Changes for page LHT65N -- Manual do sensor de temperatura e umidade LoRaWAN
Last modified by Xiaoling on 2023/07/18 10:12
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -776,7 +776,7 @@ 776 776 777 777 Is to check 2020/12/1 07:40:00 to 2020/12/1 08:40:00's data 778 778 779 -Uplink Internal =5s ,means LHT65N will send one packet every 5s. range 5~~255s.779 +Uplink Internal =5s, means LHT65N will send one packet every 5s. range 5~~255s. 780 780 781 781 782 782 === 2.6.5 Datalog Uplink payload === ... ... @@ -867,7 +867,7 @@ 867 867 === 2.7.1 ALARM MODE ( Since v1.3.1 firmware) === 868 868 869 869 870 -**Internal GXHT30 temperature alarm (Acquisition time: fixed at one minute)**870 +**Internal GXHT30 temperature alarm(Acquisition time: fixed at one minute)** 871 871 872 872 ((( 873 873 (% class="box infomessage" %) ... ... @@ -878,7 +878,7 @@ 878 878 879 879 **AT+ARTEMP**: Gets or sets the alarm range of the internal temperature sensor 880 880 881 -(% _mstmutation="1" %)**AT+ARTEMP= ?**(%%): Gets the alarm range of the internal temperature sensor(% style="display:none" %)881 +(% _mstmutation="1" %)**AT+ARTEMP=? **(%%): Gets the alarm range of the internal temperature sensor(% style="display:none" %) 882 882 883 883 **AT+ARTEMP=45,105**: Set the internal temperature sensor alarm range from 45 to 105. 884 884 ... ... @@ -888,7 +888,7 @@ 888 888 889 889 (% style="color:#4f81bd" %)**Downlink Command:** 890 890 891 -AT+WMOD=1: A501 , 891 +AT+WMOD=1: A501 , AT+WMOD=0 : A600 892 892 893 893 AT+CITEMP=1 : A60001 894 894 ... ... @@ -931,7 +931,7 @@ 931 931 TEMPhigh=0014 932 932 933 933 934 -**Fluctuation alarm for DS18B20 and TMP117 (Acquisition time: minimum 1s)**934 +**Fluctuation alarm for DS18B20 and TMP117(Acquisition time: minimum 1s)** 935 935 936 936 **AT+WMOD=2,60,5** 937 937 ... ... @@ -1016,7 +1016,7 @@ 1016 1016 ))) 1017 1017 1018 1018 ((( 1019 -(% _mstmutation="1" %)**AT+ARTEMP= ?**(%%): Gets the alarm range of the internal temperature sensor(% style="display:none" %)1019 +(% _mstmutation="1" %)**AT+ARTEMP=? **(%%): Gets the alarm range of the internal temperature sensor(% style="display:none" %) 1020 1020 ))) 1021 1021 1022 1022 ((( ... ... @@ -1070,7 +1070,7 @@ 1070 1070 **1m long breakout cable for LHT65N. Features:** 1071 1071 1072 1072 * ((( 1073 -Use for AT Command ,works for both LHT52/LHT65N1073 +Use for AT Command, works for both LHT52/LHT65N 1074 1074 ))) 1075 1075 * ((( 1076 1076 Update firmware for LHT65N, works for both LHT52/LHT65N