... ... @@ -1,8 +1,10 @@
1 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20--%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/WebHome/image-20230717152014-10.png?width=339&height=575&rev=1.1||alt="image-20230717152014-10.png"]]
1 +(% style="text-align:center" %)
2 +[[image:image-20230717152014-10.png||height="575" width="339"]]
2 2  
3 3  
4 -**Índice:**
5 5  
6 +**Table of Contents:**
7 +
6 6  {{toc/}}
7 7  
8 8  
... ... @@ -15,7 +15,7 @@
15 15  
16 16  
17 17  (((
18 -**O sensor de temperatura e umidade Dragino LHT65N** é um sensor LoRaWAN de longo alcance. Inclui um sensor de temperatura e umidade embutido e tem um conector de sensor externo para conectar a um sensor de temperatura externo.
20 +O sensor de temperatura e umidade Dragino LHT65N é um sensor LoRaWAN de longo alcance. Inclui um sensor de temperatura e umidade embutido e tem um conector de sensor externo para conectar a um sensor de temperatura externo.
19 19  
20 20  
21 21  O LHT65N permite que os usuários enviem dados e alcancem distâncias extremamente longas. Fornece comunicação de espectro de propagação de ultra-longo alcance e alta imunidade à interferência, minimizando o consumo atual. Ele visa aplicações profissionais de rede de sensores sem fio, como sistemas de irrigação, medição inteligente, cidades inteligentes, automação de edifícios e assim por diante.
... ... @@ -1270,274 +1270,405 @@
1270 1270  
1271 1271  (% style="color:#4f81bd" %)**Comando AT: AT+SLEEP**
1272 1272  
1273 -(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:514px" %)
1274 -|(% style="background-color:#d9e2f3; color:#0070c0; width:173px" %)**Exemplo de Comando**|(% style="background-color:#d9e2f3; color:#0070c0; width:152px" %)**Função**|(% style="background-color:#d9e2f3; color:#0070c0; width:184px" %)**Resposta**
1275 -|(% style="width:173px" %)AT+SLEEP|(% style="width:152px" %)Configurar para o modo de suspensão|(% style="width:184px" %)(((
1275 +(% border="1" cellspacing="5" style="background-color:#f2f2f2" %)
1276 +|(% style="background-color:#d9e2f3; color:#0070c0; width:171px" %)**Exemplo de Comando**|(% style="background-color:#d9e2f3; color:#0070c0; width:207px" %)**Função**|(% style="background-color:#d9e2f3; color:#0070c0; width:1110px" %)**Resposta**
1277 +|(% style="width:171px" %)AT+SLEEP|(% style="width:207px" %)Configurar para o modo de suspensão|(% style="width:1110px" %)(((
1276 1276  Limpar todos os dados armazenados do sensor...
1277 1277  
1278 1278  OK
1279 1279  )))
1280 1280  
1281 -(% style="color:#4f81bd" %)**Comando Downlink:**
1283 +(% style="color:#4f81bd" %)**Downlink Command:**
1282 1282  
1283 -* Não há nenhum comando downlink para definir como modo de suspensão.
1285 +* There is no downlink command to set to Sleep mode.
1284 1284  
1285 1285  
1286 -== 4.7 Definir a hora do sistema ==
1288 +== 4.7 Set system time ==
1287 1287  
1288 1288  
1289 -Característica: Definir o tempo do sistema, formato unix. [[Veja aqui os detalhes do formato.>>||anchor="H2.6.2UnixTimeStamp"]]
1291 +Feature: Set system time, unix format. [[See here for format detail.>>||anchor="H2.6.2UnixTimeStamp"]]
1290 1290  
1291 -(% style="color:#4f81bd" %)**Comando AT:**
1293 +(% style="color:#4f81bd" %)**AT Command:**
1292 1292  
1293 1293  (% border="1" cellspacing="5" style="background-color:#f2f2f2; width:506px" %)
1294 -|(% style="background-color:#d9e2f3; color:#0070c0; width:188px" %)**Exemplo de Comando**|(% style="background-color:#d9e2f3; color:#0070c0; width:318px" %)**Função**
1296 +|(% style="background-color:#d9e2f3; color:#0070c0; width:188px" %)**Command Example**|(% style="background-color:#d9e2f3; color:#0070c0; width:318px" %)**Function**
1295 1295  |(% style="width:154px" %)AT+TIMESTAMP=1611104352|(% style="width:285px" %)(((
1296 1296  OK
1297 1297  
1298 -Definir o tempo do sistema para 2021-01-20 00:59:12
1300 +Set System time to 2021-01-20 00:59:12
1299 1299  )))
1300 1300  
1301 -(% style="color:#4f81bd" %)**Comando Downlink:**
1303 +(% style="color:#4f81bd" %)**Downlink Command:**
1302 1302  
1303 -0x306007806000  ~/~/  Definir timestamp para 0x (6007806000), mesmo que AT + TIMESTAMP=1611104352
1305 +0x306007806000  ~/~/  Set timestamp to 0x(6007806000),Same as AT+TIMESTAMP=1611104352
1304 1304  
1305 1305  
1306 -== 4.8 Definir o Modo de Sincronização de Tempo ==
1308 +== 4.8 Set Time Sync Mode ==
1307 1307  
1308 1308  
1309 1309  (((
1310 -Funcionalidade: Ativar / Desativar o tempo do sistema de sincronização via LoRaWAN MAC Command (DeviceTimeReq), o servidor LoRaWAN deve suportar o protocolo v1.0.3 para responder a este comando.
1312 +Feature: Enable/Disable Sync system time via LoRaWAN MAC Command (DeviceTimeReq), LoRaWAN server must support v1.0.3 protocol to reply this command.
1311 1311  )))
1312 1312  
1313 1313  (((
1314 -SYNCMOD é definido como 1 por padrão. Se o usrio quiser definir uma hora diferente do servidor LoRaWAN, o usrio precisa definir isso como 0.
1316 +SYNCMOD is set to 1 by default. If user want to set a different time from LoRaWAN server, user need to set this to 0.
