Changes for page LHT65N-PIR Temperature/Humidity/PIR Motion Sensor User Manual
Last modified by Xiaoling on 2025/04/24 10:00
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 -LHT65-PIR Temperature/Humidity/PIR Sensor User Manual 1 +LHT65-PIR Temperature/Humidity/PIR Motion Sensor User Manual - Content
-
... ... @@ -156,8 +156,73 @@ 156 156 [[image:image-20220522233300-8.png||_mstalt="428389" height="219" width="722"]] 157 157 158 158 159 -== 2.4 Uplink Payload (Fport~=2) ==159 +== 2.4 Uplink Payload~-~-Device Status, (Fport~=5) == 160 160 161 +Users can use the downlink command(**0x26 01**) to ask LHT65N-PIR to send device configure detail, include device configure status. LHT65N-PIR will uplink a payload via FPort=5 to server. 162 + 163 +The Payload format is as below. 164 + 165 +|(% colspan="6" %)**Device Status (FPORT=5)** 166 +|**Size (bytes)**|**1**|**2**|**1**|**1**|**2** 167 +|**Value**|Sensor Model|Firmware Version|Frequency Band|Sub-band|BAT 168 + 169 +Example parse in TTNv3 170 + 171 +[[image:1675144504430-490.png]] 172 + 173 +**Sensor Model**: For LHT65N-PIR, this value is 0x1A 174 + 175 +**Firmware Version**: 0x0100, Means: v1.0.0 version 176 + 177 +**Frequency Band**: 178 + 179 +*0x01: EU868 180 + 181 +*0x02: US915 182 + 183 +*0x03: IN865 184 + 185 +*0x04: AU915 186 + 187 +*0x05: KZ865 188 + 189 +*0x06: RU864 190 + 191 +*0x07: AS923 192 + 193 +*0x08: AS923-1 194 + 195 +*0x09: AS923-2 196 + 197 +*0x0a: AS923-3 198 + 199 +*0x0b: CN470 200 + 201 +*0x0c: EU433 202 + 203 +*0x0d: KR920 204 + 205 +*0x0e: MA869 206 + 207 +**Sub-Band**: 208 + 209 +AU915 and US915:value 0x00 ~~ 0x08 210 + 211 +CN470: value 0x0B ~~ 0x0C 212 + 213 +Other Bands: Always 0x00 214 + 215 +**Battery Info**: 216 + 217 +Check the battery voltage. 218 + 219 +Ex1: 0x0B45 = 2885mV 220 + 221 +Ex2: 0x0B49 = 2889mV 222 + 223 + 224 +== 2.5 Uplink Payload, Sensor Data ( Fport~=2) == 225 + 161 161 The uplink payload includes totally 11 bytes. Uplink packets use FPORT=2 and (% style="color:#4f81bd" %)**every 20 minutes**(%%) send one uplink by default. 162 162 163 163 After each uplink, the (% style="color:blue" %)**BLUE LED**(%%) will blink once. ... ... @@ -199,7 +199,7 @@ 199 199 * The 8^^th^^ byte: Alarm Bit (if this uplink is from periodically or movement) 200 200 * The 9^^th^^ ~~ 11^^st^^ byte: Movement Detect Count. 201 201 202 -=== 2. 4.1 Decoder in TTN V3 ===267 +=== 2.5.1 Decoder in TTN V3 === 203 203 204 204 205 205 When the uplink payload arrives TTNv3, it shows HEX format and not friendly to read. We can add LHT65N-PIR decoder in TTNv3 for friendly reading. ... ... @@ -210,7 +210,7 @@ 210 210 [[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220522234118-10.png||_mstalt="451464" height="353" width="729"]] 211 211 212 212 213 -=== 2. 4.2 BAT-Battery Info ===278 +=== 2.5.2 BAT-Battery Info === 214 214 215 215 216 216 These two bytes of BAT include the battery state and the actually voltage ... ... @@ -226,7 +226,7 @@ 226 226 * BAT status=(0xcba4>>14)&0xFF=11(B),very good 227 227 * Battery Voltage =0xCBF6&0x3FFF=0x0BA4=2980mV 228 228 229 -=== 2. 4.3 Built-in Temperature ===294 +=== 2.5.3 Built-in Temperature === 230 230 231 231 [[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220522235639-2.png||_mstalt="431756" height="138" width="722"]] 232 232 ... ... @@ -236,22 +236,20 @@ 236 236 237 237 * Temperature: (0xF5C6-65536)/100=-26.18℃ 238 238 304 +=== 2.5.4 Built-in Humidity === 239 239 240 -=== 2.4.4 Built-in Humidity === 241 - 242 242 [[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220522235639-4.png||_mstalt="432484" height="138" width="722"]] 243 243 244 244 * Humidity: 0x025C/10=60.4% 245 245 310 +=== 2.5.5 Ext value === 246 246 247 -=== 2. 