Changes for page LHT65N -- Manual do sensor de temperatura e umidade LoRaWAN
Last modified by Xiaoling on 2023/07/18 10:12
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1656,56 +1656,56 @@ 1656 1656 [[image:image-20220615154519-3.png||_mstalt="431925" height="672" width="807"]] 1657 1657 1658 1658 1659 -== 6.7 How to useUSB-TYPE-Ctoconnect PCto upgradefirmware? ==1659 +== 6.7 Como usar USB-TYPE-C para conectar o PC para atualizar firmware? == 1660 1660 1661 1661 1662 1662 [[image:image-20220623110706-1.png||_mstalt="427869"]] 1663 1663 1664 1664 1665 -(% style="color:blue" %)** Step1**(%%): Install[[TremoProgrammer>>https://www.dropbox.com/sh/g99v0fxcltn9r1y/AAAnJD_qGZ42bB52o4UmH9v9a/LHT65N%20Temperature%20%26%20Humidity%20Sensor/tool?dl=0&subfolder_nav_tracking=1]]first.1665 +(% style="color:blue" %)**Passo 1**(%%): Instale primeiro o [[TremoProgrammer>>https://www.dropbox.com/sh/g99v0fxcltn9r1y/AAAnJD_qGZ42bB52o4UmH9v9a/LHT65N%20Temperature%20%26%20Humidity%20Sensor/tool?dl=0&subfolder_nav_tracking=1]]. 1666 1666 1667 1667 [[image:image-20220615170542-5.png||_mstalt="430638"]] 1668 1668 1669 1669 1670 1670 1671 -(% _mstmutation="1" style="color:blue" %)** Step2**(%%):wiringmethod.(% style="display:none" %)1671 +(% _mstmutation="1" style="color:blue" %)**Passo 2**(%%): método de fiação.(% style="display:none" %) 1672 1672 1673 - First connectthefour lines;1673 +Primeiro ligar as quatro linhas; 1674 1674 1675 1675 [[image:image-20220623113959-5.png||_mstalt="433485" height="528" width="397"]] 1676 1676 1677 -Con nect A8andGNDwithDupontwire forawhileandthenseparate, enterresetmode1677 +Conecte A8 e GND com fio Dupont por um tempo e, em seguida, separe-se, entre no modo de redefinição 1678 1678 1679 1679 1680 1680 1681 -(% style="color:blue" %)** Step3: **(%%)Select the device port tobe connected,baud rate andbinfileto bedownloaded.1681 +(% style="color:blue" %)**Passo 3: **(%%)Selecione a porta do dispositivo a ser conectado, taxa de transmissão e arquivo bin a ser baixado. 1682 1682 1683 1683 [[image:image-20220615171334-6.png||_mstalt="431028"]] 1684 1684 1685 1685 1686 -Cli ck the(%style="color:blue"%)**start**(%%)buttontostartthefirmwareupgrade.1686 +Clique no botão Iniciar para iniciar a atualização do firmware. 1687 1687 1688 1688 1689 - Whenthis interface appears, it indicatesthat the downloadhasbeencompleted.1689 +Quando esta interface aparece, indica que o download foi concluído. 1690 1690 1691 1691 [[image:image-20220620160723-8.png||_mstalt="430703"]] 1692 1692 1693 1693 1694 -Final ly,Disconnect 3.3v,Connect A8andGNDwithDupontwire forawhileandthenseparate,exitresetmode1694 +Finalmente, desconecte 3.3v, conecte A8 e GND com fio Dupont por um tempo e, em seguida, separe, saia do modo de redefinição 1695 1695 1696 1696 1697 -== 6.8 Whycan'tIseethedataloginformation==1697 +== 6.8 Por que não consigo ver as informações do datalog == 1698 1698 1699 1699 1700 -~1. Thetimeisnot aligned,andthecorrectquerycommandisnot used.1700 +~1. O tempo não está alinhado e o comando de consulta correto não é usado. 1701 1701 1702 -2. Decoder error,didnotparsethedatalogdata,thedatawasfiltered.1702 +2. Erro decodificador, não analisou os dados do datalog, os dados foram filtrados. 1703 1703 1704 1704 1705 -= 7. OrderInfo =1705 += 7. Informação da Ordem = 1706 1706 1707 1707 1708 - PartNumber: (% style="color:#4f81bd" %)** LHT65N-XX-YY**1708 +Número da peça: (% style="color:#4f81bd" %)** LHT65N-XX-YY** 1709 1709 1710 1710 (% style="color:#4f81bd" %)**XX **(%%): The default frequency band 1711 1711