1315 1315  )))
1316 1316  
1317 -(% style="color:#4f81bd" %)**Comando AT:**
1319 +(% style="color:#4f81bd" %)**AT Command:**
1318 1318  
1319 -(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:505px" %)
1320 -|(% style="background-color:#d9e2f3; color:#0070c0; width:177px" %)**Exemplo de Comando**|(% style="background-color:#d9e2f3; color:#0070c0; width:323px" %)**Função**
1321 -|(% style="width:177px" %)AT+SYNCMOD=1|(% style="width:323px" %)Enable Sync system time via LoRaWAN MAC Command (DeviceTimeReq)
1321 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:475px" %)
1322 +|(% style="background-color:#d9e2f3; color:#0070c0; width:156px" %)**Command Example**|(% style="background-color:#d9e2f3; color:#0070c0; width:315px" %)**Function**
1323 +|(% style="width:156px" %)AT+SYNCMOD=1|(% style="width:315px" %)Enable Sync system time via LoRaWAN MAC Command (DeviceTimeReq)
1322 1322  
1323 -(% style="color:#4f81bd" %)**Comando Downlink:**
1325 +(% style="color:#4f81bd" %)**Downlink Command:**
1324 1324  
1325 -0x28 01  ~/~/  Mesmo que AT+SYNCMOD=1
1326 -0x28 00  ~/~/  Igual a AT+SYNCMOD=0
1327 +0x28 01  ~/~/  Same As AT+SYNCMOD=1
1328 +0x28 00  ~/~/  Same As AT+SYNCMOD=0
1327 1327  
1328 1328  
1329 -== 4.9 Definir o Intervalo de Sincronização de Tempo ==
1331 +== 4.9 Set Time Sync Interval ==
1330 1330  
1331 1331  
1332 -Característica: Defina o intervalo de sincronização de tempo do sistema. Valor por omissão SYNCTDC: 10 dias.
1334 +Feature: Define System time sync interval. SYNCTDC default value: 10 days.
1333 1333  
1334 -(% style="color:#4f81bd" %)**Comando AT:**
1336 +(% style="color:#4f81bd" %)**AT Command:**
1335 1335  
1336 -(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:508px" %)
1337 -|(% style="background-color:#d9e2f3; color:#0070c0; width:174px" %)**Exemplo de Comando**|(% style="background-color:#d9e2f3; color:#0070c0; width:330px" %)**Função**
1338 -|(% style="width:174px" %)AT+SYNCTDC=0x0A |(% style="width:330px" %)Set SYNCTDC to 10 (0x0A), so the sync time is 10 days.
1338 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:472px" %)
1339 +|(% style="background-color:#d9e2f3; color:#0070c0; width:158px" %)**Command Example**|(% style="background-color:#d9e2f3; color:#0070c0; width:314px" %)**Function**
1340 +|(% style="width:156px" %)AT+SYNCTDC=0x0A |(% style="width:311px" %)Set SYNCTDC to 10 (0x0A), so the sync time is 10 days.
1339 1339  
1340 -(% style="color:#4f81bd" %)**Comando Downlink:**
1342 +(% style="color:#4f81bd" %)**Downlink Command:**
1341 1341  
1342 -**0x29 0A**  ~/~/ O mesmo que AT+SYNCTDC=0x0A
1344 +**0x29 0A**  ~/~/ Same as AT+SYNCTDC=0x0A
1343 1343  
1344 1344  
1345 -== 4.10 Imprimir a base de dados na página. ==
1347 +== 4.10 Print data entries base on page. ==
1346 1346  
1347 1347  
1348 -Recurso: Imprima os dados do setor da página inicial à página de parada (máximo de 416 páginas).
1350 +Feature: Print the sector data from start page to stop page (max is 416 pages).
1349 1349  
1350 -(% style="color:#4f81bd" %)**Comando AT: AT+PDTA**
1352 +(% style="color:#4f81bd" %)**AT Command: AT+PDTA**
1351 1351  
1352 1352  [[image:image-20230426164330-2.png]]
1353 1353  
1354 -(% style="color:#4f81bd" %)**Comando Downlink:**
1356 +(% style="color:#4f81bd" %)**Downlink Command:**
1355 1355  
1356 -Sem comandos de ligação descendente para a funcionalidade
1358 +No downlink commands for feature
1357 1357  
1358 1358  
1359 -== 4.11 Imprime os últimos dados. ==
1361 +== 4.11 Print last few data entries. ==
1360 1360  
1361 1361  
1362 -Funcionalidade: Imprimir as últimas entradas de dados
1364 +Feature: Print the last few data entries
1363 1363  
1364 -(% style="color:#4f81bd" %)**Comando AT: AT+PLDTA**
1366 +(% style="color:#4f81bd" %)**AT Command: AT+PLDTA**
1365 1365  
1366 1366  [[image:image-20230426164932-3.png]]
1367 1367  
1368 -(% style="color:#4f81bd" %)**Comando Downlink:**
1370 +(% style="color:#4f81bd" %)**Downlink Command:**
1369 1369  
1370 -Sem comandos de ligação descendente para a funcionalidade
1372 +No downlink commands for feature
1371 1371  
1372 1372  
1373 -== 4.12 Limpar o Gravador Flash ==
1375 +== 4.12 Clear Flash Record ==
1374 1374  
1375 1375  
1376 -Recurso: Limpar armazenamento flash para recurso de registro de dados.
1378 +Feature: Clear flash storage for data log feature.
1377 1377  
1378 -(% style="color:#4f81bd" %)**Comando AT: AT+CLRDTA**
1380 +(% style="color:#4f81bd" %)**AT Command: AT+CLRDTA**
1379 1379  
1380 1380  (% border="1" cellspacing="5" style="background-color:#f2f2f2; width:503px" %)
1381 -|(% style="background-color:#d9e2f3; color:#0070c0; width:173px" %)**Exemplo de Comando**|(% style="background-color:#d9e2f3; color:#0070c0; width:130px" %)**Função**|(% style="background-color:#d9e2f3; color:#0070c0; width:198px" %)**Resposta**
1382 -|(% style="width:173px" %)AT+CLRDTA |(% style="width:130px" %)Limpar o registo de data|(% style="width:198px" %)(((
1383 -Limpar todos os dados armazenados do sensor...
1383 +|(% style="background-color:#d9e2f3; color:#0070c0; width:157px" %)**Command Example**|(% style="background-color:#d9e2f3; color:#0070c0; width:137px" %)**Function**|(% style="background-color:#d9e2f3; color:#0070c0; width:209px" %)**Response**
1384 +|(% style="width:155px" %)AT+CLRDTA |(% style="width:134px" %)Clear date record|(% style="width:209px" %)(((
1385 +Clear all stored sensor data…
1384 1384  
1385 1385  OK
1386 1386  )))
1387 1387  
1388 -(% style="color:#4f81bd" %)**Comando Downlink: 0xA3**
1390 +(% style="color:#4f81bd" %)**Downlink Command: 0xA3**
1389 1389  
1390 -* Exemplo: 0xA301  ~/~/ O mesmo que AT+CLRDTA
1392 +* Example: 0xA301  ~/~/  Same as AT+CLRDTA
1391 1391  
1392 1392  
1393 -== 4.13 Enviar automaticamente mensagens sem ACK ==
1395 +== 4.13 Auto Send None-ACK messages ==
1394 1394  
1395 1395  
1396 -Recurso: LHT65N vai esperar ACK para cada uplink, se LHT65N o obter ACK do servidor IoT, ele vai considerar a mensagem o chega ao servidor e armazená-lo.LHT65N continua enviando mensagens em normal periodicamente. Uma vez que o LHT65N recebe ACK de um servidor, ele considerará que a rede está ok e começará a enviar a mensagem de não-chegada.