4.5 Extvalue ===312 +==== 2.5.5.1 Ext~=0x0A, PIR Sensor ==== 248 248 249 -==== 2.4.5.1 Ext~=0x0A, PIR Sensor ==== 250 - 251 251 [[image:image-20221224161634-2.png||height="138" width="851"]] 252 252 253 253 254 -==== 2. 4.5.2 Ext Value ====317 +==== 2.5.5.2 Ext Value ==== 255 255 256 256 There are 4 bytes in Ext Value field. 257 257 ... ... @@ -259,7 +259,7 @@ 259 259 260 260 (% border="1" cellspacing="4" style="background-color:#ffffcc; color:green; width:490px" %) 261 261 |=(% style="width: 147px;" %)((( 262 -**The 8^^th^^ byte s**325 +**The 8^^th^^ byte** 263 263 )))|=(% style="width: 108px;" %)((( 264 264 **Bit 1~~7** 265 265 )))|=(% style="width: 228px;" %)((( ... ... @@ -285,7 +285,7 @@ 285 285 0x00 E5 09 : Total detect 58633 activity since end node start. 286 286 287 287 288 -== 2. 5Show data on Datacake ==351 +== 2.6 Show data on Datacake == 289 289 290 290 Datacake IoT platform provides a human-friendly interface to show the sensor data, once we have sensor data in TTN V3, we can use Datacake to connect to TTN V3 and see the data in Datacake. Below are the steps: 291 291 ... ... @@ -295,7 +295,7 @@ 295 295 296 296 Add Datacake: 297 297 298 -[[image:image-20220523000825-7.png||_mstalt="429884" height="262" width="583"]] 361 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220523000825-7.png||_mstalt="429884" height="262" width="583"]] 299 299 300 300 301 301 ... ... @@ -302,20 +302,20 @@ 302 302 Select default key as Access Key: 303 303 304 304 305 -[[image:image-20220523000825-8.png||_mstalt="430248" height="453" width="406"]] 368 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220523000825-8.png||_mstalt="430248" height="453" width="406"]] 306 306 307 307 308 308 In Datacake console ([[https:~~/~~/datacake.co/>>url:https://datacake.co/]]) , add LHT65 device. 309 309 310 310 311 -[[image:image-20221224161935-5.png||height="523" width="409"]] 374 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20221224161935-5.png||height="523" width="409"]] 312 312 313 313 314 -[[image:image-20221224161957-6.png||height="306" width="852"]] 377 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20221224161957-6.png||height="306" width="852"]] 315 315 316 316 317 317 318 -== 2. 8LED Indicator ==381 +== 2.7 LED Indicator == 319 319 320 320 321 321 The LHT65N-PIR has a triple color LED which for easy showing different stage . ... ... @@ -329,18 +329,20 @@ 329 329 * RED LED when external sensor is not connected 330 330 * For each success downlink, the PURPLE LED will blink once 331 331 332 -== 2. 9installation ==395 +== 2.8 installation == 333 333 397 +~1. Don't install LHT65N-PIR outdoor or place where will get wet 334 334 335 - [[image:image-20220516231650-1.png||_mstalt="428597"height="436"width="428"]]399 +2. Towards the PIR probe to the place where need to monitor activity. 336 336 337 337 402 + 338 338 = 3. Sensors and Accessories = 339 339 340 340 == 3.1 E2 Extension Cable == 341 341 342 342 343 -[[image:image-20220619092222-1.png||_mstalt="429533" height="182" width="188"]][[image:image-20220619092313-2.png||_mstalt="430222" height="182" width="173"]] 408 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220619092222-1.png||_mstalt="429533" height="182" width="188"]][[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220619092313-2.png||_mstalt="430222" height="182" width="173"]] 344 344 345 345 346 346 **1m long breakout cable for LHT65N-E5. Features:** ... ... @@ -352,59 +352,41 @@ 352 352 Update firmware for LHT65N-PIR 353 353 ))) 354 354 355 -[[image:image-20220619092421-3.png||_mstalt="430547" height="371" width="529"]] 420 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220619092421-3.png||_mstalt="430547" height="371" width="529"]] 356 356 357 357 358 -= 4. Configure LHT65N-PIR via AT command or LoRaWAN downlink=423 += 4. Configure LHT65N-PIR = 359 359 425 +== 4.1 Configure Methods: == 360 360 361 -((( 362 -Use can configure LHT65N-E5 via AT Command or LoRaWAN Downlink. 