Changes for page LHT65N-PIR Temperature/Humidity/PIR Motion Sensor User Manual
Last modified by Xiaoling on 2025/04/24 10:00
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -156,8 +156,73 @@ 156 156 [[image:image-20220522233300-8.png||_mstalt="428389" height="219" width="722"]] 157 157 158 158 159 -== 2.4 Uplink Payload (Fport~=2)==159 +== 2.4 Uplink Payload~-~-Device Status, FPORT~=5 == 160 160 161 +Users can use the downlink command(**0x26 01**) to ask LHT65N-PIR to send device configure detail, include device configure status. LHT65N-PIR will uplink a payload via FPort=5 to server. 162 + 163 +The Payload format is as below. 164 + 165 +|(% colspan="6" %)**Device Status (FPORT=5)** 166 +|**Size (bytes)**|**1**|**2**|**1**|**1**|**2** 167 +|**Value**|Sensor Model|Firmware Version|Frequency Band|Sub-band|BAT 168 + 169 +Example parse in TTNv3 170 + 171 +[[image:1675144504430-490.png]] 172 + 173 +**Sensor Model**: For LHT65N-PIR, this value is 0x1A 174 + 175 +**Firmware Version**: 0x0100, Means: v1.0.0 version 176 + 177 +**Frequency Band**: 178 + 179 +*0x01: EU868 180 + 181 +*0x02: US915 182 + 183 +*0x03: IN865 184 + 185 +*0x04: AU915 186 + 187 +*0x05: KZ865 188 + 189 +*0x06: RU864 190 + 191 +*0x07: AS923 192 + 193 +*0x08: AS923-1 194 + 195 +*0x09: AS923-2 196 + 197 +*0x0a: AS923-3 198 + 199 +*0x0b: CN470 200 + 201 +*0x0c: EU433 202 + 203 +*0x0d: KR920 204 + 205 +*0x0e: MA869 206 + 207 +**Sub-Band**: 208 + 209 +AU915 and US915:value 0x00 ~~ 0x08 210 + 211 +CN470: value 0x0B ~~ 0x0C 212 + 213 +Other Bands: Always 0x00 214 + 215 +**Battery Info**: 216 + 217 +Check the battery voltage. 218 + 219 +Ex1: 0x0B45 = 2885mV 220 + 221 +Ex2: 0x0B49 = 2889mV 222 + 223 + 224 +== 2.5 Uplink Payload, Sensor Data ( Fport~=2) == 225 + 161 161 The uplink payload includes totally 11 bytes. Uplink packets use FPORT=2 and (% style="color:#4f81bd" %)**every 20 minutes**(%%) send one uplink by default. 162 162 163 163 After each uplink, the (% style="color:blue" %)**BLUE LED**(%%) will blink once. ... ... @@ -199,7 +199,7 @@ 199 199 * The 8^^th^^ byte: Alarm Bit (if this uplink is from periodically or movement) 200 200 * The 9^^th^^ ~~ 11^^st^^ byte: Movement Detect Count. 201 201 202 -=== 2. 4.1 Decoder in TTN V3 ===267 +=== 2.5.1 Decoder in TTN V3 === 203 203 204 204 205 205 When the uplink payload arrives TTNv3, it shows HEX format and not friendly to read. We can add LHT65N-PIR decoder in TTNv3 for friendly reading. ... ... @@ -210,7 +210,7 @@ 210 210 [[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220522234118-10.png||_mstalt="451464" height="353" width="729"]] 211 211 212 212 213 -=== 2. 4.2 BAT-Battery Info ===278 +=== 2.5.2 BAT-Battery Info === 214 214 215 215 216 216 These two bytes of BAT include the battery state and the actually voltage ... ... @@ -226,7 +226,7 @@ 226 226 * BAT status=(0xcba4>>14)&0xFF=11(B),very good 227 227 * Battery Voltage =0xCBF6&0x3FFF=0x0BA4=2980mV 228 228 229 -=== 2. 4.3 Built-in Temperature ===294 +=== 2.5.3 Built-in Temperature === 230 230 231 231 [[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220522235639-2.png||_mstalt="431756" height="138" width="722"]] 232 232 ... ... @@ -236,20 +236,21 @@ 236 236 237 237 * Temperature: (0xF5C6-65536)/100=-26.18℃ 238 238 239 -=== 2. 4.4 Built-in Humidity ===304 +=== 2.5.4 Built-in Humidity === 240 240 241 241 [[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220522235639-4.png||_mstalt="432484" height="138" width="722"]] 242 242 243 243 * Humidity: 0x025C/10=60.4% 244 244 245 -=== 2.4.5 Ext value === 246 246 247 -=== =2.4.5.1Ext~=0x0A,PIR Sensor====311 +=== 2.5.5 Ext value === 248 248 313 +==== 2.5.5.1 Ext~=0x0A, PIR Sensor ==== 314 + 249 249 [[image:image-20221224161634-2.png||height="138" width="851"]] 250 250 251 251 252 -==== 2. 