Changes for page LHT65N-PIR Temperature/Humidity/PIR Motion Sensor User Manual
Last modified by Xiaoling on 2025/04/24 10:00
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -355,56 +355,39 @@ 355 355 [[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220619092421-3.png||_mstalt="430547" height="371" width="529"]] 356 356 357 357 358 -= 4. Configure LHT65N-PIR via AT command or LoRaWAN downlink=358 += 4. Configure LHT65N-PIR = 359 359 360 +== 4.1 Configure Methods: == 360 360 361 -((( 362 -Use can configure LHT65N-E5 via AT Command or LoRaWAN Downlink. 363 -))) 364 364 365 -* ((( 366 -AT Command Connection: See [[FAQ>>||anchor="H6.FAQ"]]. 367 -))) 363 +LHT65N-PIR supports below configure method: 368 368 369 -* ((( 370 -LoRaWAN Downlink instruction for different platforms: [[IoT LoRaWAN Server>>doc:Main.WebHome]] 371 -))) 365 +* AT Command via UART Connection : See [[FAQ>>path:#H7.FAQ]]. 366 +* LoRaWAN Downlink. Instruction for different platforms: See [[IoT LoRaWAN Server>>url:http://wiki.dragino.com/xwiki/bin/view/Main/]] section. 372 372 373 -((( 374 -There are two kinds of commands to configure LHT65N-E5, they are: 375 -))) 376 376 377 -* ((( 378 -(% style="color:#4f81bd" %)**General Commands**. 379 -))) 369 +== 4.2 General Commands == 380 380 381 - (((371 + 382 382 These commands are to configure: 383 -))) 384 384 385 -1. ((( 386 -General system settings like: uplink interval. 387 -))) 388 -1. ((( 389 -LoRaWAN protocol & radio-related commands. 390 -))) 374 +* General system settings like: uplink interval. 375 +* LoRaWAN protocol & radio related command. 391 391 392 -((( 393 -They are the same for all Dragino Devices which supports DLWS-005 LoRaWAN Stack(Note~*~*). These commands can be found on the wiki: [[End Device Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] 394 -))) 377 +They are same for all Dragino Devices which support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki: 395 395 396 -* ((( 397 -(% style="color:#4f81bd" %)**Commands special design for LHT65N-E5** 398 -))) 379 +[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]] 399 399 400 -((( 401 -These commands are only valid for LHT65N-E5, as below: 402 -))) 403 403 382 +== 4.3 Commands special design for LHT65N-PIR == 404 404 405 -== 4.1 Set Transmit Interval Time == 406 406 385 +These commands only valid for LHT65N-PIR, as below: 407 407 387 + 388 +=== 4.3.1 Set Transmit Interval Time === 389 + 390 + 408 408 Feature: Change LoRaWAN End Node Transmit Interval. 409 409 410 410 ... ... @@ -413,7 +413,7 @@ 413 413 [[image:image-20220523150701-2.png||_mstalt="427453"]] 414 414 415 415 416 -(% style="color:#4f81bd" %)**Downlink Command: 0x01**399 +(% style="color:#4f81bd" %)**Downlink Payload: 0x01** 417 417 418 418 Format: Command Code (0x01) followed by 3 bytes time value. 419 419 ... ... @@ -423,9 +423,19 @@ 423 423 424 424 * **Example 2**: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 425 425 426 -== 4.2 Currently only supports E5 == 427 427 410 +=== 4.3.2 Get Device Status === 428 428 412 +Send a LoRaWAN downlink to ask device send Alarm settings. 413 + 414 +* (% style="color:#4f81bd" %)**Downlink Payload**(%%)**: **0x26 01 415 + 416 +Sensor will upload Device Status via FPORT=5. See payload section for detail. 417 + 418 + 419 +=== 4.3.3 Set Password === 420 + 421 + 429 429 Feature: Set device password, max 9 digits 430 430 431 431 ... ... @@ -449,9 +449,10 @@ 449 449 450 450 * 0xA205: Set external sensor type to E5 451 451 452 -== 4.3 Set to sleep mode == 453 453 446 +=== 4.3.4 Set to sleep mode === 454 454 448 + 455 455 Feature: Set device to sleep mode 456 456 457 457 * **AT+Sleep=0** : Normal working mode, device will sleep and use lower power when there is no LoRa message ... ... @@ -466,174 +466,60 @@ 466 466 467 467 * There is no downlink command to set to Sleep mode. 468 468 469 - 470 470 471 -= 5.Battery&PowerConsumption=464 +=== 4.3.5 Set UOA (Uplink on Activity) === 472 472 473 - LHT65N-PIR use**CR17450** batterypack. Seebelowlinkfordetailinformation about the batteryinfo and how to replace.466 +Feature: Enable / Disable Uplink on Activity 474 474 475 -[[**Battery Info & Power Consumption Analyze**>>url:http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20calculate%20the%20battery%20life%20of%20Dragino%20sensors%3F/]] . 