Changes for page LHT65N -- Manual do sensor de temperatura e umidade LoRaWAN
Last modified by Xiaoling on 2023/07/18 10:12
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -854,9 +854,9 @@ 854 854 855 855 (% style="color:#4f81bd" %)**Comando Downlink: AAXXXXXXXXXXXXXXXXXXXXX** 856 856 857 -Total bytes: 8 bytes 857 +Total de bytes: 8 bytes 858 858 859 -**Ex ample:**AA0100010001003C859 +**Exemplo: AA010001000003C** 860 860 861 861 WMOD=01 862 862 ... ... @@ -867,13 +867,13 @@ 867 867 TEMPhigh=003C 868 868 869 869 870 -**DS18B20 andTMP117Threshold Alarm**870 +**Alarme de limiar DS18B20 e TMP117** 871 871 872 -** ~AT+WMOD=1,60,-10,20**872 +**AT+WMOD=1,60,-10,20** 873 873 874 -(% style="color:#4f81bd" %)**Downlink Command:**874 +(% style="color:#4f81bd" %)**Comando Downlink:** 875 875 876 -**Ex ample:**A5013CFC180014876 +**Exemplo: A5013CFC180014** 877 877 878 878 MOD=01 879 879 ... ... @@ -884,33 +884,33 @@ 884 884 TEMPhigh=0014 885 885 886 886 887 -** FluctuationalarmforDS18B20andTMP117(Acquisition time: minimum1s)**887 +**Alarme de flutuação para DS18B20 e TMP117 (tempo de aquisição: mínimo 1s)** 888 888 889 889 **AT+WMOD=2,60,5** 890 890 891 -(% style="color:#4f81bd" %)**Downlink Command:**891 +(% style="color:#4f81bd" %)**Comando Downlink:** 892 892 893 -**Ex ample:**A5023C05893 +**Exemplo: A5023C05** 894 894 895 895 MOD=02 896 896 897 897 CITEMP=3C(S) 898 898 899 -temperatur e fluctuation=05899 +flutuação da temperatura=05 900 900 901 901 902 -** Sampling multipletimesanduplink together**902 +**Amostragem múltiplas vezes e uplink juntos** 903 903 904 904 **AT+WMOD=3,1,60,20,-16,32,1** 905 905 906 -Expl ain:906 +Explique: 907 907 908 -* (% style="color:#037691" %)** parameter1: **(%%)Set Working Mode to **Mode 3**909 -* (% style="color:#037691" %)** parameter2:**(%%) Set the temperature sampling mode to** 1**(1:DS18B20;2:TMP117;3:** **Internal GXHT30).910 -* (% style="color:#037691" %)** parameter3: **(%%)Sampling Interval is **60**s.911 -* (% style="color:#037691" %)** parameter4: **(%%)When there is **20** sampling dats, Device will send these data via one uplink. (max value is 60, means max 60 sampling in one uplink)912 -* (% style="color:#037691" %)** parameter5 ¶meter6: **(%%)Temperature alarm range is **-16** to **32**°C,913 -* (% style="color:#037691" %)** parameter7:**(%%) 1 to enable temperature alarm, **0** to disable the temperature alarm. If alarm is enabled, a data will be sent immediately if temperate exceeds the Alarm range.908 +* (% style="color:#037691" %)**Parâmetro 1: **(%%)Set Working Mode to **Mode 3** 909 +* (% style="color:#037691" %)**Parâmetro 2:**(%%) Set the temperature sampling mode to** 1**(1:DS18B20;2:TMP117;3:** **Internal GXHT30). 910 +* (% style="color:#037691" %)**Parâmetro 3: **(%%)Sampling Interval is **60**s. 911 +* (% style="color:#037691" %)**Parâmetro 4: **(%%)When there is **20** sampling dats, Device will send these data via one uplink. (max value is 60, means max 60 sampling in one uplink) 912 +* (% style="color:#037691" %)**Parâmetro 5: & Parâmetro 6: **(%%)Temperature alarm range is **-16** to **32**°C, 913 +* (% style="color:#037691" %)**Parâmetro 7:**(%%) 1 to enable temperature alarm, **0** to disable the temperature alarm. If alarm is enabled, a data will be sent immediately if temperate exceeds the Alarm range. 914 914 915 915 (% style="color:#4f81bd" %)**Downlink Command:** 916 916