1398 +Feature: LHT65N will wait for ACK for each uplink, If LHT65N doesn't get ACK from the IoT server, it will consider the message doesn't arrive server and store it. LHT65N keeps sending messages in normal periodically. Once LHT65N gets ACK from a server, it will consider the network is ok and start to send the not-arrive message.
1397 1397  
1398 -(% style="color:#4f81bd" %)**Comando AT: AT+PNACKMD**
1400 +(% style="color:#4f81bd" %)**AT Command: AT+PNACKMD**
1399 1399  
1400 -A configuração de fábrica por omissão é 0
1402 +The default factory setting is 0
1401 1401  
1402 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:445px" %)
1403 -|=(% style="width: 172px; background-color: rgb(217, 226, 243); color: rgb(0, 112, 192);" %)**Exemplo de Comando**|=(% style="width: 180px; background-color: rgb(217, 226, 243); color: rgb(0, 112, 192);" %)**Função**|=(% style="width: 80px; background-color: rgb(217, 226, 243); color: rgb(0, 112, 192);" %)**Resposta**
1404 -|(% style="width:172px" %)AT+PNACKMD=1|(% style="width:180px" %)Poll None-ACK message|(% style="width:80px" %)OK
1404 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:367px" %)
1405 +|=(% style="width: 158px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 120px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 87px;background-color:#D9E2F3;color:#0070C0" %)**Response**
1406 +|(% style="width:158px" %)AT+PNACKMD=1|(% style="width:118px" %)Poll None-ACK message|(% style="width:87px" %)OK
1405 1405  
1406 -(% style="color:#4f81bd" %)**Comando Downlink: 0x34**
1408 +(% style="color:#4f81bd" %)**Downlink Command: 0x34**
1407 1407  
1408 -* Exemplo: 0x3401 ~/~/ O mesmo que AT+PNACKMD=1
1410 +* Example: 0x3401  ~/~/  Same as AT+PNACKMD=1
1409 1409  
1410 1410  
1411 -== 4.14 Comando WMOD modificado para sensor externo TMP117 ou DS18B20 alarme de temperatura (desde firmware 1.3.0) ==
1413 +== 4.14 Modified WMOD command for external sensor TMP117 or DS18B20 temperature alarm(Since firmware 1.3.0) ==
1412 1412  
1413 1413  
1414 -Característica: Definir alarmes internos e externos do sensor de temperatura.
1416 +Feature: Set internal and external temperature sensor alarms.
1415 1415  
1416 1416  (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:500px" %)
1417 -|=(% style="width: 342px; background-color: rgb(217, 226, 243); color: rgb(0, 112, 192);" %)**Exemplo de Comando**|=(% style="width: 181px; background-color: rgb(217, 226, 243); color: rgb(0, 112, 192);" %)**Função**|=(% style="width: 50px;background-color:#D9E2F3;color:#0070C0" %)**Resposta**
1418 -|(% style="width:342px" %)AT+WMOD=parameter1,parameter2,parameter3,parameter4|(% style="width:181px" %)Definir alarmes internos e externos do sensor de temperatura|(% style="width:181px" %)OK
1419 +|=(% style="width: 250px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 200px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 50px;background-color:#D9E2F3;color:#0070C0" %)**Response**
1420 +|(% style="width:268px" %)AT+WMOD=parameter1,parameter2,parameter3,parameter4|(% style="width:255px" %)Set internal and external temperature sensor alarms|(% style="width:181px" %)OK
1419 1419  
1420 1420  (% style="color:#037691" %)**AT+WMOD=parameter1,parameter2,parameter3,parameter4**
1421 1421  
1422 -(% style="color:#037691" %)**Parâmetro 1: Modo de alarme:**
1424 +(% style="color:#037691" %)**Parameter 1**(%%):  Alarm mode:
1423 1423  
1424 -0): Cancelar
1426 +0): Cancel
1425 1425  
1426 -1): Alarme de limiar
1428 +1): Threshold alarm
1427 1427  
1428 -2): Alarme de flutuação
1430 +2): Fluctuation alarm
1429 1429  
1430 1430  
1431 -(% style="color:#037691" %)** Parâmetro 2:**(%%)  Tempo de amostragem. Unidade: segundos, até 255 segundos.
1433 +(% style="color:#037691" %)** Parameter 2**(%%):  Sampling time. Unit: seconds, up to 255 seconds.
1432 1432  
1433 -(% style="color:red" %)**Nota: Quando o tempo de coleta é inferior a 60 segundos e sempre excede o limite de alarme definido, o intervalo de envio não se o tempo de coleta, mas se enviado a cada 60 segundos.**
1435 +(% style="color:red" %)**Note: When the collection time is less than 60 seconds and always exceeds the set alarm threshold, the sending interval will not be the collection time, but will be sent every 60 seconds.**
1434 1434  
1435 1435  
1436 -(% style="color:#037691" %)**Parâmetro 3 e parâmetro 4:**
1438 +(% style="color:#037691" %) **Parameter 3 and parameter 4:**
1437 1437  
1438 -1): Se o modo de alarme é definido como 1: o parâmetro 3 e o parâmetro 4 são válidos, como antes, eles representam baixa temperatura e alta temperatura.
1440 +1):  If Alarm Mode is set to 1: Parameter 3 and parameter 4 are valid, as before, they represent low temperature and high temperature.
1439 1439  
1440 -Tal como AT+WMOD=1,60,45,105, significa alarme de alta e baixa temperatura.
1442 +Such as AT+WMOD=1,60,45,105, it means high and low temperature alarm.
1441 1441  
1442 1442  
1443 -2): Se o Modo de Alarme estiver definido como 2: o parâmetro 3 é válido, que representa a diferença entre a temperatura atualmente coletada e a última temperatura carregada.
1445 +2):  If Alarm Mode is set to 2: Parameter 3 is valid, which represents the difference between the currently collected temperature and the last uploaded temperature.
1444 1444  
1445 -Tal como AT+WMOD=2,10,2, significa que é um alarme de flutuação.
1447 +Such as AT+WMOD=2,10,2,it means that it is a fluctuation alarm.
1446 1446  
1447 -Se a diferença entre a temperatura coletada atual e o último Uplin for de ± 2 graus, o alarme será emitido.
1449 +If the difference between the current collected temperature and the last Uplin is ±2 degrees, the alarm will be issued.
1448 1448  
1449 1449  
1450 -(% style="color:#4f81bd" %)**Comando Downlink: 0xA5**
1452 +(% style="color:#4f81bd" %)**Downlink Command: 0xA5**
1451 1451  
1452 1452  0xA5 00 ~-~- AT+WMOD=0.