468 +* **AT+UOA=0** : Disable UoA 469 +* **AT+UOA=1,2** : Enable UoA , Calm Down Time: 2 minutes. If device already send a uplink on activity, it will not send another uplink on activiy in 2 minutes, even detect activity. 476 476 477 477 478 -= 6. FAQ=472 +(% style="color:#4f81bd" %)**AT Command: AT+UOA** 479 479 480 -== 6.1 How to use AT Command? == 481 481 475 +(% style="color:#4f81bd" %)**Downlink Command: (% class="mark" %)xxxxxxx(%%)** 482 482 483 -LHT65N-E5 supports AT Command set.User can use a USB to TTL adapter plus the Program Cable to connect to LHT65 for using AT command, as below. 484 484 478 += 5. Battery & Power Consumption = 485 485 486 - [[image:image-20220615153355-1.png||_mstalt="430222"]]480 +LHT65N-PIR use **CR17450** battery pack. See below link for detail information about the battery info and how to replace. 487 487 482 +[[**Battery Info & Power Consumption Analyze**>>url:http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20calculate%20the%20battery%20life%20of%20Dragino%20sensors%3F/]] . 488 488 489 489 490 - [[image:1655802313617-381.png||_mstalt="293917"]]485 += 6. OTA firmware update = 491 491 487 +Please see this link for how to do OTA firmware update: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/]] 492 492 493 493 494 -((( 495 -In PC, User needs to set serial tool(such as [[**putty**>>https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to (% style="color:green" %)**9600** (%%)to access to access serial console for LHT65N-E5. The AT commands are disable by default and need to enter password (default:(% style="color:green" %)**123456**(% style="color:red" %))(%%) to active it. Timeout to input AT Command is 5 min, after 5-minute, user need to input password again. User can use AT+DISAT command to disable AT command before timeout. 496 -))) 490 += 6. FAQ = 497 497 498 - [[image:image-20220615154519-3.png||_mstalt="431925"height="672"width="807"]]492 +== 6.1 How to use AT Command? == 499 499 500 -AT Command List is as below: 501 501 502 -AT +<CMD>?:Helpon<CMD>495 +LHT65N-E5 supports AT Command set.User can use a USB to TTL adapter plus the Program Cable to connect to LHT65 for using AT command, as below. 503 503 504 -AT+<CMD> : Run <CMD> 505 505 506 - AT+<CMD>=<value>:Setthevalue498 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615153355-1.png||_mstalt="430222"]] 507 507 508 -AT+<CMD>=? : Get the value 509 509 510 -AT+DEBUG: Set more info output 511 511 512 - ATZ:garesetofthe MCU502 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@1655802313617-381.png||_mstalt="293917"]] 513 513 514 -AT+FDR: Reset Parameters to Factory Default, Keys Reserve 515 515 516 - AT+DEUI:Get or Set theDevice EUI505 +In PC, User needs to set serial tool(such as [[**putty**>>https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to (% style="color:green" %)**9600** (%%)to access to access serial console for LHT65N-E5. The AT commands are disable by default and need to enter password (default:(% style="color:green" %)**123456**(% style="color:red" %))(%%) to active it. Timeout to input AT Command is 5 min, after 5-minute, user need to input password again. User can use AT+DISAT command to disable AT command before timeout. 