363 -))) 364 364 365 -* ((( 366 -AT Command Connection: See [[FAQ>>||anchor="H6.FAQ"]]. 367 -))) 428 +LHT65N-PIR supports below configure method: 368 368 369 -* ((( 370 -LoRaWAN Downlink instruction for different platforms: [[IoT LoRaWAN Server>>doc:Main.WebHome]] 371 -))) 430 +* AT Command via UART Connection : See [[FAQ>>path:#H7.FAQ]]. 431 +* LoRaWAN Downlink. Instruction for different platforms: See [[IoT LoRaWAN Server>>url:http://wiki.dragino.com/xwiki/bin/view/Main/]] section. 372 372 373 -((( 374 -There are two kinds of commands to configure LHT65N-E5, they are: 375 -))) 433 +== 4.2 General Commands == 376 376 377 -* ((( 378 -(% style="color:#4f81bd" %)**General Commands**. 379 -))) 380 380 381 -((( 382 382 These commands are to configure: 383 -))) 384 384 385 -1. ((( 386 -General system settings like: uplink interval. 387 -))) 388 -1. ((( 389 -LoRaWAN protocol & radio-related commands. 390 -))) 438 +* General system settings like: uplink interval. 439 +* LoRaWAN protocol & radio related command. 391 391 392 -((( 393 -They are the same for all Dragino Devices which supports DLWS-005 LoRaWAN Stack(Note~*~*). These commands can be found on the wiki: [[End Device Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] 394 -))) 441 +They are same for all Dragino Devices which support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki: 395 395 396 -* ((( 397 -(% style="color:#4f81bd" %)**Commands special design for LHT65N-E5** 398 -))) 443 +[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]] 399 399 400 -((( 401 -These commands are only valid for LHT65N-E5, as below: 402 -))) 403 403 446 +== 4.3 Commands special design for LHT65N-PIR == 404 404 405 -== 4.1 Set Transmit Interval Time == 406 406 449 +These commands only valid for LHT65N-PIR, as below: 407 407 451 + 452 +=== 4.3.1 Set Transmit Interval Time === 453 + 454 + 408 408 Feature: Change LoRaWAN End Node Transmit Interval. 409 409 410 410 ... ... @@ -413,7 +413,7 @@ 413 413 [[image:image-20220523150701-2.png||_mstalt="427453"]] 414 414 415 415 416 -(% style="color:#4f81bd" %)**Downlink Command: 0x01**463 +(% style="color:#4f81bd" %)**Downlink Payload: 0x01** 417 417 418 418 Format: Command Code (0x01) followed by 3 bytes time value. 419 419 ... ... @@ -423,9 +423,18 @@ 423 423 424 424 * **Example 2**: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 425 425 426 -== 4.2 CurrentlyonlysupportsE5==473 +=== 4.3.2 Get Device Status === 427 427 475 +Send a LoRaWAN downlink to ask device send Alarm settings. 428 428 477 +* (% style="color:#4f81bd" %)**Downlink Payload**(%%)**: **0x26 01 478 + 479 +Sensor will upload Device Status via FPORT=5. See payload section for detail. 