Changes for page LHT65N-PIR Temperature/Humidity/PIR Motion Sensor User Manual
Last modified by Xiaoling on 2025/06/10 09:17
From version 10.1
edited by Edwin Chen
on 2023/04/09 08:27
on 2023/04/09 08:27
Change comment:
There is no comment for this version
To version 13.1
edited by Edwin Chen
on 2023/04/09 08:49
on 2023/04/09 08:49
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -228,7 +228,6 @@ 228 228 229 229 === 2.4.3 Built-in Temperature === 230 230 231 - 232 232 [[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220522235639-2.png||_mstalt="431756" height="138" width="722"]] 233 233 234 234 * Temperature: 0x0ABB/100=27.47℃ ... ... @@ -247,21 +247,43 @@ 247 247 248 248 ==== 2.4.5.1 Ext~=0x0A, PIR Sensor ==== 249 249 250 - 251 251 [[image:image-20221224161634-2.png||height="138" width="851"]] 252 252 253 253 254 - * Illumination=0x005E=94 lux252 +==== 2.4.5.2 Ext Value ==== 255 255 256 -The last2bytesofdataaremeaningless254 +There are 4 bytes in Ext Value field. 257 257 258 - [[image:image-20221224161725-3.png]]256 +Bit0 of byte 8th shows if this uplink is generate by PIR activity. 259 259 260 -* When the sensor is not connected or not connected properly, will show "NULL" 258 +(% border="1" cellspacing="4" style="background-color:#ffffcc; color:green; width:490px" %) 259 +|=(% style="width: 147px;" %)((( 260 +**The 8^^th^^ byte** 261 +)))|=(% style="width: 108px;" %)((( 262 +**Bit 1~~7** 263 +)))|=(% style="width: 228px;" %)((( 264 +**Bit 0** 265 +))) 266 +|(% style="width:147px" %)((( 267 +**Value** 268 +)))|(% style="width:108px" %)((( 269 +Reserve 270 +)))|(% style="width:228px" %)((( 271 +((( 272 +0: Normal Uplink 261 261 262 - The last 2 bytes of data are meaningless 274 +1: Uplink by activity detected 275 +))) 276 +))) 263 263 278 +**Note**: Uplink by activity is disable by default. 264 264 280 + 281 +The 9^^th^^ ~~ 11^^st^^ byte: Movement Detect Count. 282 + 283 +0x00 E5 09 : Total detect 58633 activity since end node start. 284 + 285 + 265 265 == 2.5 Show data on Datacake == 266 266 267 267 Datacake IoT platform provides a human-friendly interface to show the sensor data, once we have sensor data in TTN V3, we can use Datacake to connect to TTN V3 and see the data in Datacake. Below are the steps: ... ... @@ -272,7 +272,7 @@ 272 272 273 273 Add Datacake: 274 274 275 -[[image:image-20220523000825-7.png||_mstalt="429884" height="262" width="583"]] 296 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220523000825-7.png||_mstalt="429884" height="262" width="583"]] 276 276 277 277 278 278 ... ... @@ -279,16 +279,16 @@ 279 279 Select default key as Access Key: 280 280 281 281 282 -[[image:image-20220523000825-8.png||_mstalt="430248" height="453" width="406"]] 303 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220523000825-8.png||_mstalt="430248" height="453" width="406"]] 283 283 284 284 285 285 In Datacake console ([[https:~~/~~/datacake.co/>>url:https://datacake.co/]]) , add LHT65 device. 286 286 287 287 288 -[[image:image-20221224161935-5.png||height="523" width="409"]] 309 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20221224161935-5.png||height="523" width="409"]] 289 289 290 290 291 -[[image:image-20221224161957-6.png||height="306" width="852"]] 312 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20221224161957-6.png||height="306" width="852"]] 292 292 293 293 294 294 ... ... @@ -306,18 +306,21 @@ 306 306 * RED LED when external sensor is not connected 307 307 * For each success downlink, the PURPLE LED will blink once 308 308 330 + 309 309 == 2.9 installation == 310 310 333 +~1. Don't install LHT65N-PIR outdoor or place where will get wet 311 311 312 - [[image:image-20220516231650-1.png||_mstalt="428597"height="436"width="428"]]335 +2. Towards the PIR probe to the place where need to monitor activity. 313 313 314 314 338 + 315 315 = 3. Sensors and Accessories = 316 316 317 317 == 3.1 E2 Extension Cable == 318 318 319 319 320 -[[image:image-20220619092222-1.png||_mstalt="429533" height="182" width="188"]][[image:image-20220619092313-2.png||_mstalt="430222" height="182" width="173"]] 344 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220619092222-1.png||_mstalt="429533" height="182" width="188"]][[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220619092313-2.png||_mstalt="430222" height="182" width="173"]] 321 321 322 322 323 323 **1m long breakout cable for LHT65N-E5. Features:** ... ... @@ -329,7 +329,7 @@ 329 329 Update firmware for LHT65N-PIR 330 330 ))) 331 331 332 -[[image:image-20220619092421-3.png||_mstalt="430547" height="371" width="529"]] 356 +[[image:Main.User Manual for LoRaWAN End Nodes.LHT65N-E5 LoRaWAN Temperature_Humidity & Illuminance Sensor User Manual.WebHome@image-20220619092421-3.png||_mstalt="430547" height="371" width="529"]] 333 333 334 334 335 335 = 4. Configure LHT65N-PIR via AT command or LoRaWAN downlink =