Changes for page LHT65N-PIR Temperature/Humidity/PIR Motion Sensor User Manual
Last modified by Xiaoling on 2025/06/10 09:17
From version 15.1
edited by Edwin Chen
on 2023/04/09 09:02
on 2023/04/09 09:02
Change comment:
There is no comment for this version
To version 11.1
edited by Edwin Chen
on 2023/04/09 08:40
on 2023/04/09 08:40
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -236,6 +236,7 @@ 236 236 237 237 * Temperature: (0xF5C6-65536)/100=-26.18℃ 238 238 239 + 239 239 === 2.4.4 Built-in Humidity === 240 240 241 241 [[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220522235639-4.png||_mstalt="432484" height="138" width="722"]] ... ... @@ -242,6 +242,7 @@ 242 242 243 243 * Humidity: 0x025C/10=60.4% 244 244 246 + 245 245 === 2.4.5 Ext value === 246 246 247 247 ==== 2.4.5.1 Ext~=0x0A, PIR Sensor ==== ... ... @@ -257,7 +257,7 @@ 257 257 258 258 (% border="1" cellspacing="4" style="background-color:#ffffcc; color:green; width:490px" %) 259 259 |=(% style="width: 147px;" %)((( 260 -**The 8^^th^^ byte** 262 +**The 8^^th^^ bytes** 261 261 )))|=(% style="width: 108px;" %)((( 262 262 **Bit 1~~7** 263 263 )))|=(% style="width: 228px;" %)((( ... ... @@ -293,7 +293,7 @@ 293 293 294 294 Add Datacake: 295 295 296 -[[image: Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220523000825-7.png||_mstalt="429884" height="262" width="583"]]298 +[[image:image-20220523000825-7.png||_mstalt="429884" height="262" width="583"]] 297 297 298 298 299 299 ... ... @@ -300,16 +300,16 @@ 300 300 Select default key as Access Key: 301 301 302 302 303 -[[image: Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220523000825-8.png||_mstalt="430248" height="453" width="406"]]305 +[[image:image-20220523000825-8.png||_mstalt="430248" height="453" width="406"]] 304 304 305 305 306 306 In Datacake console ([[https:~~/~~/datacake.co/>>url:https://datacake.co/]]) , add LHT65 device. 307 307 308 308 309 -[[image: Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20221224161935-5.png||height="523" width="409"]]311 +[[image:image-20221224161935-5.png||height="523" width="409"]] 310 310 311 311 312 -[[image: Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20221224161957-6.png||height="306" width="852"]]314 +[[image:image-20221224161957-6.png||height="306" width="852"]] 313 313 314 314 315 315 ... ... @@ -329,18 +329,16 @@ 329 329 330 330 == 2.9 installation == 331 331 332 -~1. Don't install LHT65N-PIR outdoor or place where will get wet 333 333 334 -2. Towardshe PIR probetotheplace where needtomonitor activity.335 +[[image:image-20220516231650-1.png||_mstalt="428597" height="436" width="428"]] 335 335 336 336 337 - 338 338 = 3. Sensors and Accessories = 339 339 340 340 == 3.1 E2 Extension Cable == 341 341 342 342 343 -[[image: Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220619092222-1.png||_mstalt="429533" height="182" width="188"]][[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220619092313-2.png||_mstalt="430222" height="182" width="173"]]343 +[[image:image-20220619092222-1.png||_mstalt="429533" height="182" width="188"]][[image:image-20220619092313-2.png||_mstalt="430222" height="182" width="173"]] 344 344 345 345 346 346 **1m long breakout cable for LHT65N-E5. Features:** ... ... @@ -352,7 +352,7 @@ 352 352 Update firmware for LHT65N-PIR 353 353 ))) 354 354 355 -[[image: Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220619092421-3.png||_mstalt="430547" height="371" width="529"]]355 +[[image:image-20220619092421-3.png||_mstalt="430547" height="371" width="529"]] 356 356 357 357 358 358 = 4. Configure LHT65N-PIR via AT command or LoRaWAN downlink = ... ... @@ -466,19 +466,47 @@ 466 466 467 467 * There is no downlink command to set to Sleep mode. 468 468 469 += 5. Battery & How to replace = 469 469 470 -= 5. Battery & PowerConsumption=471 +== 5.1 Battery Type == 471 471 472 -LHT65N-PIR use **CR17450** battery pack. See below link for detail information about the battery info and how to replace. 473 473 474 -[[**Battery Info & Power Consumption Analyze**>>url:http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20calculate%20the%20battery%20life%20of%20Dragino%20sensors%3F/]] . 474 +((( 475 +LHT65N-E5 is equipped with a 2400mAH Li-MnO2 (CR17505) battery . The battery is an un-rechargeable battery with low discharge rate targeting for up to 8~~10 years use. This type of battery is commonly used in IoT devices for long-term running, such as water meters. 476 +))) 475 475 478 +((( 479 +The discharge curve is not linear so can't simply use percentage to show the battery level. Below is the battery performance. 476 476 477 -= 6. OTA firmware update = 478 478 479 -Please see this link for how to do OTA firmware update: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/]] 482 +[[image:image-20220515075034-1.png||_mstalt="428961" height="208" width="644"]] 483 +))) 480 480 485 +The minimum Working Voltage for the LHT65N-E5 is ~~ 2.5v. When battery is lower than 2.6v, it is time to change the battery. 486 + 481 481 488 +== 5.2 Replace Battery == 489 + 490 + 491 +LHT65N-E5 has two screws on the back, Unscrew them, and changing the battery inside is ok. The battery is a general CR17450 battery (3.0v). Any brand should be ok. 492 + 493 +[[image:image-20220515075440-2.png||_mstalt="429546" height="338" width="272"]][[image:image-20220515075625-3.png||_mstalt="431574" height="193" width="257"]] 494 + 495 + 496 +== 5.3 Battery Life Analyze == 497 + 498 + 499 +((( 500 +Dragino battery-powered products are all run in Low Power mode. User can check the guideline from this link to calculate the estimated battery life: 501 +[[https:~~/~~/www.dragino.com/downloads/downloads/LoRa_End_Node/Battery_Analyze/DRAGINO_Battery_Life_Guide.pdf>>https://www.dragino.com/downloads/downloads/LoRa_End_Node/Battery_Analyze/DRAGINO_Battery_Life_Guide.pdf]] 502 +))) 503 + 504 + 505 +((( 506 +A full detail test report for LHT65N-E5 on different frequency can be found at : [[https:~~/~~/www.dropbox.com/sh/r2i3zlhsyrpavla/AAB1sZw3mdT0K7XjpHCITt13a?dl=0>>https://www.dropbox.com/sh/r2i3zlhsyrpavla/AAB1sZw3mdT0K7XjpHCITt13a?dl=0]] 507 +))) 508 + 509 + 482 482 = 6. FAQ = 483 483 484 484 == 6.1 How to use AT Command? ==