4.5.2 Ext Value ====318 +==== 2.5.5.2 Ext Value ==== 253 253 254 254 There are 4 bytes in Ext Value field. 255 255 ... ... @@ -283,7 +283,7 @@ 283 283 0x00 E5 09 : Total detect 58633 activity since end node start. 284 284 285 285 286 -== 2. 5Show data on Datacake ==352 +== 2.6 Show data on Datacake == 287 287 288 288 Datacake IoT platform provides a human-friendly interface to show the sensor data, once we have sensor data in TTN V3, we can use Datacake to connect to TTN V3 and see the data in Datacake. Below are the steps: 289 289 ... ... @@ -313,7 +313,7 @@ 313 313 314 314 315 315 316 -== 2. 8LED Indicator ==382 +== 2.7 LED Indicator == 317 317 318 318 319 319 The LHT65N-PIR has a triple color LED which for easy showing different stage . ... ... @@ -327,7 +327,7 @@ 327 327 * RED LED when external sensor is not connected 328 328 * For each success downlink, the PURPLE LED will blink once 329 329 330 -== 2. 9installation ==396 +== 2.8 installation == 331 331 332 332 ~1. Don't install LHT65N-PIR outdoor or place where will get wet 333 333 ... ... @@ -355,56 +355,38 @@ 355 355 [[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220619092421-3.png||_mstalt="430547" height="371" width="529"]] 356 356 357 357 358 -= 4. Configure LHT65N-PIR via AT command or LoRaWAN downlink=424 += 4. Configure LHT65N-PIR = 359 359 426 +== 4.1 Configure Methods: == 360 360 361 -((( 362 -Use can configure LHT65N-E5 via AT Command or LoRaWAN Downlink. 363 -))) 364 364 365 -* ((( 366 -AT Command Connection: See [[FAQ>>||anchor="H6.FAQ"]]. 367 -))) 429 +LHT65N-PIR supports below configure method: 368 368 369 -* ((( 370 -LoRaWAN Downlink instruction for different platforms: [[IoT LoRaWAN Server>>doc:Main.WebHome]] 371 -))) 431 +* AT Command via UART Connection : See [[FAQ>>path:#H7.FAQ]]. 432 +* LoRaWAN Downlink. Instruction for different platforms: See [[IoT LoRaWAN Server>>url:http://wiki.dragino.com/xwiki/bin/view/Main/]] section. 372 372 373 -((( 374 -There are two kinds of commands to configure LHT65N-E5, they are: 375 -))) 434 +== 4.2 General Commands == 376 376 377 -* ((( 378 -(% style="color:#4f81bd" %)**General Commands**. 379 -))) 380 380 381 -((( 382 382 These commands are to configure: 383 -))) 384 384 385 -1. ((( 386 -General system settings like: uplink interval. 387 -))) 388 -1. ((( 389 -LoRaWAN protocol & radio-related commands. 390 -))) 439 +* General system settings like: uplink interval. 440 +* LoRaWAN protocol & radio related command. 391 391 392 -((( 393 -They are the same for all Dragino Devices which supports DLWS-005 LoRaWAN Stack(Note~*~*). These commands can be found on the wiki: [[End Device Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] 394 -))) 442 +They are same for all Dragino Devices which support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki: 395 395 396 -* ((( 397 -(% style="color:#4f81bd" %)**Commands special design for LHT65N-E5** 398 -))) 444 +[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]] 399 399 400 -((( 401 -These commands are only valid for LHT65N-E5, as below: 402 -))) 403 403 447 +== 4.3 Commands special design for LHT65N-PIR == 404 404 405 -== 4.1 Set Transmit Interval Time == 406 406 450 +These commands only valid for LHT65N-PIR, as below: 407 407 452 + 453 +=== 4.3.1 Set Transmit Interval Time === 454 + 455 + 408 408 Feature: Change LoRaWAN End Node Transmit Interval. 