480 + 481 + 482 +=== 4.3.3 Set Password === 483 + 484 + 429 429 Feature: Set device password, max 9 digits 430 430 431 431 ... ... @@ -449,7 +449,7 @@ 449 449 450 450 * 0xA205: Set external sensor type to E5 451 451 452 -== 4.3 Set to sleep mode == 508 +=== 4.3.4 Set to sleep mode === 453 453 454 454 455 455 Feature: Set device to sleep mode ... ... @@ -466,206 +466,60 @@ 466 466 467 467 * There is no downlink command to set to Sleep mode. 468 468 469 -= 5.Battery&Howtoreplace=525 +=== 4.3.5 Set UOA (Uplink on Activity) === 470 470 471 - ==5.1BatteryType==527 +Feature: Enable / Disable Uplink on Activity 472 472 529 +* **AT+UOA=0** : Disable UoA 530 +* **AT+UOA=1,2** : Enable UoA , Calm Down Time: 2 minutes. If device already send a uplink on activity, it will not send another uplink on activiy in 2 minutes, even detect activity. 473 473 474 -((( 475 -LHT65N-E5 is equipped with a 2400mAH Li-MnO2 (CR17505) battery . The battery is an un-rechargeable battery with low discharge rate targeting for up to 8~~10 years use. This type of battery is commonly used in IoT devices for long-term running, such as water meters. 476 -))) 532 +Notice: Calm Down time range is 1 ~~ 65535 minutes. If user set Calm Down time to low value, such as 1 minute, the sensor might send uplink very frequenctly and battery drain fast. 477 477 478 -((( 479 -The discharge curve is not linear so can't simply use percentage to show the battery level. Below is the battery performance. 534 +(% style="color:#4f81bd" %)**AT Command: AT+UOA** 480 480 481 481 482 -[[image:image-20220515075034-1.png||_mstalt="428961" height="208" width="644"]] 483 -))) 537 +(% style="color:#4f81bd" %)**Downlink Command: **(% class="mark" %)**xxxxxxx** 484 484 485 -The minimum Working Voltage for the LHT65N-E5 is ~~ 2.5v. When battery is lower than 2.6v, it is time to change the battery. 486 - 487 487 488 -= =5.2ReplaceBattery ==540 += 5. Battery & Power Consumption = 489 489 542 +LHT65N-PIR use **CR17450** battery pack. See below link for detail information about the battery info and how to replace. 490 490 491 - LHT65N-E5 hastwo screwsontheback, Unscrewthem,and changingthe batteryinsideisok.Thebatteryis a generalCR17450(3.0v). Any brand should bek.544 +[[**Battery Info & Power Consumption Analyze**>>url:http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20calculate%20the%20battery%20life%20of%20Dragino%20sensors%3F/]] . 492 492 493 -[[image:image-20220515075440-2.png||_mstalt="429546" height="338" width="272"]][[image:image-20220515075625-3.png||_mstalt="431574" height="193" width="257"]] 494 494 547 += 6. OTA firmware update = 495 495 496 - ==5.3BatteryLifeAnalyze==549 +Please see this link for how to do OTA firmware update: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/]] 497 497 498 498 499 -((( 500 -Dragino battery-powered products are all run in Low Power mode. User can check the guideline from this link to calculate the estimated battery life: 501 -[[https:~~/~~/www.dragino.com/downloads/downloads/LoRa_End_Node/Battery_Analyze/DRAGINO_Battery_Life_Guide.pdf>>https://www.dragino.com/downloads/downloads/LoRa_End_Node/Battery_Analyze/DRAGINO_Battery_Life_Guide.pdf]] 502 -))) 552 += 7. FAQ = 503 503 554 +== 7.1 How to use AT Command? == 504 504 505 -((( 506 -A full detail test report for LHT65N-E5 on different frequency can be found at : [[https:~~/~~/www.dropbox.com/sh/r2i3zlhsyrpavla/AAB1sZw3mdT0K7XjpHCITt13a?dl=0>>https://www.dropbox.com/sh/r2i3zlhsyrpavla/AAB1sZw3mdT0K7XjpHCITt13a?dl=0]] 507 -))) 508 508 509 - 510 -= 6. FAQ = 511 - 512 -== 6.1 How to use AT Command? == 513 - 514 - 515 515 LHT65N-E5 supports AT Command set.User can use a USB to TTL adapter plus the Program Cable to connect to LHT65 for using AT command, as below. 