... ... @@ -1021,22 +1021,22 @@
1021 1021  [[image:image-20220619092222-1.png||_mstalt="429533" height="182" width="188"]][[image:image-20220619092313-2.png||_mstalt="430222" height="182" width="173"]]
1022 1022  
1023 1023  
1024 -**1m long breakout cable for LHT65N. Features:**
1024 +**Cabo de ruptura de 1m de comprimento para LHT65N. Caractesticas:**
1025 1025  
1026 1026  * (((
1027 -Use for AT Command, works for both LHT52/LHT65N
1027 +Use para comando AT, funciona para LHT52 / LHT65N
1028 1028  )))
1029 1029  * (((
1030 -Update firmware for LHT65N, works for both LHT52/LHT65N
1030 +Atualização do firmware para LHT65N, funciona para LHT52 / LHT65N
1031 1031  )))
1032 1032  * (((
1033 -Supports ADC mode to monitor external ADC
1033 +Suporta o modo ADC para monitorar ADC externo
1034 1034  )))
1035 1035  * (((
1036 -Supports Interrupt mode
1036 +Suporta o modo Interrupção
1037 1037  )))
1038 1038  * (((
1039 -Exposed All pins from the LHT65N Type-C connector.
1039 +Exposto Todos os pinos do conector tipo C LHT65N.
1040 1040  
1041 1041  
1042 1042  
... ... @@ -1045,59 +1045,59 @@
1045 1045  [[image:image-20220619092421-3.png||_mstalt="430547" height="371" width="529"]]
1046 1046  
1047 1047  
1048 -== 3.2 E3 Temperature Probe ==
1048 +== 3.2 Sonda de temperatura E3 ==
1049 1049  
1050 1050  
1051 1051  [[image:image-20220515080154-4.png||_mstalt="434681" alt="photo-20220515080154-4.png" height="182" width="161"]] [[image:image-20220515080330-5.png||_mstalt="428792" height="201" width="195"]]
1052 1052  
1053 1053  
1054 -Temperature sensor with 2 meters cable long
1054 +Sensor de temperatura com cabo de 2 metros de comprimento
1055 1055  
1056 -* Resolution: 0.0625 °C
1057 -* ±0.5°C accuracy from -10°C to +85°C
1058 -* ±2°C accuracy from -55°C to +125°C
1059 -* Operating Range: -40 ~~ 125 °C
1060 -* Working voltage 2.35v ~~ 5v
1056 +* Resolução: 0,0625 °C
1057 +* ±0,5°C precisão de -10°C a +85°C
1058 +* ±2°C precisão de -55°C a +125°C
1059 +* Faixa de operação: -40 ~~ 125 °C
1060 +* Teno de trabalho 2.35v ~~ 5v
1061 1061  
1062 -== 3.3 E31F Temperature Probe ==
1062 +== 3.3 Sonda de temperatura E31F ==
1063 1063  
1064 1064  
1065 1065  [[image:65N-E31F-1.jpg||height="169" width="170"]] [[image:image-20230717151424-9.png||height="221" width="204"]](% style="display:none" %)
1066 1066  
1067 1067  
1068 -Temperature sensor with 1 meters cable long
1068 +Sensor de temperatura com cabo de 1 metro de comprimento
1069 1069  
1070 1070  
1071 -**Built-in Temperature Sensor:**
1071 +**Sensor de temperatura incorporado:**
1072 1072  
1073 -* Resolution: 0.01 °C
1074 -* Accuracy Tolerance : Typ ±0.3 °C
1075 -* Long Term Drift: < 0.02 °C/yr
1076 -* Operating Range: -40 ~~ 80 °C
1073 +* Resolução: 0,01 °C
1074 +* Tolerância de precisão: Tipo ± 0,3 °C
1075 +* Deriva a longo prazo: < 0,02 °C/ano
1076 +* Faixa de operação: -40 ~~ 80 °C
1077 1077  
1078 -**Built-in Humidity Sensor:**
1078 +**Sensor de humidade incorporado:**
1079 1079  
1080 -* Resolution: 0.04 % RH
1081 -* Accuracy Tolerance : Typ ±3 % RH
1082 -* Long Term Drift: < 0.02 °C/yr
1083 -* Operating Range: 0 ~~ 96 % RH
1080 +* Resolução: 0,04% UR
1081 +* Tolerância da precisão: Tipo ± 3% RH
1082 +* Deriva a longo prazo: < 0,02 °C/ano
1083 +* Faixa de operação: 0 ~~ 96% RH
1084 1084  
1085 -**External Temperature Sensor :**
1085 +**Sensor de temperatura externo:**
1086 1086  
1087 -* Resolution: 0.01 °C
1088 -* Accuracy Tolerance : Typical ±0.3 °C
1089 -* Long Term Drift: < 0.02 °C/yr
1090 -* Operating Range: -40 ~~ 125 °C
1087 +* Resolução: 0,01 °C
1088 +* Tolerância da precisão: pico ± 0,3 °C
1089 +* Deriva a longo prazo: < 0,02 °C/ano
1090 +* Faixa de operação: -40 ~~ 125 °C
1091 1091  
1092 -**External Humidity Sensor :**
1092 +**Sensor de humidade externo:**
1093 1093  
1094 -* Resolution: 0.04 % RH
1095 -* Accuracy Tolerance : Typ ±3 % RH
1096 -* Long Term Drift: < 0.02 °C/yr
1097 -* Operating Range: 0 ~~ 96 % RH
1094 +* Resolução: 0,04% UR
1095 +* Tolerância da precisão: Tipo ± 3% RH
1096 +* Deriva a longo prazo: < 0,02 °C/ano
1097 +* Faixa de operação: 0 ~~ 96% RH
1098 1098  
1099 1099  
1100 -= 4. Configure LHT65N via AT command or LoRaWAN downlink =
1100 += 4. Configurar LHT65N através do comando AT ou LoRaWAN downlink =
1101 1101  
1102 1102  