409 409 410 410 ... ... @@ -413,7 +413,7 @@ 413 413 [[image:image-20220523150701-2.png||_mstalt="427453"]] 414 414 415 415 416 -(% style="color:#4f81bd" %)**Downlink Command: 0x01**464 +(% style="color:#4f81bd" %)**Downlink Payload: 0x01** 417 417 418 418 Format: Command Code (0x01) followed by 3 bytes time value. 419 419 ... ... @@ -423,9 +423,18 @@ 423 423 424 424 * **Example 2**: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 425 425 426 -== 4.2 CurrentlyonlysupportsE5==474 +=== 4.3.2 Get Device Status === 427 427 476 +Send a LoRaWAN downlink to ask device send Alarm settings. 428 428 478 +* (% style="color:#4f81bd" %)**Downlink Payload**(%%)**: **0x26 01 479 + 480 +Sensor will upload Device Status via FPORT=5. See payload section for detail. 481 + 482 + 483 +=== 4.3.3 Set Password === 484 + 485 + 429 429 Feature: Set device password, max 9 digits 430 430 431 431 ... ... @@ -449,7 +449,7 @@ 449 449 450 450 * 0xA205: Set external sensor type to E5 451 451 452 -== 4.3 Set to sleep mode == 509 +=== 4.3.4 Set to sleep mode === 453 453 454 454 455 455 Feature: Set device to sleep mode ... ... @@ -466,174 +466,58 @@ 466 466 467 467 * There is no downlink command to set to Sleep mode. 468 468 469 - 526 +=== 4.3.5 Set UOA (Uplink on Activity) === 470 470 471 - = 5. Battery & PowerConsumption=528 +Feature: Enable / Disable Uplink on Activity 472 472 473 -LHT65N-PIR use **CR17450** battery pack. See below link for detail information about the battery info and how to replace. 530 +* **AT+UOA=0** : Disable UoA 531 +* **AT+UOA=1,2** : Enable UoA , Calm Down Time: 2 minutes. If device already send a uplink on activity, it will not send another uplink on activiy in 2 minutes, even detect activity. 474 474 475 - [[**BatteryInfo & Power Consumption Analyze**>>url:http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20calculate%20the%20battery%20life%20of%20Dragino%20sensors%3F/]].533 +(% style="color:#4f81bd" %)**AT Command: AT+UOA** 476 476 477 477 478 -= 6.FAQ=536 +(% style="color:#4f81bd" %)**Downlink Command: **(% class="mark" %)**xxxxxxx** 479 479 480 -== 6.1 How to use AT Command? == 481 481 539 += 5. Battery & Power Consumption = 482 482 483 -LHT65N- E5supportsATCommandset.UsercanuseaUSBtoTTL adapter plusthe ProgramCabletoconnect toLHT65 forusing AT command,asbelow.541 +LHT65N-PIR use **CR17450** battery pack. See below link for detail information about the battery info and how to replace. 484 484 543 +[[**Battery Info & Power Consumption Analyze**>>url:http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20calculate%20the%20battery%20life%20of%20Dragino%20sensors%3F/]] . 485 485 486 -[[image:image-20220615153355-1.png||_mstalt="430222"]] 487 487 546 += 6. OTA firmware update = 488 488 548 +Please see this link for how to do OTA firmware update: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/]] 489 489 490 -[[image:1655802313617-381.png||_mstalt="293917"]] 491 491 551 += 7. FAQ = 492 492 553 +== 7.1 How to use AT Command? == 493 493 494 -((( 495 -In PC, User needs to set serial tool(such as [[**putty**>>https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to (% style="color:green" %)**9600** (%%)to access to access serial console for LHT65N-E5. The AT commands are disable by default and need to enter password (default:(% style="color:green" %)**123456**(% style="color:red" %))(%%) to active it. Timeout to input AT Command is 5 min, after 5-minute, user need to input password again. User can use AT+DISAT command to disable AT command before timeout. 496 -))) 497 497 498 - [[image:image-20220615154519-3.png||_mstalt="431925"height="672"width="807"]]556 +LHT65N-E5 supports AT Command set.User can use a USB to TTL adapter plus the Program Cable to connect to LHT65 for using AT command, as below. 