516 516 517 517 518 -[[image:image-20220615153355-1.png||_mstalt="430222"]] 560 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615153355-1.png||_mstalt="430222"]] 519 519 520 520 521 521 522 -[[image:1655802313617-381.png||_mstalt="293917"]] 564 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@1655802313617-381.png||_mstalt="293917"]] 523 523 524 524 525 - 526 -((( 527 527 In PC, User needs to set serial tool(such as [[**putty**>>https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to (% style="color:green" %)**9600** (%%)to access to access serial console for LHT65N-E5. The AT commands are disable by default and need to enter password (default:(% style="color:green" %)**123456**(% style="color:red" %))(%%) to active it. Timeout to input AT Command is 5 min, after 5-minute, user need to input password again. User can use AT+DISAT command to disable AT command before timeout. 528 -))) 529 529 530 -[[image:image-20220615154519-3.png||_mstalt="431925" height="672" width="807"]] 569 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615154519-3.png||_mstalt="431925" height="672" width="807"]] 531 531 532 -AT Command List is as below: 533 533 534 -AT+<CMD>? : Help on <CMD> 535 535 536 - AT+<CMD>:Run<CMD>573 +== 7.2 Where to use AT commands and Downlink commands == 537 537 538 -AT+<CMD>=<value> : Set the value 539 539 540 -AT+<CMD>=? : Get the value 541 - 542 -AT+DEBUG: Set more info output 543 - 544 -ATZ: Trig a reset of the MCU 545 - 546 -AT+FDR: Reset Parameters to Factory Default, Keys Reserve 547 - 548 -AT+DEUI: Get or Set the Device EUI 549 - 550 -AT+DADDR: Get or Set the Device Address 551 - 552 -AT+APPKEY: Get or Set the Application Key 553 - 554 -AT+NWKSKEY: Get or Set the Network Session Key 555 - 556 -AT+APPSKEY: Get or Set the Application Session Key 557 - 558 -AT+APPEUI: Get or Set the Application EUI 559 - 560 -AT+ADR: Get or Set the Adaptive Data Rate setting. (0: off, 1: on) 561 - 562 -AT+TXP: Get or Set the Transmit Power (0-5, MAX:0, MIN:5, according to LoRaWAN Spec) 563 - 564 -AT+DR: Get or Set the Data Rate. (0-7 corresponding to DR_X) 565 - 566 -AT+DCS: Get or Set the ETSI Duty Cycle setting - 0=disable, 1=enable - Only for testing 567 - 568 -AT+PNM: Get or Set the public network mode. (0: off, 1: on) 569 - 570 -AT+RX2FQ: Get or Set the Rx2 window frequency 571 - 572 -AT+RX2DR: Get or Set the Rx2 window data rate (0-7 corresponding to DR_X) 573 - 574 -AT+RX1DL: Get or Set the delay between the end of the Tx and the Rx Window 1 in ms 575 - 576 -AT+RX2DL: Get or Set the delay between the end of the Tx and the Rx Window 2 in ms 577 - 578 -AT+JN1DL: Get or Set the Join Accept Delay between the end of the Tx and the Join Rx Window 1 in ms 579 - 580 -AT+JN2DL: Get or Set the Join Accept Delay between the end of the Tx and the Join Rx Window 2 in ms 581 - 582 -AT+NJM: Get or Set the Network Join Mode. (0: ABP, 1: OTAA) 583 - 584 -AT+NWKID: Get or Set the Network ID 585 - 586 -AT+FCU: Get or Set the Frame Counter Uplink 587 - 588 -AT+FCD: Get or Set the Frame Counter Downlink 589 - 590 -AT+CLASS: Get or Set the Device Class 591 - 592 -AT+JOIN: Join network 593 - 594 -AT+NJS: Get the join status 595 - 596 -AT+SENDB: Send hexadecimal data along with the application port 597 - 598 -AT+SEND: Send text data along with the application port 599 - 600 -AT+RECVB: Print last received data in binary format (with hexadecimal values) 601 - 602 -AT+RECV: Print last received data in raw format 603 - 604 -AT+VER: Get current image version and Frequency Band 605 - 606 -AT+CFM: Get or Set the confirmation mode (0-1) 607 - 608 -AT+CFS: Get confirmation status of the last AT+SEND (0-1) 609 - 610 -AT+SNR: Get the SNR of the last received packet 611 - 612 -AT+RSSI: Get the RSSI of the last received packet 613 - 614 -AT+TDC: Get or set the application data transmission interval in ms 615 - 616 -AT+PORT: Get or set the application port 617 - 618 -AT+DISAT: Disable AT commands 619 - 620 -AT+PWORD: Set password, max 9 digits 621 - 622 -AT+CHS: Get or Set Frequency (Unit: Hz) for Single Channel Mode 623 - 624 -AT+CHE: Get or Set eight channels mode,Only for US915,AU915,CN470 625 - 626 -AT+PDTA: Print the sector data from start page to stop page 627 - 628 -AT+PLDTA: Print the last few sets of data 629 - 630 -AT+CLRDTA: Clear the storage, record position back to 1st 631 - 632 -AT+SLEEP: Set sleep mode 633 - 634 -AT+EXT: Get or Set external sensor model 635 - 636 -AT+BAT: Get the current battery voltage in mV 637 - 638 -AT+CFG: Print all configurations 639 - 640 -AT+WMOD: Get or Set Work Mode 641 - 642 -AT+ARTEMP: Get or set the internal Temperature sensor alarm range 643 - 644 -AT+CITEMP: Get or set the internal Temperature sensor collection interval in min 645 - 646 -AT+SETCNT: Set the count at present 647 - 648 -AT+RJTDC: Get or set the ReJoin data transmission interval in min 649 - 650 -AT+RPL: Get or set response level 651 - 652 -AT+TIMESTAMP: Get or Set UNIX timestamp in second 653 - 654 -AT+LEAPSEC: Get or Set Leap Second 655 - 656 -AT+SYNCMOD: Get or Set time synchronization method 657 - 658 -AT+SYNCTDC: Get or set time synchronization interval in day 659 - 660 -AT+PID: Get or set the PID 661 - 662 - 663 -== 6.2 Where to use AT commands and Downlink commands == 664 - 665 - 666 666 **AT commands:** 667 667 668 -[[image:image-20220620153708-1.png||_mstalt="429806" height="603" width="723"]] 578 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220620153708-1.png||_mstalt="429806" height="603" width="723"]] 669 669 670 670 671 671 **Downlink commands:** ... ... @@ -674,13 +674,13 @@ 674 674 675 675 (% style="color:blue" %)**TTN:** 676 676 677 -[[image:image-20220615092124-2.png||_mstalt="429221" height="649" width="688"]] 587 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615092124-2.png||_mstalt="429221" height="649" width="688"]] 678 678 679 679 680 680 681 681 (% style="color:blue" %)**Helium:** 682 682 683 -[[image:image-20220615092551-3.png||_mstalt="430794" height="423" width="835"]] 593 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615092551-3.png||_mstalt="430794" height="423" width="835"]] 684 684 685 685 686 686 ... ... @@ -687,56 +687,49 @@ 687 687 (% style="color:blue" %)**Chirpstack: The downlink window will not be displayed until the network is accessed** 688 688 689 689 690 -[[image:image-20220615094850-6.png||_mstalt="433082"]] 600 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615094850-6.png||_mstalt="433082"]] 691 691 692 692 693 -[[image:image-20220615094904-7.png||_mstalt="433485" height="281" width="911"]] 603 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615094904-7.png||_mstalt="433485" height="281" width="911"]] 694 694 695 695 696 696 697 697 (% style="color:blue" %)**Aws:** 698 698 699 -[[image:image-20220615092939-4.png||_mstalt="434460" height="448" width="894"]] 609 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615092939-4.png||_mstalt="434460" height="448" width="894"]] 700 700 701 701 702 702 == 6.3 How to change the uplink interval? == 703 703 704 - 705 705 Please see this link: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/How%20to%20set%20the%20transmit%20time%20interval/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20set%20the%20transmit%20time%20interval/||_mstmutation="1" style="background-color: rgb(255, 255, 255);"]] 706 706 616 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615154519-3.png||_mstalt="431925" height="672" width="807"]] 707 707 708 708 709 - [[image:image-20220615154519-3.png||_mstalt="431925"height="672"width="807"]]619 +== 7.4 How to use TTL-USB to connect PC to upgrade firmware? == 710 710 621 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615153355-1.png||_mstalt="430222"]] 711 711 712 -== 6.4 How to use TTL-USB to connect PC to upgrade firmware? == 713 - 714 - 715 -[[image:image-20220615153355-1.png||_mstalt="430222"]] 716 - 717 - 718 718 (% style="color:blue" %)**Step1**(%%): Install TremoProgrammer first. 719 719 720 -[[image:image-20220615170542-5.png||_mstalt="430638"]] 625 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615170542-5.png||_mstalt="430638"]] 721 721 722 - 723 - 724 724 (% _mstmutation="1" style="color:blue" %)**Step2**(%%):wiring method.(% style="display:none" %) 725 725 726 726 First connect the four lines;(% style="display:none" %) 727 727 728 -[[image:image-20220621170938-1.png||_mstalt="431340" height="413" width="419"]],(% style="display:none" %) 631 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220621170938-1.png||_mstalt="431340" height="413" width="419"]],(% style="display:none" %) 729 729 730 730 731 731 Then use DuPont cable to short circuit port3 and port1, and then release them, so that the device enters bootlaod mode. 732 732 733 -[[image:image-20220621170938-2.png||_mstalt="431704"]] 636 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220621170938-2.png||_mstalt="431704"]] 734 734 735 735 736 736 737 737 (% style="color:blue" %)**Step3:**(%%)Select the device port to be connected, baud rate and bin file to be downloaded. 738 738 739 -[[image:image-20220615171334-6.png||_mstalt="431028"]] 642 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615171334-6.png||_mstalt="431028"]] 740 740 741 741 742 742 Click the (% style="color:blue" %)**start**(%%) button to start the firmware upgrade. ... ... @@ -744,7 +744,7 @@ 744 744 745 745 When this interface appears, it indicates that the download has been completed. 746 746 747 -[[image:image-20220620160723-8.png||_mstalt="430703"]] 650 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220620160723-8.png||_mstalt="430703"]] 748 748 749 749 750 750 Finally, unplug the DuPont cable on port4, and then use the DuPont cable to short circuit port3 and port1 to reset the device. ... ... @@ -751,10 +751,10 @@ 751 751 752 752 753 753 754 -[[image:image-20220615154519-3.png||_mstalt="431925" height="672" width="807"]] 657 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615154519-3.png||_mstalt="431925" height="672" width="807"]] 755 755 756 756 757 -= 7. Order Info =660 += 8. Order Info = 758 758 759 759 760 760 Part Number: (% style="color:#4f81bd" %)** LHT65N-PIR-XX** ... ... @@ -770,7 +770,7 @@ 770 770 * (% style="color:#4f81bd" %)** **(% _mstmutation="1" style="color:red" %)**IN865**(%%): LoRaWAN IN865 band 771 771 * (% style="color:#4f81bd" %)** **(% _mstmutation="1" style="color:red" %)**CN470**(%%): LoRaWAN CN470 band 772 772 773 -= 8. Packing Info =676 += 9. Packing Info = 774 774 775 775 776 776 **Package Includes**: ... ... @@ -782,12 +782,12 @@ 782 782 * Device Size: 10 x 10 x 3.5 mm 783 783 * Device Weight: 120.5g 784 784 785 -= 9. Reference material =688 += 10. Reference material = 786 786 787 787 788 788 * [[Datasheet, photos, decoder, firmware>>https://www.dropbox.com/sh/una19zsni308dme/AACOKp6J2RF5TMlKWT5zU3RTa?dl=0]] 789 789 790 -= 1 0. FCC Warning =693 += 11. FCC Warning = 791 791 792 792 793 793 This device complies with part 15 of the FCC Rules.Operation is subject to the following two conditions: