Changes for page LHT65N-PIR Temperature/Humidity/PIR Motion Sensor User Manual
Last modified by Xiaoling on 2025/06/10 09:17
From version 17.1
edited by Edwin Chen
on 2023/04/09 09:32
on 2023/04/09 09:32
Change comment:
There is no comment for this version
To version 16.1
edited by Edwin Chen
on 2023/04/09 09:09
on 2023/04/09 09:09
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -355,39 +355,56 @@ 355 355 [[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220619092421-3.png||_mstalt="430547" height="371" width="529"]] 356 356 357 357 358 -= 4. Configure LHT65N-PIR = 358 += 4. Configure LHT65N-PIR via AT command or LoRaWAN downlink = 359 359 360 -== 4.1 Configure Methods: == 361 361 361 +((( 362 +Use can configure LHT65N-E5 via AT Command or LoRaWAN Downlink. 363 +))) 362 362 363 -LHT65N-PIR supports below configure method: 365 +* ((( 366 +AT Command Connection: See [[FAQ>>||anchor="H6.FAQ"]]. 367 +))) 364 364 365 -* AT Command via UART Connection : See [[FAQ>>path:#H7.FAQ]]. 366 -* LoRaWAN Downlink. Instruction for different platforms: See [[IoT LoRaWAN Server>>url:http://wiki.dragino.com/xwiki/bin/view/Main/]] section. 369 +* ((( 370 +LoRaWAN Downlink instruction for different platforms: [[IoT LoRaWAN Server>>doc:Main.WebHome]] 371 +))) 367 367 373 +((( 374 +There are two kinds of commands to configure LHT65N-E5, they are: 375 +))) 368 368 369 -== 4.2 General Commands == 377 +* ((( 378 +(% style="color:#4f81bd" %)**General Commands**. 379 +))) 370 370 371 - 381 +((( 372 372 These commands are to configure: 383 +))) 373 373 374 -* General system settings like: uplink interval. 375 -* LoRaWAN protocol & radio related command. 385 +1. ((( 386 +General system settings like: uplink interval. 387 +))) 388 +1. ((( 389 +LoRaWAN protocol & radio-related commands. 390 +))) 376 376 377 -They are same for all Dragino Devices which support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki: 392 +((( 393 +They are the same for all Dragino Devices which supports DLWS-005 LoRaWAN Stack(Note~*~*). These commands can be found on the wiki: [[End Device Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] 394 +))) 378 378 379 -[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]] 396 +* ((( 397 +(% style="color:#4f81bd" %)**Commands special design for LHT65N-E5** 398 +))) 380 380 400 +((( 401 +These commands are only valid for LHT65N-E5, as below: 402 +))) 381 381 382 -== 4.3 Commands special design for LHT65N-PIR == 383 383 405 +== 4.1 Set Transmit Interval Time == 384 384 385 -These commands only valid for LHT65N-PIR, as below: 386 386 387 - 388 -=== 4.3.1 Set Transmit Interval Time === 389 - 390 - 391 391 Feature: Change LoRaWAN End Node Transmit Interval. 392 392 393 393 ... ... @@ -396,7 +396,7 @@ 396 396 [[image:image-20220523150701-2.png||_mstalt="427453"]] 397 397 398 398 399 -(% style="color:#4f81bd" %)**Downlink Payload: 0x01**416 +(% style="color:#4f81bd" %)**Downlink Command: 0x01** 400 400 401 401 Format: Command Code (0x01) followed by 3 bytes time value. 402 402 ... ... @@ -406,19 +406,9 @@ 406 406 407 407 * **Example 2**: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 408 408 426 +== 4.2 Currently only supports E5 == 409 409 410 -=== 4.3.2 Get Device Status === 411 411 412 -Send a LoRaWAN downlink to ask device send Alarm settings. 413 - 414 -* (% style="color:#4f81bd" %)**Downlink Payload**(%%)**: **0x26 01 415 - 416 -Sensor will upload Device Status via FPORT=5. See payload section for detail. 417 - 418 - 419 -=== 4.3.3 Set Password === 420 - 421 - 422 422 Feature: Set device password, max 9 digits 423 423 424 424 ... ... @@ -442,10 +442,9 @@ 442 442 443 443 * 0xA205: Set external sensor type to E5 444 444 452 +== 4.3 Set to sleep mode == 445 445 446 -=== 4.3.4 Set to sleep mode === 447 447 448 - 449 449 Feature: Set device to sleep mode 450 450 451 451 * **AT+Sleep=0** : Normal working mode, device will sleep and use lower power when there is no LoRa message ... ... @@ -460,21 +460,6 @@ 460 460 461 461 * There is no downlink command to set to Sleep mode. 462 462 463 - 464 -=== 4.3.5 Set UOA (Uplink on Activity) === 465 - 466 -Feature: Enable / Disable Uplink on Activity 467 - 468 -* **AT+UOA=0** : Disable UoA 469 -* **AT+UOA=1,2** : Enable UoA , Calm Down Time: 2 minutes. If device already send a uplink on activity, it will not send another uplink on activiy in 2 minutes, even detect activity. 470 - 471 - 472 -(% style="color:#4f81bd" %)**AT Command: AT+UOA** 473 - 474 - 475 -(% style="color:#4f81bd" %)**Downlink Command: (% class="mark" %)xxxxxxx(%%)** 476 - 477 - 478 478 = 5. Battery & Power Consumption = 479 479 480 480 LHT65N-PIR use **CR17450** battery pack. See below link for detail information about the battery info and how to replace.