499 499 500 -AT Command List is as below: 501 501 502 - AT+<CMD>?:lpon<CMD>559 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615153355-1.png||_mstalt="430222"]] 503 503 504 -AT+<CMD> : Run <CMD> 505 505 506 -AT+<CMD>=<value> : Set the value 507 507 508 - AT+<CMD>=?:Getthevalue563 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@1655802313617-381.png||_mstalt="293917"]] 509 509 510 -AT+DEBUG: Set more info output 511 511 512 - ATZ:ga reset oftheMCU566 +In PC, User needs to set serial tool(such as [[**putty**>>https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to (% style="color:green" %)**9600** (%%)to access to access serial console for LHT65N-E5. The AT commands are disable by default and need to enter password (default:(% style="color:green" %)**123456**(% style="color:red" %))(%%) to active it. Timeout to input AT Command is 5 min, after 5-minute, user need to input password again. User can use AT+DISAT command to disable AT command before timeout. 513 513 514 - AT+FDR:ResetParameterstoFactoryDefault, KeysReserve568 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615154519-3.png||_mstalt="431925" height="672" width="807"]] 515 515 516 -AT+DEUI: Get or Set the Device EUI 517 517 518 -AT+DADDR: Get or Set the Device Address 519 519 520 - AT+APPKEY:Get orSetthe ApplicationKey572 +== 7.2 Where to use AT commands and Downlink commands == 521 521 522 -AT+NWKSKEY: Get or Set the Network Session Key 523 523 524 -AT+APPSKEY: Get or Set the Application Session Key 525 - 526 -AT+APPEUI: Get or Set the Application EUI 527 - 528 -AT+ADR: Get or Set the Adaptive Data Rate setting. (0: off, 1: on) 529 - 530 -AT+TXP: Get or Set the Transmit Power (0-5, MAX:0, MIN:5, according to LoRaWAN Spec) 531 - 532 -AT+DR: Get or Set the Data Rate. (0-7 corresponding to DR_X) 533 - 534 -AT+DCS: Get or Set the ETSI Duty Cycle setting - 0=disable, 1=enable - Only for testing 535 - 536 -AT+PNM: Get or Set the public network mode. (0: off, 1: on) 537 - 538 -AT+RX2FQ: Get or Set the Rx2 window frequency 539 - 540 -AT+RX2DR: Get or Set the Rx2 window data rate (0-7 corresponding to DR_X) 541 - 542 -AT+RX1DL: Get or Set the delay between the end of the Tx and the Rx Window 1 in ms 543 - 544 -AT+RX2DL: Get or Set the delay between the end of the Tx and the Rx Window 2 in ms 545 - 546 -AT+JN1DL: Get or Set the Join Accept Delay between the end of the Tx and the Join Rx Window 1 in ms 547 - 548 -AT+JN2DL: Get or Set the Join Accept Delay between the end of the Tx and the Join Rx Window 2 in ms 549 - 550 -AT+NJM: Get or Set the Network Join Mode. (0: ABP, 1: OTAA) 551 - 552 -AT+NWKID: Get or Set the Network ID 553 - 554 -AT+FCU: Get or Set the Frame Counter Uplink 555 - 556 -AT+FCD: Get or Set the Frame Counter Downlink 557 - 558 -AT+CLASS: Get or Set the Device Class 559 - 560 -AT+JOIN: Join network 561 - 562 -AT+NJS: Get the join status 563 - 564 -AT+SENDB: Send hexadecimal data along with the application port 565 - 566 -AT+SEND: Send text data along with the application port 567 - 568 -AT+RECVB: Print last received data in binary format (with hexadecimal values) 569 - 570 -AT+RECV: Print last received data in raw format 571 - 572 -AT+VER: Get current image version and Frequency Band 573 - 574 -AT+CFM: Get or Set the confirmation mode (0-1) 575 - 576 -AT+CFS: Get confirmation status of the last AT+SEND (0-1) 577 - 578 -AT+SNR: Get the SNR of the last received packet 579 - 580 -AT+RSSI: Get the RSSI of the last received packet 581 - 582 -AT+TDC: Get or set the