Changes for page LHT65N -- Manual do sensor de temperatura e umidade LoRaWAN
Last modified by Xiaoling on 2023/07/18 10:12
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1009,8 +1009,10 @@ 1009 1009 == 2.9 Instalação == 1010 1010 1011 1011 1012 +[[image:image-20230717190117-2.png||height="367" width="350"]] 1012 1012 1013 1013 1015 + 1014 1014 = 3. Sensores e acessórios = 1015 1015 1016 1016 == 3.1 Cabo de extensão E2 == ... ... @@ -1019,22 +1019,22 @@ 1019 1019 [[image:image-20220619092222-1.png||_mstalt="429533" height="182" width="188"]][[image:image-20220619092313-2.png||_mstalt="430222" height="182" width="173"]] 1020 1020 1021 1021 1022 -** 1m longbreakoutcablefor LHT65N.Features:**1024 +**Cabo de ruptura de 1m de comprimento para LHT65N. Características:** 1023 1023 1024 1024 * ((( 1025 -Use forAT Command, worksforbothLHT52/LHT65N1027 +Use para comando AT, funciona para LHT52 / LHT65N 1026 1026 ))) 1027 1027 * ((( 1028 - Updatefirmwarefor LHT65N,worksforbothLHT52/LHT65N1030 +Atualização do firmware para LHT65N, funciona para LHT52 / LHT65N 1029 1029 ))) 1030 1030 * ((( 1031 -Sup portsADCmode to monitor external ADC1033 +Suporta o modo ADC para monitorar ADC externo 1032 1032 ))) 1033 1033 * ((( 1034 -Sup portsInterrupt mode1036 +Suporta o modo Interrupção 1035 1035 ))) 1036 1036 * ((( 1037 -Expos edAllpinsfromthe LHT65N Type-Cconnector.1039 +Exposto Todos os pinos do conector tipo C LHT65N. 1038 1038 1039 1039 1040 1040 ... ... @@ -1043,182 +1043,181 @@ 1043 1043 [[image:image-20220619092421-3.png||_mstalt="430547" height="371" width="529"]] 1044 1044 1045 1045 1046 -== 3.2 E3TemperatureProbe==1048 +== 3.2 Sonda de temperatura E3 == 1047 1047 1048 1048 1049 1049 [[image:image-20220515080154-4.png||_mstalt="434681" alt="photo-20220515080154-4.png" height="182" width="161"]] [[image:image-20220515080330-5.png||_mstalt="428792" height="201" width="195"]] 1050 1050 1051 1051 1052 - Temperaturesensorwith2 meterscablelong1054 +Sensor de temperatura com cabo de 2 metros de comprimento 1053 1053 1054 -* Resolu tion: 0.0625 °C1055 -* ±0 .5°Caccuracy from-10°Cto+85°C1056 -* ±2°C accuracy from-55°Cto+125°C1057 -* Operating Range: -40 ~~ 125 °C1058 -* Working voltage2.35v ~~ 5v1056 +* Resolução: 0,0625 °C 1057 +* ±0,5°C precisão de -10°C a +85°C 1058 +* ±2°C precisão de -55°C a +125°C 1059 +* Faixa de operação: -40 ~~ 125 °C 1060 +* Tensão de trabalho 2.35v ~~ 5v 1059 1059 1060 -== 3.3 E31FTemperatureProbe==1062 +== 3.3 Sonda de temperatura E31F == 1061 1061 1062 1062 1063 1063 [[image:65N-E31F-1.jpg||height="169" width="170"]] [[image:image-20230717151424-9.png||height="221" width="204"]](% style="display:none" %) 1064 1064 1065 1065 1066 - Temperaturesensorwith1 meterscablelong1068 +Sensor de temperatura com cabo de 1 metro de comprimento 1067 1067 1068 1068 1069 -** Built-inTemperatureSensor:**1071 +**Sensor de temperatura incorporado:** 1070 1070 1071 -* Resolu tion: 0.01 °C1072 -* AccuracyTolerance : Typ ±0.3 °C1073 -* LongTerm Drift: < 0.02 °C/yr1074 -* Operating Range: -40 ~~ 80 °C1073 +* Resolução: 0,01 °C 1074 +* Tolerância de precisão: Tipo ± 0,3 °C 1075 +* Deriva a longo prazo: < 0,02 °C/ano 1076 +* Faixa de operação: -40 ~~ 80 °C 1075 1075 1076 -** Built-inHumidity Sensor:**1078 +**Sensor de humidade incorporado:** 1077 1077 1078 -* Resolu tion: 0.04H1079 -* AccuracyTolerance: Typ ±3% RH1080 -* LongTerm Drift: < 0.02 °C/yr1081 -* Operating