517 517 518 - AT+DADDR:GetorSettheDeviceAddress507 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615154519-3.png||_mstalt="431925" height="672" width="807"]] 519 519 520 -AT+APPKEY: Get or Set the Application Key 521 521 522 -AT+NWKSKEY: Get or Set the Network Session Key 523 523 524 -AT+APPSKEY: Get or Set the Application Session Key 525 - 526 -AT+APPEUI: Get or Set the Application EUI 527 - 528 -AT+ADR: Get or Set the Adaptive Data Rate setting. (0: off, 1: on) 529 - 530 -AT+TXP: Get or Set the Transmit Power (0-5, MAX:0, MIN:5, according to LoRaWAN Spec) 531 - 532 -AT+DR: Get or Set the Data Rate. (0-7 corresponding to DR_X) 533 - 534 -AT+DCS: Get or Set the ETSI Duty Cycle setting - 0=disable, 1=enable - Only for testing 535 - 536 -AT+PNM: Get or Set the public network mode. (0: off, 1: on) 537 - 538 -AT+RX2FQ: Get or Set the Rx2 window frequency 539 - 540 -AT+RX2DR: Get or Set the Rx2 window data rate (0-7 corresponding to DR_X) 541 - 542 -AT+RX1DL: Get or Set the delay between the end of the Tx and the Rx Window 1 in ms 543 - 544 -AT+RX2DL: Get or Set the delay between the end of the Tx and the Rx Window 2 in ms 545 - 546 -AT+JN1DL: Get or Set the Join Accept Delay between the end of the Tx and the Join Rx Window 1 in ms 547 - 548 -AT+JN2DL: Get or Set the Join Accept Delay between the end of the Tx and the Join Rx Window 2 in ms 549 - 550 -AT+NJM: Get or Set the Network Join Mode. (0: ABP, 1: OTAA) 551 - 552 -AT+NWKID: Get or Set the Network ID 553 - 554 -AT+FCU: Get or Set the Frame Counter Uplink 555 - 556 -AT+FCD: Get or Set the Frame Counter Downlink 557 - 558 -AT+CLASS: Get or Set the Device Class 559 - 560 -AT+JOIN: Join network 561 - 562 -AT+NJS: Get the join status 563 - 564 -AT+SENDB: Send hexadecimal data along with the application port 565 - 566 -AT+SEND: Send text data along with the application port 567 - 568 -AT+RECVB: Print last received data in binary format (with hexadecimal values) 569 - 570 -AT+RECV: Print last received data in raw format 571 - 572 -AT+VER: Get current image version and Frequency Band 573 - 574 -AT+CFM: Get or Set the confirmation mode (0-1) 575 - 576 -AT+CFS: Get confirmation status of the last AT+SEND (0-1) 577 - 578 -AT+SNR: Get the SNR of the last received packet 579 - 580 -AT+RSSI: Get the RSSI of the last received packet 581 - 582 -AT+TDC: Get or set the application data transmission interval in ms 583 - 584 -AT+PORT: Get or set the application port 585 - 586 -AT+DISAT: Disable AT commands 587 - 588 -AT+PWORD: Set password, max 9 digits 589 - 590 -AT+CHS: Get or Set Frequency (Unit: Hz) for Single Channel Mode 591 - 592 -AT+CHE: Get or Set eight channels mode,Only for US915,AU915,CN470 593 - 594 -AT+PDTA: Print the sector data from start page to stop page 595 - 596 -AT+PLDTA: Print the last few sets of data 597 - 598 -AT+CLRDTA: Clear the storage, record position back to 1st 599 - 600 -AT+SLEEP: Set sleep mode 601 - 602 -AT+EXT: Get or Set external sensor model 603 - 604 -AT+BAT: Get the current battery voltage in mV 605 - 606 -AT+CFG: Print all configurations 607 - 608 -AT+WMOD: Get or Set Work Mode 609 - 610 -AT+ARTEMP: Get or set the internal Temperature sensor alarm range 611 - 612 -AT+CITEMP: Get or set the internal Temperature sensor collection interval in min 613 - 614 -AT+SETCNT: Set the count at present 615 - 616 -AT+RJTDC: Get or set the ReJoin data transmission interval in min 617 - 618 -AT+RPL: Get or set response level 619 - 620 -AT+TIMESTAMP: Get or Set UNIX timestamp in second 621 - 622 -AT+LEAPSEC: Get or Set Leap Second 623 - 624 -AT+SYNCMOD: Get or Set time synchronization method 625 - 626 -AT+SYNCTDC: Get or set time synchronization interval in day 627 - 628 -AT+PID: Get or set the PID 629 - 630 - 631 631 == 6.2 Where to use AT commands and Downlink commands == 632 632 633 633 634 634 **AT commands:** 635 635 636 -[[image:image-20220620153708-1.png||_mstalt="429806" height="603" width="723"]] 516 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220620153708-1.png||_mstalt="429806" height="603" width="723"]] 637 637 638 638 639 639 **Downlink commands:** ... ... @@ -642,13 +642,13 @@ 642 642 643 643 (% style="color:blue" %)**TTN:** 644 644 645 -[[image:image-20220615092124-2.png||_mstalt="429221" height="649" width="688"]] 525 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615092124-2.png||_mstalt="429221" height="649" width="688"]] 646 646 647 647 648 648 649 649 (% style="color:blue" %)**Helium:** 650 650 651 -[[image:image-20220615092551-3.png||_mstalt="430794" height="423" width="835"]] 