Changes for page LHT65N-PIR Temperature/Humidity/PIR Motion Sensor User Manual
Last modified by Xiaoling on 2025/06/10 09:17
From version 10.1
edited by Edwin Chen
on 2023/04/09 08:27
on 2023/04/09 08:27
Change comment:
There is no comment for this version
To version 17.1
edited by Edwin Chen
on 2023/04/09 09:32
on 2023/04/09 09:32
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -228,7 +228,6 @@ 228 228 229 229 === 2.4.3 Built-in Temperature === 230 230 231 - 232 232 [[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220522235639-2.png||_mstalt="431756" height="138" width="722"]] 233 233 234 234 * Temperature: 0x0ABB/100=27.47℃ ... ... @@ -247,21 +247,43 @@ 247 247 248 248 ==== 2.4.5.1 Ext~=0x0A, PIR Sensor ==== 249 249 250 - 251 251 [[image:image-20221224161634-2.png||height="138" width="851"]] 252 252 253 253 254 - * Illumination=0x005E=94 lux252 +==== 2.4.5.2 Ext Value ==== 255 255 256 -The last2bytesofdataaremeaningless254 +There are 4 bytes in Ext Value field. 257 257 258 - [[image:image-20221224161725-3.png]]256 +Bit0 of byte 8th shows if this uplink is generate by PIR activity. 259 259 260 -* When the sensor is not connected or not connected properly, will show "NULL" 258 +(% border="1" cellspacing="4" style="background-color:#ffffcc; color:green; width:490px" %) 259 +|=(% style="width: 147px;" %)((( 260 +**The 8^^th^^ byte** 261 +)))|=(% style="width: 108px;" %)((( 262 +**Bit 1~~7** 263 +)))|=(% style="width: 228px;" %)((( 264 +**Bit 0** 265 +))) 266 +|(% style="width:147px" %)((( 267 +**Value** 268 +)))|(% style="width:108px" %)((( 269 +Reserve 270 +)))|(% style="width:228px" %)((( 271 +((( 272 +0: Normal Uplink 261 261 262 - The last 2 bytes of data are meaningless 274 +1: Uplink by activity detected 275 +))) 276 +))) 263 263 278 +**Note**: Uplink by activity is disable by default. 264 264 280 + 281 +The 9^^th^^ ~~ 11^^st^^ byte: Movement Detect Count. 282 + 283 +0x00 E5 09 : Total detect 58633 activity since end node start. 284 + 285 + 265 265 == 2.5 Show data on Datacake == 266 266 267 267 Datacake IoT platform provides a human-friendly interface to show the sensor data, once we have sensor data in TTN V3, we can use Datacake to connect to TTN V3 and see the data in Datacake. Below are the steps: ... ... @@ -272,7 +272,7 @@ 272 272 273 273 Add Datacake: 274 274 275 -[[image:image-20220523000825-7.png||_mstalt="429884" height="262" width="583"]] 296 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220523000825-7.png||_mstalt="429884" height="262" width="583"]] 276 276 277 277 278 278 ... ... @@ -279,16 +279,16 @@ 279 279 Select default key as Access Key: 280 280 281 281 282 -[[image:image-20220523000825-8.png||_mstalt="430248" height="453" width="406"]] 303 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220523000825-8.png||_mstalt="430248" height="453" width="406"]] 283 283 284 284 285 285 In Datacake console ([[https:~~/~~/datacake.co/>>url:https://datacake.co/]]) , add LHT65 device. 286 286 287 287 288 -[[image:image-20221224161935-5.png||height="523" width="409"]] 309 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20221224161935-5.png||height="523" width="409"]] 289 289 290 290 291 -[[image:image-20221224161957-6.png||height="306" width="852"]] 312 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20221224161957-6.png||height="306" width="852"]] 292 292 293 293 294 294 ... ... @@ -308,16 +308,18 @@ 308 308 309 309 == 2.9 installation == 310 310 332 +~1. Don't install LHT65N-PIR outdoor or place where will get wet 311 311 312 - [[image:image-20220516231650-1.png||_mstalt="428597"height="436"width="428"]]334 +2. Towards the PIR probe to the place where need to monitor activity. 313 313 314 314 337 + 315 315 = 3. Sensors and Accessories = 316 316 317 317 == 3.1 E2 Extension Cable == 318 318 319 319 320 -[[image:image-20220619092222-1.png||_mstalt="429533" height="182" width="188"]][[image:image-20220619092313-2.png||_mstalt="430222" height="182" width="173"]] 343 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220619092222-1.png||_mstalt="429533" height="182" width="188"]][[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220619092313-2.png||_mstalt="430222" height="182" width="173"]] 321 321 322 322 323 323 **1m long breakout cable for LHT65N-E5. Features:** ... ... @@ -329,59 +329,42 @@ 329 329 Update firmware for LHT65N-PIR 330 330 ))) 331 331 332 -[[image:image-20220619092421-3.png||_mstalt="430547" height="371" width="529"]] 355 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220619092421-3.png||_mstalt="430547" height="371" width="529"]] 333 333 334 334 335 -= 4. Configure LHT65N-PIR via AT command or LoRaWAN downlink=358 += 4. Configure LHT65N-PIR = 336 336 360 +== 4.1 Configure Methods: == 337 337 338 -((( 339 -Use can configure LHT65N-E5 via AT Command or LoRaWAN Downlink. 340 -))) 341 341 342 -* ((( 343 -AT Command Connection: See [[FAQ>>||anchor="H6.FAQ"]]. 344 -))) 363 +LHT65N-PIR supports below configure method: 345 345 346 -* ((( 347 -LoRaWAN Downlink instruction for different platforms: [[IoT LoRaWAN Server>>doc:Main.WebHome]] 348 -))) 365 +* AT Command via UART Connection : See [[FAQ>>path:#H7.FAQ]]. 366 +* LoRaWAN Downlink. Instruction for different platforms: See [[IoT LoRaWAN Server>>url:http://wiki.dragino.com/xwiki/bin/view/Main/]] section. 349 349 350 -((( 351 -There are two kinds of commands to configure LHT65N-E5, they are: 352 -))) 353 353 354 -* ((( 355 -(% style="color:#4f81bd" %)**General Commands**. 356 -))) 369 +== 4.2 General Commands == 357 357 358 - (((371 + 359 359 These commands are to configure: 360 -))) 361 361 362 -1. ((( 363 -General system settings like: uplink interval. 364 -))) 365 -1. ((( 366 -LoRaWAN protocol & radio-related commands. 367 -))) 374 +* General system settings like: uplink interval. 375 +* LoRaWAN protocol & radio related command. 368 368 369 -((( 370 -They are the same for all Dragino Devices which supports DLWS-005 LoRaWAN Stack(Note~*~*). These commands can be found on the wiki: [[End Device Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] 371 -))) 377 +They are same for all Dragino Devices which support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki: 372 372 373 -* ((( 374 -(% style="color:#4f81bd" %)**Commands special design for LHT65N-E5** 375 -))) 379 +[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]] 376 376 377 -((( 378 -These commands are only valid for LHT65N-E5, as below: 379 -))) 380 380 382 +== 4.3 Commands special design for LHT65N-PIR == 381 381 382 -== 4.1 Set Transmit Interval Time == 383 383 385 +These commands only valid for LHT65N-PIR, as below: 384 384 387 + 388 +=== 4.3.1 Set Transmit Interval Time === 389 + 390 + 385 385 Feature: Change LoRaWAN End Node Transmit Interval. 386 386 387 387 ... ... @@ -390,7 +390,7 @@ 390 390 [[image:image-20220523150701-2.png||_mstalt="427453"]] 391 391 392 392 393 -(% style="color:#4f81bd" %)**Downlink Command: 0x01**399 +(% style="color:#4f81bd" %)**Downlink Payload: 0x01** 394 394 395 395 Format: Command Code (0x01) followed by 3 bytes time value. 