Range: 0 ~~ 961080 +* Resolução: 0,04% UR 1081 +* Tolerância da precisão: Tipo ± 3% RH 1082 +* Deriva a longo prazo: < 0,02 °C/ano 1083 +* Faixa de operação: 0 ~~ 96% RH 1082 1082 1083 -** ExternalTemperatureSensor:**1085 +**Sensor de temperatura externo:** 1084 1084 1085 -* Resolu tion: 0.01 °C1086 -* AccuracyTolerance:Typical±0.3 °C1087 -* LongTerm Drift: < 0.02 °C/yr1088 -* Operating Range: -40 ~~ 125 °C1087 +* Resolução: 0,01 °C 1088 +* Tolerância da precisão: típico ± 0,3 °C 1089 +* Deriva a longo prazo: < 0,02 °C/ano 1090 +* Faixa de operação: -40 ~~ 125 °C 1089 1089 1090 -** ExternalHumiditySensor:**1092 +**Sensor de humidade externo:** 1091 1091 1092 -* Resolu tion: 0.04H1093 -* AccuracyTolerance: Typ ±3% RH1094 -* LongTerm Drift: < 0.02 °C/yr1095 -* Operating Range: 0 ~~ 961094 +* Resolução: 0,04% UR 1095 +* Tolerância da precisão: Tipo ± 3% RH 1096 +* Deriva a longo prazo: < 0,02 °C/ano 1097 +* Faixa de operação: 0 ~~ 96% RH 1096 1096 1097 1097 1098 -= 4. Configur eLHT65NviaATcommand orLoRaWAN downlink =1100 += 4. Configurar LHT65N através do comando AT ou LoRaWAN downlink = 1099 1099 1100 1100 1101 1101 ((( 1102 - Use can configureLHT65N via AT Command orLoRaWAN Downlink.1104 +O uso pode configurar LHT65N via AT Command ou LoRaWAN Downlink. 1103 1103 ))) 1104 1104 1105 1105 * ((( 1106 - ATCommandConnection:See[[FAQ>>||anchor="H6.FAQ"]].1108 +Ligação de Comando AT: Ver [[FAQ>>||anchor="H6.FAQ"]]. 1107 1107 ))) 1108 1108 1109 1109 * ((( 1110 -LoRaWAN Downlink instructionfordifferent platforms:IoTLoRaWANServer>>doc:Main.WebHome]]1112 +Instruções LoRaWAN Downlink para diferentes plataformas: [[Servidor LoRaWAN IoT>>http://wiki.dragino.com/xwiki/bin/view/Main]] 1111 1111 ))) 1112 1112 1113 1113 ((( 1114 - Thereare twokinds ofcommandstoconfigureLHT65N,they are:1116 +Existem dois tipos de comandos para configurar o LHT65N, eles são: 1115 1115 ))) 1116 1116 1117 1117 * ((( 1118 -(% style="color:#4f81bd" %)** GeneralCommands**.1120 +(% style="color:#4f81bd" %)**Comandos Gerais.** 1119 1119 ))) 1120 1120 1121 1121 ((( 1122 - These commandsaretoconfigure:1124 +Estes comandos devem configurar: 1123 1123 ))) 1124 1124 1125 1125 1. ((( 1126 - Generalsystemsettingslike:uplinkinterval.1128 +Configurações gerais do sistema como: intervalo de uplink. 1127 1127 ))) 1128 1128 1. ((( 1129 - LoRaWAN protocol &radio-related commands.1131 +Protocolo LoRaWAN & comandos relacionados com rádio. 1130 1130 ))) 1131 1131 1132 1132 ((( 1133 - TheyarethesameforallDraginoDeviceswhichsupportsDLWS-005 LoRaWAN Stack(Note~*~*).These commandscanbefoundthewiki: [[End Device Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]1135 +Eles são os mesmos para todos os dispositivos Dragino que suportam DLWS-005 LoRaWAN Stack (Nota~*~*). Estes comandos podem ser encontrados na wiki: [[End Device Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] 1134 1134 ))) 1135 1135 1136 1136 * ((( 1137 -(% style="color:#4f81bd" %)**Com mandsspecialdesignfor LHT65N**1139 +(% style="color:#4f81bd" %)**CComando de design especial para LHT65N** 1138 1138 ))) 1139 1139 1140 1140 ((( 1141 - These commandsareonlyvalidfor LHT65N,asbelow:1143 +Estes comandos são válidos apenas para LHT65N, como abaixo: 1142 1142 ))) 1143 1143 1144 1144 1145 -== 4.1 Set TransmitInterval Time==1147 +== 4.1 Definir o Intervalo de Transmissão == 1146 1146 1147 1147 1148 - Feature:ChangeLoRaWANEnd NodeTransmitInterval.1150 +Característica: Altere o intervalo de transmissão do nó final LoRaWAN. 