1453 1453  
1454 -0xA5 01 0A 11 94 29 04 ~-~- AT+WMOD=1,10,45,105 (AT+WMOD = segundo byte, terceiro byte, quarto e quinto bytes divididos por 100, sexto e sétimo bytes divididos por 100 )
1456 +0xA5 01 0A 11 94 29 04 ~-~- AT+WMOD=1,10,45,105  (AT+WMOD = second byte, third byte, fourth and fifth bytes divided by 100, sixth and seventh bytes divided by 100 )
1455 1455  
1456 -0XA5 01 0A F9 C0 29 04 ~-~-AT+WMOD=1,10,-16,105(Necessidade de converter -16 para -1600 para cálculo-1600(DEC)=FFFFFFFFFFFF9C0(HEX)[UNK][UNK]FFFFFFFF9C0(HEX) +10000(HEX)=F9C0(HEX))
1458 +0XA5 01 0A F9 C0 29 04 ~-~-AT+WMOD=1,10,-16,105(Need to convert -16 to -1600 for calculation,-1600(DEC)=FFFFFFFFFFFFF9C0(HEX)  FFFFFFFFFFFFF9C0(HEX) +10000(HEX)=F9C0(HEX))
1457 1457  
1458 -0xA5 02 0A 02 ~-~- AT+WMOD=2,10,2 (AT+WMOD = segundo byte, terceiro byte, quarto byte)
1460 +0xA5 02 0A 02 ~-~- AT+WMOD=2,10,2  (AT+WMOD = second byte, third byte, fourth byte)
1459 1459  
1460 -0xA5 FF ~-~- Depois que o dispositivo o recebe, carregue a configuração atual do alarme (FPORT=8). Como 01 0A 11 94 29 04 ou 02 0A 02.
1462 +0xA5 FF ~-~- After the device receives it, upload the current alarm configuration (FPORT=8). Such as 01 0A 11 94 29 04 or 02 0A 02.
1461 1461  
1462 1462  
1463 -= 5. Bateria e como substituir =
1465 += 5. Battery & How to replace =
1464 1464  
1465 -== 5.1 Tipo de Bateria ==
1467 +== 5.1 Battery Type ==
1466 1466  
1467 1467  
1468 1468  (((
1469 -LHT65N é equipado com uma bateria Li-MnO2 2400mAH (CR17505). A bateria é uma bateria não recarregável com baixa taxa de descarga direcionada para até 8 ~~ 10 anos de uso. Este tipo de bateria é comumente usado em dispositivos IoT para funcionamento a longo prazo, como medidores de água.
1471 +LHT65N is equipped with a 2400mAH Li-MnO2 (CR17505) battery . The battery is an un-rechargeable battery with low discharge rate targeting for up to 8~~10 years use. This type of battery is commonly used in IoT devices for long-term running, such as water meters.
1470 1470  )))
1471 1471  
1472 1472  (((
1473 -A curva de descarga não é linear, então não pode simplesmente usar porcentagem para mostrar o nível da bateria. Abaixo está o desempenho da bateria.
1475 +The discharge curve is not linear so can't simply use percentage to show the battery level. Below is the battery performance.
1474 1474  
1475 1475  
1476 1476  [[image:image-20220515075034-1.png||_mstalt="428961" height="208" width="644"]]
1477 1477  )))
1478 1478  
1479 -A tensão de trabalho mínima para o LHT65N é ~~ 2.5v. Quando a bateria é inferior a 2.6v, é hora de mudar a bateria.
1481 +The minimum Working Voltage for the LHT65N is ~~ 2.5v. When battery is lower than 2.6v, it is time to change the battery.
1482 +
1480 1480  
1484 +== 5.2 Replace Battery ==
1481 1481  
1482 -== 5.2 Substituir a Bateria ==
1483 1483  
1487 +LHT65N has two screws on the back, Unscrew them, and changing the battery inside is ok. The battery is a general CR17450 battery. Any brand should be ok.
1484 1484  
1485 -LHT65N tem dois parafusos na parte de trás, Desenrocá-los, e mudar a bateria dentro é ok.A bateria é uma bateria CR17450 geral. Qualquer marca deve estar bem.
1486 -
1487 1487  [[image:image-20220515075440-2.png||_mstalt="429546" height="338" width="272"]][[image:image-20220515075625-3.png||_mstalt="431574" height="193" width="257"]]
1488 1488  
1489 1489  
1490 -== 5.3 Análise da Vida da Bateria ==
1492 +== 5.3 Battery Life Analyze ==
1491 1491  
1492 1492  
1493 1493  (((
1494 -Os produtos movidos a bateria Dragino são todos executados no modo de baixa potência. O usuário pode verificar a diretriz a partir deste link para calcular a duração estimada da bateria:
1496 +Dragino battery-powered products are all run in Low Power mode. User can check the guideline from this link to calculate the estimated battery life:
1495 1495  [[https:~~/~~/www.dragino.com/downloads/downloads/LoRa_End_Node/Battery_Analyze/DRAGINO_Battery_Life_Guide.pdf>>https://www.dragino.com/downloads/downloads/LoRa_End_Node/Battery_Analyze/DRAGINO_Battery_Life_Guide.pdf]]
1496 1496  )))
1497 1497  
1498 1498  
1499 1499  (((
1500 -Um relatório de teste detalhado completo para LHT65N em diferentes frequências pode ser encontrado em: [[https:~~/~~/www.dropbox.com/sh/r2i3zlhsyrpavla/AAB1sZw3mdT0K7XjpHCITt13a?dl=0>>https://www.dropbox.com/sh/r2i3zlhsyrpavla/AAB1sZw3mdT0K7XjpHCITt13a?dl=0]]
1502 +A full detail test report for LHT65N on different frequency can be found at : [[https:~~/~~/www.dropbox.com/sh/r2i3zlhsyrpavla/AAB1sZw3mdT0K7XjpHCITt13a?dl=0>>https://www.dropbox.com/sh/r2i3zlhsyrpavla/AAB1sZw3mdT0K7XjpHCITt13a?dl=0]]
1501 1501  )))
1502 1502  
1503 1503  
1504 1504  = 6. FAQ =
1505 1505  
1506 -== 6.1 Como usar o Comando AT? ==
1508 +== 6.1 How to use AT Command? ==
1507 1507  
1508 1508  
1509 -LHT65N suporta AT Command set.User pode usar um adaptador USB para TTL mais o cabo do programa para conectar ao LHT65 para usar o comando AT, como abaixo.
1511 +LHT65N supports AT Command set.User can use a USB to TTL adapter plus the Program Cable to connect to LHT65 for using AT command, as below.
