502 +[[image:image-20220615154519-3.png||_mstalt="431925" height="672" width="807"]]
576 576  
577 -LHT65N-E5 supports AT Command set.User can use a USB to TTL adapter plus the Program Cable to connect to LHT65 for using AT command, as below.
504 +AT Command List is as below:
578 578  
506 +AT+<CMD>? :  Help on <CMD>
579 579  
580 -[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615153355-1.png||_mstalt="430222"]]
508 +AT+<CMD> Run <CMD>
581 581  
510 +AT+<CMD>=<value> :  Set the value
582 582  
512 +AT+<CMD>=? :  Get the value
583 583  
584 -[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@1655802313617-381.png||_mstalt="293917"]]
514 +AT+DEBUG:  Set more info output
585 585  
516 +ATZ:  Trig a reset of the MCU
586 586  
587 -In PC, User needs to set serial tool(such as [[**putty**>>https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to (% style="color:green" %)**9600** (%%)to access to access serial console for LHT65N-E5. The AT commands are disable by default and need to enter password (default:(% style="color:green" %)**123456**(% style="color:red" %))(%%) to active it. Timeout to input AT Command is 5 min, after 5-minute, user need to input password again. User can use AT+DISAT command to disable AT command before timeout.
518 +AT+FDR:  Reset Parameters to Factory Default, Keys Reserve
588 588  
589 -[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615154519-3.png||_mstalt="431925" height="672" width="807"]]
520 +AT+DEUI:  Get or Set the Device EUI
590 590  
522 +AT+DADDR:  Get or Set the Device Address
591 591  
524 +AT+APPKEY:  Get or Set the Application Key
592 592  
593 -== 7.2 Where to use AT commands and Downlink commands ==
526 +AT+NWKSKEY:  Get or Set the Network Session Key
594 594  
528 +AT+APPSKEY:  Get or Set the Application Session Key
595 595  
530 +AT+APPEUI:  Get or Set the Application EUI
531 +
532 +AT+ADR:  Get or Set the Adaptive Data Rate setting. (0: off, 1: on)
533 +
534 +AT+TXP:  Get or Set the Transmit Power (0-5, MAX:0, MIN:5, according to LoRaWAN Spec)
535 +
536 +AT+DR:  Get or Set the Data Rate. (0-7 corresponding to DR_X)
537 +
538 +AT+DCS:  Get or Set the ETSI Duty Cycle setting - 0=disable, 1=enable - Only for testing
539 +
540 +AT+PNM:  Get or Set the public network mode. (0: off, 1: on)
541 +
542 +AT+RX2FQ:  Get or Set the Rx2 window frequency
543 +
544 +AT+RX2DR:  Get or Set the Rx2 window data rate (0-7 corresponding to DR_X)
545 +
546 +AT+RX1DL:  Get or Set the delay between the end of the Tx and the Rx Window 1 in ms
547 +
548 +AT+RX2DL:  Get or Set the delay between the end of the Tx and the Rx Window 2 in ms
549 +
550 +AT+JN1DL:  Get or Set the Join Accept Delay between the end of the Tx and the Join Rx Window 1 in ms
551 +
552 +AT+JN2DL:  Get or Set the Join Accept Delay between the end of the Tx and the Join Rx Window 2 in ms
553 +
554 +AT+NJM:  Get or Set the Network Join Mode. (0: ABP, 1: OTAA)
555 +
556 +AT+NWKID:  Get or Set the Network ID
557 +
558 +AT+FCU:  Get or Set the Frame Counter Uplink
559 +
560 +AT+FCD:  Get or Set the Frame Counter Downlink
561 +
562 +AT+CLASS:  Get or Set the Device Class
563 +
564 +AT+JOIN:  Join network
565 +
566 +AT+NJS:  Get the join status
567 +
568 +AT+SENDB:  Send hexadecimal data along with the application port
569 +
570 +AT+SEND:  Send text data along with the application port
571 +
572 +AT+RECVB:  Print last received data in binary format (with hexadecimal values)
573 +
574 +AT+RECV:  Print last received data in raw format
575 +
576 +AT+VER:  Get current image version and Frequency Band
577 +
578 +AT+CFM:  Get or Set the confirmation mode (0-1)
579 +
580 +AT+CFS:  Get confirmation status of the last AT+SEND (0-1)
581 +
582 +AT+SNR:  Get the SNR of the last received packet
583 +
584 +AT+RSSI:  Get the RSSI of the last received packet
585 +
586 +AT+TDC:  Get or set the application data transmission interval in ms
587 +
588 +AT+PORT:  Get or set the application port
589 +
590 +AT+DISAT:  Disable AT commands
591 +
592 +AT+PWORD: Set password, max 9 digits
593 +
594 +AT+CHS:  Get or Set Frequency (Unit: Hz) for Single Channel Mode
