From version < 17.1 >
edited by Edwin Chen
on 2023/04/09 09:32
To version < 18.1 >
edited by Edwin Chen
on 2023/04/09 09:36
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -156,8 +156,73 @@
156 156  [[image:image-20220522233300-8.png||_mstalt="428389" height="219" width="722"]]
157 157  
158 158  
159 -== 2.4 Uplink Payload   ( Fport~=2) ==
159 +== 2.4 Uplink Payload~-~-Device Status, FPORT~=5 ==
160 160  
161 +Users can use the downlink command(**0x26 01**) to ask LHT65N-PIR to send device configure detail, include device configure status. LHT65N-PIR will uplink a payload via FPort=5 to server.
162 +
163 +The Payload format is as below.
164 +
165 +|(% colspan="6" %)**Device Status (FPORT=5)**
166 +|**Size (bytes)**|**1**|**2**|**1**|**1**|**2**
167 +|**Value**|Sensor Model|Firmware Version|Frequency Band|Sub-band|BAT
168 +
169 +Example parse in TTNv3
170 +
171 +[[image:1675144504430-490.png]]
172 +
173 +**Sensor Model**: For LHT65N-PIR, this value is 0x1A
174 +
175 +**Firmware Version**: 0x0100, Means: v1.0.0 version
176 +
177 +**Frequency Band**:
178 +
179 +*0x01: EU868
180 +
181 +*0x02: US915
182 +
183 +*0x03: IN865
184 +
185 +*0x04: AU915
186 +
187 +*0x05: KZ865
188 +
189 +*0x06: RU864
190 +
191 +*0x07: AS923
192 +
193 +*0x08: AS923-1
194 +
195 +*0x09: AS923-2
196 +
197 +*0x0a: AS923-3
198 +
199 +*0x0b: CN470
200 +
201 +*0x0c: EU433
202 +
203 +*0x0d: KR920
204 +
205 +*0x0e: MA869
206 +
207 +**Sub-Band**:
208 +
209 +AU915 and US915:value 0x00 ~~ 0x08
210 +
211 +CN470: value 0x0B ~~ 0x0C
212 +
213 +Other Bands: Always 0x00
214 +
215 +**Battery Info**:
216 +
217 +Check the battery voltage.
218 +
219 +Ex1: 0x0B45 = 2885mV
220 +
221 +Ex2: 0x0B49 = 2889mV
222 +
223 +
224 +== 2.5 Uplink Payload, Sensor Data  ( Fport~=2) ==
225 +
161 161  The uplink payload includes totally 11 bytes. Uplink packets use FPORT=2 and (% style="color:#4f81bd" %)**every 20 minutes**(%%) send one uplink by default.
162 162  
163 163  After each uplink, the (% style="color:blue" %)**BLUE LED**(%%) will blink once.
... ... @@ -199,7 +199,7 @@
199 199  * The 8^^th^^ byte: Alarm Bit (if this uplink is from periodically or movement)
200 200  * The 9^^th^^ ~~ 11^^st^^  byte: Movement Detect Count.
201 201  
202 -=== 2.4.1 Decoder in TTN V3 ===
267 +=== 2.5.1 Decoder in TTN V3 ===
203 203  
204 204  
205 205  When the uplink payload arrives TTNv3, it shows HEX format and not friendly to read. We can add LHT65N-PIR decoder in TTNv3 for friendly reading.
... ... @@ -210,7 +210,7 @@
210 210  [[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220522234118-10.png||_mstalt="451464" height="353" width="729"]]
211 211  
212 212  
213 -=== 2.4.2 BAT-Battery Info ===
278 +=== 2.5.2 BAT-Battery Info ===
214 214  
215 215  
216 216  These two bytes of BAT include the battery state and the actually voltage
... ... @@ -226,7 +226,7 @@
226 226  * BAT status=(0xcba4>>14)&0xFF=11(B),very good
227 227  * Battery Voltage =0xCBF6&0x3FFF=0x0BA4=2980mV
228 228  
229 -=== 2.4.3 Built-in Temperature ===
294 +=== 2.5.3 Built-in Temperature ===
230 230  
231 231  [[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220522235639-2.png||_mstalt="431756" height="138" width="722"]]
232 232  
... ... @@ -236,20 +236,21 @@
236 236  
237 237  * Temperature:  (0xF5C6-65536)/100=-26.18℃
238 238  
239 -=== 2.4.4 Built-in Humidity ===
304 +=== 2.5.4 Built-in Humidity ===
240 240  
241 241  [[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220522235639-4.png||_mstalt="432484" height="138" width="722"]]
242 242  
243 243  * Humidity:    0x025C/10=60.4%
244 244  
245 -=== 2.4.5 Ext value ===
246 246  
247 -==== 2.4.5.1 Ext~=0x0A, PIR Sensor ====
311 +=== 2.5.5 Ext value ===
248 248  
313 +==== 2.5.5.1 Ext~=0x0A, PIR Sensor ====
314 +
249 249  [[image:image-20221224161634-2.png||height="138" width="851"]]
250 250  
251 251  
252 -==== 2.4.5.2 Ext Value ====
318 +==== 2.5.5.2 Ext Value ====
253 253  
254 254  There are 4 bytes in Ext Value field.
255 255  
... ... @@ -283,7 +283,7 @@
283 283  0x00 E5 09 : Total detect 58633 activity since end node start.