1510 1510  
1511 1511  [[image:image-20220530085651-1.png||_mstalt="429949"]]
1512 1512  
1513 1513  
1514 -**Ligação:**
1516 +**Connection:**
1515 1515  
1516 -* (% style="background-color:yellow" %)**USB para TTL GND <~-~->GND**
1517 -* (% style="background-color:yellow" %)**USB para TTL RXD<~-~->D+**
1518 -* (% style="background-color:yellow" %)**USB para TTL TXD<~-~->A11**
1518 +* (% style="background-color:yellow" %)**USB to TTL GND <~-~->GND**
1519 +* (% style="background-color:yellow" %)**USB to TTL RXD <~-~-> D+**
1520 +* (% style="background-color:yellow" %)**USB to TTL TXD <~-~-> A11**
1519 1519  
1520 1520  (((
1521 -(% _mstmutation="1" style="color:red" %)**(Nota: Este pino corresponde apenas à placa de lead-out vendida pela empresa dragino. Para a placa de lead-out comprada por você, consulte a descrição do pino no Capítulo 6.6)**
1523 +(% _mstmutation="1" style="color:red" %)**(Note: This pin only corresponds to the lead-out board sold by dragino company. For the lead-out board purchased by yourself, please refer to the pin description in Chapter 6.6)**
1524 +
1525 +In PC, User needs to set serial tool(such as [[**putty**>>https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to (% style="color:green" %)**9600**(%%) to access to access serial console for LHT65N. The AT commands are disable by default and need to enter password (default:(% style="color:green" %)**123456**) (%%)to active it. Timeout to input AT Command is 5 min, after 5-minute, user need to input password again. User can use AT+DISAT command to disable AT command before timeout.
1522 1522  )))
1523 1523  
1524 -No PC, o usuário precisa definir a taxa de transmissão da ferramenta serial (tais como [[**putty**>>url:https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) para **9600** para acessar o console serial para LHT65N. Os comandos AT são desabilitados por padrão e precisam digitar senha (padrão:**123456**) para ativá-lo. Tempo limite para inserir o comando AT é de 5 minutos, após 5 minutos, o usuário precisa digitar senha novamente. O usuário pode usar o comando AT + DISAT para desativar o comando AT antes do tempo limite.
1525 1525  
1529 +Input password and ATZ to activate LHT65N,As shown below:
1526 1526  
1527 -Digite a senha e ATZ para ativar LHT65N, como mostrado abaixo:
1528 -
1529 1529  [[image:image-20220530095701-4.png||_mstalt="430014"]]
1530 1530  
1531 1531  
1532 -== 6.2 Onde usar comandos AT e comandos Downlink ==
1534 +AT Command List is as below:
1533 1533  
1536 +AT+<CMD>? :  Help on <CMD>
1534 1534  
1535 -**Comandos AT:**
1538 +AT+<CMD> :  Run <CMD>
1536 1536  
1540 +AT+<CMD>=<value> :  Set the value
1541 +
1542 +AT+<CMD>=? :  Get the value
1543 +
1544 +AT+DEBUG:  Set more info output
1545 +
1546 +ATZ:  Trig a reset of the MCU
1547 +
1548 +AT+FDR:  Reset Parameters to Factory Default, Keys Reserve
1549 +
1550 +AT+DEUI:  Get or Set the Device EUI
1551 +
1552 +AT+DADDR:  Get or Set the Device Address
1553 +
1554 +AT+APPKEY:  Get or Set the Application Key
1555 +
1556 +AT+NWKSKEY:  Get or Set the Network Session Key
1557 +
1558 +AT+APPSKEY:  Get or Set the Application Session Key
1559 +
1560 +AT+APPEUI:  Get or Set the Application EUI
1561 +
1562 +AT+ADR:  Get or Set the Adaptive Data Rate setting. (0: off, 1: on)
1563 +
1564 +AT+TXP:  Get or Set the Transmit Power (0-5, MAX:0, MIN:5, according to LoRaWAN Spec)
1565 +
1566 +AT+DR:  Get or Set the Data Rate. (0-7 corresponding to DR_X)
1567 +
1568 +AT+DCS:  Get or Set the ETSI Duty Cycle setting - 0=disable, 1=enable - Only for testing
1569 +
1570 +AT+PNM:  Get or Set the public network mode. (0: off, 1: on)
1571 +
1572 +AT+RX2FQ:  Get or Set the Rx2 window frequency
1573 +
1574 +AT+RX2DR:  Get or Set the Rx2 window data rate (0-7 corresponding to DR_X)
1575 +
1576 +AT+RX1DL:  Get or Set the delay between the end of the Tx and the Rx Window 1 in ms
1577 +
1578 +AT+RX2DL:  Get or Set the delay between the end of the Tx and the Rx Window 2 in ms
1579 +
1580 +AT+JN1DL:  Get or Set the Join Accept Delay between the end of the Tx and the Join Rx Window 1 in ms
1581 +
1582 +AT+JN2DL:  Get or Set the Join Accept Delay between the end of the Tx and the Join Rx Window 2 in ms
1583 +
1584 +AT+NJM:  Get or Set the Network Join Mode. (0: ABP, 1: OTAA)
1585 +
1586 +AT+NWKID:  Get or Set the Network ID
1587 +
1588 +AT+FCU:  Get or Set the Frame Counter Uplink
1589 +
1590 +AT+FCD:  Get or Set the Frame Counter Downlink
1591 +
1592 +AT+CLASS:  Get or Set the Device Class
1593 +
1594 +AT+JOIN:  Join network
1595 +
1596 +AT+NJS:  Get the join status
1597 +
1598 +AT+SENDB:  Send hexadecimal data along with the application port
1599 +
1600 +AT+SEND:  Send text data along with the application port
1601 +
1602 +AT+RECVB:  Print last received data in binary format (with hexadecimal values)
1603 +
1604 +AT+RECV:  Print last received data in raw format
1605 +
1606 +AT+VER:  Get current image version and Frequency Band
1607 +
1608 +AT+CFM:  Get or Set the confirmation mode (0-1)
1609 +
1610 +AT+CFS:  Get confirmation status of the last AT+SEND (0-1)
1611 +
1612 +AT+SNR:  Get the SNR of the last received packet
1613 +
1614 +AT+RSSI:  Get the RSSI of the last received packet
1615 +
1616 +AT+TDC:  Get or set the application data transmission interval in ms
1617 +
1618 +AT+PORT:  Get or set the application port
1619 +
1620 +AT+DISAT:  Disable AT commands
1621 +
1622 +AT+PWORD: Set password, max 9 digits
1623 +
1624 +AT+CHS:  Get or Set Frequency (Unit: Hz) for Single Channel Mode
1625 +
1626 +AT+CHE:  Get or Set eight channels mode,Only for US915,AU915,CN470
1627 +
1628 +AT+PDTA:  Print the sector data from start page to stop page
1629 +
1630 +AT+PLDTA:  Print the last few sets of data
1631 +