396 396 ... ... @@ -400,9 +400,19 @@ 400 400 401 401 * **Example 2**: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 402 402 403 -== 4.2 Currently only supports E5 == 404 404 410 +=== 4.3.2 Get Device Status === 405 405 412 +Send a LoRaWAN downlink to ask device send Alarm settings. 413 + 414 +* (% style="color:#4f81bd" %)**Downlink Payload**(%%)**: **0x26 01 415 + 416 +Sensor will upload Device Status via FPORT=5. See payload section for detail. 417 + 418 + 419 +=== 4.3.3 Set Password === 420 + 421 + 406 406 Feature: Set device password, max 9 digits 407 407 408 408 ... ... @@ -426,9 +426,10 @@ 426 426 427 427 * 0xA205: Set external sensor type to E5 428 428 429 -== 4.3 Set to sleep mode == 430 430 446 +=== 4.3.4 Set to sleep mode === 431 431 448 + 432 432 Feature: Set device to sleep mode 433 433 434 434 * **AT+Sleep=0** : Normal working mode, device will sleep and use lower power when there is no LoRa message ... ... @@ -443,47 +443,33 @@ 443 443 444 444 * There is no downlink command to set to Sleep mode. 445 445 446 -= 5. Battery & How to replace = 447 447 448 -== 5.1BatteryType==464 +=== 4.3.5 Set UOA (Uplink on Activity) === 449 449 466 +Feature: Enable / Disable Uplink on Activity 450 450 451 -((( 452 -LHT65N-E5 is equipped with a 2400mAH Li-MnO2 (CR17505) battery . The battery is an un-rechargeable battery with low discharge rate targeting for up to 8~~10 years use. This type of battery is commonly used in IoT devices for long-term running, such as water meters. 453 -))) 468 +* **AT+UOA=0** : Disable UoA 469 +* **AT+UOA=1,2** : Enable UoA , Calm Down Time: 2 minutes. If device already send a uplink on activity, it will not send another uplink on activiy in 2 minutes, even detect activity. 454 454 455 -((( 456 -The discharge curve is not linear so can't simply use percentage to show the battery level. Below is the battery performance. 457 457 472 +(% style="color:#4f81bd" %)**AT Command: AT+UOA** 458 458 459 -[[image:image-20220515075034-1.png||_mstalt="428961" height="208" width="644"]] 460 -))) 461 461 462 -The minimum Working Voltage for the LHT65N-E5 is ~~ 2.5v. When battery is lower than 2.6v, it is time to change the battery. 463 - 475 +(% style="color:#4f81bd" %)**Downlink Command: (% class="mark" %)xxxxxxx(%%)** 464 464 465 -== 5.2 Replace Battery == 466 466 478 += 5. Battery & Power Consumption = 467 467 468 -LHT65N- E5hastwo screwsontheback,Unscrewthem,and changingthe batteryinsidesok. The batteryisageneralCR17450battery(3.0v). Anybrandshouldbeok.480 +LHT65N-PIR use **CR17450** battery pack. See below link for detail information about the battery info and how to replace. 469 469 470 -[[ image:image-20220515075440-2.png||_mstalt="429546" height="338"width="272"]][[image:image-20220515075625-3.png||_mstalt="431574"height="193" width="257"]]482 +[[**Battery Info & Power Consumption Analyze**>>url:http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20calculate%20the%20battery%20life%20of%20Dragino%20sensors%3F/]] . 