284 284  
285 285  
286 -== 2.5 Show data on Datacake ==
352 +== 2.6 Show data on Datacake ==
287 287  
288 288  Datacake IoT platform provides a human-friendly interface to show the sensor data, once we have sensor data in TTN V3, we can use Datacake to connect to TTN V3 and see the data in Datacake. Below are the steps:
289 289  
... ... @@ -313,7 +313,7 @@
313 313  
314 314  
315 315  
316 -== 2.8 LED Indicator ==
382 +== 2.7 LED Indicator ==
317 317  
318 318  
319 319  The LHT65N-PIR has a triple color LED which for easy showing different stage .
... ... @@ -327,7 +327,7 @@
327 327  * RED LED when external sensor is not connected
328 328  * For each success downlink, the PURPLE LED will blink once
329 329  
330 -== 2.9 installation ==
396 +== 2.8 installation ==
331 331  
332 332  ~1. Don't install LHT65N-PIR outdoor or place where will get wet
333 333  
... ... @@ -365,7 +365,6 @@
365 365  * AT Command via UART Connection : See [[FAQ>>path:#H7.FAQ]].
366 366  * LoRaWAN Downlink.  Instruction for different platforms: See [[IoT LoRaWAN Server>>url:http://wiki.dragino.com/xwiki/bin/view/Main/]] section.
367 367  
368 -
369 369  == 4.2 General Commands ==
370 370  
371 371  
... ... @@ -406,7 +406,6 @@
406 406  
407 407  * **Example 2**: Downlink Payload: 0100003C  ~/~/ Set Transmit Interval (TDC) = 60 seconds
408 408  
409 -
410 410  === 4.3.2 Get Device Status ===
411 411  
412 412  Send a LoRaWAN downlink to ask device send Alarm settings.
... ... @@ -442,7 +442,6 @@
442 442  
443 443  * 0xA205: Set external sensor type to E5
444 444  
445 -
446 446  === 4.3.4 Set to sleep mode ===
447 447  
448 448  
... ... @@ -460,7 +460,6 @@
460 460  
461 461  * There is no downlink command to set to Sleep mode.
462 462  
463 -
464 464  === 4.3.5 Set UOA (Uplink on Activity) ===
465 465  
466 466  Feature: Enable / Disable Uplink on Activity
... ... @@ -468,11 +468,10 @@
468 468  * **AT+UOA=0**  : Disable UoA
469 469  * **AT+UOA=1,2** :  Enable UoA , Calm Down Time: 2 minutes. If device already send a uplink on activity, it will not send another uplink on activiy in 2 minutes, even detect activity.
470 470  
471 -
472 472  (% style="color:#4f81bd" %)**AT Command: AT+UOA**
473 473  
474 474  
475 -(% style="color:#4f81bd" %)**Downlink Command:  (% class="mark" %)xxxxxxx(%%)**
536 +(% style="color:#4f81bd" %)**Downlink Command:  **(% class="mark" %)**xxxxxxx**
476 476  
477 477  
478 478  = 5. Battery & Power Consumption =
... ... @@ -487,9 +487,9 @@
487 487  Please see this link for how to do OTA firmware update: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/]]
488 488  
489 489  
490 -= 6. FAQ =
551 += 7. FAQ =
491 491  
492 -== 6.1 How to use AT Command? ==
553 +== 7.1 How to use AT Command? ==
493 493  
494 494  
495 495  LHT65N-E5 supports AT Command set.User can use a USB to TTL adapter plus the Program Cable to connect to LHT65 for using AT command, as below.
... ... @@ -508,7 +508,7 @@
508 508  
509 509  
510 510  
511 -== 6.2 Where to use AT commands and Downlink commands ==
572 +== 7.2 Where to use AT commands and Downlink commands ==
512 512  
513 513  
514 514  **AT commands:**
... ... @@ -554,7 +554,7 @@
554 554  [[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615154519-3.png||_mstalt="431925" height="672" width="807"]]
555 555  
556 556  
557 -== 6.4 How to use TTL-USB to connect PC to upgrade firmware? ==
618 +== 7.4 How to use TTL-USB to connect PC to upgrade firmware? ==
558 558  
559 559  [[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615153355-1.png||_mstalt="430222"]]
560 560  
... ... @@ -595,7 +595,7 @@
595 595  [[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615154519-3.png||_mstalt="431925" height="672" width="807"]]
596 596  
597 597  
598 -= 7. Order Info =
659 += 8. Order Info =
599 599  
600 600  
601 601  Part Number: (% style="color:#4f81bd" %)** LHT65N-PIR-XX**
... ... @@ -611,7 +611,7 @@
611 611  * (% style="color:#4f81bd" %)** **(% _mstmutation="1" style="color:red" %)**IN865**(%%): LoRaWAN IN865 band
612 612  * (% style="color:#4f81bd" %)** **(% _mstmutation="1" style="color:red" %)**CN470**(%%): LoRaWAN CN470 band
613 613  
614 -= 8. Packing Info =
675 += 9. Packing Info =
615 615  
616 616  
617 617  **Package Includes**:
... ... @@ -623,12 +623,12 @@
623 623  * Device Size:  10 x 10 x 3.5 mm
624 624  * Device Weight: 120.5g
625 625  
626 -= 9. Reference material =
687 += 10. Reference material =
627 627  
628 628  
629 629  * [[Datasheet, photos, decoder, firmware>>https://www.dropbox.com/sh/una19zsni308dme/AACOKp6J2RF5TMlKWT5zU3RTa?dl=0]]
630 630  
631 -= 10. FCC Warning =
692 += 11. FCC Warning =
632 632  
633 633  
634 634  This device complies with part 15 of the FCC Rules.Operation is subject to the following two conditions:
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0