1149 1149 1152 +(% style="color:#4f81bd" %)**Comando AT: AT+TDC** 1150 1150 1151 -(% style="color:#4f81bd" %)**AT Command: AT+TDC** 1152 - 1153 1153 (% border="1" cellspacing="5" style="background-color:#f2f2f2; width:501px" %) 1154 -|(% style="background-color:#d9e2f3; color:#0070c0; width:155px" %)** CommandExample**|(% style="background-color:#d9e2f3; color:#0070c0; width:166px" %)**Function**|(% style="background-color:#d9e2f3; color:#0070c0; width:180px" %)**Response**1155 -|(% style="width:155px" %)AT+TDC=?|(% style="width:162px" %) Show currenttransmitInterval|(% style="width:177px" %)30000 OKtheintervalis30000ms = 30s1156 -|(% style="width:155px" %)AT+TDC=60000|(% style="width:162px" %) Set TransmitInterval|(% style="width:177px" %)OKSet transmitinterval to 60000ms = 60 seconds1155 +|(% style="background-color:#d9e2f3; color:#0070c0; width:155px" %)**Exemplo de Comando**|(% style="background-color:#d9e2f3; color:#0070c0; width:166px" %)**Função**|(% style="background-color:#d9e2f3; color:#0070c0; width:180px" %)**Resposta** 1156 +|(% style="width:155px" %)AT+TDC=?|(% style="width:162px" %)Mostrar o Intervalo de Transmissão Actual|(% style="width:177px" %)30000 OK o intervalo é 30000ms = 30s 1157 +|(% style="width:155px" %)AT+TDC=60000|(% style="width:162px" %)Definir o Intervalo de Transmissão|(% style="width:177px" %)OK Definir o intervalo de transmissão para 60000ms = 60 segundos 1157 1157 1158 -(% style="color:#4f81bd" %)** Downlink Command:0x01**1159 +(% style="color:#4f81bd" %)**30000 OK o intervalo é 30000ms = 30s** 1159 1159 1160 -Format: Com mandCode(0x01)followedby3 bytestime value.1161 +Formato: Código de comando (0x01) seguido de valor de tempo de 3 bytes. 1161 1161 1162 - Ifthedownlinkpayload=0100003C, it means settheENDNode'sTransmitIntervalto0x00003C=60(S),whileypecodeis01.1163 +Se a carga útil do downlink=0100003C, isso significa definir o intervalo de transmissão do nó END para 0x00003C=60(S), enquanto o código do tipo é 01. 1163 1163 1164 -* **Ex ample1**: DownlinkPayload:Set TransmitInterval (TDC) = 30 seconds1165 +* **Exemplo 1: Downlink Carga útil: 0100001E** ~/~/ Definir Intervalo de Transmissão (TDC) = 30 segundos 1165 1165 1166 -* **Ex ample2**: DownlinkPayload:Set TransmitInterval (TDC) = 60 seconds1167 +* **Exemplo 2: Downlink Carga útil: 0100003C** ~/~/ Definir Intervalo de Transmissão (TDC) = 60 segundos 1167 1167 1168 1168 1169 -== 4.2 Set ExternalSensorMode ==1170 +== 4.2 Definir o Modo do Sensor Externo == 1170 1170 1171 1171 1172 - Feature:Change ExternalSensorMode.1173 +Característica: Alterar o Modo de Sensor Externo. 1173 1173 1174 -(% style="color:#4f81bd" %)** ATCommand: AT+EXT**1175 +(% style="color:#4f81bd" %)**Comando AT: AT+EXT** 1175 1175 1176 -(% border="1" cellspacing="5" style="background-color:#f2f2f2; width: 468px" %)1177 -|(% style="background-color:#d9e2f3; color:#0070c0; width:1 55px" %)**CommandExample**|(% style="background-color:#d9e2f3; color:#0070c0; width:153px" %)**Function**|(% style="background-color:#d9e2f3; color:#0070c0; width:160px" %)**Response**1178 -|(% style="width:1 55px" %)AT+EXT=?