471 471 472 472 473 -= =5.3BatteryLifeAnalyze ==485 += 6. OTA firmware update = 474 474 487 +Please see this link for how to do OTA firmware update: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/]] 475 475 476 -((( 477 -Dragino battery-powered products are all run in Low Power mode. User can check the guideline from this link to calculate the estimated battery life: 478 -[[https:~~/~~/www.dragino.com/downloads/downloads/LoRa_End_Node/Battery_Analyze/DRAGINO_Battery_Life_Guide.pdf>>https://www.dragino.com/downloads/downloads/LoRa_End_Node/Battery_Analyze/DRAGINO_Battery_Life_Guide.pdf]] 479 -))) 480 480 481 - 482 -((( 483 -A full detail test report for LHT65N-E5 on different frequency can be found at : [[https:~~/~~/www.dropbox.com/sh/r2i3zlhsyrpavla/AAB1sZw3mdT0K7XjpHCITt13a?dl=0>>https://www.dropbox.com/sh/r2i3zlhsyrpavla/AAB1sZw3mdT0K7XjpHCITt13a?dl=0]] 484 -))) 485 - 486 - 487 487 = 6. FAQ = 488 488 489 489 == 6.1 How to use AT Command? == ... ... @@ -492,157 +492,25 @@ 492 492 LHT65N-E5 supports AT Command set.User can use a USB to TTL adapter plus the Program Cable to connect to LHT65 for using AT command, as below. 493 493 494 494 495 -[[image:image-20220615153355-1.png||_mstalt="430222"]] 498 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615153355-1.png||_mstalt="430222"]] 496 496 497 497 498 498 499 -[[image:1655802313617-381.png||_mstalt="293917"]] 502 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@1655802313617-381.png||_mstalt="293917"]] 500 500 501 501 502 - 503 -((( 504 504 In PC, User needs to set serial tool(such as [[**putty**>>https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to (% style="color:green" %)**9600** (%%)to access to access serial console for LHT65N-E5. The AT commands are disable by default and need to enter password (default:(% style="color:green" %)**123456**(% style="color:red" %))(%%) to active it. Timeout to input AT Command is 5 min, after 5-minute, user need to input password again. User can use AT+DISAT command to disable AT command before timeout. 505 -))) 506 506 507 -[[image:image-20220615154519-3.png||_mstalt="431925" height="672" width="807"]] 507 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615154519-3.png||_mstalt="431925" height="672" width="807"]] 508 508 509 -AT Command List is as below: 510 510 511 -AT+<CMD>? : Help on <CMD> 512 512 513 -AT+<CMD> : Run <CMD> 514 - 515 -AT+<CMD>=<value> : Set the value 516 - 517 -AT+<CMD>=? : Get the value 518 - 519 -AT+DEBUG: Set more info output 520 - 521 -ATZ: Trig a reset of the MCU 522 - 523 -AT+FDR: Reset Parameters to Factory Default, Keys Reserve 524 - 525 -AT+DEUI: Get or Set the Device EUI 526 - 527 -AT+DADDR: Get or Set the Device Address 528 - 529 -AT+APPKEY: Get or Set the Application Key 530 - 531 -AT+NWKSKEY: Get or Set the Network Session Key 532 - 533 -AT+APPSKEY: Get or Set the Application Session Key 534 - 535 -AT+APPEUI: Get or Set the Application EUI 536 - 537 -AT+ADR: Get or Set the Adaptive Data Rate setting. (0: off, 1: on) 538 - 539 -AT+TXP: Get or Set the Transmit Power (0-5, MAX:0, MIN:5, according to LoRaWAN Spec) 540 - 541 -AT+DR: Get or Set the Data Rate. (0-7 corresponding to DR_X) 542 - 543 -AT+DCS: Get or Set the ETSI Duty Cycle setting - 0=disable, 1=enable - Only for testing 544 - 545 -AT+PNM: Get or Set the public network mode. (0: off, 1: on) 546 - 547 -AT+RX2FQ: Get or Set the Rx2 window frequency 548 - 549 -AT+RX2DR: Get or Set the Rx2 window data rate (0-7 corresponding to DR_X) 550 - 551 -AT+RX1DL: Get or Set the delay between the end of the Tx and the Rx Window 1 in ms 552 - 553 -AT+RX2DL: Get or Set the delay between the end of the Tx and the Rx Window 2 in ms 554 - 555 -AT+JN1DL: Get or Set the Join Accept Delay between the end of the Tx and the Join Rx Window 1 in ms 556 - 557 -AT+JN2DL: Get or Set the Join Accept Delay between the end of the Tx and the Join Rx Window 2 in ms 558 - 559 -AT+NJM: Get or Set the Network Join Mode. (0: ABP, 1: OTAA) 560 - 561 -AT+NWKID: Get or Set the Network ID 562 - 563 -AT+FCU: Get or Set the Frame Counter Uplink 564 - 565 -AT+FCD: Get or Set the Frame Counter Downlink 566 - 567 -AT+CLASS: Get or Set the Device Class 568 - 569 -AT+JOIN: Join network 570 - 571 -AT+NJS: Get the join status 572 - 573 -AT+SENDB: Send hexadecimal data along with the application port 574 - 575 -AT+SEND: Send text data along with the application port 576 - 577 -AT+RECVB: Print last received data in binary format (with hexadecimal values) 578 - 579 -AT+RECV: Print last received data in raw format 580 - 581 -AT+VER: Get current image version and Frequency Band 582 - 583 -AT+CFM: Get or Set the confirmation mode (0-1) 584 - 585 -AT+CFS: Get confirmation status of the last AT+SEND (0-1) 586 - 587 -AT+SNR: Get the SNR of the last received packet 588 - 589 -AT+RSSI: Get the RSSI of the last received packet 590 - 591 -AT+TDC: Get or set the application data transmission interval in ms 592 - 593 -AT+PORT: Get or set the application port 594 - 595 -AT+DISAT: Disable AT commands 596 - 597 -AT+PWORD: Set password, max 9 digits 598 - 599 -AT+CHS: Get or Set Frequency (Unit: Hz) for Single Channel Mode 600 - 601 -AT+CHE: Get or Set eight channels mode,Only for US915,AU915,CN470 602 - 603 -AT+PDTA: Print the sector data from start page to stop page 604 - 605 -AT+PLDTA: Print the last few sets of data 606 - 607 -AT+CLRDTA: Clear the storage, record position back to 1st 608 - 609 -AT+SLEEP: Set sleep mode 610 - 611 -AT+EXT: Get or Set external sensor model 612 - 613 -AT+BAT: Get the current battery voltage in mV 614 - 615 -AT+CFG: Print all configurations 616 - 617 -AT+WMOD: Get or Set Work Mode 618 - 619 -AT+ARTEMP: Get or set the internal Temperature sensor alarm range 620 - 621 -AT+CITEMP: Get or set the internal Temperature sensor collection interval in min 622 - 623 -AT+SETCNT: Set the count at present 624 - 625 -AT+RJTDC: Get or set the ReJoin data transmission interval in min 626 - 627 -AT+RPL: Get or set response level 628 - 629 -AT+TIMESTAMP: Get or Set UNIX timestamp in second 630 - 631 -AT+LEAPSEC: Get or Set Leap Second 632 - 633 -AT+SYNCMOD: Get or Set time synchronization method 634 - 635 -AT+SYNCTDC: Get or set time synchronization interval in day 636 - 637 -AT+PID: Get or set the PID 638 - 639 - 640 640 == 6.2 Where to use AT commands and Downlink commands == 641 641 642 642 643 643 **AT commands:** 644 644 645 -[[image:image-20220620153708-1.png||_mstalt="429806" height="603" width="723"]] 516 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220620153708-1.png||_mstalt="429806" height="603" width="723"]] 646 646 647 647 648 648 **Downlink commands:** ... ... @@ -651,13 +651,13 @@ 651 651 652 652 (% style="color:blue" %)**TTN:** 653 653 654 -[[image:image-20220615092124-2.png||_mstalt="429221" height="649" width="688"]] 525 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615092124-2.png||_mstalt="429221" height="649" width="688"]] 655 655 656 656 657 657 658 658 (% style="color:blue" %)**Helium:** 659 659 660 -[[image:image-20220615092551-3.png||_mstalt="430794" height="423" width="835"]] 531 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615092551-3.png||_mstalt="430794" height="423" width="835"]] 661 661 662 662 663 663 ... ... @@ -664,56 +664,49 @@ 664 664 (% style="color:blue" %)**Chirpstack: The downlink window will not be displayed until the network is accessed** 665 665 666 666 667 -[[image:image-20220615094850-6.png||_mstalt="433082"]] 538 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615094850-6.png||_mstalt="433082"]] 668 668 669 669 670 -[[image:image-20220615094904-7.png||_mstalt="433485" height="281" width="911"]] 541 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615094904-7.png||_mstalt="433485" height="281" width="911"]] 671 671 672 672 673 673 674 674 (% style="color:blue" %)**Aws:** 675 675 676 -[[image:image-20220615092939-4.png||_mstalt="434460" height="448" width="894"]] 547 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615092939-4.png||_mstalt="434460" height="448" width="894"]] 677 677 678 678 679 679 == 6.3 How to change the uplink interval? == 680 680 681 - 682 682 Please see this link: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/How%20to%20set%20the%20transmit%20time%20interval/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20set%20the%20transmit%20time%20interval/||_mstmutation="1" style="background-color: rgb(255, 255, 255);"]] 683 683 554 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615154519-3.png||_mstalt="431925" height="672" width="807"]] 684 684 685 685 686 -[[image:image-20220615154519-3.png||_mstalt="431925" height="672" width="807"]] 687 - 688 - 689 689 == 6.4 How to use TTL-USB to connect PC to upgrade firmware? == 690 690 559 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615153355-1.png||_mstalt="430222"]] 691 691 692 -[[image:image-20220615153355-1.png||_mstalt="430222"]] 693 - 694 - 695 695 (% style="color:blue" %)**Step1**(%%): Install TremoProgrammer first. 696 696 697 -[[image:image-20220615170542-5.png||_mstalt="430638"]] 563 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615170542-5.png||_mstalt="430638"]] 698 698 699 - 700 - 701 701 (% _mstmutation="1" style="color:blue" %)**Step2**(%%):wiring method.(% style="display:none" %) 702 702 703 703 First connect the four lines;(% style="display:none" %) 704 704 705 -[[image:image-20220621170938-1.png||_mstalt="431340" height="413" width="419"]],(% style="display:none" %) 569 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220621170938-1.png||_mstalt="431340" height="413" width="419"]],(% style="display:none" %) 706 706 707 707 708 708 Then use DuPont cable to short circuit port3 and port1, and then release them, so that the device enters bootlaod mode. 709 709 710 -[[image:image-20220621170938-2.png||_mstalt="431704"]] 574 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220621170938-2.png||_mstalt="431704"]] 711 711 712 712 713 713 714 714 (% style="color:blue" %)**Step3:**(%%)Select the device port to be connected, baud rate and bin file to be downloaded. 715 715 716 -[[image:image-20220615171334-6.png||_mstalt="431028"]] 580 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615171334-6.png||_mstalt="431028"]] 717 717 718 718 719 719 Click the (% style="color:blue" %)**start**(%%) button to start the firmware upgrade. ... ... @@ -721,7 +721,7 @@ 721 721 722 722 When this interface appears, it indicates that the download has been completed. 723 723 724 -[[image:image-20220620160723-8.png||_mstalt="430703"]] 588 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220620160723-8.png||_mstalt="430703"]] 725 725 726 726 727 727 Finally, unplug the DuPont cable on port4, and then use the DuPont cable to short circuit port3 and port1 to reset the device. ... ... @@ -728,7 +728,7 @@ 728 728 729 729 730 730 731 -[[image:image-20220615154519-3.png||_mstalt="431925" height="672" width="807"]] 595 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220615154519-3.png||_mstalt="431925" height="672" width="807"]] 732 732 733 733 734 734 = 7. Order Info =