Changes for page LHT65N -- Manual do sensor de temperatura e umidade LoRaWAN
Last modified by Xiaoling on 2023/07/18 10:12
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -634,7 +634,7 @@ 634 634 |(% style="width:96px" %)**Status&Ext**|(% style="width:124px" %)None-ACK Flag|(% style="width:146px" %)Poll Message FLAG|(% style="width:109px" %)Sync time OK|(% style="width:143px" %)Unix Time Request|(% style="width:106px" %)Ext: 0b(1001) 635 635 636 636 * (% style="color:blue" %)**Poll Message Flag**:(%%) 1: This message is a poll message reply, 0: means this is a normal uplink. 637 -* (% style="color:blue" %)**Sync time OK**: (%%) 1: Set time ok ,0: N/A. After time SYNC request is sent, LHT65N will set this bit to 0 until got the time stamp from the application server.637 +* (% style="color:blue" %)**Sync time OK**: (%%) 1: Set time ok,0: N/A. After time SYNC request is sent, LHT65N will set this bit to 0 until got the time stamp from the application server. 638 638 * (% style="color:blue" %)**Unix Time Request**:(%%) 1: Request server downlink Unix time, 0 : N/A. In this mode, LHT65N will set this bit to 1 every 10 days to request a time SYNC. (AT+SYNCMOD to set this) 639 639 640 640 == 2.5 Show data on Datacake == ... ... @@ -776,7 +776,7 @@ 776 776 777 777 Is to check 2020/12/1 07:40:00 to 2020/12/1 08:40:00's data 778 778 779 -Uplink Internal =5s ,means LHT65N will send one packet every 5s. range 5~~255s.779 +Uplink Internal =5s,means LHT65N will send one packet every 5s. range 5~~255s. 780 780 781 781 782 782 === 2.6.5 Datalog Uplink payload === ... ... @@ -867,7 +867,7 @@ 867 867 === 2.7.1 ALARM MODE ( Since v1.3.1 firmware) === 868 868 869 869 870 -**Internal GXHT30 temperature alarm (Acquisition time: fixed at one minute)**870 +**Internal GXHT30 temperature alarm(Acquisition time: fixed at one minute)** 871 871 872 872 ((( 873 873 (% class="box infomessage" %) ... ... @@ -878,7 +878,7 @@ 878 878 879 879 **AT+ARTEMP**: Gets or sets the alarm range of the internal temperature sensor 880 880 881 -(% _mstmutation="1" %)**AT+ARTEMP= ?**(%%): Gets the alarm range of the internal temperature sensor(% style="display:none" %)881 +(% _mstmutation="1" %)**AT+ARTEMP=? **(%%): Gets the alarm range of the internal temperature sensor(% style="display:none" %) 882 882 883 883 **AT+ARTEMP=45,105**: Set the internal temperature sensor alarm range from 45 to 105. 884 884 ... ... @@ -888,7 +888,7 @@ 888 888 889 889 (% style="color:#4f81bd" %)**Downlink Command:** 890 890 891 -AT+WMOD=1: A501 , 891 +AT+WMOD=1: A501 , AT+WMOD=0 : A600 892 892 893 893 AT+CITEMP=1 : A60001 894 894 ... ... @@ -931,7 +931,7 @@ 931 931 TEMPhigh=0014 932 932 933 933 934 -**Fluctuation alarm for DS18B20 and TMP117 (Acquisition time: minimum 1s)**934 +**Fluctuation alarm for DS18B20 and TMP117(Acquisition time: minimum 1s)** 935 935 936 936 **AT+WMOD=2,60,5** 937 937