1632 +AT+CLRDTA:  Clear the storage, record position back to 1st
1633 +
1634 +AT+SLEEP:  Set sleep mode
1635 +
1636 +AT+EXT:  Get or Set external sensor model
1637 +
1638 +AT+BAT:  Get the current battery voltage in mV
1639 +
1640 +AT+CFG:  Print all configurations
1641 +
1642 +AT+WMOD:  Get or Set Work Mode
1643 +
1644 +AT+ARTEMP:  Get or set the internal Temperature sensor alarm range
1645 +
1646 +AT+CITEMP:  Get or set the internal Temperature sensor collection interval in min
1647 +
1648 +AT+SETCNT:  Set the count at present
1649 +
1650 +AT+RJTDC:  Get or set the ReJoin data transmission interval in min
1651 +
1652 +AT+RPL:  Get or set response level
1653 +
1654 +AT+TIMESTAMP:  Get or Set UNIX timestamp in second
1655 +
1656 +AT+LEAPSEC:  Get or Set Leap Second
1657 +
1658 +AT+SYNCMOD:  Get or Set time synchronization method
1659 +
1660 +AT+SYNCTDC:  Get or set time synchronization interval in day
1661 +
1662 +AT+PID:  Get or set the PID
1663 +
1664 +
1665 +== 6.2 Where to use AT commands and Downlink commands ==
1666 +
1667 +
1668 +**AT commands: **
1669 +
1537 1537  [[image:image-20220620153708-1.png||_mstalt="429806" height="603" width="723"]]
1538 1538  
1539 1539  
1540 -**Comandos de ligação descendente:**
1673 +**Downlink commands:**
1541 1541  
1542 1542  
1543 1543  (% style="color:blue" %)**TTN:**
... ... @@ -1552,7 +1552,7 @@
1552 1552  
1553 1553  
1554 1554  
1555 -(% style="color:blue" %)**Chirpstack: A janela downlink não será exibida até que a rede seja acessada**
1688 +(% style="color:blue" %)**Chirpstack: The downlink window will not be displayed until the network is accessed**
1556 1556  
1557 1557  
1558 1558  [[image:image-20220615094850-6.png||_mstalt="433082"]]
... ... @@ -1567,13 +1567,13 @@
1567 1567  [[image:image-20220615092939-4.png||_mstalt="434460" height="448" width="894"]]
1568 1568  
1569 1569  
1570 -== 6.3 Como alterar o intervalo de uplink? ==
1703 +== 6.3 How to change the uplink interval? ==
1571 1571  
1572 1572  
1573 -Por favor, veja este link: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/How%20to%20set%20the%20transmit%20time%20interval/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20set%20the%20transmit%20time%20interval/||_mstmutation="1" style="background-color: rgb(255, 255, 255);"]]
1706 +Please see this link: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/How%20to%20set%20the%20transmit%20time%20interval/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20set%20the%20transmit%20time%20interval/||_mstmutation="1" style="background-color: rgb(255, 255, 255);"]]
1574 1574  
1575 1575  
1576 -== 6.4 Como usar TTL-USB para conectar um PC para inserir comandos AT? ==
1709 +== 6.4 How to use TTL-USB to connect a PC to input AT commands? ==
1577 1577  
1578 1578  
1579 1579  [[image:image-20220615153355-1.png||_mstalt="430222"]]
... ... @@ -1582,63 +1582,63 @@
1582 1582  
1583 1583  
1584 1584  (((
1585 -No PC, o usrio precisa definir a taxa de transmissão da ferramenta serial (tais como [[**putty**>>url:https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) para **9600** para acessar o console serial para LHT65N. Os comandos AT são desabilitados por padrão e precisam digitar senha (padrão:**123456**) para ativá-lo. Tempo limite para inserir o comando AT é de 5 minutos, após 5 minutos, o usrio precisa digitar senha novamente. O usuário pode usar o comando AT + DISAT para desativar o comando AT antes do tempo limite.
1718 +In PC, User needs to set serial tool(such as [[**putty**>>https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to (% style="color:green" %)**9600** (%%)to access to access serial console for LHT65N. The AT commands are disable by default and need to enter password (default:(% style="color:green" %)**123456**(% style="color:red" %))(%%) to active it. Timeout to input AT Command is 5 min, after 5-minute, user need to input password again. User can use AT+DISAT command to disable AT command before timeout.
1586 1586  )))
1587 1587  
1588 1588  
1589 -Digite senha e ATZ para ativar LHT65N, como mostrado abaixo:
1722 +Input password and ATZ to activate LHT65N, As shown below:
1590 1590  
1591 1591  [[image:image-20220615154519-3.png||_mstalt="431925" height="672" width="807"]]
1592 1592  
1593 1593  
1594 -== 6.5 Como usar TTL-USB para conectar o PC para atualizar firmware? ==
1727 +== 6.5 How to use TTL-USB to connect PC to upgrade firmware? ==
1595 1595  
1596 1596  
1597 1597  [[image:image-20220615153355-1.png||_mstalt="430222"]]
1598 1598  
1599 1599  
1600 -(% style="color:blue" %)**Passo 1:**(%%) Instale primeiro o seguinte [[TremoProgrammer>>https://www.dropbox.com/sh/g99v0fxcltn9r1y/AAAnJD_qGZ42bB52o4UmH9v9a/LHT65N%20Temperature%20%26%20Humidity%20Sensor/tool?dl=0&subfolder_nav_tracking=1]] .
1733 +(% style="color:blue" %)**Step1**(%%): Install [[TremoProgrammer>>https://www.dropbox.com/sh/g99v0fxcltn9r1y/AAAnJD_qGZ42bB52o4UmH9v9a/LHT65N%20Temperature%20%26%20Humidity%20Sensor/tool?dl=0&subfolder_nav_tracking=1]]  first.
1601 1601  
1602 1602  [[image:image-20220615170542-5.png||_mstalt="430638"]]
1603 1603  
1604 1604  
1605 1605  
1606 -(% _mstmutation="1" style="color:blue" %)**Passo 2:**(%%) método de fiação.(% style="display:none" %)
1739 +(% _mstmutation="1" style="color:blue" %)**Step2**(%%): wiring method.(% style="display:none" %)
1607 1607  
1608 -Primeiro ligar as quatro linhas;(% style="display:none" %)
1741 +First connect the four lines;(% style="display:none" %)
1609 1609  
1610 1610  [[image:image-20220621170938-1.png||_mstalt="431340" height="413" width="419"]],(% style="display:none" %)
1611 1611  
1612 1612  
1613 -Em seguida, use o cabo DuPont para curto-circuito port3 e port1 e, em seguida, solte-os, de modo que o dispositivo entre no modo bootlood.