531 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615092551-3.png||_mstalt="430794" height="423" width="835"]] 652 652 653 653 654 654 ... ... @@ -655,56 +655,49 @@ 655 655 (% style="color:blue" %)**Chirpstack: The downlink window will not be displayed until the network is accessed** 656 656 657 657 658 -[[image:image-20220615094850-6.png||_mstalt="433082"]] 538 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615094850-6.png||_mstalt="433082"]] 659 659 660 660 661 -[[image:image-20220615094904-7.png||_mstalt="433485" height="281" width="911"]] 541 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615094904-7.png||_mstalt="433485" height="281" width="911"]] 662 662 663 663 664 664 665 665 (% style="color:blue" %)**Aws:** 666 666 667 -[[image:image-20220615092939-4.png||_mstalt="434460" height="448" width="894"]] 547 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615092939-4.png||_mstalt="434460" height="448" width="894"]] 668 668 669 669 670 670 == 6.3 How to change the uplink interval? == 671 671 672 - 673 673 Please see this link: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/How%20to%20set%20the%20transmit%20time%20interval/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20set%20the%20transmit%20time%20interval/||_mstmutation="1" style="background-color: rgb(255, 255, 255);"]] 674 674 554 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615154519-3.png||_mstalt="431925" height="672" width="807"]] 675 675 676 676 677 -[[image:image-20220615154519-3.png||_mstalt="431925" height="672" width="807"]] 678 - 679 - 680 680 == 6.4 How to use TTL-USB to connect PC to upgrade firmware? == 681 681 559 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615153355-1.png||_mstalt="430222"]] 682 682 683 -[[image:image-20220615153355-1.png||_mstalt="430222"]] 684 - 685 - 686 686 (% style="color:blue" %)**Step1**(%%): Install TremoProgrammer first. 687 687 688 -[[image:image-20220615170542-5.png||_mstalt="430638"]] 563 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615170542-5.png||_mstalt="430638"]] 689 689 690 - 691 - 692 692 (% _mstmutation="1" style="color:blue" %)**Step2**(%%):wiring method.(% style="display:none" %) 693 693 694 694 First connect the four lines;(% style="display:none" %) 695 695 696 -[[image:image-20220621170938-1.png||_mstalt="431340" height="413" width="419"]],(% style="display:none" %) 569 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220621170938-1.png||_mstalt="431340" height="413" width="419"]],(% style="display:none" %) 697 697 698 698 699 699 Then use DuPont cable to short circuit port3 and port1, and then release them, so that the device enters bootlaod mode. 700 700 701 -[[image:image-20220621170938-2.png||_mstalt="431704"]] 574 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220621170938-2.png||_mstalt="431704"]] 702 702 703 703 704 704 705 705 (% style="color:blue" %)**Step3:**(%%)Select the device port to be connected, baud rate and bin file to be downloaded. 706 706 707 -[[image:image-20220615171334-6.png||_mstalt="431028"]] 580 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615171334-6.png||_mstalt="431028"]] 708 708 709 709 710 710 Click the (% style="color:blue" %)**start**(%%) button to start the firmware upgrade. ... ... @@ -712,7 +712,7 @@ 712 712 713 713 When this interface appears, it indicates that the download has been completed. 714 714 715 -[[image:image-20220620160723-8.png||_mstalt="430703"]] 588 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220620160723-8.png||_mstalt="430703"]] 716 716 717 717 718 718 Finally, unplug the DuPont cable on port4, and then use the DuPont cable to short circuit port3 and port1 to reset the device. ... ... @@ -719,7 +719,7 @@ 719 719 720 720 721 721 722 -[[image:image-20220615154519-3.png||_mstalt="431925" height="672" width="807"]] 595 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615154519-3.png||_mstalt="431925" height="672" width="807"]] 723 723 724 724 725 725 = 7. Order Info =