|(% style="width:151px" %)Get currentexternal sensormode|(% style="width:158px" %)1 OKExternalSensormode =11179 -|(% style="width:1 55px" %)AT+EXT=1|(% colspan="2" rowspan="1" style="width:309px" %)Set externalsensormode1180 -|(% style="width:1 55px" %)AT+EXT=9|(% colspan="2" rowspan="1" style="width:309px" %)Setto externalDS18B20withtimestamp1177 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:509px" %) 1178 +|(% style="background-color:#d9e2f3; color:#0070c0; width:172px" %)**Exemplo de Comando**|(% style="background-color:#d9e2f3; color:#0070c0; width:173px" %)**Função**|(% style="background-color:#d9e2f3; color:#0070c0; width:159px" %)**Resposta** 1179 +|(% style="width:172px" %)AT+EXT=?|(% style="width:173px" %)Obter o modo actual do sensor externo|(% style="width:159px" %)1 OK Modo Sensor externo = 1 1180 +|(% style="width:172px" %)AT+EXT=1|(% colspan="2" rowspan="1" style="width:333px" %)Configurar o modo do sensor externo para 1 1181 +|(% style="width:172px" %)AT+EXT=9|(% colspan="2" rowspan="1" style="width:333px" %)Definir para DS18B20 externo com carimbo de data e hora 1181 1181 1182 -(% style="color:#4f81bd" %)** DownlinkCommand: 0xA2**1183 +(% style="color:#4f81bd" %)**Comando de Ligação Descida: 0xA2** 1183 1183 1184 -Total bytes: 2 ~~ 5 bytes 1185 +Total de bytes: 2 ~~ 5 bytes 1185 1185 1186 -**Ex ample:**1187 +**Exemplo:** 1187 1187 1188 -* 0xA201: Set externalsensortype1189 +* 0xA201: Definir o tipo de sensor externo para E1 1189 1189 1190 -* 0xA209: Sameas AT+EXT=91191 +* 0xA209: O mesmo que AT+EXT=9 1191 1191 1192 -* 0xA20702003c: Sameas AT+SETCNT=601193 +* 0xA20702003c: O mesmo que AT+SETCNT=60 1193 1193 1194 1194 1195 -== 4.3 Enable/DisableuplinkTemperatureprobe ID==1196 +== 4.3 Activar/desactivar a ligação ascendente ID da sonda de temperatura == 1196 1196 1197 1197 1198 1198 ((( 1199 - Feature:IfPIDisnabled, devicewillsendthe temperatureprobeID on:1200 +Característica: Se o PID estiver ativado, o dispositivo enviará o ID da sonda de temperatura em: 1200 1200 ))) 1201 1201 1202 1202 * ((( 1203 - FirstPacket afterOTAAJoin1204 +Primeiro Pacote após a Adesão ao OTAA 1204 1204 ))) 1205 1205 * ((( 1206 - Every24 hours sincethefirstpacket.1207 +A cada 24 horas desde o primeiro pacote. 1207 1207 ))) 1208 1208 1209 1209 ((( 1210 -PID isdefaultsetto disable(0)1211 +PID é definido como padrão para desabilitar (0) 1211 1211 1212 1212 1213 1213 ))) 1214 1214 1215 -(% style="color:#4f81bd" %)** ATCommand:**1216 +(% style="color:#4f81bd" %)**Comando AT:** 1216 1216 1217 -(% border="1" cellspacing="5" style="background-color:#f2f2f2; width: 381px" %)1218 -|(% style="background-color:#d9e2f3; color:#0070c0; width:1 55px" %)**CommandExample**|(% style="background-color:#d9e2f3; color:#0070c0; width:138px" %)**Function**|(% style="background-color:#d9e2f3; color:#0070c0; width:88px" %)**Response**1219 -|(% style="width:1 55px" %)AT+PID=1|(% style="width:136px" %)Enable PIDuplink|(% style="width:86px" %)OK1218 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:504px" %) 1219 +|(% style="background-color:#d9e2f3; color:#0070c0; width:172px" %)**Exemplo de Comando**|(% style="background-color:#d9e2f3; color:#0070c0; width:237px" %)**Função**|(% style="background-color:#d9e2f3; color:#0070c0; width:81px" %)**Resposta** 1220 +|(% style="width:172px" %)AT+PID=1|(% style="width:237px" %)Activar a ligação ascendente PID|(% style="width:81px" %)OK 1220 1220 1221 -(% style="color:#4f81bd" %)**Downlink Command:**1222 +(% style="color:#4f81bd" %)**Comando Downlink:** 1222 1222 1223 1223 * **0xA800** **~-~->** AT+PID=0 1224 1224 * **0xA801** **~-~->** AT+PID=1