1746 +Then use DuPont cable to short circuit port3 and port1, and then release them, so that the device enters bootlaod mode.
1614 1614  
1615 1615  [[image:image-20220621170938-2.png||_mstalt="431704"]]
1616 1616  
1617 1617  
1618 1618  
1619 -(% style="color:blue" %)**Passo 3: **(%%)Selecione a porta do dispositivo a ser conectado, taxa de transmissão e arquivo bin a ser baixado.
1752 +(% style="color:blue" %)**Step3: **(%%)Select the device port to be connected, baud rate and bin file to be downloaded.
1620 1620  
1621 1621  [[image:image-20220615171334-6.png||_mstalt="431028"]]
1622 1622  
1623 1623  
1624 -Clique no botão Iniciar para iniciar a atualização do firmware.
1757 +Click the (% style="color:blue" %)**start**(%%) button to start the firmware upgrade.
1625 1625  
1626 1626  
1627 -Quando esta interface aparece, indica que o download foi concldo.
1760 +When this interface appears, it indicates that the download has been completed.
1628 1628  
1629 1629  [[image:image-20220620160723-8.png||_mstalt="430703"]]
1630 1630  
1631 1631  
1632 -Finalmente, desconecte o cabo DuPont no port4 e, em seguida, use o cabo DuPont para a porta de curto-circuito 3 e port1 para redefinir o dispositivo.
1765 +Finally, unplug the DuPont cable on port4, and then use the DuPont cable to short circuit port3 and port1 to reset the device.
1633 1633  
1634 1634  
1635 -== 6.6 Usando USB-TYPE-C para conectar ao computador usando o comando AT ==
1768 +== 6.6 Using USB-TYPE-C to connect to the computer using the AT command ==
1636 1636  
1637 1637  
1638 1638  [[image:image-20220623110706-1.png||_mstalt="427869"]]
1639 1639  
1640 1640  
1641 -**Porto UART de LHT65N:**
1774 +**UART Port of LHT65N:**
1642 1642  
1643 1643  * (% class="mark" %)**PB0: RXD**
1644 1644  * (% class="mark" %)**PB1: TXD**
... ... @@ -1646,110 +1646,109 @@
1646 1646  
1647 1647  [[image:image-20220623112117-4.png||_mstalt="428350" height="459" width="343"]]
1648 1648  
1649 -No PC, o usuário precisa definir a taxa de transmissão da ferramenta serial (tais como [[**putty**>>url:https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) para **9600** para acessar o console serial para LHT65N. Os comandos AT são desabilitados por padrão e precisam digitar senha (padrão:**123456**) para ativá-lo. Tempo limite para inserir o comando AT é de 5 minutos, após 5 minutos, o usuário precisa digitar senha novamente. O usuário pode usar o comando AT + DISAT para desativar o comando AT antes do tempo limite.
1650 1650  
1783 +(((
1784 +In PC, User needs to set serial tool(such as [[**putty**>>https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to (% style="color:green" %)**9600** (%%)to access to access serial console for LHT65N. The AT commands are disable by default and need to enter password (default:(% style="color:green" %)**123456**(% style="color:red" %))(%%) to active it. Timeout to input AT Command is 5 min, after 5-minute, user need to input password again. User can use AT+DISAT command to disable AT command before timeout.
1785 +)))
1651 1651  
1652 -Digite a senha e ATZ para ativar LHT65N, como mostrado abaixo:
1653 1653  
1788 +Input password and ATZ to activate LHT65N,As shown below:
1789 +
1654 1654  [[image:image-20220615154519-3.png||_mstalt="431925" height="672" width="807"]]
1655 1655  
1656 1656  
1657 -== 6.7 Como usar USB-TYPE-C para conectar o PC para atualizar firmware? ==
1793 +== 6.7 How to us USB-TYPE-C to connect PC to upgrade firmware? ==
1658 1658  
1659 1659  
1660 1660  [[image:image-20220623110706-1.png||_mstalt="427869"]]
1661 1661  
1662 1662  
1663 -(% style="color:blue" %)**Passo 1**(%%): Instale primeiro o [[TremoProgrammer>>https://www.dropbox.com/sh/g99v0fxcltn9r1y/AAAnJD_qGZ42bB52o4UmH9v9a/LHT65N%20Temperature%20%26%20Humidity%20Sensor/tool?dl=0&subfolder_nav_tracking=1]].
1799 +(% style="color:blue" %)**Step1**(%%): Instal[[TremoProgrammer>>https://www.dropbox.com/sh/g99v0fxcltn9r1y/AAAnJD_qGZ42bB52o4UmH9v9a/LHT65N%20Temperature%20%26%20Humidity%20Sensor/tool?dl=0&subfolder_nav_tracking=1]]  first.
1664 1664  
1665 1665  [[image:image-20220615170542-5.png||_mstalt="430638"]]
1666 1666  
1667 1667  
1668 1668  
1669 -(% _mstmutation="1" style="color:blue" %)**Passo 2**(%%): método de fiação.(% style="display:none" %)
1805 +(% _mstmutation="1" style="color:blue" %)**Step2**(%%): wiring method.(% style="display:none" %)
1670 1670  
1671 -Primeiro ligar as quatro linhas;
1807 +First connect the four lines;
1672 1672  
1673 1673  [[image:image-20220623113959-5.png||_mstalt="433485" height="528" width="397"]]
1674 1674  
1675 -Conecte A8 e GND com fio Dupont por um tempo e, em seguida, separe-se, entre no modo de redefinição
1811 +Connect A8 and GND with Dupont wire for a while and then separate, enter reset mode
1676 1676  
1677 1677  
1678 1678  
1679 -(% style="color:blue" %)**Passo 3: **(%%)Selecione a porta do dispositivo a ser conectado, taxa de transmissão e arquivo bin a ser baixado.
1815 +(% style="color:blue" %)**Step3: **(%%)Select the device port to be connected, baud rate and bin file to be downloaded.
1680 1680  
1681 1681  [[image:image-20220615171334-6.png||_mstalt="431028"]]
1682 1682  
1683 1683  
1684 -Clique no botão Iniciar para iniciar a atualização do firmware.
1820 +Click the (% style="color:blue" %)**start**(%%) button to start the firmware upgrade.
1685 1685  
1686 1686  
1687 -Quando esta interface aparece, indica que o download foi concldo.
1823 +When this interface appears, it indicates that the download has been completed.