application data transmission interval in ms 583 - 584 -AT+PORT: Get or set the application port 585 - 586 -AT+DISAT: Disable AT commands 587 - 588 -AT+PWORD: Set password, max 9 digits 589 - 590 -AT+CHS: Get or Set Frequency (Unit: Hz) for Single Channel Mode 591 - 592 -AT+CHE: Get or Set eight channels mode,Only for US915,AU915,CN470 593 - 594 -AT+PDTA: Print the sector data from start page to stop page 595 - 596 -AT+PLDTA: Print the last few sets of data 597 - 598 -AT+CLRDTA: Clear the storage, record position back to 1st 599 - 600 -AT+SLEEP: Set sleep mode 601 - 602 -AT+EXT: Get or Set external sensor model 603 - 604 -AT+BAT: Get the current battery voltage in mV 605 - 606 -AT+CFG: Print all configurations 607 - 608 -AT+WMOD: Get or Set Work Mode 609 - 610 -AT+ARTEMP: Get or set the internal Temperature sensor alarm range 611 - 612 -AT+CITEMP: Get or set the internal Temperature sensor collection interval in min 613 - 614 -AT+SETCNT: Set the count at present 615 - 616 -AT+RJTDC: Get or set the ReJoin data transmission interval in min 617 - 618 -AT+RPL: Get or set response level 619 - 620 -AT+TIMESTAMP: Get or Set UNIX timestamp in second 621 - 622 -AT+LEAPSEC: Get or Set Leap Second 623 - 624 -AT+SYNCMOD: Get or Set time synchronization method 625 - 626 -AT+SYNCTDC: Get or set time synchronization interval in day 627 - 628 -AT+PID: Get or set the PID 629 - 630 - 631 -== 6.2 Where to use AT commands and Downlink commands == 632 - 633 - 634 634 **AT commands:** 635 635 636 -[[image:image-20220620153708-1.png||_mstalt="429806" height="603" width="723"]] 577 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220620153708-1.png||_mstalt="429806" height="603" width="723"]] 637 637 638 638 639 639 **Downlink commands:** ... ... @@ -642,13 +642,13 @@ 642 642 643 643 (% style="color:blue" %)**TTN:** 644 644 645 -[[image:image-20220615092124-2.png||_mstalt="429221" height="649" width="688"]] 586 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615092124-2.png||_mstalt="429221" height="649" width="688"]] 646 646 647 647 648 648 649 649 (% style="color:blue" %)**Helium:** 650 650 651 -[[image:image-20220615092551-3.png||_mstalt="430794" height="423" width="835"]] 592 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615092551-3.png||_mstalt="430794" height="423" width="835"]] 652 652 653 653 654 654 ... ... @@ -655,56 +655,49 @@ 655 655 (% style="color:blue" %)**Chirpstack: The downlink window will not be displayed until the network is accessed** 656 656 657 657 658 -[[image:image-20220615094850-6.png||_mstalt="433082"]] 599 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615094850-6.png||_mstalt="433082"]] 659 659 660 660 661 -[[image:image-20220615094904-7.png||_mstalt="433485" height="281" width="911"]] 602 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615094904-7.png||_mstalt="433485" height="281" width="911"]] 662 662 663 663 664 664 665 665 (% style="color:blue" %)**Aws:** 666 666 667 -[[image:image-20220615092939-4.png||_mstalt="434460" height="448" width="894"]] 608 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615092939-4.png||_mstalt="434460" height="448" width="894"]] 668 668 669 669 670 670 == 6.3 How to change the uplink interval? == 671 671 672 - 673 673 Please see this link: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/How%20to%20set%20the%20transmit%20time%20interval/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20set%20the%20transmit%20time%20interval/||_mstmutation="1" style="background-color: rgb(255, 255, 255);"]] 674 674 615 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615154519-3.png||_mstalt="431925" height="672" width="807"]] 