Changes for page LHT65N -- Manual do sensor de temperatura e umidade LoRaWAN
Last modified by Xiaoling on 2023/07/18 10:12
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1136,88 +1136,87 @@ 1136 1136 ))) 1137 1137 1138 1138 * ((( 1139 -(% style="color:#4f81bd" %)**Com mandsspecialdesignfor LHT65N**1139 +(% style="color:#4f81bd" %)**CComando de design especial para LHT65N** 1140 1140 ))) 1141 1141 1142 1142 ((( 1143 - These commandsareonlyvalidfor LHT65N,asbelow:1143 +Estes comandos são válidos apenas para LHT65N, como abaixo: 1144 1144 ))) 1145 1145 1146 1146 1147 -== 4.1 Set TransmitInterval Time==1147 +== 4.1 Definir o Intervalo de Transmissão == 1148 1148 1149 1149 1150 - Feature:ChangeLoRaWANEnd NodeTransmitInterval.1150 +Característica: Altere o intervalo de transmissão do nó final LoRaWAN. 1151 1151 1152 +(% style="color:#4f81bd" %)**Comando AT: AT+TDC** 1152 1152 1153 -(% style="color:#4f81bd" %)**AT Command: AT+TDC** 1154 - 1155 1155 (% border="1" cellspacing="5" style="background-color:#f2f2f2; width:501px" %) 1156 -|(% style="background-color:#d9e2f3; color:#0070c0; width:155px" %)** CommandExample**|(% style="background-color:#d9e2f3; color:#0070c0; width:166px" %)**Function**|(% style="background-color:#d9e2f3; color:#0070c0; width:180px" %)**Response**1157 -|(% style="width:155px" %)AT+TDC=?|(% style="width:162px" %) Show currenttransmitInterval|(% style="width:177px" %)30000 OKtheintervalis30000ms = 30s1158 -|(% style="width:155px" %)AT+TDC=60000|(% style="width:162px" %) Set TransmitInterval|(% style="width:177px" %)OKSet transmitinterval to 60000ms = 60 seconds1155 +|(% style="background-color:#d9e2f3; color:#0070c0; width:155px" %)**Exemplo de Comando**|(% style="background-color:#d9e2f3; color:#0070c0; width:166px" %)**Função**|(% style="background-color:#d9e2f3; color:#0070c0; width:180px" %)**Resposta** 1156 +|(% style="width:155px" %)AT+TDC=?|(% style="width:162px" %)Mostrar o Intervalo de Transmissão Actual|(% style="width:177px" %)30000 OK o intervalo é 30000ms = 30s 1157 +|(% style="width:155px" %)AT+TDC=60000|(% style="width:162px" %)Definir o Intervalo de Transmissão|(% style="width:177px" %)OK Definir o intervalo de transmissão para 60000ms = 60 segundos 1159 1159 1160 -(% style="color:#4f81bd" %)** Downlink Command:0x01**1159 +(% style="color:#4f81bd" %)**30000 OK o intervalo é 30000ms = 30s** 1161 1161 1162 -Format: Com mandCode(0x01)followedby3 bytestime value.1161 +Formato: Código de comando (0x01) seguido de valor de tempo de 3 bytes. 1163 1163 1164 - Ifthedownlinkpayload=0100003C, it means settheENDNode'sTransmitIntervalto0x00003C=60(S),whileypecodeis01.1163 +Se a carga útil do downlink=0100003C, isso significa definir o intervalo de transmissão do nó END para 0x00003C=60(S), enquanto o código do tipo é 01. 1165 1165 1166 -* **Ex ample1**: DownlinkPayload:Set TransmitInterval (TDC) = 30 seconds1165 +* **Exemplo 1: Downlink Carga útil: 0100001E** ~/~/ Definir Intervalo de Transmissão (TDC) = 30 segundos 1167 1167 1168 -* **Ex ample2**: DownlinkPayload:Set TransmitInterval (TDC) = 60 seconds1167 +* **Exemplo 2: Downlink Carga útil: 0100003C** ~/~/ Definir Intervalo de Transmissão (TDC) = 60 segundos 1169 1169 1170 1170 1171 -== 4.2 Set ExternalSensorMode ==1170 +== 4.2 Definir o Modo do Sensor Externo == 1172 1172 1173 1173 1174 - Feature:Change ExternalSensorMode.1173 +Característica: Alterar o Modo de Sensor Externo. 