1688 1688  
1689 1689  [[image:image-20220620160723-8.png||_mstalt="430703"]]
1690 1690  
1691 1691  
1692 -Finalmente, desconecte 3.3v, conecte A8 e GND com fio Dupont por um tempo e, em seguida, separe, saia do modo de redefinição
1828 +Finally,Disconnect 3.3v, Connect A8 and GND with Dupont wire for a while and then separate, exit reset mode
1693 1693  
1694 1694  
1695 -== 6.8 Por que não consigo ver as informações do datalog ==
1831 +== 6.8 Why can't I see the datalog information ==
1696 1696  
1697 1697  
1698 -~1. O tempo não está alinhado e o comando de consulta correto não é usado.
1834 +~1. The time is not aligned, and the correct query command is not used.
1699 1699  
1700 -2. Erro decodificador, não analisou os dados do datalog, os dados foram filtrados.
1836 +2. Decoder error, did not parse the datalog data, the data was filtered.
1701 1701  
1702 1702  
1703 -= 7. Informação da Ordem =
1839 += 7. Order Info =
1704 1704  
1705 1705  
1706 -Número da peça: (% style="color:#4f81bd" %)** LHT65N-XX-YY**
1842 +Part Number: (% style="color:#4f81bd" %)** LHT65N-XX-YY**
1707 1707  
1708 -(% style="color:#4f81bd" %)**XX **(%%): A banda de frequência padrão
1844 +(% style="color:#4f81bd" %)**XX **(%%): The default frequency band
1709 1709  
1710 -* (% style="color:#4f81bd" %)** **(% _mstmutation="1" style="color:red" %)**AS923**(%%): Banda LoRaWAN AS923
1711 -* (% style="color:#4f81bd" %)** **(% _mstmutation="1" style="color:red" %)**AU915**(%%): Banda LoRaWAN AU915
1712 -* (% style="color:#4f81bd" %)** **(% _mstmutation="1" style="color:red" %)**EU433**(%%): Banda LoRaWAN EU433
1713 -* (% style="color:#4f81bd" %)** **(% _mstmutation="1" style="color:red" %)**EU868**(%%): Banda LoRaWAN EU868
1714 -* (% style="color:#4f81bd" %)** **(% _mstmutation="1" style="color:red" %)**KR920**(%%): Banda LoRaWAN KR920
1715 -* (% style="color:#4f81bd" %)** **(% _mstmutation="1" style="color:red" %)**US915**(%%): Banda LoRaWAN US915
1716 -* (% style="color:#4f81bd" %)** **(% _mstmutation="1" style="color:red" %)**IN865**(%%): Banda LoRaWAN US915
1717 -* (% style="color:#4f81bd" %)** **(% _mstmutation="1" style="color:red" %)**CN470**(%%): Banda LoRaWAN CN470
1846 +* (% style="color:#4f81bd" %)** **(% _mstmutation="1" style="color:red" %)**AS923**(%%): LoRaWAN AS923 band
1847 +* (% style="color:#4f81bd" %)** **(% _mstmutation="1" style="color:red" %)**AU915**(%%): LoRaWAN AU915 band
1848 +* (% style="color:#4f81bd" %)** **(% _mstmutation="1" style="color:red" %)**EU433**(%%): LoRaWAN EU433 band
1849 +* (% style="color:#4f81bd" %)** **(% _mstmutation="1" style="color:red" %)**EU868**(%%): LoRaWAN EU868 band
1850 +* (% style="color:#4f81bd" %)** **(% _mstmutation="1" style="color:red" %)**KR920**(%%): LoRaWAN KR920 band
1851 +* (% style="color:#4f81bd" %)** **(% _mstmutation="1" style="color:red" %)**US915**(%%): LoRaWAN US915 band
1852 +* (% style="color:#4f81bd" %)** **(% _mstmutation="1" style="color:red" %)**IN865**(%%): LoRaWAN IN865 band
1853 +* (% style="color:#4f81bd" %)** **(% _mstmutation="1" style="color:red" %)**CN470**(%%): LoRaWAN CN470 band
1718 1718  
1719 -(% style="color:#4f81bd" %)**YY**(%%): Acessórios para sensores
1855 +(% style="color:#4f81bd" %)**YY**(%%): Sensor Accessories
1720 1720  
1721 -* (% style="color:red" %)**E3**(%%): Sonda de Temperatura Externa
1857 +* (% style="color:red" %)**E3**(%%): External Temperature Probe
1722 1722  
1723 1723  
1724 -= 8. Informação da Embalagem =
1860 += 8. Packing Info =
1725 1725  
1726 1726  
1727 -**O pacote inclui:**
1863 +**Package Includes**:
1728 1728  
1729 -* LHT65N Sensor de temperatura e umidade x 1
1730 -* Sensor externo opcional
1865 +* LHT65N Temperature & Humidity Sensor x 1
1866 +* Optional external sensor
1731 1731  
1732 -**Dimensão e peso:**
1868 +**Dimension and weight**:
1733 1733  
1734 -* Tamanho do dispositivo: 10 x 10 x 3,5 mm
1735 -* Peso do dispositivo: 120,5g
1870 +* Device Size:  10 x 10 x 3.5 mm
1871 +* Device Weight: 120.5g
1736 1736  
1737 1737  
1738 -= 9. Material de referência =
1874 += 9. Reference material =
1739 1739  
1740 1740  
1741 -* [[Folha de dados, fotografias, descodificador, firmware>>https://www.dropbox.com/sh/una19zsni308dme/AACOKp6J2RF5TMlKWT5zU3RTa?dl=0]]
1877 +* [[Datasheet, photos, decoder, firmware>>https://www.dropbox.com/sh/una19zsni308dme/AACOKp6J2RF5TMlKWT5zU3RTa?dl=0]]
1742 1742  
1743 1743  
1744 -= 10. Aviso FCC =
1880 += 10. FCC Warning =
1745 1745  
1746 1746  
1747 -Este dispositivo está em conformidade com a parte 15 das Regras FCC. A operação es sujeita às seguintes duas condições:
1883 +This device complies with part 15 of the FCC Rules.Operation is subject to the following two conditions:
1748 1748  
1749 -(1) Este dispositivo não pode causar interferência prejudicial;
1885 +(1) This device may not cause harmful interference;
1750 1750  
1751 -(2) este dispositivo deve aceitar qualquer interferência recebida, incluindo interferência que possa causar operação indesejada.
1752 -
1753 -(3) Conforme resolução Anatel 680 - Art. 5º
1754 -
1755 -Os equipamentos de radiação restrita devem conter no produto, em lugar facilmente visível, ou no manual de instruções fornecido pelo fabricante, em local de destaque, informação sobre as implicações de sua operação, nos seguintes termos: Este equipamento não tem direito à proteção contra interferência prejudicial e não pode causar interferência em sistemas devidamente autorizados. Para maiores informações, consulte o site da ANATEL – ( www.anatel.gov.br )
1887 +(2) this device must accept any interference received, including interference that may cause undesired operation.