675 675 676 676 677 - [[image:image-20220615154519-3.png||_mstalt="431925"height="672"width="807"]]618 +== 7.4 How to use TTL-USB to connect PC to upgrade firmware? == 678 678 620 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615153355-1.png||_mstalt="430222"]] 679 679 680 -== 6.4 How to use TTL-USB to connect PC to upgrade firmware? == 681 - 682 - 683 -[[image:image-20220615153355-1.png||_mstalt="430222"]] 684 - 685 - 686 686 (% style="color:blue" %)**Step1**(%%): Install TremoProgrammer first. 687 687 688 -[[image:image-20220615170542-5.png||_mstalt="430638"]] 624 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615170542-5.png||_mstalt="430638"]] 689 689 690 - 691 - 692 692 (% _mstmutation="1" style="color:blue" %)**Step2**(%%):wiring method.(% style="display:none" %) 693 693 694 694 First connect the four lines;(% style="display:none" %) 695 695 696 -[[image:image-20220621170938-1.png||_mstalt="431340" height="413" width="419"]],(% style="display:none" %) 630 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220621170938-1.png||_mstalt="431340" height="413" width="419"]],(% style="display:none" %) 697 697 698 698 699 699 Then use DuPont cable to short circuit port3 and port1, and then release them, so that the device enters bootlaod mode. 700 700 701 -[[image:image-20220621170938-2.png||_mstalt="431704"]] 635 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220621170938-2.png||_mstalt="431704"]] 702 702 703 703 704 704 705 705 (% style="color:blue" %)**Step3:**(%%)Select the device port to be connected, baud rate and bin file to be downloaded. 706 706 707 -[[image:image-20220615171334-6.png||_mstalt="431028"]] 641 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615171334-6.png||_mstalt="431028"]] 708 708 709 709 710 710 Click the (% style="color:blue" %)**start**(%%) button to start the firmware upgrade. ... ... @@ -712,7 +712,7 @@ 712 712 713 713 When this interface appears, it indicates that the download has been completed. 714 714 715 -[[image:image-20220620160723-8.png||_mstalt="430703"]] 649 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220620160723-8.png||_mstalt="430703"]] 716 716 717 717 718 718 Finally, unplug the DuPont cable on port4, and then use the DuPont cable to short circuit port3 and port1 to reset the device. ... ... @@ -719,10 +719,10 @@ 719 719 720 720 721 721 722 -[[image:image-20220615154519-3.png||_mstalt="431925" height="672" width="807"]] 656 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615154519-3.png||_mstalt="431925" height="672" width="807"]] 723 723 724 724 725 -= 7. Order Info =659 += 8. Order Info = 726 726 727 727 728 728 Part Number: (% style="color:#4f81bd" %)** LHT65N-PIR-XX** ... ... @@ -738,7 +738,7 @@ 738 738 * (% style="color:#4f81bd" %)** **(% _mstmutation="1" style="color:red" %)**IN865**(%%): LoRaWAN IN865 band 739 739 * (% style="color:#4f81bd" %)** **(% _mstmutation="1" style="color:red" %)**CN470**(%%): LoRaWAN CN470 band 740 740 741 -= 8. Packing Info =675 += 9. Packing Info = 742 742 743 743 744 744 **Package Includes**: ... ... @@ -750,12 +750,12 @@ 750 750 * Device Size: 10 x 10 x 3.5 mm 751 751 * Device Weight: 120.5g 752 752 753 -= 9. Reference material =687 += 10. Reference material = 754 754 755 755 756 756 * [[Datasheet, photos, decoder, firmware>>https://www.dropbox.com/sh/una19zsni308dme/AACOKp6J2RF5TMlKWT5zU3RTa?dl=0]] 757 757 758 -= 1 0. FCC Warning =692 += 11. FCC Warning = 759 759 760 760 761 761 This device complies with part 15 of the FCC Rules.Operation is subject to the following two conditions: