From version < 10.1 >
edited by Edwin Chen
on 2023/04/09 08:27
To version < 20.1 >
edited by Edwin Chen
on 2023/04/09 10:07
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -156,8 +156,73 @@
156 156  [[image:image-20220522233300-8.png||_mstalt="428389" height="219" width="722"]]
157 157  
158 158  
159 -== 2.4 Uplink Payload   ( Fport~=2) ==
159 +== 2.4 Uplink Payload~-~-Device Status, (Fport~=5) ==
160 160  
161 +Users can use the downlink command(**0x26 01**) to ask LHT65N-PIR to send device configure detail, include device configure status. LHT65N-PIR will uplink a payload via FPort=5 to server.
162 +
163 +The Payload format is as below.
164 +
165 +|(% colspan="6" %)**Device Status (FPORT=5)**
166 +|**Size (bytes)**|**1**|**2**|**1**|**1**|**2**
167 +|**Value**|Sensor Model|Firmware Version|Frequency Band|Sub-band|BAT
168 +
169 +Example parse in TTNv3
170 +
171 +[[image:1675144504430-490.png]]
172 +
173 +**Sensor Model**: For LHT65N-PIR, this value is 0x1A
174 +
175 +**Firmware Version**: 0x0100, Means: v1.0.0 version
176 +
177 +**Frequency Band**:
178 +
179 +*0x01: EU868
180 +
181 +*0x02: US915
182 +
183 +*0x03: IN865
184 +
185 +*0x04: AU915
186 +
187 +*0x05: KZ865
188 +
189 +*0x06: RU864
190 +
191 +*0x07: AS923
192 +
193 +*0x08: AS923-1
194 +
195 +*0x09: AS923-2
196 +
197 +*0x0a: AS923-3
198 +
199 +*0x0b: CN470
200 +
201 +*0x0c: EU433
202 +
203 +*0x0d: KR920
204 +
205 +*0x0e: MA869
206 +
207 +**Sub-Band**:
208 +
209 +AU915 and US915:value 0x00 ~~ 0x08
210 +
211 +CN470: value 0x0B ~~ 0x0C
212 +
213 +Other Bands: Always 0x00
214 +
215 +**Battery Info**:
216 +
217 +Check the battery voltage.
218 +
219 +Ex1: 0x0B45 = 2885mV
220 +
221 +Ex2: 0x0B49 = 2889mV
222 +
223 +
224 +== 2.5 Uplink Payload, Sensor Data  ( Fport~=2) ==
225 +
161 161  The uplink payload includes totally 11 bytes. Uplink packets use FPORT=2 and (% style="color:#4f81bd" %)**every 20 minutes**(%%) send one uplink by default.
162 162  
163 163  After each uplink, the (% style="color:blue" %)**BLUE LED**(%%) will blink once.
... ... @@ -199,7 +199,7 @@
199 199  * The 8^^th^^ byte: Alarm Bit (if this uplink is from periodically or movement)
200 200  * The 9^^th^^ ~~ 11^^st^^  byte: Movement Detect Count.
201 201  
202 -=== 2.4.1 Decoder in TTN V3 ===
267 +=== 2.5.1 Decoder in TTN V3 ===
203 203  
204 204  
205 205  When the uplink payload arrives TTNv3, it shows HEX format and not friendly to read. We can add LHT65N-PIR decoder in TTNv3 for friendly reading.
... ... @@ -210,7 +210,7 @@
210 210  [[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220522234118-10.png||_mstalt="451464" height="353" width="729"]]
211 211  
212 212  
213 -=== 2.4.2 BAT-Battery Info ===
278 +=== 2.5.2 BAT-Battery Info ===
214 214  
215 215  
216 216  These two bytes of BAT include the battery state and the actually voltage
... ... @@ -226,9 +226,8 @@
226 226  * BAT status=(0xcba4>>14)&0xFF=11(B),very good
227 227  * Battery Voltage =0xCBF6&0x3FFF=0x0BA4=2980mV
228 228  
229 -=== 2.4.3 Built-in Temperature ===
294 +=== 2.5.3 Built-in Temperature ===
230 230  
231 -
232 232  [[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220522235639-2.png||_mstalt="431756" height="138" width="722"]]
233 233  
234 234  * Temperature:  0x0ABB/100=27.47℃
... ... @@ -237,33 +237,55 @@
237 237  
238 238  * Temperature:  (0xF5C6-65536)/100=-26.18℃
239 239  
240 -=== 2.4.4 Built-in Humidity ===
304 +=== 2.5.4 Built-in Humidity ===
241 241  
242 242  [[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220522235639-4.png||_mstalt="432484" height="138" width="722"]]
243 243  
244 244  * Humidity:    0x025C/10=60.4%
245 245  
246 -=== 2.4.5 Ext value ===
310 +=== 2.5.5 Ext value ===
247 247  
248 -==== 2.4.5.1 Ext~=0x0A, PIR Sensor ====
312 +==== 2.5.5.1 Ext~=0x0A, PIR Sensor ====
249 249  
250 -
251 251  [[image:image-20221224161634-2.png||height="138" width="851"]]
252 252  
253 253  
254 -* Illumination=0x005E=94 lux
317 +==== 2.5.5.2 Ext Value ====
255 255  
256 -The last 2 bytes of data are meaningless
319 +There are 4 bytes in Ext Value field.
257 257  
258 -[[image:image-20221224161725-3.png]]
321 +Bit0 of byte 8th shows if this uplink is generate by PIR activity.
259 259  
260 -* When the sensor is not connected or not connected properly, will show "NULL"
323 +(% border="1" cellspacing="4" style="background-color:#ffffcc; color:green; width:490px" %)
324 +|=(% style="width: 147px;" %)(((
325 +**The 8^^th^^ byte**
326 +)))|=(% style="width: 108px;" %)(((
327 +**Bit 1~~7**
328 +)))|=(% style="width: 228px;" %)(((
329 +**Bit 0**
330 +)))
331 +|(% style="width:147px" %)(((
332 +**Value**
333 +)))|(% style="width:108px" %)(((
334 +Reserve
335 +)))|(% style="width:228px" %)(((
336 +(((
337 +0: Normal Uplink
261 261  
262 - The last 2 bytes of data are meaningless
339 +1: Uplink by activity detected
340 +)))
341 +)))
263 263  
343 +**Note**: Uplink by activity is disable by default.
264 264  
265 -== 2.5 Show data on Datacake ==
266 266  
346 +The 9^^th^^ ~~ 11^^st^^  byte: Movement Detect Count.
347 +
348 +0x00 E5 09 : Total detect 58633 activity since end node start.
349 +
350 +
351 +== 2.6 Show data on Datacake ==
352 +
267 267  Datacake IoT platform provides a human-friendly interface to show the sensor data, once we have sensor data in TTN V3, we can use Datacake to connect to TTN V3 and see the data in Datacake. Below are the steps:
268 268  
269 269  (% style="color:blue" %)**Step 1**(%%): Be sure that your device is programmed and properly connected to the LoRaWAN network.
... ... @@ -272,7 +272,7 @@
272 272  
273 273  Add Datacake:
274 274  
275 -[[image:image-20220523000825-7.png||_mstalt="429884" height="262" width="583"]]
361 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220523000825-7.png||_mstalt="429884" height="262" width="583"]]
276 276  
277 277  
278 278  
... ... @@ -279,20 +279,20 @@
279 279  Select default key as Access Key:
280 280  
281 281  
282 -[[image:image-20220523000825-8.png||_mstalt="430248" height="453" width="406"]]
368 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220523000825-8.png||_mstalt="430248" height="453" width="406"]]
283 283  
284 284  
285 285  In Datacake console ([[https:~~/~~/datacake.co/>>url:https://datacake.co/]]) , add LHT65 device.
286 286  
287 287  
288 -[[image:image-20221224161935-5.png||height="523" width="409"]]
374 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20221224161935-5.png||height="523" width="409"]]
289 289  
290 290  
291 -[[image:image-20221224161957-6.png||height="306" width="852"]]
377 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20221224161957-6.png||height="306" width="852"]]
292 292  
293 293  
294 294  
295 -== 2.8 LED Indicator ==
381 +== 2.7 LED Indicator ==
296 296  
297 297  
298 298  The LHT65N-PIR has a triple color LED which for easy showing different stage .
... ... @@ -306,18 +306,20 @@
306 306  * RED LED when external sensor is not connected
307 307  * For each success downlink, the PURPLE LED will blink once
308 308  
309 -== 2.9 installation ==
395 +== 2.8 installation ==
310 310  
397 +~1. Don't install LHT65N-PIR outdoor or place where will get wet
311 311  
312 -[[image:image-20220516231650-1.png||_mstalt="428597" height="436" width="428"]]
399 +2. Towards the PIR probe to the place where need to monitor activity.
313 313  
314 314  
402 +
315 315  = 3. Sensors and Accessories =
316 316  
317 317  == 3.1 E2 Extension Cable ==
318 318  
319 319  
320 -[[image:image-20220619092222-1.png||_mstalt="429533" height="182" width="188"]][[image:image-20220619092313-2.png||_mstalt="430222" height="182" width="173"]]
408 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220619092222-1.png||_mstalt="429533" height="182" width="188"]][[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220619092313-2.png||_mstalt="430222" height="182" width="173"]]
321 321  
322 322  
323 323  **1m long breakout cable for LHT65N-E5. Features:**
... ... @@ -329,59 +329,41 @@
329 329  Update firmware for LHT65N-PIR
330 330  )))
331 331  
332 -[[image:image-20220619092421-3.png||_mstalt="430547" height="371" width="529"]]
420 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220619092421-3.png||_mstalt="430547" height="371" width="529"]]
333 333  
334 334  
335 -= 4. Configure LHT65N-PIR via AT command or LoRaWAN downlink =
423 += 4. Configure LHT65N-PIR =
336 336  
425 +== 4.1 Configure Methods: ==
337 337  
338 -(((
339 -Use can configure LHT65N-E5 via AT Command or LoRaWAN Downlink.
340 -)))
341 341  
342 -* (((
343 -AT Command Connection: See [[FAQ>>||anchor="H6.FAQ"]].
344 -)))
428 +LHT65N-PIR supports below configure method:
345 345  
346 -* (((
347 -LoRaWAN Downlink instruction for different platforms: [[IoT LoRaWAN Server>>doc:Main.WebHome]]
348 -)))
430 +* AT Command via UART Connection : See [[FAQ>>path:#H7.FAQ]].
431 +* LoRaWAN Downlink.  Instruction for different platforms: See [[IoT LoRaWAN Server>>url:http://wiki.dragino.com/xwiki/bin/view/Main/]] section.
349 349  
350 -(((
351 -There are two kinds of commands to configure LHT65N-E5, they are:
352 -)))
433 +== 4.2 General Commands ==
353 353  
354 -* (((
355 -(% style="color:#4f81bd" %)**General Commands**.
356 -)))
357 357  
358 -(((
359 359  These commands are to configure:
360 -)))
361 361  
362 -1. (((
363 -General system settings like: uplink interval.
364 -)))
365 -1. (((
366 -LoRaWAN protocol & radio-related commands.
367 -)))
438 +* General system settings like: uplink interval.
439 +* LoRaWAN protocol & radio related command.
368 368  
369 -(((
370 -They are the same for all Dragino Devices which supports DLWS-005 LoRaWAN Stack(Note~*~*). These commands can be found on the wiki: [[End Device Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
371 -)))
441 +They are same for all Dragino Devices which support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki:
372 372  
373 -* (((
374 -(% style="color:#4f81bd" %)**Commands special design for LHT65N-E5**
375 -)))
443 +[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]]
376 376  
377 -(((
378 -These commands are only valid for LHT65N-E5, as below:
379 -)))
380 380  
446 +== 4.3 Commands special design for LHT65N-PIR ==
381 381  
382 -== 4.1 Set Transmit Interval Time ==
383 383  
449 +These commands only valid for LHT65N-PIR, as below:
384 384  
451 +
452 +=== 4.3.1 Set Transmit Interval Time ===
453 +
454 +
385 385  Feature: Change LoRaWAN End Node Transmit Interval.
386 386  
387 387  
... ... @@ -390,7 +390,7 @@
390 390  [[image:image-20220523150701-2.png||_mstalt="427453"]]
391 391  
392 392  
393 -(% style="color:#4f81bd" %)**Downlink Command: 0x01**
463 +(% style="color:#4f81bd" %)**Downlink Payload: 0x01**
394 394  
395 395  Format: Command Code (0x01) followed by 3 bytes time value.
396 396  
... ... @@ -400,9 +400,18 @@
400 400  
401 401  * **Example 2**: Downlink Payload: 0100003C  ~/~/ Set Transmit Interval (TDC) = 60 seconds
402 402  
403 -== 4.2 Currently only supports E5 ==
473 +=== 4.3.2 Get Device Status ===
404 404  
475 +Send a LoRaWAN downlink to ask device send Alarm settings.
405 405  
477 +* (% style="color:#4f81bd" %)**Downlink Payload**(%%)**:  **0x26 01
478 +
479 +Sensor will upload Device Status via FPORT=5. See payload section for detail.
480 +
481 +
482 +=== 4.3.3 Set Password ===
483 +
484 +
406 406  Feature: Set device password, max 9 digits
407 407  
408 408  
... ... @@ -426,7 +426,7 @@
426 426  
427 427  * 0xA205: Set external sensor type to E5
428 428  
429 -== 4.3 Set to sleep mode ==
508 +=== 4.3.4 Set to sleep mode ===
430 430  
431 431  
432 432  Feature: Set device to sleep mode
... ... @@ -443,206 +443,60 @@
443 443  
444 444  * There is no downlink command to set to Sleep mode.
445 445  
446 -= 5. Battery & How to replace =
525 +=== 4.3.5 Set UOA (Uplink on Activity) ===
447 447  
448 -== 5.1 Battery Type ==
527 +Feature: Enable / Disable Uplink on Activity
449 449  
529 +* **AT+UOA=0**  : Disable UoA
530 +* **AT+UOA=1,2** :  Enable UoA , Calm Down Time: 2 minutes. If device already send a uplink on activity, it will not send another uplink on activiy in 2 minutes, even detect activity.
450 450  
451 -(((
452 -LHT65N-E5 is equipped with a 2400mAH Li-MnO2 (CR17505) battery . The battery is an un-rechargeable battery with low discharge rate targeting for up to 8~~10 years use. This type of battery is commonly used in IoT devices for long-term running, such as water meters.
453 -)))
532 +Notice: Calm Down time range is 1 ~~ 65535 minutes. If user set Calm Down time to low value, such as 1 minute, the sensor might send uplink very frequenctly and battery drain fast.
454 454  
455 -(((
456 -The discharge curve is not linear so can't simply use percentage to show the battery level. Below is the battery performance.
534 +(% style="color:#4f81bd" %)**AT Command: AT+UOA**
457 457  
458 458  
459 -[[image:image-20220515075034-1.png||_mstalt="428961" height="208" width="644"]]
460 -)))
537 +(% style="color:#4f81bd" %)**Downlink Command:  **(% class="mark" %)**xxxxxxx**
461 461  
462 -The minimum Working Voltage for the LHT65N-E5 is ~~ 2.5v. When battery is lower than 2.6v, it is time to change the battery.
463 -
464 464  
465 -== 5.2 Replace Battery ==
540 += 5. Battery & Power Consumption =
466 466  
542 +LHT65N-PIR use **CR17450** battery pack. See below link for detail information about the battery info and how to replace.
467 467  
468 -LHT65N-E5 has two screws on the back, Unscrew them, and changing the battery inside is ok. The battery is a general CR17450 battery (3.0v). Any brand should be ok.
544 +[[**Battery Info & Power Consumption Analyze**>>url:http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20calculate%20the%20battery%20life%20of%20Dragino%20sensors%3F/]] .
469 469  
470 -[[image:image-20220515075440-2.png||_mstalt="429546" height="338" width="272"]][[image:image-20220515075625-3.png||_mstalt="431574" height="193" width="257"]]
471 471  
547 += 6. OTA firmware update =
472 472  
473 -== 5.3 Battery Life Analyze ==
549 +Please see this link for how to do OTA firmware update: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/]]
474 474  
475 475  
476 -(((
477 -Dragino battery-powered products are all run in Low Power mode. User can check the guideline from this link to calculate the estimated battery life:
478 -[[https:~~/~~/www.dragino.com/downloads/downloads/LoRa_End_Node/Battery_Analyze/DRAGINO_Battery_Life_Guide.pdf>>https://www.dragino.com/downloads/downloads/LoRa_End_Node/Battery_Analyze/DRAGINO_Battery_Life_Guide.pdf]]
479 -)))
552 += 7. FAQ =
480 480  
554 +== 7.1 How to use AT Command? ==
481 481  
482 -(((
483 -A full detail test report for LHT65N-E5 on different frequency can be found at : [[https:~~/~~/www.dropbox.com/sh/r2i3zlhsyrpavla/AAB1sZw3mdT0K7XjpHCITt13a?dl=0>>https://www.dropbox.com/sh/r2i3zlhsyrpavla/AAB1sZw3mdT0K7XjpHCITt13a?dl=0]]
484 -)))
485 485  
486 -
487 -= 6. FAQ =
488 -
489 -== 6.1 How to use AT Command? ==
490 -
491 -
492 492  LHT65N-E5 supports AT Command set.User can use a USB to TTL adapter plus the Program Cable to connect to LHT65 for using AT command, as below.
493 493  
494 494  
495 -[[image:image-20220615153355-1.png||_mstalt="430222"]]
560 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615153355-1.png||_mstalt="430222"]]
496 496  
497 497  
498 498  
499 -[[image:1655802313617-381.png||_mstalt="293917"]]
564 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@1655802313617-381.png||_mstalt="293917"]]
500 500  
501 501  
502 -
503 -(((
504 504  In PC, User needs to set serial tool(such as [[**putty**>>https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to (% style="color:green" %)**9600** (%%)to access to access serial console for LHT65N-E5. The AT commands are disable by default and need to enter password (default:(% style="color:green" %)**123456**(% style="color:red" %))(%%) to active it. Timeout to input AT Command is 5 min, after 5-minute, user need to input password again. User can use AT+DISAT command to disable AT command before timeout.
505 -)))
506 506  
507 -[[image:image-20220615154519-3.png||_mstalt="431925" height="672" width="807"]]
569 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615154519-3.png||_mstalt="431925" height="672" width="807"]]
508 508  
509 -AT Command List is as below:
510 510  
511 -AT+<CMD>? :  Help on <CMD>
512 512  
513 -AT+<CMD> Run <CMD>
573 +== 7.2 Where to use AT commands and Downlink commands ==
514 514  
515 -AT+<CMD>=<value> :  Set the value
516 516  
517 -AT+<CMD>=? :  Get the value
518 -
519 -AT+DEBUG:  Set more info output
520 -
521 -ATZ:  Trig a reset of the MCU
522 -
523 -AT+FDR:  Reset Parameters to Factory Default, Keys Reserve
524 -
525 -AT+DEUI:  Get or Set the Device EUI
526 -
527 -AT+DADDR:  Get or Set the Device Address
528 -
529 -AT+APPKEY:  Get or Set the Application Key
530 -
531 -AT+NWKSKEY:  Get or Set the Network Session Key
532 -
533 -AT+APPSKEY:  Get or Set the Application Session Key
534 -
535 -AT+APPEUI:  Get or Set the Application EUI
536 -
537 -AT+ADR:  Get or Set the Adaptive Data Rate setting. (0: off, 1: on)
538 -
539 -AT+TXP:  Get or Set the Transmit Power (0-5, MAX:0, MIN:5, according to LoRaWAN Spec)
540 -
541 -AT+DR:  Get or Set the Data Rate. (0-7 corresponding to DR_X)
542 -
543 -AT+DCS:  Get or Set the ETSI Duty Cycle setting - 0=disable, 1=enable - Only for testing
544 -
545 -AT+PNM:  Get or Set the public network mode. (0: off, 1: on)
546 -
547 -AT+RX2FQ:  Get or Set the Rx2 window frequency
548 -
549 -AT+RX2DR:  Get or Set the Rx2 window data rate (0-7 corresponding to DR_X)
550 -
551 -AT+RX1DL:  Get or Set the delay between the end of the Tx and the Rx Window 1 in ms
552 -
553 -AT+RX2DL:  Get or Set the delay between the end of the Tx and the Rx Window 2 in ms
554 -
555 -AT+JN1DL:  Get or Set the Join Accept Delay between the end of the Tx and the Join Rx Window 1 in ms
556 -
557 -AT+JN2DL:  Get or Set the Join Accept Delay between the end of the Tx and the Join Rx Window 2 in ms
558 -
559 -AT+NJM:  Get or Set the Network Join Mode. (0: ABP, 1: OTAA)
560 -
561 -AT+NWKID:  Get or Set the Network ID
562 -
563 -AT+FCU:  Get or Set the Frame Counter Uplink
564 -
565 -AT+FCD:  Get or Set the Frame Counter Downlink
566 -
567 -AT+CLASS:  Get or Set the Device Class
568 -
569 -AT+JOIN:  Join network
570 -
571 -AT+NJS:  Get the join status
572 -
573 -AT+SENDB:  Send hexadecimal data along with the application port
574 -
575 -AT+SEND:  Send text data along with the application port
576 -
577 -AT+RECVB:  Print last received data in binary format (with hexadecimal values)
578 -
579 -AT+RECV:  Print last received data in raw format
580 -
581 -AT+VER:  Get current image version and Frequency Band
582 -
583 -AT+CFM:  Get or Set the confirmation mode (0-1)
584 -
585 -AT+CFS:  Get confirmation status of the last AT+SEND (0-1)
586 -
587 -AT+SNR:  Get the SNR of the last received packet
588 -
589 -AT+RSSI:  Get the RSSI of the last received packet
590 -
591 -AT+TDC:  Get or set the application data transmission interval in ms
592 -
593 -AT+PORT:  Get or set the application port
594 -
595 -AT+DISAT:  Disable AT commands
596 -
597 -AT+PWORD: Set password, max 9 digits
598 -
599 -AT+CHS:  Get or Set Frequency (Unit: Hz) for Single Channel Mode
600 -
601 -AT+CHE:  Get or Set eight channels mode,Only for US915,AU915,CN470
602 -
603 -AT+PDTA:  Print the sector data from start page to stop page
604 -
605 -AT+PLDTA:  Print the last few sets of data
606 -
607 -AT+CLRDTA:  Clear the storage, record position back to 1st
608 -
609 -AT+SLEEP:  Set sleep mode
610 -
611 -AT+EXT:  Get or Set external sensor model
612 -
613 -AT+BAT:  Get the current battery voltage in mV
614 -
615 -AT+CFG:  Print all configurations
616 -
617 -AT+WMOD:  Get or Set Work Mode
618 -
619 -AT+ARTEMP:  Get or set the internal Temperature sensor alarm range
620 -
621 -AT+CITEMP:  Get or set the internal Temperature sensor collection interval in min
622 -
623 -AT+SETCNT:  Set the count at present
624 -
625 -AT+RJTDC:  Get or set the ReJoin data transmission interval in min
626 -
627 -AT+RPL:  Get or set response level
628 -
629 -AT+TIMESTAMP:  Get or Set UNIX timestamp in second
630 -
631 -AT+LEAPSEC:  Get or Set Leap Second
632 -
633 -AT+SYNCMOD:  Get or Set time synchronization method
634 -
635 -AT+SYNCTDC:  Get or set time synchronization interval in day
636 -
637 -AT+PID:  Get or set the PID
638 -
639 -
640 -== 6.2 Where to use AT commands and Downlink commands ==
641 -
642 -
643 643  **AT commands:**
644 644  
645 -[[image:image-20220620153708-1.png||_mstalt="429806" height="603" width="723"]]
578 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220620153708-1.png||_mstalt="429806" height="603" width="723"]]
646 646  
647 647  
648 648  **Downlink commands:**
... ... @@ -651,13 +651,13 @@
651 651  
652 652  (% style="color:blue" %)**TTN:**
653 653  
654 -[[image:image-20220615092124-2.png||_mstalt="429221" height="649" width="688"]]
587 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615092124-2.png||_mstalt="429221" height="649" width="688"]]
655 655  
656 656  
657 657  
658 658  (% style="color:blue" %)**Helium:**
659 659  
660 -[[image:image-20220615092551-3.png||_mstalt="430794" height="423" width="835"]]
593 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615092551-3.png||_mstalt="430794" height="423" width="835"]]
661 661  
662 662  
663 663  
... ... @@ -664,56 +664,49 @@
664 664  (% style="color:blue" %)**Chirpstack: The downlink window will not be displayed until the network is accessed**
665 665  
666 666  
667 -[[image:image-20220615094850-6.png||_mstalt="433082"]]
600 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615094850-6.png||_mstalt="433082"]]
668 668  
669 669  
670 -[[image:image-20220615094904-7.png||_mstalt="433485" height="281" width="911"]]
603 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615094904-7.png||_mstalt="433485" height="281" width="911"]]
671 671  
672 672  
673 673  
674 674  (% style="color:blue" %)**Aws:**
675 675  
676 -[[image:image-20220615092939-4.png||_mstalt="434460" height="448" width="894"]]
609 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615092939-4.png||_mstalt="434460" height="448" width="894"]]
677 677  
678 678  
679 679  == 6.3 How to change the uplink interval? ==
680 680  
681 -
682 682  Please see this link: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/How%20to%20set%20the%20transmit%20time%20interval/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20set%20the%20transmit%20time%20interval/||_mstmutation="1" style="background-color: rgb(255, 255, 255);"]]
683 683  
616 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615154519-3.png||_mstalt="431925" height="672" width="807"]]
684 684  
685 685  
686 -[[image:image-20220615154519-3.png||_mstalt="431925" height="672" width="807"]]
619 +== 7.4 How to use TTL-USB to connect PC to upgrade firmware? ==
687 687  
621 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615153355-1.png||_mstalt="430222"]]
688 688  
689 -== 6.4 How to use TTL-USB to connect PC to upgrade firmware? ==
690 -
691 -
692 -[[image:image-20220615153355-1.png||_mstalt="430222"]]
693 -
694 -
695 695  (% style="color:blue" %)**Step1**(%%): Install TremoProgrammer  first.
696 696  
697 -[[image:image-20220615170542-5.png||_mstalt="430638"]]
625 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615170542-5.png||_mstalt="430638"]]
698 698  
699 -
700 -
701 701  (% _mstmutation="1" style="color:blue" %)**Step2**(%%):wiring method.(% style="display:none" %)
702 702  
703 703  First connect the four lines;(% style="display:none" %)
704 704  
705 -[[image:image-20220621170938-1.png||_mstalt="431340" height="413" width="419"]],(% style="display:none" %)
631 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220621170938-1.png||_mstalt="431340" height="413" width="419"]],(% style="display:none" %)
706 706  
707 707  
708 708  Then use DuPont cable to short circuit port3 and port1, and then release them, so that the device enters bootlaod mode.
709 709  
710 -[[image:image-20220621170938-2.png||_mstalt="431704"]]
636 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220621170938-2.png||_mstalt="431704"]]
711 711  
712 712  
713 713  
714 714  (% style="color:blue" %)**Step3:**(%%)Select the device port to be connected, baud rate and bin file to be downloaded.
715 715  
716 -[[image:image-20220615171334-6.png||_mstalt="431028"]]
642 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615171334-6.png||_mstalt="431028"]]
717 717  
718 718  
719 719  Click the (% style="color:blue" %)**start**(%%) button to start the firmware upgrade.
... ... @@ -721,7 +721,7 @@
721 721  
722 722  When this interface appears, it indicates that the download has been completed.
723 723  
724 -[[image:image-20220620160723-8.png||_mstalt="430703"]]
650 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220620160723-8.png||_mstalt="430703"]]
725 725  
726 726  
727 727  Finally, unplug the DuPont cable on port4, and then use the DuPont cable to short circuit port3 and port1 to reset the device.
... ... @@ -728,10 +728,10 @@
728 728  
729 729  
730 730  
731 -[[image:image-20220615154519-3.png||_mstalt="431925" height="672" width="807"]]
657 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615154519-3.png||_mstalt="431925" height="672" width="807"]]
732 732  
733 733  
734 -= 7. Order Info =
660 += 8. Order Info =
735 735  
736 736  
737 737  Part Number: (% style="color:#4f81bd" %)** LHT65N-PIR-XX**
... ... @@ -747,7 +747,7 @@
747 747  * (% style="color:#4f81bd" %)** **(% _mstmutation="1" style="color:red" %)**IN865**(%%): LoRaWAN IN865 band
748 748  * (% style="color:#4f81bd" %)** **(% _mstmutation="1" style="color:red" %)**CN470**(%%): LoRaWAN CN470 band
749 749  
750 -= 8. Packing Info =
676 += 9. Packing Info =
751 751  
752 752  
753 753  **Package Includes**:
... ... @@ -759,12 +759,12 @@
759 759  * Device Size:  10 x 10 x 3.5 mm
760 760  * Device Weight: 120.5g
761 761  
762 -= 9. Reference material =
688 += 10. Reference material =
763 763  
764 764  
765 765  * [[Datasheet, photos, decoder, firmware>>https://www.dropbox.com/sh/una19zsni308dme/AACOKp6J2RF5TMlKWT5zU3RTa?dl=0]]
766 766  
767 -= 10. FCC Warning =
693 += 11. FCC Warning =
768 768  
769 769  
770 770  This device complies with part 15 of the FCC Rules.Operation is subject to the following two conditions:
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0