1175 1175 1176 -(% style="color:#4f81bd" %)** ATCommand: AT+EXT**1175 +(% style="color:#4f81bd" %)**Comando AT: AT+EXT** 1177 1177 1178 1178 (% border="1" cellspacing="5" style="background-color:#f2f2f2; width:468px" %) 1179 -|(% style="background-color:#d9e2f3; color:#0070c0; width:155px" %)** CommandExample**|(% style="background-color:#d9e2f3; color:#0070c0; width:153px" %)**Function**|(% style="background-color:#d9e2f3; color:#0070c0; width:160px" %)**Response**1180 -|(% style="width:155px" %)AT+EXT=?|(% style="width:151px" %) Get currentexternal sensormode|(% style="width:158px" %)1 OKExternalSensormode =11181 -|(% style="width:155px" %)AT+EXT=1|(% colspan="2" rowspan="1" style="width:309px" %) Set externalsensormode1182 -|(% style="width:155px" %)AT+EXT=9|(% colspan="2" rowspan="1" style="width:309px" %) Setto externalDS18B20withtimestamp1178 +|(% style="background-color:#d9e2f3; color:#0070c0; width:155px" %)**Exemplo de Comando**|(% style="background-color:#d9e2f3; color:#0070c0; width:153px" %)**Função**|(% style="background-color:#d9e2f3; color:#0070c0; width:160px" %)**Resposta** 1179 +|(% style="width:155px" %)AT+EXT=?|(% style="width:151px" %)Obter o modo actual do sensor externo|(% style="width:158px" %)1 OK Modo Sensor externo = 1 1180 +|(% style="width:155px" %)AT+EXT=1|(% colspan="2" rowspan="1" style="width:309px" %)Configurar o modo do sensor externo para 1 1181 +|(% style="width:155px" %)AT+EXT=9|(% colspan="2" rowspan="1" style="width:309px" %)Definir para DS18B20 externo com carimbo de data e hora 1183 1183 1184 -(% style="color:#4f81bd" %)** DownlinkCommand: 0xA2**1183 +(% style="color:#4f81bd" %)**Comando de Ligação Descida: 0xA2** 1185 1185 1186 -Total bytes: 2 ~~ 5 bytes 1185 +Total de bytes: 2 ~~ 5 bytes 1187 1187 1188 -**Ex ample:**1187 +**Exemplo:** 1189 1189 1190 -* 0xA201: Set externalsensortype1189 +* 0xA201: Definir o tipo de sensor externo para E1 1191 1191 1192 -* 0xA209: Sameas AT+EXT=91191 +* 0xA209: O mesmo que AT+EXT=9 1193 1193 1194 -* 0xA20702003c: Sameas AT+SETCNT=601193 +* 0xA20702003c: O mesmo que AT+SETCNT=60 1195 1195 1196 1196 1197 -== 4.3 Enable/DisableuplinkTemperatureprobe ID==1196 +== 4.3 Activar/desactivar a ligação ascendente ID da sonda de temperatura == 1198 1198 1199 1199 1200 1200 ((( 1201 - Feature:IfPIDisnabled, devicewillsendthe temperatureprobeID on:1200 +Característica: Se o PID estiver ativado, o dispositivo enviará o ID da sonda de temperatura em: 1202 1202 ))) 1203 1203 1204 1204 * ((( 1205 - FirstPacket afterOTAAJoin1204 +Primeiro Pacote após a Adesão ao OTAA 1206 1206 ))) 1207 1207 * ((( 1208 - Every24 hours sincethefirstpacket.1207 +A cada 24 horas desde o primeiro pacote. 1209 1209 ))) 1210 1210 1211 1211 ((( 1212 -PID isdefaultsetto disable(0)1211 +PID é definido como padrão para desabilitar (0) 1213 1213 1214 1214 1215 1215 ))) 1216 1216 1217 -(% style="color:#4f81bd" %)** ATCommand:**1216 +(% style="color:#4f81bd" %)**Comando AT:** 1218 1218 1219 1219 (% border="1" cellspacing="5" style="background-color:#f2f2f2; width:381px" %) 1220 -|(% style="background-color:#d9e2f3; color:#0070c0; width:155px" %)** CommandExample**|(% style="background-color:#d9e2f3; color:#0070c0; width:138px" %)**Function**|(% style="background-color:#d9e2f3; color:#0070c0; width:88px" %)**Response**1219 +|(% style="background-color:#d9e2f3; color:#0070c0; width:155px" %)**Exemplo de Comando**|(% style="background-color:#d9e2f3; color:#0070c0; width:138px" %)**Função**|(% style="background-color:#d9e2f3; color:#0070c0; width:88px" %)**Resposta** 1221 1221 |(% style="width:155px" %)AT+PID=1|(% style="width:136px" %)Enable PID uplink|(% style="width:86px" %)OK 1222 1222 1223 1223 (% style="color:#4f81bd" %)**Downlink Command:**