595 +
596 +AT+CHE:  Get or Set eight channels mode,Only for US915,AU915,CN470
597 +
598 +AT+PDTA:  Print the sector data from start page to stop page
599 +
600 +AT+PLDTA:  Print the last few sets of data
601 +
602 +AT+CLRDTA:  Clear the storage, record position back to 1st
603 +
604 +AT+SLEEP:  Set sleep mode
605 +
606 +AT+EXT:  Get or Set external sensor model
607 +
608 +AT+BAT:  Get the current battery voltage in mV
609 +
610 +AT+CFG:  Print all configurations
611 +
612 +AT+WMOD:  Get or Set Work Mode
613 +
614 +AT+ARTEMP:  Get or set the internal Temperature sensor alarm range
615 +
616 +AT+CITEMP:  Get or set the internal Temperature sensor collection interval in min
617 +
618 +AT+SETCNT:  Set the count at present
619 +
620 +AT+RJTDC:  Get or set the ReJoin data transmission interval in min
621 +
622 +AT+RPL:  Get or set response level
623 +
624 +AT+TIMESTAMP:  Get or Set UNIX timestamp in second
625 +
626 +AT+LEAPSEC:  Get or Set Leap Second
627 +
628 +AT+SYNCMOD:  Get or Set time synchronization method
629 +
630 +AT+SYNCTDC:  Get or set time synchronization interval in day
631 +
632 +AT+PID:  Get or set the PID
633 +
634 +
635 +== 6.2 Where to use AT commands and Downlink commands ==
636 +
637 +
596 596  **AT commands:**
597 597  
598 -[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220620153708-1.png||_mstalt="429806" height="603" width="723"]]
640 +[[image:image-20220620153708-1.png||_mstalt="429806" height="603" width="723"]]
599 599  
600 600  
601 601  **Downlink commands:**
... ... @@ -604,13 +604,13 @@
604 604  
605 605  (% style="color:blue" %)**TTN:**
606 606  
607 -[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615092124-2.png||_mstalt="429221" height="649" width="688"]]
649 +[[image:image-20220615092124-2.png||_mstalt="429221" height="649" width="688"]]
608 608  
609 609  
610 610  
611 611  (% style="color:blue" %)**Helium:**
612 612  
613 -[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615092551-3.png||_mstalt="430794" height="423" width="835"]]
655 +[[image:image-20220615092551-3.png||_mstalt="430794" height="423" width="835"]]
614 614  
615 615  
616 616  
... ... @@ -617,49 +617,56 @@
617 617  (% style="color:blue" %)**Chirpstack: The downlink window will not be displayed until the network is accessed**
618 618  
619 619  
620 -[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615094850-6.png||_mstalt="433082"]]
662 +[[image:image-20220615094850-6.png||_mstalt="433082"]]
621 621  
622 622  
623 -[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615094904-7.png||_mstalt="433485" height="281" width="911"]]
665 +[[image:image-20220615094904-7.png||_mstalt="433485" height="281" width="911"]]
624 624  
625 625  
626 626  
627 627  (% style="color:blue" %)**Aws:**
628 628  
629 -[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615092939-4.png||_mstalt="434460" height="448" width="894"]]
671 +[[image:image-20220615092939-4.png||_mstalt="434460" height="448" width="894"]]
630 630  
631 631  
632 -== 7.3 How to change the uplink interval? ==
674 +== 6.3 How to change the uplink interval? ==
633 633  
676 +
634 634  Please see this link: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/How%20to%20set%20the%20transmit%20time%20interval/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20set%20the%20transmit%20time%20interval/||_mstmutation="1" style="background-color: rgb(255, 255, 255);"]]
635 635  
636 -[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615154519-3.png||_mstalt="431925" height="672" width="807"]]
637 637  
638 638  
639 -== 7.4 How to use TTL-USB to connect PC to upgrade firmware? ==
681 +[[image:image-20220615154519-3.png||_mstalt="431925" height="672" width="807"]]
640 640  
641 -[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615153355-1.png||_mstalt="430222"]]
642 642  
684 +== 6.4 How to use TTL-USB to connect PC to upgrade firmware? ==
685 +
686 +
687 +[[image:image-20220615153355-1.png||_mstalt="430222"]]
688 +
689 +
643 643  (% style="color:blue" %)**Step1**(%%): Install TremoProgrammer  first.
644 644  
645 -[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615170542-5.png||_mstalt="430638"]]
692 +[[image:image-20220615170542-5.png||_mstalt="430638"]]
646 646  
694 +
695 +
647 647  (% _mstmutation="1" style="color:blue" %)**Step2**(%%):wiring method.(% style="display:none" %)
648 648  
649 649  First connect the four lines;(% style="display:none" %)
650 650  
651 -[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220621170938-1.png||_mstalt="431340" height="413" width="419"]],(% style="display:none" %)
700 +[[image:image-20220621170938-1.png||_mstalt="431340" height="413" width="419"]],(% style="display:none" %)
652 652  
653 653  
654 654  Then use DuPont cable to short circuit port3 and port1, and then release them, so that the device enters bootlaod mode.
655 655  
656 -[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220621170938-2.png||_mstalt="431704"]]
705 +[[image:image-20220621170938-2.png||_mstalt="431704"]]
657 657  
658 658  
659 659  
660 660  (% style="color:blue" %)**Step3:**(%%)Select the device port to be connected, baud rate and bin file to be downloaded.
661 661  
662 -[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615171334-6.png||_mstalt="431028"]]
711 +[[image:image-20220615171334-6.png||_mstalt="431028"]]
663 663  
664 664  
665 665  Click the (% style="color:blue" %)**start**(%%) button to start the firmware upgrade.
... ... @@ -667,7 +667,7 @@
667 667  
668 668  When this interface appears, it indicates that the download has been completed.
669 669  
670 -[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220620160723-8.png||_mstalt="430703"]]
719 +[[image:image-20220620160723-8.png||_mstalt="430703"]]
671 671  
672 672  
673 673  Finally, unplug the DuPont cable on port4, and then use the DuPont cable to short circuit port3 and port1 to reset the device.
... ... @@ -674,10 +674,10 @@
674 674  
675 675  
676 676  
677 -[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615154519-3.png||_mstalt="431925" height="672" width="807"]]
726 +[[image:image-20220615154519-3.png||_mstalt="431925" height="672" width="807"]]
678 678  
679 679  
680 -= 8. Order Info =
729 += 7. Order Info =
681 681  
682 682  
683 683  Part Number: (% style="color:#4f81bd" %)** LHT65N-PIR-XX**
... ... @@ -693,7 +693,7 @@
693 693  * (% style="color:#4f81bd" %)** **(% _mstmutation="1" style="color:red" %)**IN865**(%%): LoRaWAN IN865 band
694 694  * (% style="color:#4f81bd" %)** **(% _mstmutation="1" style="color:red" %)**CN470**(%%): LoRaWAN CN470 band
695 695  
696 -= 9. Packing Info =
745 += 8. Packing Info =
697 697  
698 698  
699 699  **Package Includes**:
... ... @@ -705,12 +705,12 @@
705 705  * Device Size:  10 x 10 x 3.5 mm
706 706  * Device Weight: 120.5g
707 707  
708 -= 10. Reference material =
757 += 9. Reference material =
709 709  
710 710  
711 711  * [[Datasheet, photos, decoder, firmware>>https://www.dropbox.com/sh/una19zsni308dme/AACOKp6J2RF5TMlKWT5zU3RTa?dl=0]]
712 712  
713 -= 11. FCC Warning =
762 += 10. FCC Warning =
714 714  
715 715  
716 716  This device complies with part 15 of the FCC Rules.Operation is subject to the following two conditions:
add application1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ellie
Size
... ... @@ -1,1 +1,0 @@
1 -44.5 KB
Content
image-20230411114550-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Edwin
Size
... ... @@ -1,1 +1,0 @@
1 -268.1 KB
Content
image-20230411135341-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Edwin
Size
... ... @@ -1,1 +1,0 @@
1 -113.6 KB
Content
shipped.jpeg
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ellie
Size
... ... @@ -1,1 +1,0 @@
1 -16.5 KB
Content